Ihse Draco 485-BC, Draco 485-BS, Draco 485-BX, Draco 485-BCC, Draco 485-BSS User Manual

...
Page 1
IHSE GmbH
Maybachstrasse 11 88094 Oberteuringen Germany
info@ihse.de www.ihse.de
Tel. +49 7546-9248-0 Fax +49 7546-9248-48
User Manual
Edition: 2014-04-15
Draco
(Cross) Repeater
Model:
485 Series
Page 2
Draco (Cross) Repeater
2 2014-04-15
Copyright
© 2014. All rights reserved. This information may not be reproduced in any manner without the prior written consent of the manufacturer.
Information in this document is subject to change without notice.
Trademarks
All trademark and trade names mentioned in this document are acknowledged to be the property of their respective owners.
Disclaimer
While every precaution has been taken during preparation of this manual, the manufacturer assumes no liability for errors or omissions. The manufacturer assumes no liability for damages resulting from the use of the information contained herein.
The manufacturer reserves the right to change specifications, functions, or circuitry of the product without notice.
The manufacturer cannot accept liability for damage due to misuse of the product or due to any other circumstances outside the manufacturer’s control (whether environmental or installation related). The manufacturer shall not be liable for any loss, damage, or injury arising directly, indirectly, incidentally, or consequently from the use of this product.
Page 3
Contents
2014-04-15 3
Contents
1 About This Manual ....................................................................... 5
1.1 Scope.................................................................................. 5
1.2 Validity ................................................................................ 5
1.3 Cautions and Notes ............................................................ 5
2 Safety Instructions....................................................................... 6
3 Description ................................................................................... 7
3.1 Application .......................................................................... 7
3.2 System Overview ................................................................ 8
3.3 Product Range .................................................................... 9
3.3.1 Chassis ................................................................. 9
3.3.2 (Cross) Repeater Modules .................................. 10
3.4 Accessories Upgrade Kits ................................................. 10
3.5 Accessories....................................................................... 11
3.6 Device Views .................................................................... 11
3.6.1 2-fold Vario Chassis 474-BODY2/2R .................. 11
3.6.2 2-fold Vario Chassis 474-BODY2N ..................... 12
3.6.3 4-fold Vario Chassis 474-BODY4/4R .................. 13
3.6.4 6-fold Vario Chassis 474-BODY6R ..................... 14
3.6.5 6-fold Vario Chassis 474-BODY6BP................... 15
3.6.6 6-fold Vario Chassis 474-BODY6BPF................. 16
3.6.7 21-fold Vario Chassis 474-BODY21R ................. 17
3.6.8 Model 485-BC ..................................................... 18
3.6.9 Model 485-BS ..................................................... 18
3.6.10 Model 485-BX ..................................................... 18
3.6.11 Model 485-BCC .................................................. 19
3.6.12 Model 485-BSS................................................... 19
3.6.13 Model 485-BXX................................................... 20
3.7 Status LEDs ...................................................................... 21
3.7.1 Status (Cross) Repeater Module......................... 21
Page 4
Draco (Cross) Repeater
4 2014-04-15
4 Installation .................................................................................. 22
4.1 Package Contents............................................................. 22
4.2 System anschließen.......................................................... 22
4.2.1 (Cross) Repeater Setup ...................................... 22
4.3 Example Applications........................................................ 23
5 Configuration.............................................................................. 25
6 Operation .................................................................................... 25
7 Specifications............................................................................. 26
7.1 Interfaces .......................................................................... 26
7.1.1 RJ45 (Interconnect) ............................................ 26
7.1.2 Fiber SFP Type LC (Interconnect) ...................... 26
7.2 Interconnect Cable............................................................ 27
7.2.1 Cat X ................................................................... 27
7.2.2 Fiber.................................................................... 28
7.3 Connector Pinouts ............................................................ 29
7.4 Power Supply.................................................................... 30
7.5 Environmental Conditions ................................................. 30
7.6 Size................................................................................... 31
7.7 Shipping Weight................................................................ 32
8 Troubleshooting......................................................................... 33
8.1 General Failures ............................................................... 33
9 Technical Support ...................................................................... 34
9.1 Support Checklist.............................................................. 34
9.2 Shipping Checklist ............................................................ 34
10 Certificates.................................................................................. 35
10.1 CE Declaration Of Conformity........................................... 35
10.2 North American Regulatory Compliance........................... 36
10.3 Product Safety .................................................................. 36
10.4 WEEE ............................................................................... 37
10.5 RoHS/RoHS 2................................................................... 37
11 Glossary...................................................................................... 38
Pos: 1 /806-IHSE/Zu diesem Handbuch/ATB_Zu di esem Handbuch @ 5\mod_1278 573163276_6.doc @ 41510 @ 1222 @ 1
Page 5
About This Manual
2014-04-15 5
1 About This Manual
1.1 Scope
This manual describes how to install your (Cross) Repeater, how to operate it and how to perform trouble shooting.
1.2 Validity
This manual is valid for all devices listed on the front page. The product code is printed on the base of the devices.
1.3 Cautions and Notes
The following symbols are used in this manual:
This symbol indicates an important operating instruction that should be followed to avoid any potential damage to hardware or property, loss of data, or personal injury.
This symbol indicates important information to help you make the best use of this product.
This symbol indicates best practice information to show recommended and optimal ways to use this product in an efficient way.
Pos: 2 /806-IHSE/Sicherheitshinweis e/ATB_Sicherheits hinweise @ 5\mod_127857332 1245_6.doc @ 41528 @ 1 @ 1
Page 6
Draco (Cross) Repeater
6 2014-04-15
2 Safety Instructions
To ensure reliable and safe long-term operation of your (Cross) Repeater please note the following guidelines:
Installation
Only use in dry, indoor environments. The (Cross) Repeater and the power supply units can get warm. Do
not install components in an enclosed space without any airflow.
Do not place the power supply directly on top of the device. Do not obscure ventilation holes. Only use power supplies originally supplied with the product or
manufacturer-approved replacements. Do not use a power supply if it appears to be defective or has a damaged chassis.
Connect all power supplies to grounded outlets. In each case, ensure
that the ground connection is maintained from the outlet socket through to the power supply's AC power input.
Do not connect the link interface to any other equipment, particularly
network or telecommunications equipment.
Take any required ESD precautions.
In order to disconnect the device completely from the electric circuit, all power cables have to be removed.
Repair
Do not attempt to open or repair a power supply unit. Do not attempt to open or repair the (Cross) Repeater. There are no
user serviceable parts inside.
Please contact your dealer or manufacturer if there is a fault.
Pos: 3 /806-IHSE/Beschreibung/UEB_Besc hreibung @ 5\mod_1278 573379151_6.doc @ 41546 @ 1 @ 1
Page 7
Description
2014-04-15 7
3 Description
Pos: 4 /806-IHSE/Beschreibung/Verwen dungszweck/485-xx @ 11\ mod_1395145109102_6. doc @ 140748 @ 2 @ 1
3.1 Application
The (Cross) Repeater is basically used in order to double the maximum cabling distance between a KVM extender CON or CPU Unit or even a KVM matrix. In addition to that the device can also be used for media conversion from Cat X to fiber or vice versa.
The device is available as a pure Cat X or fiber version (repeater) and as a hybrid version of Cat X and fiber (cross repeater) for an additional electrical/optical signal conversion.
Pos: 5 /806-IHSE/Beschreibung/Syste m-Übersicht /485-xx @ 11\ mod_1395145337503_6. doc @ 140779 @ 2 @ 1
Page 8
Draco (Cross) Repeater
8 2014-04-15
3.2 System Overview
The (Cross) Repeater consists of at least one module depending on the application.
The device is connected between a KVM extender CON and CPU Unit via the interconnect cable or can be alternatively connected between a KVM extender unit and a KVM matrix.
The (Cross) Repeater communicates with both the KVM extenders and a KVM-Matrix via the interconnect cables.
1 2 4 53 761 2 4 53 76
System Overview
1 Source (computer, CPU) 2 KVM Extender CPU Unit 3 Interconnect cable (Cat X or fiber) 4 (Cross) Repeater 5 Interconnect cable (Cat X or fiber) 6 KVM Extender CON Unit 7 Console (monitor, keyboard, mouse)
See Chapter 4.3, Page 23 for installation examples.
Pos: 6 /806-IHSE/Beschreibung/Geräte typen/485-xx @ 11\mod_ 1395145641436_6.doc @ 140805 @ 233 @ 1
Page 9
Description
2014-04-15 9
3.3 Product Range
3.3.1 Chassis
Model Description
474-BODY2
Empty chassis for up to 2 boards, 1x external power supply unit
474-BODY2R
Empty chassis for up to 2 boards, 1x external power supply unit, preparation for redundancy for a second power supply unit (external)
474-BODY2N
Empty chassis for up to 2 boards, 1x internal power supply unit, preparation for redundancy for a second power supply unit (external)
474-BODY4
Empty chassis for up to 4 boards, 1x external power supply unit
474-BODY4R
Empty chassis for up to 4 boards, 1x external power supply unit, preparation for redundancy for a second power supply unit (external)
474-BODY6R
Empty chassis for up to 6 boards, 1x internal power supply unit, preparation for redundancy for a second power supply unit (external)
474­BODY6BP
Empty chassis for up to 6 boards, active backplane, 2x internal power supply unit (redundancy)
474­BODY6BPF
Empty chassis for up to 6 boards, active backplane, 2x internal power supply unit (redundancy) with connectors on rear side
474­BODY21/4U
Empty chassis for up to 21 boards, 1x internal power supply unit, preparation for redundancy for a second power supply unit (internal)
Page 10
Draco (Cross) Repeater
10 2014-04-15
3.3.2 (Cross) Repeater Modules
Model Description
485-BC Repeater module Cat X for range extension up to 280 m 485-BS
Repeater module fiber (Single-Mode) for range extension up to 20,000 m
485-BX
Repeater module Cat X/fiber (Single-Mode) for an electrical/optical media conversion, maximum extension 10,140 m
485-BCC
Dual repeater module Cat X for range extension up to 280 m
485-BSS
Dual repeater module fiber (Single-Mode) for range extension up to 20,000 m
485-BXX
Repeater module Cat X/fiber (Single-Mode) for an electrical/optical media conversion, maximum extension 10,140 m
Pos: 7 /806-IHSE/Beschreibung/Einbauop tionen/474-xx @ 6\mod_1 304580008551_6.doc @ 50839 @ 2 @ 1
3.4 Accessories Upgrade Kits
Model Description
474-2RMK 19"/1U rack mount kit for 2-fold chassis 474-
2NRMK
19"/1U rack mount kit for 2-fold chassis with internal PSU
474-4RMK 19"/1U rack mount kit for 4-fold chassis 474-6RMK 19"/1U rack mount kit for 6-fold chassis 474-
VPLATE
Fastening strips for screw or snap on for 2-, 4- and 6-fold chassis
474­OPTRED
Retrofitting for redundant power supply option (without
power supply) for 2- and 4-fold chassis 474-PSU2 Power supply for 2-fold chassis (spare or redundancy) 474-PSU4 Power supply for 4-fold chassis (spare or redundancy) 474-PSU6 Power supply for 6-fold chassis (spare or redundancy) 474-PSU21 Power supply for 6-fold-chassis (spare or redundancy) 474-BLND1 Blind plate 3U/4HP for 2-, 4- and 6-fold chassis 474-BLND2 Blind plate 3U/8HP for 2-, 4- and 6-fold chassis
Page 11
Description
2014-04-15 11
(Cross) Repeaters and the power supply units can get warm and must not be installed in closed rooms with no air circulation. For rack-mount installations, at least 0.5 U (height unit) is required above the (Cross) Repeater for ventilation.
Pos: 8 /806-IHSE/Beschreibung/Zubehör/ 485-xx @ 11\mod_139514 5995119_6.doc @ 140842 @ 2 @ 1
3.5 Accessories
Model Description
260-5G International power supply unit 100...240 VAC / 5 VDC / 3 A 260-5U International power supply unit 100...240 VAC / 5 VDC / 4 A 474-
PSULOCK
IEC connection cable for power supply, lockable
Pos: 9 /806-IHSE/Beschreibung/Gerätean sichten/UEB_Ger äteansichten @ 5\mod_127 8573737808_6.doc @ 41654 @ 2 @ 1
3.6 Device Views
Pos: 10 /806-IHSE/Beschreibung/Gerätea nsichten/474- xx/2-fach Vario- Gehäuse 474-BODY2/2R @ 6\mod_1 304580280566_6.doc @ 508 58 @ 3 @ 1
3.6.1 2-fold Vario Chassis 474-BODY2/2R
CPU and CON Unit
1
2
3
4
Rear View
1 Slot for modules #1 2 Connect to 5VDC power supply (standard) 3 Slot for modules #2 4 Connect to 5VDC power supply (redundancy, optional)
Pos: 11 /806-IHSE/Beschreibung/Gerätea nsichten/474- xx/2-fach Vario- Gehäuse 474-BODY2N @ 8\mod_13485 78478411_6.doc @ 6938 0 @ 3 @ 1
Page 12
Draco (Cross) Repeater
12 2014-04-15
3.6.2 2-fold Vario Chassis 474-BODY2N
CPU and CON Unit
1
2
3
4
Rear View
1 Slot for modules #1 2 Connect to power supply (standard) 3 Slot for modules #2 4 Connect to 5VDC power supply (redundancy)
The 2-fold vario chassis with an internal power supply is not equipped with a fuse on its primary side. Therefore the protection against excessive currents has to be provided by the electrical installation of the building.
Pos: 12 /806-IHSE/Beschreibung/Gerätea nsichten/474- xx/4-fach Vario- Gehäuse 474-BODY4/4R @ 6\mod_1 304580359098_6.doc @ 508 76 @ 3 @ 1
Page 13
Description
2014-04-15 13
3.6.3 4-fold Vario Chassis 474-BODY4/4R
CPU and CON Unit
3
4
5
1
2
6
Rear View
1 Slot for modules #3 2 Slot for modules #1 3 Connect to 5VDC power supply (standard) 4 Slot for modules #4 5 Slot for modules #2 6 Connect to 5VDC power supply (redundancy, optional)
For operation with three KVM Extender CON modules and a USB 2.0 CON module in a 4-fold vario chassis, two power supplies are necessary. In this case, redundancy is inapplicable.
Pos: 13 /806-IHSE/Beschreibung/Gerätea nsichten/474- xx/6-fach Vario- Gehäuse 474-BODY6R @ 6\mod_13045 80442488_6.doc @ 5089 4 @ 3 @ 1
Page 14
Draco (Cross) Repeater
14 2014-04-15
3.6.4 6-fold Vario Chassis 474-BODY6R
CPU and CON Unit
3
4
5
1
2
6
8
7
Rear View
1 Slot for modules #5 2 Slot for modules #3 3 Slot for modules #1 4 Connect to power supply (standard) 5 Connect to 5VDC power supply (standard) 6 Slot for modules #6 7 Slot for modules #4 8 Slot for modules #2
For operation with KVM Extender modules in a 6-fold vario chassis, two power supplies are necessary. In this case, redundancy is inapplicable.
The 6-fold vario chassis is not equipped with a fuse on its primary side. Therefore the protection against excessive currents has to be provided by the electrical installation of the building.
Pos: 14 /806-IHSE/Beschreibung/Gerätea nsichten/481- xx/6-fach Vario- Gehäuse 474-BODY6BP @ 9\mod_1367 827188730_6.doc @ 71694 @ 3 @ 1
Page 15
Description
2014-04-15 15
3.6.5 6-fold Vario Chassis 474-BODY6BP
CPU and CON Unit
123
Front View
1 Connect to power supply 1 2 Connect to power supply 2 (redundancy) 3 Grounding
3
45
1
2
6
Rear View
1 Slot for modules #5 2 Slot for modules #3 3 Slot for modules #1 4 Slot for modules #6 5 Slot for modules #4 6 Slot for modules #2
Pos: 15 /806-IHSE/Beschreibung/Gerätea nsichten/474- xx/6-fach Vario- Gehäuse 474-BODY6BPF @ 11\mod_13 92644763729_6.doc @ 132650 @ 3 @ 1
Page 16
Draco (Cross) Repeater
16 2014-04-15
3.6.6 6-fold Vario Chassis 474-BODY6BPF
CPU and CON Unit
3
67
1
2
8
4 5
Rear View
1 Slot for modules #5 2 Slot for modules #3 3 Slot for modules #1 4 Connect to power supply 1 5 Connect to power supply 2 (redundancy) 6 Slot for modules #2 7 Slot for modules #4 8 Slot for modules #6
Pos: 16 /806-IHSE/zz_Layout/Seitenu mbruch @ 8\mod_134858182051 6_0.doc @ 69462 @ @ 1
Page 17
Description
2014-04-15 17
Pos: 17 /806-IHSE/Beschreibung/Gerätea nsichten/474- xx/21-fach Vario- Gehäuse 474-BODY21R @ 8\mod_134 8579151346_6.doc @ 69400 @ 3 @ 1
3.6.7 21-fold Vario Chassis 474-BODY21R
CPU and CON Unit
1
Rear View
1 Slots for modules #1 - #21
1
2
3
4
Front View
1 Connect to power supply 2 2 Locking for power supply 2 (redundancy) 3 Locking for power supply 1 (standard) 4 Connect to power supply 1
Pos: 18 /806-IHSE/Beschreibung/Gerätea nsichten/485- xx/485-BC @ 11\mod_13951500 15320_6.doc @ 140874 @ 3 @ 1
Page 18
Draco (Cross) Repeater
18 2014-04-15
3.6.8 Model 485-BC
Module
12 3
Rear View
1 Service port 2 Connect to interconnect cable 1 3 Connect to interconnect cable 2
Pos: 19 /806-IHSE/Beschreibung/Gerätea nsichten/485- xx/485-BS @ 11\mod_1395151 298709_6.doc @ 140905 @ 3 @ 1
3.6.9 Model 485-BS
Module
12 3
Rear View
1 Service port 2 Connect to interconnect cable 1 3 Connect to interconnect cable 2
Pos: 20 /806-IHSE/Beschreibung/Gerätea nsichten/485- xx/485-BX @ 11\mod_1395153 879791_6.doc @ 140936 @ 3 @ 1
3.6.10 Model 485-BX
Module
12 3
Rear View
1 Service port 2 Connect to interconnect cable 1 3 Connect to interconnect cable 2
Pos: 21 /806-IHSE/Beschreibung/Gerätea nsichten/485- xx/485-BCC @ 11\mod_1395153 925309_6.doc @ 140967 @ 3 @ 1
Page 19
Description
2014-04-15 19
3.6.11 Model 485-BCC
Module
142 3 65
Rear View
1 Service port (repeater #1) 2 Connect to interconnect cable 1
(repeater #1)
3 Connect to interconnect cable 2
(repeater #1) 4 Service port (repeater #2) 5 Connect to interconnect cable 1
(repeater #2) 6 Connect to interconnect cable 2
(repeater #2)
Pos: 22 /806-IHSE/Beschreibung/Geräteansi chten/485-xx/485- BSS @ 11\mod_1395154011282_ 6.doc @ 140998 @ 3 @ 1
3.6.12 Model 485-BSS
Module
2 3 5 6
14
Rear View
1 Service port (repeater #1) 2 Connect to interconnect cable 1
(repeater #1) 3 Connect to interconnect cable 2
(repeater #1) 4 Service port (repeater #2) 5 Connect to interconnect cable 1
(repeater #2) 6 Connect to interconnect cable 2
(repeater #2)
Pos: 23 /806-IHSE/Beschreibung/Geräteansi chten/485-xx/485- BXX @ 11\mod_1395154080863_ 6.doc @ 141029 @ 3 @ 1
Page 20
Draco (Cross) Repeater
20 2014-04-15
3.6.13 Model 485-BXX
Module
2 3 5 6
14
Rear View
1 Service port (repeater #1) 2 Connect to interconnect cable 1
(repeater #1) 3 Connect to interconnect cable 2
(repeater #1) 4 Service port (repeater #2) 5 Connect to interconnect cable 1
(repeater #2) 6 Connect to interconnect cable 2
(repeater #2)
Pos: 24 /806-IHSE/Beschreibung/Diagnos e LEDs/UEB_Diagnose_LE Ds @ 6\mod_13045840047 23_6.doc @ 51146 @ @ 1
Page 21
Description
2014-04-15 21
3.7 Status LEDs
Pos: 25 /806-IHSE/Beschreibung/Diagnos e LEDs/485-xx @ 11\mod_13 95154726794_6.doc @ 141055 @ 3 @ 1
3.7.1 Status (Cross) Repeater Module
The (Cross) Repeater module is fitted with a multi color LED for overall status indication and with two further LEDs for indication of the connection status.
Module
12345
12 3 45
12345
Rear View Rear View
LED 1/2 and 4/5: Connection Status
Pos. LED Status Description
Off Connection available 1/4
Failure LED
(green)
On or Flashing
Connection failure (flashing for about 20 s following a connection failure)
Flashing No connection via interconnect cable 2/5
Status LED
(green)
On Connection available
LED 3: Device Status
LED color Description
Red Device ready
Blue
Link 1 (left connector) available, Link 2 (right connector) not detected
Green
Link 2 (right connector) available, Link 1 (left connector) not detected
Light Blue
Link 1 (left connector) and Link 2 (right connector) available
Pos: 26 /806-IHSE/Installation/UEB_I nstallation @ 5\mod_12 78574971589_6.doc @ 41768 @ 1 @ 1
Page 22
Draco (Cross) Repeater
22 2014-04-15
4 Installation
Pos: 27 /806-IHSE/Installation/Liefer umfang prüfen/48 5-xx @ 11\mod_139515521 6299_6.doc @ 141092 @ 2 @ 1
4.1 Package Contents
Your extender package contains the following items:
(Cross) Repeater:
(Cross) Repeater in the vario chassis  1x (redundancy 2x) 5 VDC international power supply unit per KVM
Extender unit (depending on chassis) 1x (redundancy 2x) country-specific power cord (depending on
chassis) Quick Setup
If anything is missing, contact your dealer.
Pos: 28 /806-IHSE/Installation/Syst em anschließen/485- xx @ 11\mod_1395155663403_ 6.doc @ 141123 @ 23 @ 1
4.2 System anschließen
First time users are recommended to setup the system in the same room as a test setup. This will allow you to identify and solve any cabling problems, and experiment with your system more conveniently.
Please verify that interconnect cables, interfaces, and handling of the
devices comply with the requirements (see Chapter
7, Page 26).
4.2.1 (Cross) Repeater Setup
1. Switch off all devices.
2. Connect the (Cross) Repeater with the interconnect cable(s).
3. Connect the chassis of the (Cross) Repeater to the power supply.
4. Power up the system.
To power up the system, the following sequence is recommended: Monitor – CON Unit – (Cross) Repeater – CPU Unit – source.
Pos: 29 /806-IHSE/Installation/Ins tallationsbeispi ele/485-xx @ 11\mod_139 5156295171_6.doc @ 141154 @ 2 @ 1
Page 23
Installation
2014-04-15 23
4.3 Example Applications
This section illustrates typical installations of (Cross) Repeaters:
Pos: 58 /806-IHSE/Installation/Ins tallationsbeispi ele/477-xx_COMP @ 5\ mod_1291124264328_258. doc @ 44766 @ @ 1
1 2 4 53 761 2 4 53 76
Single Media Conversion
1 Source (computer, CPU) 2 KVM Extender CPU Unit 3 Interconnect cable (Cat X) 4 (Cross) Repeater 5 Interconnect cable (fiber) 6 KVM Extender CON Unit 7 Console (monitor, keyboard, mouse)
The example shown in this application scenario will be primarily recommended, if connections through KVM matrix must be bypassed in case of major matrix problems. Therefore KVM extenders with Cat X and with fiber connector can be directly connected to each other.
Page 24
Draco (Cross) Repeater
24 2014-04-15
1 2 4 5 83 7 96
Pos: 46 /806-IHSE/zz_Layout/Seitenu mbruch @ 8\mod_134858182051 6_0.doc @ 69459 @ @ 1
Dual Media Conversion
1 Source (computer, CPU) 2 KVM Extender CPU Unit 3 Interconnect cable (Cat X) 4 (Cross) Repeater #1 5 Interconnect cable (fiber) 6 (Cross) Repeater #2 7 Interconnect cable (Cat X) 8 KVM Extender CON Unit 9 Console (monitor, keyboard, mouse)
Pos: 30 /806-IHSE/Konfiguration/ UEB_Konfiguration @ 5\mod_127 8575517073_6.doc @ 41846 @ 1 @ 1
Page 25
Configuration
2014-04-15 25
5 Configuration
Pos: 31 /806-IHSE/Konfiguration/485 _Einleitung @ 11\mod_13 95156666210_6.doc @ 141185 @ @ 1
The (Cross) Repeater does not require any configuration and is ready for use per default.
Pos: 32 /806-IHSE/Betrieb/UEB_Betri eb @ 5\mod_1278577614980_6. doc @ 41970 @ 1 @ 1
6 Operation
Pos: 33 /806-IHSE/Betrieb/485_Einlei tung @ 11\mod_13951567253 31_6.doc @ 141216 @ @ 1
The (Cross) Repeater does not have any adjustable operating modes and is ready for use per default.
Pos: 34 /806-IHSE/Technische Daten/UEB_ Technische Daten @ 5\mod_12 78578165261_6.doc @ 42096 @ 1 @ 1
Page 26
Draco (Cross) Repeater
26 2014-04-15
7 Specifications
Pos: 35 /806-IHSE/Technische Daten/Sc hnittstellen/UEB_Sc hnittstellen @ 5\mod_12 78578201870_6.doc @ 42114 @ 2 @ 1
7.1 Interfaces
Pos: 36 /806-IHSE/Technische Daten/Sc hnittstellen/RJ45 (G erätekommunikation) @ 5\mod_1278578339308 _6.doc @ 42186 @ 3 @ 1
7.1.1 RJ45 (Interconnect)
Communication between Cat X devices requires a 1000BASE-T connection.
Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with RJ45 connectors at both ends. All four cable wire pairs are used.
Pos: 37 /806-IHSE/Technische Daten/Sc hnittstellen/Glasf aser SFP Typ LC @ 5\mod_127893 7700855_6.doc @ 43149 @ 3 @ 1
7.1.2 Fiber SFP Type LC (Interconnect)
Communication of fiber devices is performed via Gigabit SFPs that are connected to suitable fibers fitted with connectors type LC (see
Chapter 7.2.2, Page 28).
The correct function of the device can only be guaranteed with SFPs provided by the manufacturer.
SFP modules can be damaged by electrostatic discharge (ESD). Please consider ESD handling specifications.
Pos: 38 /806-IHSE/Technische Daten/Verbi ndungskabel/UEB_V erbindungskabel @ 5\ mod_1279191107845_6.d oc @ 43870 @ 2 @ 1
Page 27
Specifications
2014-04-15 27
7.2 Interconnect Cable
Pos: 39 /806-IHSE/Technische Daten/Verbi ndungskabel/Verbi ndungskabel (Cat X) @ 5\ mod_1278578406026_6.doc @ 42205 @ 3 @ 1
7.2.1 Cat X
A point-to-point connection is required. Operation with several patch fields is possible. Routing over an active network component, such as an Ethernet Hub, Router or Matrix, is not allowed.
Avoid routing Cat X cables along power cables. If the site has 3-phase AC power, try to ensure that CPU Unit and
CON Unit are on the same phase.
To maintain regulatory EMC compliance, correctly installed shielded Cat X cable must be used throughout the interconnection link.
To maintain regulatory EMC compliance, all Cat X cables need to carry ferrites on both cable ends close to the device.
Type of Interconnect Cable
The (Cross) Repeater requires interconnect cabling specified for Gigabit Ethernet (1000BASE-T). The use of solid-core (AWG24), shielded, Cat 5e (or better) is recommended.
Cat X Solid-Core Cable AWG24
S/UTP (Cat 5e) cable according to EIA/TIA­568-B. Four pairs of wires AWG24. Connection according to EIA/TIA-568-B (1000BASE-T).
Cat X Patch Cable AWG26/8
S/UTP (Cat 5e) cable according to EIA/TIA­568-B. Four pairs of wires AWG26/8. Connection according to EIA/TIA-568-B (1000BASE-T).
The use of flexible cables (patch cables) type AWG26/8 is possible, however the maximum possible extension distance is halved.
Pos: 40 /806-IHSE/Technische Daten/Verbi ndungskabel/Verbi ndungskabel (Cat X)_Kab ellänge 477- xx @ 5\mod_1278937761105_6. doc @ 43167 @ @ 1
Maximum Acceptable Cable Length
Cat X Installation Cable AWG24
140 m (400 ft)
Cat X Patch Cable AWG26/8
70 m (200 ft)
Pos: 41 /806-IHSE/Technische Daten/Verbi ndungskabel/Verbi ndungskabel (LW L) @ 5\mod_1278937967667_6. doc @ 43186 @ 3 @ 1
Page 28
Draco (Cross) Repeater
28 2014-04-15
7.2.2 Fiber
A point-to-point connection is necessary. Operation with multiple patch panels is allowed. Routing over active network components, such as Ethernet Hubs, Switches or Routers, is not allowed.
Type of Interconnect Cable
(Cable notations according to VDE)
Type of cable Specifications
Single-mode 9μm Two fibers 9μm
I-V(ZN)H 2E9 (in-house patch cable)  I-V(ZN)HH 2E9 (in-house breakout cable)  I/AD(ZN)H 4E9 (in-house or outdoor
breakout cable, resistant)
A/DQ(ZN)B2Y 4G9 (outdoor cable, with
protection against rodents)
Multi-mode 50μm Two fibers 50μm
I-V(ZN)H 2G50 (in-house patch cable)  I/AD(ZN)H 4G50 (in-house or outdoor
breakout cable, resistant)
Multi-mode 62.5μm Two fibers 62.5μm
I-V(ZN)HH 2G62.5 (in-house breakout
cable)
A/DQ(ZN)B2Y 4G62.5 (outdoor cable,
with protection against rodents)
Maximum Acceptable Cable Length
Type of cable Maximum Acceptable Cable Length
Single-mode 9μm 10,000 m (32,800 ft) Multi-mode 50μm (OM3) 1,000 m (3,280 ft) Multi-mode 50μm 400 m (1,300 ft) Multi-mode 62.5μm 200 m (650 ft)
If you use single-mode SFPs with multi-mode fibers, you normally can double the maximum acceptable cable length.
Pos: 42 /806-IHSE/Technische Daten/Verbi ndungskabel/Verbi ndungskabel (LW L)_Steckverbinder 477- xx @ 5\mod_1278954447542 _6.doc @ 43740 @ @ 1
Type of Connector
Connector
LC Connector
Pos: 43 /806-IHSE/Technische Daten/Pinbe legungen/UEB_Pinb elegungen @ 5\mod_12785 78683636_6.doc @ 42315 @ 2 @ 1
Page 29
Specifications
2014-04-15 29
7.3 Connector Pinouts
Pos: 44 /806-IHSE/Technische Daten/Pinbe legungen/Buchse Mini-USB Typ B @ 5\mod_127857879 4167_6.doc @ 42387 @ @ 1
Connector Mini USB Type B
Picture Pin Signal Color
1 VCC (+5VDC) Red 2 Data White 3 Data + Green 4 n.c.
....5
1
5 GND Black
Pos: 45 /806-IHSE/Technische Daten/Pinbe legungen/RJ45 @ 5\mod_1 278578820011_6.doc @ 42405 @ @ 1
RJ45
Picture Pin Signal Pin Signal
1 D1+ 5 D3–
2 D1– 6 D2–
3 D2+ 7 D4+
8..........1
4 D3+ 8 D4–
Pos: 46 /806-IHSE/Technische Daten/Pinbe legungen/Glasfaser SFP Typ LC @ 5\mod_127893850 1151_6.doc @ 43210 @ @ 1
Fiber SFP Typ LC
Picture Diode Signal
1 Data OUT
12
2 Data IN
Pos: 47 /806-IHSE/Technische Daten/Stro mversorgung/485- xx @ 11\mod_139515734124 2_6.doc @ 141242 @ 2 @ 1
Page 30
Draco (Cross) Repeater
30 2014-04-15
7.4 Power Supply
AC Power Supply
Model Max. Current Max. Voltage Frequency
474-BODY2N 700 mA max. 100-240 V 50/60 Hz
474-BODY6R 1,400 mA max. 100-240 V 47-63 Hz 474-BODY6BP 800 mA max. 100-240 V 50/60 Hz 474-BODY6BPF 800 mA max. 100-240 V 50/60 Hz 474-BODY21/4U 4,000 mA max. 2x 100-240 V 50/60 Hz
DC Power Supply
Model Max. Current Max. Voltage
474-BODY2/2R 3,000 mA 5 VDC 474-BODY2N 5,000 mA 5 VDC 474-BODY4/4R 5,000 mA 5 VDC 474-BODY6R 8,000 mA 5 VDC
Power Requirement
Power Requirement (per Unit)
(Cross) Repeater:
Max. 300 mA
Pos: 48 /806-IHSE/Technische Daten/Einsa tzbedingungen/A TB_Einsatzbedingung en @ 5\mod_1278578980026 _6.doc @ 42480 @ 2 @ 1
7.5 Environmental Conditions
Operating Temperature
41 to 113°F (5 to 45°C)
Storage Temperature
–13 to 140°F (–25 to 60°C)
Relative Humidity
Max. 80% non-condensing
Pos: 49 /806-IHSE/Technische Daten/Ab messungen/474-xx @ 6\mod _1304586358176_6.doc @ 51345 @ 2 @ 1
Page 31
Specifications
2014-04-15 31
7.6 Size
Devices in the 2-fold Vario Chassis 1
CPU Unit / CON Unit
145 x 147 x 41 mm (5.7" x 5.8" x 1.7")
Shipping Box
210 x 140 x 165 mm (8.3" x 5.5" x 6.5")
Devices in the 2-fold Vario Chassis 2
CPU Unit / CON Unit
221 x 147 x 41 mm (8.7" x 5.8" x 1.7")
Shipping Box
550 x 365 x 115 mm (21.7" x 14.4" x 4.5")
Devices in the 4-fold Vario Chassis
CPU Unit / CON Unit
293 x 147 x 41 mm (11.5" x 5.8" x 1.7")
Shipping Box
550 x 365 x 115 mm (21.7" x 14.4" x 4.5")
Devices in the 6-fold Vario Chassis 6R
CPU Unit / CON Unit
442 x 147 x 41 mm (17.4" x 5.8" x 1.7")
Shipping Box
760 x 365 x 115 mm (29.9" x 14.4" x 4.5")
Devices in the 6-fold Vario Chassis 6BP / 6BPF
CPU Unit / CON Unit
442 x 250 x 41 mm (17.4" x 9.8" x 1.7")
Shipping Box
550 x 372 x 155 mm (21.7" x 14.6" x 6.1")
Devices in the 21-fold Vario Chassis
CPU Unit / CON Unit
482 x 462 x 176 mm (19.0" x 18.2" x 6.9")
Shipping Box
645 x 574 x 368 mm (25.4" x 22.6" x 14.5")
Pos: 50 /806-IHSE/zz_Layout/Seitenu mbruch @ 8\mod_134858182051 6_0.doc @ 69462 @ @ 1
Page 32
Draco (Cross) Repeater
32 2014-04-15
Pos: 51 /806-IHSE/Technische Daten/Transp ortgewicht /474- xx @ 6\mod_1304586413879_ 6.doc @ 51363 @ 2 @ 1
7.7 Shipping Weight
Devices in the 2-fold Vario Chassis 1
CPU Unit / CON Unit
0.4 kg (0.9 lb)
Shipping Box
2.2 kg (4.9 lb)
Devices in the 2-fold Vario Chassis 2
CPU Unit / CON Unit
0.8 kg (1.8 lb)
Shipping Box
2.6 kg (5.7 lb)
Devices in the 4-fold Vario Chassis
CPU Unit / CON Unit
0.9 kg (2.0 lb)
Shipping Box
3.4 kg (7.5 lb)
Devices in the 6-fold Vario Chassis 6R
CPU Unit / CON Unit
1.4 kg (3.1 lb)
Shipping Box
4.6 kg (10.1 lb)
Devices in the 6-fold Vario Chassis 6BP / 6BPF
CPU Unit / CON Unit
2.5 kg (5.5 lb)
Shipping Box
3.5 kg (7.7 lb)
Devices in the 21-fold Vario Chassis
CPU Unit / CON Unit
10.0 kg (22.1 lb)
Shipping Box
14.5 kg (32.0 lb)
Pos: 52 /806-IHSE/Hilfe im Problemfall/ UEB_Hilfe im Problemfal l @ 5\mod_1278579113839_ 6.doc @ 42536 @ 1 @ 1
Page 33
Troubleshooting
2014-04-15 33
8 Troubleshooting
Pos: 53 /806-IHSE/Hilfe im Problemfall/A llgemeine Störung/48 5-xx @ 11\mod_139521879 3981_6.doc @ 141316 @ 2 @ 1
8.1 General Failures
Module
12345
12 3 45
12345
Rear View
Diagnosis Possible Reason Measure
LED 3 off
Power supply
Check power supply units and
the connection to the power network.
LED 2 off or LED 5 off
Connection between (Cross) Repeater and KVM extender unit or KVM matrix
Check interconnect cables and
connections.
Pos: 54 /806-IHSE/Technische Unterstütz ung/ATB_Technisc he Unterstützung @ 5\mod_1 278579487089_6.doc @ 42650 @ 122 @ 1
Page 34
Draco (Cross) Repeater
34 2014-04-15
9 Technical Support
Prior to contacting support please ensure you have read this manual, and then installed and set-up your (Cross) Repeater as recommended.
9.1 Support Checklist
To efficiently handle your request it is necessary that you complete a support request checklist (Download). Please ensure that you have the following information available before you call:
Company, name, phone number and email  Type and serial number of the device (see bottom of device)  Date and number of sales receipt, name of dealer if necessary  Issue date of the existing manual  Nature, circumstances and duration of the problem  Components included in the system (such as graphic source/CPU,
OS, graphic card, monitor, USB-HID/USB 2.0 devices, interconnect
cable) including manufacturer and model number Results from any testing you have done
9.2 Shipping Checklist
1. To return your device, contact your dealer to obtain a RMA number
(Return-Material-Authorization).
2. Package your devices carefully, preferably using the original box.
Add all pieces which you received originally.
3. Note your RMA number visibly on your shipment.
Devices that are sent in without a RMA number cannot be accepted. The shipment will be sent back without being opened, postage unpaid.
Pos: 55 /806-IHSE/Zertifikate/UEB_ Zertifikate @ 5\mod_12785 79534933_6.doc @ 42668 @ 1 @ 1
Page 35
Certificates
2014-04-15 35
10 Certificates
Pos: 56 /806-IHSE/Zertifikate/ATB_E uropäische Konformi tätserklärung @ 5\mod_1 278579640901_6.doc @ 42686 @ 2 @ 1
10.1 CE Declaration Of Conformity
The products listed below in the form as delivered comply with the provisions of the following European Directives:
2004/108/EG Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility
CE Marking 2009 Product list: 485 Series
The products comply with the following harmonized standards for Information Technology Equipment:
EN 55022:2010 + A1:2007 (Class A)  EN 55024:2010 + A1:2001 + A2:2003
This declaration certifies the conformity to the specified directives but contains no assurance of properties. The safety instructions and installation guidelines noted in this manual shall be considered in detail. Compliance with the specifications for cable lengths and types is mandatory.
Manufacturer: IHSE GmbH
Maybachstrasse 11 88094 Oberteuringen Deutschland
Oberteuringen, 26 January 2010 The Management
Use in a Domestic Environment
This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.
Page 36
Draco (Cross) Repeater
36 2014-04-15
10.2 North American Regulatory Compliance
This equipment has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances.
All power supplies are certified to the relevant major international safety standards.
Pos: 57 /806-IHSE/Zertifikate/474- xx_Produktsicher heit @ 9\mod_13739646017 86_6.doc @ 77511 @ 2 @ 1
10.3 Product Safety
The product safety of the devices is proven by the compliance to the following standards:
IEC 60950-1A1:2010 EN 60950-1/A12:2011 UL 60950-1-2007 CAN/CSA-C22.2 60950-1-07
The compliance is verified and confirmed by TÜV Süd, Germany.
Pos: 58 /806-IHSE/Zertifikate/ATB_WEEE @ 5\ mod_1278579673292_6.doc @ 42704 @ 2 @ 1
Page 37
Certificates
2014-04-15 37
10.4 WEEE
The manufacturer complies with the EU Directive 2012/19/EU on the prevention of waste electrical and electronic equipment (WEEE).
The device labels carry a respective marking.
Pos: 59 /806-IHSE/Zertifikate/ATB_ RoHS @ 5\mod_1278579714214_6. doc @ 42722 @ 2 @ 1
10.5 RoHS/RoHS 2
This device complies with the Directive 2011/65/EU of the European Parliament and of the council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2, RoHS II).
The device labels carry a respective marking.
Pos: 60 /806-IHSE/Glossar/ATB_Glossar @ 5\mod_1278576825433_ 6.doc @ 41890 @ 1 @ 1
Page 38
Draco (Cross) Repeater
38 2014-04-15
11 Glossary
The following terms are commonly used in this guide or in video and KVM technology:
Term Explanation
AES/EBU
Digital audio standard that is officially known as AES3 and that is used for carrying digital audio
signals between devices. Cat X Any Cat 5e (Cat 6, Cat 7) cable CGA
Color Graphics Adapter (CGA) is an old analog
graphic standard with up to 16 displayable colors and
a maximum resolution of 640x400 pixels. Component
Video
Component Video (YPbPr) is a high-quality video
standard that consists of three independently and
separately transmittable video signals, the luminance
signal and two color difference signals. Composite Video
Composite Video is also called CVBS and it is part of
the PAL TV standard. CON Unit
Component of a KVM Extender or Media Extender to
connect to the console (monitor(s), keyboard and
mouse; optionally also with USB 2.0 devices) Console Keyboard, mouse and monitor CPU Unit
Component of a KVM Extender or Media Extender to
connect to a source (computer, CPU) CVBS
The analog color video baseband signal (CVBS) is
also called Composite Video and it is part of the PAL
TV standard. DDC
Display Data Channel (DDC) is a serial
communication interface between monitor and
source (computer, CPU). It allows a data exchange
via monitor cable and an automatic installation and
configuration of a monitor driver by the operating
system. Dual Access
A system to operate a source (computer, CPU) from
two consoles Dual Link
A DVI-D interface for resolutions up to 2560x2048 by
signal transmission of up to 330 MPixel/s (24-bit) Dual-Head A system with two video connections
Page 39
Glossary
2014-04-15 39
Term Explanation
DVI
Digital video standard, introduced by the Digital
Display Working Group (http://www.ddwg.org
). Single Link and Dual Link standard are distinguished. The signals have TMDS level.
DVI-I
A combined signal (digital and analog) that allows running a VGA monitor at a DVI-I port – in contrast to DVI-D (see DVI).
EGA
The Enhanced Graphics Adapter (EGA) is an old analog graphic standard, introduced by IBM in 1984. A D-Sub 9 connector is used for connection.
Fiber Single-mode or multi-mode fiber cables HDMI
An interface for an all-digital transmission of audio and video data. It is differentiated between the HDMI standards 1.0 to 1.4a.
The signals have TMDS level.
KVM Keyboard, video and mouse Mini-XLR
Industrial standard for electrical plug connections (3 pole) for the transmission of digital audio and control signals
Multi-mode
62.5µ multi-mode fiber cable or 50µ multi-mode fiber cable
OSD
The On-Screen-Display is used to display information or to operate a device.
Quad-Head A system with four video connections RCA (Cinch)
A non-standard plug connection for transmission of electrical audio and video signals, especially with coaxial cables
S/PDIF
A digital audio interconnect that is used in consumer audio equipment over relatively short distances.
SFP
SFPs (Small Form Factor Pluggable) are pluggable interface modules for Gigabit connections. SFP modules are available for Cat X and fiber interconnect cables.
Single Link
A DVI-D interface for resolutions up to 1920x1200 by signal transmission of up to 165 MPixel/s (24-bit).
Alternative frequencies are Full HD (1080p), 2K HD (2048x1080) and 2048x1152.
Single-Head A system with one video connection Single-mode 9µ single-mode fiber cable
Page 40
Draco (Cross) Repeater
40 2014-04-15
Term Explanation
S-Video (Y/C)
S-Video (Y/C) is a video format transmitting luminance and chrominance signals separately. Thereby it has a higher quality standard than CVBS.
TOSLINK
Standardized fiber connection system for digital transmission of audio signals (F05 plug connection)
Triple-Head A system with three video connections USB-HID
USB-HID devices (Human Interface Device) allow for data input.
There is no need for a special driver during installation; "New USB-HID device found" is reported.
Typical HID devices include keyboards, mice, graphics tablets and touch screens. Storage, video and audio devices are not HID.
VGA
Video Graphics Array (VGA) is a computer graphics standard with a typical resolution of 640x480 pixels and up to 262,144 colors. It can be seen as a follower of the graphics standards MDA, CGA and EGA.
=== Ende der Liste für Textmarke Inhalt ===
Loading...