212iL
1 |
6060720 Rev. 1.1 |
International Electronics, Inc.
427 Turnpike Street
Canton, Massachusetts 02021
212iL (illuminated Luxury) Keypad
Single Unit KeypadControl Installation Manual
Features:
v120 User Capability
vIlluminated Backlit Hardened Keys
vProgrammable 00-99 Second Relay Activation Time
vRemote Trigger Input (REX)
vHeavy Traffic Application
vFlush Mount
vIndoor Applications
Installation:
qSection 1: Unpacking and checking the packing list
qSection 2: Mounting the 212iL
qSection 3: Wiring the 212iL
qSection 4: Power Up
qSection 5: Programming the 212iL
qSection 6: Troubleshooting
qSection 1: Unpacking and checking the packing list
Open the box, and inside you will find:
1 212iL keypad
16 Wire conductor harness
21 1/4" black, socket cap flat head machine screws
21 1/4" black, Phillips flat head sheet metal screws
111/64" Allen wrench
1Installation Manual for 212iL
Please check the contents of this package and verify all components in the packing list are present.
Taking this inventory will familiarize you with the components as well as ensure that you have a complete parts list.
q Section 2: Mounting the 212iL |
(212iL Dimensions: 3 3/8" x 5 1/8" x 5/8") |
1. Select the appropriate location for the 212iL. Mounting height is the same for an electrical switch, 48" on center. Be sure that the 212iL is mounted indoors ONLY!
48"
2 |
6060720 Rev. 1.1 |
The 212iL should be mounted to a standard single gang electrical box (with the small slot in the trim ring facing down), but it also is able to mount directly to a flat indoor surface with the provided mounting screws.
q Section 3: Wiring
Electrical Specifications:
Operating Voltages: 12-24 VDC only on input voltage. Maximum Current Draw @ allowed voltages: 140mA. Temperature Tolerance: Standard, -20° to 130°F.
1.Attach the 6-conductor wire harness to the plug in connector on the back of the 212iL.
2.Next you will need to attach the relay wires (white/yellow, blue, and brown) to the wire run that is connected to the locking device.
Brown (N/O) Wire
Blue (Common) Wire
White/Yellow (N/C) Wire
White/Black (REX) Wire
Black (Negative) Wire Input
Red (Positive) Wire Input
Wiring to a Magnetic Lock: (see below)
If you are sharing the same DC voltage power supply with the 212iL and the magnetic lock, (that is to say if you have only one power supply for both the 212iL and the lock device), you need to run voltage through the common (Blue) wire on the 6 conductor wire harness of the 212iL. The reason is that the 212iL is equipped with a Form C, Dry contact relay on board. This means that there is no voltage running through the relay. (Until you supply the common leg of the relay with voltage).
Step 1: Splice together the Blue Relay Common wire from the 212iL harness to the Red wire on the 212iL harness. (Positive voltage coming from the power supply.)
Step 2: Connect the White /Yellow wire (Normally Closed) from the 212iL harness to the Positive connection on the Magnetic lock.
Step 3: Splice together the Black Negative voltage wire on the 212iL harness (negative voltage coming from the power supply) to the Negative connection on the Magnetic lock.
Blue (C) Wire
White/Yellow (N/C) Wire
|
|
|
|
Magnetic Lock |
|
|
V+ |
|
|
|
(Fail Safe) |
|
|
|
|
|
|
|
|
|
V- |
|
V- |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
V+ |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wiring to an Electric Strike: (see below)
If you are sharing the same DC voltage power supply with the 212iL and the Electric Strike, (that is to say if you have only one power supply for both the 212iL and the lock device), you need to run voltage through the common (Blue) wire on the 6 conductor wire harness of the 212iL. The reason is that
3 |
6060720 Rev. 1.1 |
the 212iL is equipped with a Form C, Dry contact relay on board. This means that there is no voltage running through the relay. (Until you supply the common leg of the relay with voltage).
Step 1: Splice together the Blue Relay Common wire from the 212iL harness to the Red wire on the 212iL harness. (Positive voltage coming from the power supply.)
Step 2: Connect the Brown (Normally Open) wire from the 212iL harness to the Positive voltage connection on the Electric door strike.
Step 3: Splice together the Black Negative voltage wire on the 212iL harness (negative voltage coming from the power supply) to the Negative connection on the Electric door strike.
Blue (C) Wire
Electric Strike
(Fail Secure)
Brown (N/O)
Wire
V+
V-
V+
V-
Shunting a Normally Closed Zone: (see below)
Step 1: Connect the Blue (Common) Relay wire from the 212iL harness to the Common connection on the door position switch.
Step 2: Connect the Brown (Normally Open) Relay wire from the 212iL harness to the Normally closed connection on the Door position switch.
|
|
Brown (N/O) |
|
|
|
|
|
|
Wire |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
To Alarm Panel |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
Normally |
|
|
|
|
|
|
Closed |
|
V+ |
|
|
|
|
||
|
|
|
|
Door |
||
V- |
|
|
|
|
Position |
|
|
|
|
|
|
Contacts |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
Blue (Common) Wire
To Alarm Panel