GE1A Series |
Timers |
|
|
<![endif]>Switches & Pilot Lights
<![if ! IE]><![endif]>Display Lights
<![if ! IE]><![endif]>Relays & Sockets
<![if ! IE]><![endif]>Timers
<![if ! IE]><![endif]>Terminal Blocks
<![if ! IE]><![endif]>Circuit Breakers
GE1A Series — ON Delay Timers
Single Function
Key features of the GE1A series include:
•DPDT or SPDT + instantaneous SPDT
•8-pin, octal base
•8 time ranges
•Repeat error ±0.2% maximum
•Large, clear knob for easy setting
•Instant monitoring of operational status by LED indicators
UL, c-UL Listed
File No. E55996
Specifications
Rated Operating Voltage
Voltage Tolerance
Contact Rating
Contact Form
Repeat Error
Voltage Error
Temperature Error
Setting Error
Reset Time
Insulation Resistance
Dielectric Strength
Vibration Resistance
Shock Resistance
GE1A-B
Power
Consumption
GE1A-C
Electrical Life
Mechanical Life
Operating Temperature
Operating Humidity
24V AC/DC
100 to 120V AC
220 to 240V AC
AC: 85 to 110%
DC: 90 to 110%
240V AC/5A
24V DC/5A
DPDT or SPDT+ instantaneous SPDT
±0.2% ±10msec maximum
±0.5% ±10msec maximum
±3% maximum
±10% maximum
0.1 sec maximum
100MΩ minimum (500V DC megger)
Between power and output terminals: 1,500V AC, 1 minute Between contact circuits: 750V AC, 1 minute
Damage limits: Amplitude 0.75mm, 10 to 55 Hz Operating extremes: Amplitude 0.5mm, 10 to 55 Hz
Damage limits: 500m/s2 (Approx. 50G)
24V AC type: 1.6 VA
24V DC type: 1.0W
110V AC type: 3.8 VA
220V AC type: 7.7 VA
24V AC type: 2.0 VA
24V DC type: 0.8W
110V AC type: 3.5 VA
220V AC type: 8.0 VA
100,000 operations minimum (at full rated load)
10,000,000 operations minimum
–10 to +55°C (without freezing)
35 to 85% RH (without freezing)
844 |
www.idec.com |
Timers |
GE1A Series |
|
|
Part Numbering List
Mode of Operation |
Contact |
Output |
Rated Voltage |
Time Range |
Complete Part Number |
|
|
|
24V AC/DC |
|
GE1A-B10MAD24 |
|
|
|
|
|
|
|
|
|
110-120V AC |
0.1s to 10m |
GE1A-B10MA110 |
|
|
|
|
|
|
|
Delayed SPDT + |
|
220-240V AC |
|
GE1A-B10MA220 |
|
Instantaneous SPDT |
|
24V AC/DC |
|
GE1A-B10HAD24 |
|
|
|
|
|
|
|
|
|
110-120V AC |
0.1m to 10h |
GE1A-B10HA110 |
|
|
|
|
|
|
ON-Delay |
|
24V DC/120V AC, 5A |
220-240V AC |
|
GE1A-B10HA220 |
|
240V AC, 5A |
24V AC/DC |
|
GE1A-C10MAD24 |
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
110-120V AC |
0.1s to 10m |
GE1A-C10MA110 |
|
|
|
|
|
|
|
Delayed DPDT |
|
220-240V AC |
|
GE1A-C10MA220 |
|
|
|
|
|
|
|
|
24V AC/DC |
|
GE1A-C10HAD24 |
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
110-120V AC |
0.1m to 10h |
GE1A-C10HA110 |
|
|
|
|
|
|
|
|
|
220-240V AC |
|
GE1A-C10HA220 |
|
|
|
|
|
|
<![endif]>Lights Pilot & Switches
<![if ! IE]><![endif]>Lights Display
Timing Diagrams/Schematics
GE1A-B |
GE1A-C |
Delayed SPDT + Instantaneous SPDT |
Delayed DPDT |
|
|
|
|
m n |
|
|
|
m n |
Operation |
|
|
• |
o |
|
|
• |
o |
|
|
(-) k |
p (+) |
|
|
(-) k |
p (+) |
|
Mode Selection |
|
|
|
|
||||
|
|
|
|
j q |
|
|
|
j q |
|
|
|
|
POWER |
|
|
|
POWER |
|
Item |
Terminal Number |
Operation |
Item |
Terminal Number |
Operation |
||
ON-Delay 1 |
Set Time |
|
|
|
Set Time |
|
|
|
Power |
2 - 7 (8p) |
|
|
Power |
2 - 7 (8p) |
|
|
|
|
|
|
|
|
||||
MODE |
Delayed |
5 - 8 (8p) |
(NC) |
|
Delayed |
5 - 8 (8p) |
(NC) |
|
A |
Contact |
6 - 8 (8p) |
(NO) |
|
Contact |
6 - 8 (8p) |
(NO) |
|
|
|
|
|
|||||
|
1 - 4 |
(NC) |
|
|
POWER |
|
|
|
|
Instantaneous |
|
Indicator |
|
|
|||
|
|
|
|
|
|
|
||
|
Contact |
1 - 3 |
(NO) |
|
OUT |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|||
|
Indicator |
POWER |
|
|
|
|
|
|
|
OUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![endif]>Sockets & Relays
<![if ! IE]><![endif]>Timers
<![if ! IE]><![endif]>Blocks Terminal
<![endif]>Breakers Circuit
USA: 800-262-IDEC |
Canada: 888-317-IDEC |
845 |