New
Generation
PLC
FT1A Series - 24 I/O
Key Features
•Available in 100-240 VAC and 24 VDC power
•Available with/without embedded LCD
•10 Amp Relay contacts
•USB Mini-B Programming Port
•Embedded 4-pt analog inputs (0-10VDC, 10-bit, DC power)
•Integrated 4 x 100KHz high-speed counter
•Embedded Ethernet port
•Supports Modbus TCP and RTU
•Optional RS232C/RS485 adapter
General Specifications
Part Numbers |
FT1A-H24RA |
|
FT1A-B24RA |
FT1A-H24RC |
|
FT1A-B24RC |
|||
Appearance |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LCD Screen |
Yes |
|
N/A |
Yes |
|
N/A |
|||
|
|
|
|
|
|
|
|
|
|
Operating Temperature |
|
|
0 to +55°C (operating ambient temperature) |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
Storage Temperature |
|
|
–25 to +70°C (no freezing) |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
Rated Power Voltage |
|
24V DC |
100 to 240V AC |
||||||
|
|
|
|
|
|
|
|
||
Allowable Voltage Range |
20.4 to 28.8V DC (Including ripple voltage) |
85 to 264V AC |
|||||||
|
|
|
|
|
|
|
|
|
|
Rated Power Frequency |
|
– |
50/60Hz (47 to 63Hz) |
||||||
|
|
|
|
|
|
|
|
|
|
Maximum Power Consumption |
|
4.8W |
41VA |
||||||
|
|
|
|
|
|
|
|
||
Weight |
Approx. 310g |
Approx. 400g |
|||||||
|
|
|
|
|
|
|
|
|
|
Function Specifications |
|
|
|
|
|
|
|
|
|
Part Numbers |
|
|
|
|
FT1A-H24RA, B24RA |
|
|
|
FT1A-H24RC, B24RC |
|
|
|
|
|
|
|
|||
Program Capacity Note 1 |
|
|
|
|
|
47,400 bytes (11,850 steps) |
|||
|
Points |
|
|
|
|
16 |
|
||
|
|
|
|
|
|
|
|
||
|
Digital Input (Terminal No.) |
12 (I0 to I7, I10 to I13) |
|
|
|
16 (I0 to I7, I10 to I17) |
|||
|
|
|
|
|
|
|
|
||
|
Shared Analog Input (Terminal No.) |
4 (I14 to I17) |
|
|
|
– |
|||
Input |
|
|
|
|
|
|
|
|
|
Output Points |
|
|
|
|
8 |
|
|||
|
|
|
|
|
|
|
|||
|
10A Relay Output (Terminal No.) |
|
|
4 (Q0 to Q3) |
|||||
|
|
|
|
|
|
|
|||
|
2A Relay Output (Terminal No.) |
|
|
4 (Q4 to Q7) |
|||||
|
|
|
|
|
|
|
|||
|
Transistor Output (Terminal No.) |
|
|
– |
|||||
|
|
|
|
|
|
|
|||
User Program Storage |
|
|
|
|
Flash ROM (10,000 rewriting life) |
||||
|
|
|
|
|
|
|
|||
|
RAM |
|
|
|
Backup data: Internal relay, shift register, counter current value, |
||||
|
|
|
|
data register Note 2, clock data (year, month, and day) |
|||||
|
|
|
|
|
|||||
|
Backup Duration |
|
|
|
Approx. 30 days (typical) at 25°C after backup battery fully charge |
||||
|
|
|
|
|
|
|
|
|
|
Backup Function |
Battery |
|
|
|
|
|
Lithium |
||
|
Charging Time |
|
|
|
Approx. 15 hours for charging from 0% to 90% of full charge |
||||
|
|
|
|
|
|
|
|
|
|
|
Battery Life |
|
|
|
|
|
5 years |
||
|
|
|
|
|
|
|
|
|
|
|
Replaceability |
|
|
|
|
|
Not possible |
||
|
|
|
|
|
|
|
|||
Clock Function Note 3 |
|
|
|
|
Clock accuracy: ±30 sec/month (typical) at 25°C |
||||
Control System |
|
|
|
|
|
Stored program system |
|||
|
|
|
|
|
|
|
|
|
|
Specifications con’t on next page
Specifications con’t
Part Numbers |
|
FT1A-H24RA, B24RA |
|
FT1A-H24RC, B24RC |
Instruction Words |
Basic Instructions |
|
42 |
|
|
|
|
|
|
Advanced Instructions |
|
107 |
||
|
|
|||
|
|
|
|
|
Processing Time |
Basic Instruction |
|
0.95ms (1000 steps) |
|
|
|
|
|
|
END Processing |
|
640μs |
||
|
|
|||
|
|
|
|
|
Internal Relay |
|
|
1024 |
|
|
|
|
|
|
Shift Register |
|
|
128 |
|
|
|
|
|
|
Data Register |
|
|
2,000 |
|
|
|
|
|
|
Counter (adding, reversible) |
|
|
200 |
|
|
|
|
|
|
Timer (1-sec, 100ms,10ms, 1ms) |
|
|
200 |
|
|
|
|
|
|
Input Filter |
|
Without filter, 3 to 15ms (selectable in increments of 1ms) |
||
|
|
|
|
|
Catch Input/Interrupt Input |
Input Points |
|
6 |
|
|
|
|
|
|
Self-diagnostic Function |
|
Keep data, Power failure, Clock error, Watchdog timer, Timer/counter preset value change error, |
||
|
User program syntax, User program execution, System error, Memory cartridge transfer error |
|||
|
|
|||
|
|
|
|
|
|
Points |
Total 6 points |
|
– |
|
|
|
|
|
High-speed Counter |
Maximum Counter Frequency |
Single/two-phase selectable: 100kHz (2 points) , Single-phase: 100kHz (4 points) |
||
|
|
|
|
|
Counting Range |
|
0 to 4,294,967,295 (32 bit) |
||
|
|
|||
|
|
|
|
|
|
Operation Mode |
Rotary encoder mode and adding counter mode |
||
|
|
|
|
|
Pulse Output (Maximum |
Points |
|
– |
|
frequency: 100kHz) |
|
|||
|
|
|
|
|
|
|
|
|
|
Pulse Output (Maximum |
Points |
|
– |
|
frequency: 5kHz) |
|
|||
|
|
|
|
|
|
|
|
|
|
|
Points (Terminal No.) |
4 (I14 to I17) |
|
– |
|
|
|
|
|
Analog Voltage Input |
Input voltage Range |
|
0 to 10V DC |
|
|
|
|
|
|
|
Digital Resolution |
|
0 to 1000 |
|
|
|
|
|
|
|
Points |
|
1 |
|
|
|
|
|
|
USB Port |
USB Standard |
|
USB 2.0 |
|
|
|
|
|
|
|
Connector |
|
Mini-B type |
|
|
|
|
|
|
Expansion Communication Ports |
|
|
1 |
|
|
|
|
|
|
Ethernet Port |
|
|
1 |
|
|
|
|
|
|
Memory Cartridge Connectors |
|
|
1 |
|
|
|
|
|
|
SD Memory Card Slots |
|
|
– |
1.Step is equivalent to 4 bytes.
2.Among data registers D0 to D1999, only D0 to D999 are backed up.
3.Set the calendar/clock using the clock function in WindLDR.
Dimensions (mm)
With LCD |
|
|
Without LCD |
|
|
|
Dimension Table |
|
|
FT1A-H24*A/*C |
|
|
FT1A-B24*A/*C |
|
|
|
|
A |
B |
119 |
<![if ! IE]> <![endif]>11 |
A |
119 |
<![if ! IE]> <![endif]>11 |
|
A |
|
||
|
FT1A-H24RA |
60 |
56 |
||||||
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
FT1A-B24RA |
60 |
56 |
|
|
<![if ! IE]> <![endif]>110.3 |
|
<![if ! IE]> <![endif]>90 |
<![if ! IE]> <![endif]>110.3 |
|
FT1A-H24RC |
78 |
74 |
|
<![if ! IE]> <![endif]>90 |
|
|
FT1A-B24RC |
78 |
74 |
|||
|
<![if ! IE]> <![endif]>5 |
B |
<![if ! IE]> <![endif]>5 |
|
B |
|
|
|
|
|
|
|
|
|
|
|
Mounting Hole Layout
<![if ! IE]> <![endif]>(90) |
<![if ! IE]> <![endif]>100 |
.5 |
|
-ø4 |
|
2 |
(119) |
|
©2014 IDEC Corporation. All Rights Reserved. 03/14 PDF only