IC Realtime NVR 6000 Quick Start Manual

NVR 6000 Series Quick Start Guide
V2.0.0
i
Table of Contents
1 INSTALLATION AND CONNECTIONS ....................................................1
1.1 Check Unpacked NVR............................................................................................................1
1.2 Front Panel...............................................................................................................................1
1.3 Rear Panel................................................................................................................................2
1.4 Alarm Input and Output Connection .....................................................................................2
1.4.1 Alarm Input and Output Details.........................................................................................3
1.4.2 Alarm Input Port ..................................................................................................................3
1.4.3 Alarm Output Port...............................................................................................................4
2 OVERVIEW OF NAVIGATION AND CONTROLS ....................................5
2.1 Search & Playback ..................................................................................................................8
2.2 Network...................................................................................................................................12
2.2.1 Network Setting.................................................................................................................12
2.3 Remote Device ......................................................................................................................13
2.4 Manual Record.......................................................................................................................14
2.4.1 Manual record menu ........................................................................................................14
2.4.2 Basic operation .................................................................................................................14
2.4.3 Enable/disable record ......................................................................................................14
2.4.4 Enable all channel recording...........................................................................................14
2.4.5 Stop all channel recording...............................................................................................15
2.5 Shutdown................................................................................................................................16
ii
3 SYSTEM UPGRADE .............................................................................. 17
4 WEB OPERATION .................................................................................18
4.1 General Introduction..............................................................................................................18
4.1.1 Preparation ........................................................................................................................18
4.2 Login........................................................................................................................................18
APPENDIX H TOXIC OR HAZARDOUS MATERIALS OR ELEMENTS........21
iii
Welcome
Thank you for purchasing our NVR!
This quick start guide is designed to be a reference tool for the installation and operation
of your system.
Before installation and operation please read the following safeguards and warnings
carefully!
Please keep it for future reference!
iv
Important Safeguards and Warnings
1Electrical safety
All installation and operation here should conform to your local electrical safety codes.
We assume no liability or responsibility for all the fires or electrical shock caused by
improper handling or installation.
2Transportation security
Heavy stress, violent vibration or water splash are not allowed during transportation,
storage and installation.
3Installation
Keep upwards. Handle with care.
Do not apply power to the NVR before completing installation.
Do not place objects on the NVR.
4Qualified engineers needed
All the examination and repair work should be done by the qualified service engineers.
We are not liable for any problems caused by unauthorized modifications or attempted
repair.
5Environment
The NVR should be installed in a cool, dry place away from direct sunlight, inflammable,
explosive substances and etc.
This series product shall be transported, storage and used in the specified environments.
6. Lithium battery
Improper battery use may result in fire, explosion, or personal injury!
When replace the battery, please make sure you are using the same model!
7. Accessories
Be sure to use all the accessories recommended by manufacturer.
Before installation, please open the package and check all the components are included.
Contact your local retailer ASAP if something is broken in your package.
Name Quantity
Front panel key 2
HDD screws 68
Quick start guide 1
CD 1
1
1 Installation and Connections
Note: All the installation and operations here should conform to your local electric safety
rules.
1.1 Check Unpacked NVR
When you receive the NVR from the forwarding agent, please check whether there is any
visible damage. The protective materials used for the package of the NVR can protect most
accidental clashes during transportation. Then you can open the box to check the accessories.
Please check the items in accordance with the list. Finally you can remove the protective film of
the NVR.
1.2 Front Panel
The front panel is shown as below. See Figure 1-1.
Figure 1-1
Please refer to the following sheet for front panel button information.
SN Name Function
1 Power button Press it once to turn on the device.
Press it for a long time to turn off the device. (Usually we do not
recommend).
2 System HDD
Indication light
The blue light flashes when system is reading or writing the system
HDD.
In the system HDD, there are device important configuration file,
factory default configuration file, and device initial boot up data.
3 Alarm indication
light
The alarm indication light becomes on once an alarm occurred. The
alarm includes hardware alarm, network abnormal events, or system
receives the alarm signal and etc.
4 Network
indication light
The network indication light is blue and it flashes when you connect
the device to the network.
5 USB port /
6 Front panel lock /
After you remove the front panel, you can see there are 16 HDDs. From the left to the right and
2
from the top to the bottom, it ranges from 1~4, 5~8, 6~12, 13~16.
You can see there are two indication lights on the HDD bracket.
z The power indication light is at the top. The light is yellow after you connected the device to
the power.
z The read-write indication light is at the bottom. The blue light flashes when system is
reading or writing the data.
1.3 Rear Panel
The rear panel is shown as below. See Figure 1-2.
Figure 1-2
Please refer to the following sheet for detailed information.
SN Function SN Function
1 Power socket 6 Video VGA output
2 Audio Input 7 eSATA port
3 Audio output 8 USB port
4 Bidirectional talk input 9 HDMI port
5 Network port 10 Alarm input, alarm output, RS485 port.
1.4 Alarm Input and Output Connection
Please refer to the following sheet for alarm input and output connection.
There are two alarm input types for you to select: normal open (NO) and normal close (NC).
1. Alarm input
a. Please make sure alarm input mode is grounding alarm input.
b. Grounding signal is needed for alarm input.
c. Alarm input needs the low level voltage signal.
d. Alarm input mode can be either NC (normal Open) or NO (Normal Close)
e. When you are connecting two NVRs or you are connecting one NVR and one other device,
please use a relay to separate them.
2. Alarm output
The alarm output port should not be connected to high power load directly (It shall be less than
1A) to avoid high current which may result in relay damage. Please use the co contactor to
3
realize the connection between the alarm output port and the load.
3. Please make sure the front-end device has soundly earthed.
Improper grounding may result in chip damage.
1.4.1 Alarm Input and Output Details
You can refer to the following sheet X for alarm input and output information. See Figure 1-3.
Figure 1-3
Please refer to the following sheet and Figure 1-3 for detailed information.
123456 7891011 12,13,1415,16
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
1-ON C2- ON C 3- ON C4- ON C 5- ON C6- ON C 7 - ON C8- ON
Eight groups of normal open activation output (on/off button)
G GND cable.
485 A/B The A/B cable to control the RS485 devices. It is to connect to
control decoder such as the recorder.
Tx and Rx RS232 port. Tx is the data output cable and the Rx is the data input
cable.
1.4.2 Alarm Input Port
Please refer to the following sheet for more information.
z Grounding alarm inputs. Normal open or Normal close type)
z Please parallel connect COM end and GND end of the alarm detector (Provide external
power to the alarm detector).
z Please parallel connect the Ground of the NVR and the ground of the alarm detector.
z Please connect the NC port of the alarm sensor to the NVR alarm input(ALARM)
z Use the same ground with that of NVR if you use external power to the alarm device.
Loading...
+ 18 hidden pages