ICOM UC-FR5300 Instruction Manual

Page 1
INSTRUCTIONS
TRUNKING/NETWORK CONTROLLER
UC-FR5300
Thank you for choosing this Icom product. READ ALL INSTRUCTIONS carefully and completely before using this product.
EXPLICIT DEFINITIONS
WORD DEFINITION
R WARNING!
CAUTION Equipment damage may occur.
NOTE
Icom is not responsible for the destruction, damage to, or performance of any Icom or non-Icom equipment, if the malfunction is because of:
• Force majeure, including, but not limited to, fi res, earthquakes, storms, fl oods, lightning, other natural
disasters, disturbances, riots, war, or radioactive contamination.
• The use of Icom transceivers with any equipment that is not manufactured or approved by Icom.
Icom and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United Kingdom, Germany, France, Spain, Russia, Australia, New Zealand, and/or other countries.
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
Jul. 2022
Personal injury, fi re hazard or electric
shock may occur.
If disregarded, inconvenience only. No
risk of personal injury, fi re or electric
shock.
Printed in Japan
© 2020–2022 Icom Inc.
PRECAUTIONS
R WARNING! Turn OFF the repeater before installing the
controller. Otherwise, this could cause a fi re or damage
the repeater.
CAUTION: NEVER expose the repeater or controller to rain, snow or any liquids.
CAUTION: NEVER let metal, wire or other objects touch any parts on the controller.
CAUTION: NEVER install the controller into a non-
specifi ed repeater.
BE CAREFUL! When you install the controller, wear gloves to avoid cutting your hand on the sharp edges of the repeater.
D CF card caution
R WARNING! NEVER insert the CF card into the UC-
FR5300 when the repeater’s power is ON. Otherwise a
fi re, electric shock may occur, or the data on the CF card
may become corrupted.
CAUTION: DO NOT insert the CF card into the UC­FR5300 if dust or dirt is on the connector. This may cause the CF card, and the UC-FR5300, to malfunction.
CAUTION: DO NOT directly touch the connector part of the CF card. It may cause a breakdown of the internal circuit by static electricity.
CAUTION: DO NOT turn OFF the repeater while the data is being transferred. Otherwise, the data on the CF card may become corrupted.
CAUTION: DO NOT use the CF card in a controller other than the UC-FR5300. Inserting the CF card into other equipment may corrupt the card’s data.
CAUTION: DO NOT keep the CF card in areas with extremely high temperatures, high humidity, or in direct sunlight.
BE CAREFUL! DO NOT submerge the CF card in water, or get it wet.
BE CAREFUL! DO NOT bend the CF card.
BE CAREFUL! DO NOT drop or strike the CF card
against another object.
CONFIGURATIONS
The controller enables the repeater to be used for the
following modes, depending on the confi gurations.
(As of July 2022)
UC-FR5300 #11
CF card
Single
Trunking
Site
Conventional
Multi
Site
Trunking
Simulcast
*1 Either the optional CF-FR5000MC, CF-FR5000MT or
CF-FR5300SC is required.
2
*
The optional CF-FR5000MT is required.
3
*
The optional CF-FR5300SC is required.
UC-FR5300 #12
CF­FR5000MC
1
*
2
–*
3
*
UC-FR5300 #13
CF­FR5000MT
2
–*
3
*
3
*
UC-FR5300 #14
CF­FR5300SC
2
–*
FCC INFORMATION
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit
diff erent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
DISPOSAL
The crossed-out wheeled-bin symbol on your product, literature, or packaging reminds you that in the European Union, all electrical and electronic products, batteries, and accumulators (rechargeable batteries) must be taken to designated collection locations at
of these products as unsorted municipal waste. Dispose of them according to the laws in your area.
the end of their working life. Do not dispose
ABOUT CE
Versions of the UC-FR5300 which have the “CE” symbol on the product, comply with the essential requirements of the 2014/30/EU directive for Electromagnetic Compatibility and the 2001/95/EU directive for General Product Safety.
Below statement is for UKCA purpose only
United Kingdom Authorised Importer: Icom (UK) Ltd. Address: Blacksole House, Altira Park, Herne Bay,
Kent, CT6 6GZ, U.K.
SUPPLIED ACCESSORIES
Rear panel
Flat cable Screws (3 × 8 mm)
Screws (3 × 12 mm)
CF card*
GPS antenna connector
*Supplied or not depends on the controller’s version.
Rear panel holder
Dust protectors
Connector caps
Lock washer
OPTION
CF-FR5000MC 
Same as that supplied with UC-FR5300 #12.
CF-FR5000MT 
Same as that supplied with UC-FR5300 #13.
CF-FR5300SC 
Same as that supplied with UC-FR5300 #14.
UX-241 

 The coaxial cable (purchase separately) is required to
connect the AH-38.
Nut
DISASSEMBLING THE UNITS
1. Unscrew the seven screws on the top, and the two screws on both sides of the repeater, then slide the top cover off in the direction of the arrow.
Top cover
P
0
P
1
P
2
P
3
P
4
Repeater
2. Disconnect the control cable from the channel module. Unscrew the seven screws that affix the channel module to the repeater chassis, and then remove it.
Control cable
P
0
P
1
P
2
P
3
P
4
Front panel*
*
The front panel is removed in this illustration so the details are easier to see. However, you can remove the channel module without removing the front panel of the repeater.
3. Unscrew the eight screws from the top, the nine screws from the bottom, and the three screws from rear of the channel module. Then remove each cover.
Channel module
Repeater
INSERTING AND REMOVING THE CF CARD
D Inserting
NOTE: Be sure to insert the CF card with the serial label
(Example: “CF-FR5300SC” label) facing up.
Slowly insert the CF card into the CF card slot of the UC-FR5300.
• If the CF card seems to jam, or is too tight, carefully remove it. Ensure that the card is properly oriented and that there are no obstructions in the sides of the card insertion slots, then reinsert the card.
CF card slot
UC-FR5300
Serial label
CF card
D Removing
Hold the edge of the CF card, and slowly pull it out.
NOTE: When no CF card is inserted, the UC-FR5300 cannot be used for Multi Site Conventional mode, Multi Site Trunking mode, and Simulcast mode operation.
INSTALLING
D Installing the UC-FR5300
Install the controller into the channel module using the six supplied 3 × 8 mm screws.
NOTE: BE SURE to match the holes in the controller to the projections on the channel module’s chassis.
Controller
Holes
Projections
Channel module
D 
NOTE: BE SURE to insert the fl at cable with the metal
strips facing the edge of the Printed Circuit Board (PCB), and not the opposite way.
1. Turn the channel module upside down.
Insert one end of the fl at cable into J8 on the PCB of
the channel module. Then, carefully pass the fl at cable
through the opening of the channel module’s chassis to the top side.
Bottom
Front
Top
2. Turn over the channel module.
Carefully pull out the other end of the fl at cable from
the opening, and then insert it into J1 on the controller.
Top
Front
Bottom
Flat cable
Rear
J8
Opening
J1
Flat cable
Rear
Channel module
Page 2
q
w
BUS-1BUS-2LAN
D Attaching the rear panel
GPS ANT
1. Insert the supplied rear panel into the rear panel holder.
2. Attach the rear panel and holder set to the channel module using the three supplied 3 × 12 mm screws.
Channel module
Rear panel
Rear panel holder
TIP: If you have installed an optional UR-FR5300/UR-FR6300 series channel extension module, an additional controller in it enables you to control each channel module from a PC in the Conventional/Trunking/Simulcast operation mode.
D Installing the GPS antenna connector
GPS ANT
ASSEMBLING THE UNIT
1. Reattach the top and bottom covers of the channel module, and then tighten all the screws.
Channel module
2. Reinstall the channel module and the screws to their original positions, and then connect the control cable of the repeater’s front panel to the channel module.
Channel module
CONNECTION
NOTE:
• CAT-5 straight cables are required for connection. (User supplied)
BE SURE to cover each connected cable with a supplied dust protector. Even if the cable has its own cover, replace it with the supplied dust protector.
KEEP the supplied connector caps attached when the connectors are not in use, to avoid getting bad contacts from dust or moisture.
Each controller has a LAN connector and two BUS connectors. 1 [LAN] connector
For an Ethernet connection. Connect the controller to
an Ethernet (LAN) port of a PC. In the Simulcast mode and Trunking mode, the controller at one end of the chain must be connected. You can control the controller and all others in the chain from the PC.
2
[BUS] connectors (BUS-1, BUS-2) For data communication between the controllers in the Simulcast mode BUS-2 can be used. They enable the controllers to be “daisy-chained” together, and form a network that allows simulcast, trunking and other data to pass among them.
* PPS signal can be shared with other UC-FR5300 through
the [BUS] connectors.
NOTE: BE SURE to connect a LAN cable of 1 m (3.3 feet) or less.
 The illustration below describes one example of a
connection for the Trunking mode.
* and Trunking mode, either BUS-1 or
PC
1. Insert the supplied GPS antenna connector through the GNSS hole and Lock washer.
2. Tighten the supplied nut.
3. Connect the coaxial cable to the GPS antenna connector near the CF card slot.
Lock washer
Nut
Control cable
P
0
P
1
P
2
P
3
P
4
Repeater
Front panel
3. Reattach the top cover of the repeater, and then tighten the seven screws for the top and the two screws on both sides of the repeater.
Top cover
P
0
P
1
P
2
P
3
P
4
Repeater
Repeater
Channel extension module
Up to 30 channel modules with controllers can be daisy-chained.
Connector cap
Dust protector
THE SETTING SCREEN OF THE UC-FR5300
NOTE:
• Microsoft Edge (Chromium based) is a recommended web browser.
• Enable JavaScript web browser to correctly display the setting screen.
• The Setting screen may not be correctly displayed, depending on the browser.
D Accessing the setting screen
NOTE: You must wait to launch the web browser until
the controller system software startup is completed. It typically takes 2 ~ 3 minutes for the controller to startup the application.
1. Connect a CAT-5 straight cable between the controller’s [LAN] connector and a PC, and then turn ON the repeater.
2. Before accessing the Setting screen, change the IP address of the PC to 192.168.0.XXX* (A subnet mask should be 255.255.255.0) on the Network & Internet setting screen.
*
Replace XXX with any number between 1 and 254 (except 11).
 Refer to the Operating System’s manual for details.
3. Open your web browser, enter “http://192.168.0.11” (default IP address of the UC-FR5300) into the address bar, and then push [Enter].
• The Login Authentication screen is displayed.  Ask your system administrator for details.
4. Enter “cbadmin” (default user name) and “ucfr5300” (default password) in their respective input field in the Login Authentication screen, and then click <Sign in>.
• The Opening screen is displayed.
TIP: You can change the user name and password in the Setting screen. Refer to the Help window of the Setting screen for details.
®
and set to accept cookies on your
Enter
D Opening the help window
The Setting screen of the controller has a help window to describe functions and settings. If you don’t understand the meaning of an item, or how to
confi gure the controller, click a question mark icon on the
screen to open the help window.
Click to open the help window for “General Settings,” for example.
D Initialization
You can reset all set contents, including the network settings of the controller, to the factory default from the PC.
1. Connect the controller to the PC, and then turn ON the repeater.
2. Open your web browser, enter the initialize address into the address bar, and then push [Enter].
The initialize screen is displayed. Initialize address: http://(IP address):8080/init.html  When the IP address of the controller is 192.168.0.11*,
enter “http://192.168.0.11:8080/init.html” as the initialize
address.
* The IP address is an example only. Check the IP
address of the controller.
3. After checking the box “Yes, I agree,” click <RESET>
to initialize the settings.
TIP: If you use the UC-FR5300, you can select whether or not to reset the Network settings as well as other settings. Refer to the help window for details.
Enter
Click
Enter
Check
Click
This screen may diff er slightly, depending on the
Operating System or web browser version.
Loading...