FCC information
This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct
the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit diff erent
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
Disposal
The crossed-out wheeled-bin symbol
on your product, literature, or packaging
reminds you that in the European
Union, all electrical and electronic
products, batteries, and accumulators
(rechargeable batteries) must be taken
to designated collection locations at the end of their
working life. Do not dispose of these products as
unsorted municipal waste. Dispose of them according
to the laws in your area.
About CE
Versions of this model which have the
“CE” symbol on the product, comply
with the essential requirements of the
2014/30/EU directive for Electromagnetic
Compatibility and the 2001/95/EC directive for
General Product Safety.
INSTALLATION GUIDE
dPMR SYSTEM MANAGER
RS-MGR2
• See the instruction manuals of the PC or external device for their operation details.
• The displayed screens, dialogs, indications may diff er slightly, depending on your system settings, type of OS and its service
pack level.
• To operate the software, refer to the RS-MGR2 Instruction manual.
• To read the instruction manual, Adobe Acrobat Reader is required.
If you have not installed Reader, download it from Adobe Systems Incorporated’s web site.
About the Instruction manual (PDF)
When you start the software, select “Help” on the main menu screen, and then select “Manual” to display the
RS-MGR2 instruction manual for assistance with the functions or settings.
Thank you for choosing this Icom product.
READ ALL INSTRUCTIONS carefully and completely
before using this product.
Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United Kingdom, Germany, France,
Spain, Russia, Australia, New Zealand, and/or other countries.
Microsoft and Windows are trademarks of the Microsoft group of companies.
Adobe, Acrobat, and Reader are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries.
All other products or brands are registered trademarks or trademarks of their respective holders.
The following system is required to use the RS-MGR2.
D PC
• CPU: Intel Core2 Duo Processor
E6600/2.40GHz, equivalent or faster
• System memory: 2 GB or more
• Monitor: 1280 x 1024 or better resolution
• Sound card: For sounding alarms
• Speaker: For sounding alarms
• LAN: 100 Mbps or faster
(Fixed IP address necessary)
NOTE: DO NOT install more than 2 LAN cards into the PC.
D Operating System (OS)
• Microsoft Windows Server 2012 R2
• Microsoft Windows Server 2012
• Microsoft Windows 10
• Microsoft Windows 8.1 (Except for Windows RT)
RS-MGR2 can be used with both 32 and 64 bit versions of the
operating systems listed above.
Browser:
• Internet Explorer 11.x* *Any number
Other:
• USB port A USB 1.1 or 2.0 port
• Hard disk: At least 500 GB of free space.
CS-FC5000:
• You need another PC that has the CS-FC5000 (later than
version 2.20) installed.
• The PC with the CS-FC5000 and the PC with the
RS-MGR2 need to be connected through the network.
Apache is automatically added to the fi rewall’s exception
programs, when the RS-MGR2 is installed to your PC.
NOTE: The RS-MGR2 communication ports are UDP 161,
UDP 514, and TCP 1468 as defaults.
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
Feb. 2022
- 4 -
- 1 -
A7376W-1EX-1 Printed in Japan
© 2017–2022 Icom Inc.

• The included USB fl ash drive does not have the Write Protection, so formatting it will erase all data. Also, USB fl ash drives
have a certain lifetime and you may not be able to read or write data after a long period of use. We recommend making a
backup fi le of the data on the USB fl ash drive onto another device.
• Icom is not responsible for any lost profi ts, or data, or consequential, special, indirect, or incidental damages.
When installing the software, confi rm Windows has completed its startup, and then sign in as the administrator.
These instructions are based on using Microsoft Windows 10.
1. Confirm no other applications are running.
2. Insert the USB flash drive into the PC.
3. Double-click “setup_x64.exe” or “setup_x86.exe”
7. “Destination Folder” is displayed. Click <Next >>.
• If desired, click <Change...> to select another
destination folder before clicking <Next >>.
in the USB flash drive.
• setup_x64.exe: Installer for the 64 bit version OS.
• setup_x86.exe: Installer for the 32 bit version OS.
If “User Account Control” is displayed, click <Yes>.
4. “Welcome to the InstallShield Wizard for
RS-MGR2” is displayed. Click <Next>>.
Confi rm
5. “License Agreement” is displayed.
After reading the privacy policy, select “I accept the
terms in the license agreement” and click <Next >>.
Before using the RS-MGR2, follow the instructions below to enable the Syslog function for the CS-FC5000.
NOTE: The CS-FC5000’s fi rmware must be later than revision 2.20.
See the CS-FC5000’s Confi guration Manual for details on updating the fi rmware.
1. Open the Configuration > Region screen, and
then click [Monitoring].
Click
2. Enter the “Syslog Severity IP Address” of the PC
that has the RS-MGR2 installed.
3. Select “UDP” for the “Syslog Protocol” setting.
4. Select “v2c” for the SNMP Mode setting.
5. Click [Apply] to save the settings.
6. Click [Configuration Update] to update the
configured settings on the RS-MGR2.
NOTE: Be sure that the PC with the CS-FC5000
and the PC with the RS-MGR2 are connected
through the network.
Enter
Select
Select
Select
Click
6. “Port Setting” is displayed.
Confirm the Apache port number, and then click
<Next>>.
• If desired, enter a diff erent Apache port number before
clicking <Next >>.
Click
Click
8. “Ready to Install the Program” is displayed.
Click <Install> to start installing.
9. After the installation has completed, “InstallShield
Wizard Completed” is displayed. Click <Finish>.
NOTE: You can uninstall the software using the
“Apps & features” in the “Settings” menu.
To get started, click on Start > Settings > Apps >
Apps & features.
NOTE: Be sure that you sign in as the administrator.
1. Start Internet Explorer.
2. Enter the URL and go to the page.
URL: https://(Static IP address of the PC that has
the RS-MGR2 installed, and the apache
port number)/
Example: https://xxx.xxx.xxx.xxx:53959/
• Apache port number is set to 53959 as default.
• “There’s a problem with this website’s security
certifi cate” is displayed.
3. Click “Continue to this website (not
recommended).”
4. The Log-in screen is displayed.
Enter the user name and password, and then click
on [Login] to start the RS-MGR2.
User name: admin
Password: admin (default)
Enter
Click
NOTE: Change the password on the
Client Management screen.
TIP: You can operate the RS-MGR2 using
Internet Explorer on another PC that is on the
same network.
- 2 - - 3 -