Icom PS-300 Instructions Manual

INSTRUCTIONS
DC POWER SUPPLY
PS-300
PRECAUTIONS
RWARNING! NEVER apply AC voltage that exceeds the
specified voltage to the PS-300’s AC power cable. Exces­sive voltage could cause a fire or ruin the power supply.
RWARNING! Immediately turn the power supply OFF
and remove the AC power cable if it emits an abnormal odor, sound or smoke. Contact your Icom dealer or dis­tributor for advice.
RCAUTION! NEVER let metal, wire or other objects
touch any internal parts through the slits of the case or terminals on the rear panel of the power supply. This may result in an electric shock.
RCAUTION! NEVER connect the power supply to a DC power source using reverse polarity. This will damage the power supply.
RCAUTION! NEVER open the top cover. There are no
user adjustment parts. Opening the case may expose you to electric shock and incorrect reassembly may cause a fire hazard.
Thank you for purchasing the PS-300 dc power supply.
Please read these instructions thoroughly before operat­ing the PS-300.
RCAUTION! NEVER put the power supply in any unsta-
ble place (such as on a slanted surface or vibrating area). This may cause injury to you and/or damage to the power supply.
RCAUTION! The socket-outlet must be near the DC
power supply and must be easily accessible.
RUSE INDOORS ONLY! NEVER expose the power sup-
ply to rain, snow or any liquids.
DO NOT use or place the power supply in areas with tem- peratures below 0°C or above +40°C.
• DO NOT use chemical agents such as benzine or alcohol when cleaning, as they can damage the power supply’s surfaces.
DO NOT place the power supply against walls or put any- thing behind the power supply. This will obstruct heat dis­sipation.
KEEP the power supply out of the reach of children.
USE an AC outlet that can supply more than 840 VA ca- pacity. AVOID the use of a multi-plug adaptor.
SPECIFICATIONS
• Input voltage : 230 V AC (50 Hz~) [EUR] 240 V AC (50 Hz~) [AUS]
• Output voltage : 1–15 V DC
• Output current (at 13.8 V) : 25 A Continuous, 30 A Maximum 50% duty cycle (1 min. ON/1 min. OFF)
• Ripple & Noise (at 13.8 V) : Less than 20 mV p-p
• Load Regulation (0% to 100%) : Less than 50 mV
• Dimensions (projections not included) : 203(W)×110(H)×280(D) mm
• Weight (approx.) : 9 kg
• Usable temperature range : 0˚C to +40˚C 25 A (15 V) continuous operation at +40˚C is for 4 hours 22 A (15 V) continuous operation at +40˚C is for 8 hours 25 A (15 V) continuous operation at +25˚C is for 8 hours
Versions of the PS-300 which display the “CE” symbol on the serial number comply of the Low Voltage Directive (2006/95/EC) and the EMC Directive (2004/108/EC).
This compliance is based on conformity with the following harmonized standards EN61558-1:1997, EN61558­1+A1:1998, EN61558-1+A11:2003, EN61558-2-6:1997, EN55014-1:2006, EN61000-3-2:2006, EN61000-3-3:1995, EN61000-3-3+A1:2001, EN61000-3-3+A2:2005, EN55014-2:1997, EN55014-2+A1:2001.
with the essential requirements
Icom, Icom Inc. and the logo are registered trademarks of Icom Incorporated (Japan) in the United States, the United Kingdom, Germany, France, Spain, Russia and/or other countries. All other products or brands are registered trademarks or trademarks of their respective holders.
PANEL DESCRIPTION
V
I
+ – +
+
O
A
w
q
!0 !1i
e
r t
uy o
0
10
20
30
21 4 6 8 10 12 14
Output Voltage [V]
Output Current [A]
15
FRONT PANEL
q OVERLOAD INDICATOR Lights red when
load or the + and _ lines are shorted
w AMPERE METER Shows the driving current. e VOLTMETER Shows the output voltage. r POWER INDICATOR Power indicator lights green when the PS-300 is turned
ON.
t POWER SWITCH Turns the PS-300 power ON or OFF.
the PS-300 is under the condition of over-
.
y DC OUTPUTS (Max. 3 A) Connect DC power cables. u DC OUTPUTS (Max. 30 A) Connect DC power cables. i CONTROLLER Adjusts the DC output voltage within 1–15 V.
REAR PANEL
o COOLING FAN !0 FUSE HOLDER
5 A fuse (F5AL250V) is installed. !1 AC POWER CABLE Connects to the AC outlet.
CONNECTION AND OPERATION
q Connect the AC power cable of the PS-300 to an AC out-
let.
w Turn the PS-300 ON, then adjust the suitable output volt-
age.
• “ I ” : ON (Power indicator lights green)
• “O” : OFF (Power indicator goes off)
e Turn the PS-300 OFF, and make sure the equipment's
power is also OFF.
r Connect the DC power cable to the PS-300 and the
equipment's DC power input.
t Turn the PS-300 ON. y Turn the equipment ON. u To turn OFF the system, turn the equipment power OFF,
then the PS-300 in sequence.
CURRENT CAPACITY
Current capacities of the PS-300 depend on their output voltage as per the graph at right. (The graph shows typical values for reference.)
OVERLOAD AND SHORT CIRCUIT PROTECTOR
The PS-300 has overload and short circuit protection circuits. When the PS-300 is under the condition of overload or the + and _ lines are shorted, the PS-300 limits the output current and the overload indicator lights red. In such a case, turn OFF the PS-300, remove the source of the problem, wait several seconds, then turn it ON again.