2
The SC3801 is a programmable, auto changeover, two stage heat, two stage cool thermostat. It functions
with air conditioning, heat pumps, gas, oil, or electric heat.
The thermostat activates a heating appliance when the room temperature is below the set heat
temperature (by the differential temperature). The red status indicator may come on with first or second
stage, depending on configuration. When the room temperature drops further, the second stage (auxiliary)
heat is activated. The heating is staged off when the room temperature increases. With heat pumps,
the thermostat will not let the compressor come on for four minutes after it turns off. This protects your
compressor. Emergency heat mode can be used to bypass heat pump operation, making auxiliary heat first
stage.
When the room temperature is greater than the set cool temperature (by the differential temperature), the
first stage cooling device is activated. The green status indicator may come on with first or second stage,
depending on configuration. If the room temperature increases, the second stage cooling device will be
activated. The cooling is staged off when the room temperature decreases. The thermostat will not let the
compressor come on for four minutes after it turns off. This protects your compressor.
The SC3801 has the following operating modes: OFF, Heat, Emergency Heat, Cool, Cool and Heat, and
Program mode. In OFF mode, the thermostat will not turn on heating or cooling devices. The indoor fan can
be turned on in all operating modes using the fan switch. In the Heat mode, the thermostat controls the
heating system. Emergency Heat mode can be utilized if a heat pump malfunction occurs. In the Cool mode,
the thermostat controls the cooling system. In the Cool and Heat mode, the thermostat controls both the
cooling and heating systems. In Program mode, the thermostat will automatically be controlled by the set
program. Program mode can function with Heat mode, Cool mode, Cool and Heat mode or OFF mode (for
Programmable fan option only). The clock display alternates with the set temperature display for Cool and
Heat mode.
The program schedule can be overridden by changing the set temperature ( or ). This puts the SC3801
thermostat into a 2-hour temporary hold. After 2 hours, it will automatically return to the program schedule.
The SC3801 also has a button lockout feature. This enables the thermostat to be set to the proper mode
and temperature and locked so it cannot be tampered with.
Mode of Operation