ICM Controls SC 1800 Installation, Operation & Application Manual

Manual Changeover Non-Programmable
Hardwired
SC 1800
Non-Programmable Electronic Thermostat
Installation, Operation & Application Guide
For more information on our complete range of American-made products – plus wiring diagrams, troubleshooting tips and more, visit us at www.icmcontrols.com
• Controls Single Stage Heating Systems
• Millivolt and Hydronic (water or steam) System Compatible
• Compatible with Gas and Electric Systems
• Mercury-Free, Environmentally Safe
Table of Contents
Parts Diagram ......................................................................................................................1
Specifications .......................................................................................................................2
Important Safety Information ..............................................................................................2
Package Contents/Tools Required ........................................................................................2
General Description ..............................................................................................................3
To Remove Existing Thermostat .........................................................................................3
Replacing Wiring Labels .......................................................................................................4
To Install Thermostat ...........................................................................................................4
Installing and Changing Batteries .........................................................................................5
Wiring Diagrams ...................................................................................................................6
Heating Only .....................................................................................................................6
Zone Valve/Damper Motor System ...................................................................................7
Setting the Setpoint Temperature .......................................................................................8
Setting the Temperature Differential ...................................................................................8
Changing Fahrenheit to Celsius ............................................................................................8
Starting the Thermostat ......................................................................................................8
A Quick Test .........................................................................................................................9
Troubleshooting ...................................................................................................................9
1
Room Temperature Setpoint
Room Temperature
Low Battery Signal
Temperature Differential Setting
SET ROOM LO BAT DIFF
Celsius/ Fahrenheit Jumper
Heat Switch
Battery Compartment
Fan Switch
Electric/Gas Switch
Parts Diagram
2
Package Contents/Tools Required
Package includes: SimpleComfort® 1800 thermostat on base, thermostat cover, wiring labels, screws
and wall anchors, Installation, Operation and Application Guide.
Tools required for installation: Drill with 3/16” bit, hammer, screwdriver.
Electrical rating: • Millivolt to 30 VAC/VDC
• DC Power: 3.0 VDC (2 “AA” alkaline batteries included)
• 1 amp maximum per terminal
• 2 amp maximum total load
Temperature control range: 45°F to 90°F (7°C to 32°C) Accuracy: ± 1°F (± 0.5°C) Differential Rage: 1°F to 3°F (0.5°C to 1.5°C) System configurations: 1-stage heat, gas, oil, electric Terminations: R, W, G
Important Safety Information
WARNING!
:
Always turn off power at the main power supply before installing, cleaning, or
removing thermostat.
• This thermostat is for 24 VAC applications only; do not use on voltages over 30 VAC
• Do not short across terminals of gas valve or system control to test operation; this will damage your
thermostat and void your warranty
• All wiring must conform to local and national electrical and building codes
• Use this thermostat only as described in this manual