Ice-O-Matic CIM0430HW, CIM0436HW, CIM0526HA, CIM0520HW, CIM2047HW Installation Manual

...
ELEVATION SERIES CUBE ICE MAKER
CIM 300 lb through 2000 lb Cubers
Ice-O-Matic 11100 East 45th Avenue Denver, Colorado 80239 1-800-423-3367 9081484-01 REV. J
01/2019
ELEVATION SERIES INTRODUCTION
Energy Efficiency
Ice-O-Matic has partnered with ENERGY STAR since 2004 to ensure our customers receive the most efficient ice machines for your investment dollar. Ice-O-Matic is committed to the continuous improvement in both energy efficiency and productivity thereby delivering the best value in energy efficient ice machines money can buy.
For a detailed list of ENERGY STAR qualified Ice-O-Matic ice machines, go to:
http://www.iceomatic.com/Products/Sales-Literature/
Freight Claims
Inspect Promptly
This merchandise has been carefully inspected and packed in accordance with the carrier’s packing specifications. Responsibility for safe delivery has been assumed by the carrier. If loss or damage occurs, you as the consignee must file a claim with the carrier and hold the container for carrier’s inspection.
Visible Loss or Damage
Any external evidence of loss or damage must be fully described and noted on your freight bill or express receipt and signed by the carrier’s agent. The claim should be filed on a form available from the carrier.
Concealed Loss or Damage
If loss or damage does not appear until merchandise has been unpacked, make a written request for inspection by the carrier within 5 days of the delivery date, then file a claim on a form from the carrier.
FILE CLAIMS WITHOUT DELAY
DO NOT RETURN DAMAGED GOODS
TO ICE-O-MATIC
How to use this Manual
Ice-O-Matic provides this manual as an aid to the service technician in installation and maintenance of the CIM Series cube ice machines. Do not attempt to perform installation, start-up or maintenance unless you have read and fully understand this manual.
Ice-O-Matic ice-makers and dispensers are not approved for outdoor installation.
Air and water cooled ice machines are hermetically sealed and contain fluorinated greenhouse gas
R404A (GWP 3922)
For a Service Provider, please reference our “Find a Service Technician” tab at www.iceomatic.com
Keep this manual for future reference
The CIM Series Service Parts Manuals are available separately.
WARNING
Always disconnect electrical power and shut off water supply whenever maintenance or repairs are
performed on the ice machine and related equipment
CAUTION
Always wear protective eyewear whenever maintenance or repairs are performed on the ice machine
and related equipment
Ice-O-Matic Warranty
Every Ice-O-Matic ice maker is backed by a warranty that provides both parts and labor coverage. To view
the warranty details, register products, or check your warranty status visit the “Warranty and Water Filter
Registration” page on www.iceomatic.com
1
ELEVATION SERIES INSTALLATION GUIDELINES
Installation Guidelines
For proper operation of the ice machine, the following installation guidelines must be followed by a qualified refrigeration technician. Failure to do so may result in loss of production capacity, premature part failures, and may void all warranties.
Reference the installation parameters prior to installing the machine. Ice-O-Matic assumes no responsibility for improperly installed equipment. Excessive time required for service or time for units requiring removal for service of inaccessible equipment will be the sole responsibility of the equipment owner.
All water supply lines must be installed per local codes. Use 3/8 inch O.D. minimum on air cooled machines. On water cooled machines 3/8 inch O.D. minimum tubing must be run to the condenser. The water supply for the machine can “T” off from the condenser line using 3/8 inch O.D. minimum tubing. Make 2 coils of extra tubing so that the machine can be pulled away from the wall if service is needed.
Water Filtration/Treatment
A water filter system should be installed with the ice machine. Refer to Ice-O-Matic water filter specification sheet.
This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. Children shall be supervised and are not to play with the appliance.
Ambient Operating Temperature
Minimum operating temperature: 50°F (10°C) Maximum operating temperature: 100°F (38°C) (60 Hz.), 110°F (43°C) (50 Hz.).
Note: Ice-O-Matic ice-makers and dispensers are not
approved for outdoor installation
Incoming Water Supply
WARNING: Connect to unheated potable water
supply only
(see Electrical and Plumbing diagrams for line sizing)
Minimum incoming water temperature:
40°F (4.5°C)
Maximum incoming water temperature:
100°F (38°C)
Minimum incoming water pressure:
20 psi (1.4 bar, 0.138MPa)
Maximum incoming water pressure:
80 psi (5.5 bar, 0.552MPa)
Note: if water pressure exceeds 80 psi (5.5 bar), a water
pressure regulator must be installed
Reverse Osmosis (RO) water can be very acidic and can attack the evaporator and other metal in the ice machine. Because the RO process removes all minerals and metals from the water it can promote the faster growth of microbial mold and slime. If RO water is used, Ice-O-Matic recommends the water pH is verified to be a neutral 7.0 to minimize the corrosive effects. Incorrect cleaners, sanitizers, and RO water that does not have a neutral pH could void
the machine’s warranty.
Drains
All drain lines must be installed per local codes. Flexible tubing is not recommended. Route bin drain, purge drain and water condenser drain individually to a floor drain. The use of condensate pumps for draining water is not recommended. Ice-O-Matic assumes no responsibility for improperly installed equipment.
Note: The purge drain fitting is plastic: DO
NOT apply heat to purge drain area; DO NOT
over-tighten drain connection
All drain lines must be installed per local codes. The purge drain should be a minimum of 3/4 inch O.D. tubing. The condenser drain on water cooled units should be 1/2 inch O.D. minimum. The drain line fittings on Ice-O-Matic bins are 3/4 FPT. The bin drain should be a minimum of 3/4 inch O.D. Cold water drains should be insulated to prevent condensation from forming.
2
ELEVATION SERIES INSTALLATION GUIDELINES
Clearance Requirements
Self-contained air cooled ice machines should have a minimum of 6 inches (15cm) of clearance at the rear, top, and sides for proper air circulation and adequate space for serviceability.
Self-contained air-cooled ice machines exhaust air out of the top and right side. There are two alternative air exhaust options. Option A (top exhaust bias): minimum of 6 inches (15cm) of clearance at the rear and top of the ice machine for proper function at maximum operating conditions. Option B (side exhaust bias): minimum of 6 inches (15cm) of clearance at the rear and right side of the ice machine with a minimum of 3 inches (7.5cm) of clearance at the top for proper function at maximum operating conditions.
Appropriate space should be allowed for proper serviceability of the machine. Excess time to gain access for serviceability is not covered under warranty.
Stacking
Ice-O-Matic does not endorse stacking ice machines.
Dispenser Application
A thermostatic bin control kit should be installed if the CIM Cube ice machine is placed on a dispenser. A bin top may or may not be required and should be secured to the dispenser.
Caution: Electrical connection must be made or a cord
installed by a qualified electrician
an electrical fire.
or there is danger of
Adjustments
Level the machine within 1/8 inch in all directions. Check the water in the Water Sump for proper level. Check the ice bridge for proper thickness.
Check the Water Regulating Valve adjustment if water cooled.
Secure the machine on top of the bin or dispenser. Attach the ice machine to the bin with the mounting straps provided with the bin or dispenser. Insure that the back of the ice machine is flush with the back of the bin. Proper functioning of the Bin Door requires the door, when it is opened, to be in a stable position.
If the ice machine is too far forward on the bin, the opened door may not be stable, resulting in an unexpected closing of the bin door. If the ice machine is to be mounted on a bin or dispenser other than an Ice-O-Matic, refer to the manufacturers instructions for machine mounting. Ice-O-Matic will not be responsible for damage or injury that results from unexpected closing of the bin door as a result of the ice machine being too far forward on the bin.
Electrical Specifications
Refer to the serial plate at the rear of the ice machine to make sure proper voltage and circuit breaker size have been supplied. Make sure the machine is on a dedicated circuit. European installations require that the electrical supply fixed wiring must be provided with a disconnect means having a separation of at least 3mm in all poles. The ice machines are provided without electrical cord set and are designed and agency approved to be permanently connected.
Units are not approved for GFI outlets
an
3
ELEVATION SERIES REMOTE CONDENSER GUIDELINES
Remote Condenser Installation
For proper operation of the ice machine, the following installation guidelines must be followed. Failure to
do so may result in loss of production capacity, premature part failure, and may void all warranties.
Use the following for planning the placement of the remote condenser relative to the ice machine
Location Limits
Remote condenser location must not exceed ANY of the following:
Maximum rise from the ice machine to the
remote condenser is 35 physical feet.
Maximum drop from the ice machine to
the remote condenser is 10 physical feet. Physical line set maximum length is 75 ft. Calculated
line set length maximum is 100
ft. A m b i en t o p e ra t i n g te m p e r at u r e s :
-20°F (-28.9°C) to 120°F (48.9°C)
Install and attach the remote condenser to the roof of the building using the methods and practices of construction that conform to the local building codes, including having a roofing contractor secure the remote condenser to the roof.
Have an electrician connect the remote condenser fan motor wires to the ice machine using the junction box at the back of the machine.
Roof Attachment
Calculation Formula
Drop = dd x 6.6
(dd = drop distance (ft.))
Rise = rd x 1.7
(rd = rise distance (ft.))
Horizontal Run = hd
(hd = horizontal distance (ft.))
Calculated Line Length = Drop + Rise + Horizontal Run
Configurations that do NOT meet these
requirements must receive written authorization
from Ice-O-Matic. This includes multi-pass or rack
system remote condensers
DO NOT: Route a line set that rises, then falls, then rises or a line set that falls, then rises, then falls
Remote Condenser Location
Pre-charged line sets are available in 25, 40, or 75 foot length to connect the ice machine to the remote condenser. Select the best available location, protecting the remote condenser from extremes of dirt, dust and sun. Meet all applicable building codes. The services of a licensed electrician may be required.
Pre-charged Line Set Routing
CAUTION: Do not connect the pre-charged tubing until all routing and forming of the tubing has been
completed. See the coupling instructions for
connecting information
Each set of pre-charged tubing refrigerant lines consists of a 3/8 diameter liquid line and 1/2 inch diameter discharge line. Both ends of each line have quick connect couplings, one end of the line set has a Schrader valve connection.
Note: the openings in the building or ceiling or wall,
listed in the next step, are the minimum sizes
recommended for passing the refrigerant lines through.
Have a roofing contractor cut a minimum hole for the refrigerant lines of 2.50 inch. Check local codes, a separate hole may be required for the electrical power to the condenser.
CAUTION: DO NOT KINK OR CRIMP
REFRIGERANT TUBING WHEN INSTALLING
IT
4
ELEVATION SERIES REMOTE CONDENSER GUIDELINES
Route the refrigerant lines through the roof opening. Follow straight line routing whenever possible. Any excess tubing MUST remain with the building. Spiral the excess length of pre­charged tubing inside the building. Use a horizontal spiral to avoid any traps in the lines. Have the roofing contractor seal the holes in the roof per local codes.
The following remote ice makers incorporate the Mixing Valve in the condenser. This configuration allows up to a 100 foot calculated remote line set run. Reference the diagram on the next page to calculate the maximum 100 ft. line set run. Maximum actual line set run is limited to 100 ft. Add 1/4 oz. of refrigerant for each actual foot from 75 to 100 ft. actual line set run.
CAUTION: The couplings on the sets of pre-charged
lines are self sealing when installed properly.
Carefully follow the instructions in the Remote
Condenser manual
CIM Machine Model Number Remote Condenser Model Number
CIM0530R VRC1001B/RCA1001
CIM0535R VRC1061B/RCA1061
CIM0636R VRC1061B/RCA1061
CIM0825R/0826R/0835R/0836R/0837R
VRC2061B/RCA2061
CIM1125R/1126R/1135R/1136R/1137R VRC2061B/RCA2061
CIM1446R/1447R VRC2661/RCA3061
CIM1545R/1845R VRC2661/RCA3061
CIM2046R/2047R VRC5061B/RCA3561
*Verify the CIM machine is compatible with the remote condenser.
For more information contact your Ice-O-Matic distributor