IBM storage products
Quick installation guide
Ultrastar 2XP
SCSI
Models: DCHS-04F, DCHS-04W, DCHS-04E,
DCHS-04S, DCHS-04U, DCHS-04X, DCHS-04Y,
DCHS-09F, DCHS-09W, DCHS-09E, DCHS-09S,
DCHS-09U, DCHS-09X, DCHS-09Y
Handling precautions
1. Do not cover the breather hole! Covering the
breather hole may result in loss of data.
2. Do not press on the drive! Do not apply any force
to the drive during handling or installation.
3. Always handle the drive with care to prevent
damage from shock, vibration, or electrostatic discharge (ESD).
4. Do not open the static-protective bag containing the
drive until required. Static electricity can damage the
drive.
5. Turn off and unplug your computer. Remove cover.
6. When installing the drive, touch a grounded,
unpainted metal surface with the static-protective
package containing the drive for at least two seconds.
(This drains static electricity from the package and
from your body.)
7. Handle the drive carefully by the edges. Do not
touch any exposed printed circuit board.
8. Save the drive packaging material including the
ESD bag in the event that the drive must be returned.
Place the drive in an anti-static bag before placing it in
the shipping container. The warranty will be void if
the drive is not returned in IBM approved packaging.
Quick installation procedure
Note: It is advisable to backup all data before
proceeding with the installation.
This procedure may require use of a bootable System
Diskette containing FDISK.COM and FORMAT.COM.
Setting the address
1. Each drive on the SCSI bus must have a unique
address. Fifty-pin (Narrow SCSI) devices have eight
possible addresses (0-7) with address 7 (highest priority) normally reserved for the controller. Sixty- eight
pin (Wide SCSI) devices have 16 possible addresses.
2. SCSI address bits 3 (68- & 80-pin models only), 2,
1, and 0 of the 32-pin Option Jumper Block are used
to select the SCSI device ID.
Reserved
External
Reserved
Write
Protect
+5V
Activity LED
Autostart
Delay
Reserved
Disable Sync
Disable SCSI
Negotiations
Parity
Disable Unit
Attention
Disable Wide Negotiations
1 2
Termination
Power Enable
AddressBit 0Bit 1Bit 2Bit 3
0offoffoffoff
1onoffoffoff
2offonoffoff
3ononoffoff
4offoffonoff
5onoffonoff
6*offononoff
7onononoff
8offoffoffon
9onoffoffon
10offonoffon
11ononoffon
12offoffonon
13onoffonon
14offononon
15onononon
Auto
Start
Blank
SCSI Address Bit
3 2 1 0
1234567
GND GND
GND
8 1011121314151617181920212223242526272829303132
Reserved
Enable Active
Termination
Note: For attachment to a Macintosh, place jumpers on pins 29
& 30 to Disable Unit Attention and pins 11 & 12 for Auto Start.
*Shipping default ID
Bit 3 does not exist on 50-pin models.
In the table above, “off” means a jumper is not in place and “on”
means a jumper is in place.
IBM Hard Disk Drive Technical Support Center version 3.0
Page 1
IBM storage products
Aux Connector Pin 1
Power Pin 1
SCSI Pin 1
::::::
Pin 35 Pin 2
Attaching the drive
1. Turn off the computer, unplug the power cord and
open the case.
2. The DCHS drive requires Active Termination on
both ends of the SCSI cable (the SCSI controller
normally provides internal termination for one end of
the cable). If the DCHS drive is the only device on the
SCSI cable, attach it to the end of the cable furthest
from the controller and enable termination by placing
a jumper across pins 13 and 14 of the Option Jumper
Block. If the drive is attached to a cable that contains
other devices and the new drive is not attached to the
end of the cable, the jumper across pins 13 and 14
must be removed and Active Termination must be
supplied by the device at the end of the cable.
3. Select the other option jumpers as required by your
computer.
4. Attach the power connector.
Mounting the drive
1. Mount the drive securely, using the appropriate
brackets or rails, in any axes, using four 6-32 UNC
metric screws in the bottom or side mounting holes.
2. The maximum screw insertion depth for mounting
is 3.8 mm (.15 in).
Configuring your computer
1. Plug in the power cord, insert the System Diskette
and power on your computer. Your computer may
detect a configuration change and prompt you to proceed to the Setup screen. If so, proceed to step 3.
2. If your computer does not prompt you to enter reconfiguration, enter your computer’s Setup, typically
by key selection or keyboard combinations during
power-on or during a reboot. Refer to your computer’s
documentation for the proper key sequence.
3. Follow the Setup menu to configure your computer
with your new SCSI drive. It may be necessary to
restart your computer for the changes to take effect.
Partitioning and formatting (using DOS 5.0 or
later)
Caution! Be sure that you select the correct hard
drive. Partitioning and formatting will erase all data.
1. At the DOS prompt type FDISK, press [ENTER],
and follow the instructions on the screen.
2. To format the primary system drive, type FORMAT
C:/S at the DOS command prompt and press
[ENTER]. The /S parameter makes C: the operating
system startup drive.
3. To format a second drive (not C:), type FORMAT X:
(where X is the drive letter assigned by FDISK) at the
DOS prompt and press [ENTER]
4. Remove the diskette and restart your computer.
The installation is complete.
If your system will not boot up after complete installation, recheck all settings. If the system still fails to
boot up, remove the new drive to return the system to
its original configuration and call the IBM Hard Disk
Drive Technical Support Center.
®
© International Business Machines Corporation 1999
www.ibm.com/harddrive
IBM Hard Disk Drive Technical Support Center
Dept. D8M
3605 Highway 52 North
Rochester MN 55901
Telephone: 888.IBM.5214 or 507.253.4110
Fax: 507.253.DRIVE
E-mail: drive@us.ibm.com
Singapore Technical Support Center
Telephone: 65.840.9292
E-mail: drive@sg.ibm.com
IBM Systems Storage Division
5600 Cottle Road
San Jose CA 95193
www.ibm.com/storage
Asia-Pacific Headquarters: 65.320.1234
European Headquarters: 44.01.705.561.871
Japan Sales Branch Office: 81.46645.1039
Printed in the United States of America
01-99
All Rights Reserved
IBM is the registered trademark of International Business Machines Corporation.
Other company, product, and service names may be trademarks or service marks of others.
Produced by the IBM Hard Disk Drive Technical Support Center.
OEM Ultrastar 2XP Model DCHS Hardware/Functional Specification, version 5.51
Ultrastar 2XP SCSI Models Logical Interface Specification, version 2.03
Product Description data represents IBM’s design objectives and is provided for comparative purposes; actual results may vary based on a variety of factors. This product data
does not constitute a warranty. Questions regarding IBM’s warranty terms or methodology used to derive this data should be referred to the IBM Hard Disk Drive Technical
Support Center. Data subject to change without notice.
Date: 8 January 1999
IBM Hard Disk Drive Technical Support Center version 3.0
Page 2