Hyundai HSH-I073NBE, HSH-I093NBE, HSH-I123NBE, HSH-I183NBE, HSH-I243NBE Service Manual

HYUNDAI
WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS
SERVICE MANUAL
Models
No.TE121023
HSH-I073NBE HSH-I093NBE
HSH-I123NBE HSH-I183NBE HSH-I243NBE
IMPORTANT NOTICE
This service manual is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair the appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
The information, specifications and parameter are subject to change due to technical modification or improvement without any prior notice. The accurate specifications are presented on the nameplate label.
How to order spare parts
To have your order filled promptly and correctly, please furnish the following information:
1. Model No. with Indoor or Outdoor
2. No. in the Explosion View
3. Part Name
4. The quantity you ordered
TCL Air Conditioner Service ManualTCL Air Conditioner Service ManualTCL Air Conditioner Service Manual
Air Conditioner Service Manual
2
Summary and features
Panel BM-S For fixed t
ype
Air Conditioner Service Manual
Panel BM-WPanel Z
12K Outdoor Unit7K/9K Outdoor Unit
IHSH-I123NBE OHRH-I123NBE
18K Outdoor Unit 24K Outdoor Unit
Remarks
Fixed type
220~240V/50Hz)
IHSH-I183NBE OHRH-I183NBE IHSH-I243NBE OHRH-I243NBE
I: HSH-L093NDC-W O: HRH-L093NDC-W
DC inverter
220~240V/50Hz)
Models
For DC inverter
I: HSH-L123NDC-W O: HRH-L123NDC-W
I: HSH-L093NDC-S O: HRH-L093NDC-S I: HSH-L123NDC-S O: HRH-L123NDC-S
IHSH-I073NBE OHRH-I073NBE IHSH-I093NBE OHRH-I093NBE
3
COOLING HEATING
2200 2250
890 810
400 430
1300/1200/1100 1250/1150/1050
Technical specifications
Air Conditioner Service Manual
Net Weight /Gross Weight (kg)
/7.8
Sound Power Level dB (A) (H/M/L)
Dimension of Package (L/W/H) ( mm)
805×305×255
Dimension (W/H/D) ( mm)
Row-Fin Gap(mm) 1-1.5
Sound Pressure Level dB (A) (H/M/L)
Fuse (A)
PCB 3.15A
Output of Swing Motor (W)
<1
Swing Motor Model
GBJDJ-01
Coil length (l) X height (H) Xcoil width (L)
544*231*12.7
Ф7
Evaporator Hydrophilic aluminum fin-copper tube
Diameter-Length (mm) φ88.8×545
Indoorunit
Model of Indoor Unit HSH-I073NBE
Fan Type Cross flow fan
Fan Motor RLA(A) 0.16
Fan Motor Capacitor (μF) 1.5
Pipe Diameter (mm)
Input of Heater (W) /
Fan Motor Speed (r/min) (SH/H/M/L) Output of Fan Motor (W) 12
Air Flow Volume (m3/h)
Rated Frequency
Energy Class A/A
EER / C.O.P (W/W)
Dehumidifying Volume (l/h) 0.6
Total Capacity (W) Power Input (W) Rated Input (W) Rated Current (A)
Model HSH-I073NBE/I HRH-I073NBE/O
50Hz
Function Rated Voltage 220-240V
Product Code /
4
Air Conditioner Service Manual
Length (m)
Max Distance
Height (m)
Connection
Pipe
Length (m) 3
Dimension of Package (L/W/H)( mm) 745x550x353
Gas Pipe (mm) Ф9.52(3/8)
Outer Diameter
Liquid Pipe (mm) Φ6(1/4'')
Gas additional charge(g/m) 20
Refrigerant Charge (kg) 440
Net Weight /Gross Weight (kg) 23.3/25.3
Moisture Protection IP24
Dimension (W/H/D) ( mm) 600x500x232
Sound Power Level dB (A) (H/M/L)
Sound Pressure Level dB (A) (H/M/L) 50
Permissible Excessive Operating Pressure fo
r
theSuction Side(MPa)
0.65
Permissible Excessive Operating Pressure for the Discharge Side(MPa)
2.8
Air Flow Volume of Outdoor Unit(m3/h) 1415
Isolation I
Climate Type T1
Defrosting Method Auto defrost
Fan Diameter (mm) φ324×119
Fan Type Axial fan
Rows-Fin Gap(mm) 1-1.8
Fan Motor Capacitor (μF) 2
Fan Motor RLA(A) 0.37
Output of Fan Motor (W) 25
Fan Motor Speed (rpm) 895
Coil length (l) X height (H)Xcoil width (L) 621*462*12.7
Overload Protector B145-140-141E
Pipe Diameter (mm) Φ7
Condenser Hydrophilic aluminum fin-copper tube
Working Temp Range (ºC) 18-43
Starting Method Capacitor
Throttling Method Capillary
QING'AN
Compressor Power Input(W) 780±5%
Compressor RLA(A) 3.8
L.R.A. (A) 19
Outdoorunit
Model of Outdoor Unit HRH-I073NBE
Compressor Type Rotary
Compressor Model YZG-E22RY2
Compressor Manufacturer/trademark
Product Code /
5
COOLING HEATING
2700 2780
1085 1000
430 430
1150/1050/950 1150/1050/950
Air Conditioner Service Manmual
Dimension (W/H/D) ( mm)
718x240x180
Net Weight /Gross Weight (kg)
6.2/7.8
Dimension of Package (L/W/H) ( mm)
805×305×255
Coil length (l) X height (H) Xcoil width (L)
544*231*12.7
Sound Power Level dB (A) (H/M/L)
Sound Pressure Level dB (A) (H/M/L) 36/34/32
Fuse (A)
PCB 3.15A
Output of Swing Motor (W)
<1
Swing Motor Model
GBJDJ-01
0.16
Row-Fin Gap(mm) 1-1.5
Pipe Diameter (mm) Ф7
Evaporator Hydrophilic aluminum fin-copper tube
EER / C.O.P (W/W)
Fan Motor Capacitor (μF) 1.5
Input of Heater (W) /
Fan Motor Speed (r/min) (SH/H/M/L) Output of Fan Motor (W) 12
Indoorunit
Model of Indoor Unit HSH-I093NBE
Energy Class A/A
Diameter-Length (mm) φ88.8×545
Fan Type Cross flow fan
Fan Motor RLA(A)
Product Code /
1.0
Total Capacity (W) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (m3/h) Dehumidifying Volume (l/h)
Rated Frequency 50Hz
Function Rated Voltage 220-240V
Model HSH-I093NBE/I HRH-I093NBE/O
6
Air Conditioner Service Manmual
Connection
Pipe
Length (m)
Max Distance
Height (m)
Net Weight /Gross Weight (kg) 23.4/25.5
Gas Pipe (mm) Ф9.52(3/8)
Outer Diameter
Liquid Pipe (mm) Φ6(1/4'')
Gas additional charge(g/m) 20
Length (m) 3
Refrigerant Charge (kg) 470
Permissible Excessive
O
perating Pressure fo
r
theDischarge Side(MPa)
2.8
Dimension of Package (L/W/H)( mm) 745x550x353
Dimension (W/H/D) ( mm) 600x500x232
Sound Power Level dB (A) (H/M/L)
Sound Pressure Level dB (A) (H/M/L) 52
Permissible Excessive Operating Pressure for theSuction Side(MPa)
0.65
Fan Type Axial fan
Moisture Protection IP24
Isolation I
Climate Type T1
Defrosting Method Auto defrost
Fan Diameter (mm) φ324×119
Coil length (l) X height (H)Xcoil width (L) 621*462*12.7
Air Flow Volume of Outdoor Unit(m3/h) 1415
Fan Motor Capacitor (μF) 2
Fan Motor RLA(A) 0.37
Output of Fan Motor (W) 25
Fan Motor Speed (rpm) 895
Throttling Method Capillary
Rows-Fin Gap(mm) 1-1.8
Pipe Diameter (mm) Φ7
Condenser Hydrophilic aluminum fin-copper tube
Working Temp Range (ºC) 18-43
Starting Method Capacitor
B175-145B-141C
Compressor Power Input(W) 930±5%
Compressor RLA(A) 4.3
Outdoorunit
Model of Outdoor Unit HRH-I093NBE
L.R.A. (A) 21
Compressor Type Rotary
Compressor Model 44A233AJ-FEKC
Overload Protector
Compressor Manufacturer/trademark RECHI
Product Code /
7
COOLING HEATING
3520 3660
1420 1310
530 530
1270/1170/1000 1250/1150/1000
Air Conditioner Service Manmual
Net Weight /Gross Weight (kg)
7/8.7
855×305×255
Dimension (W/H/D) ( mm)
770x240x180
Sound Power Level dB (A) (H/M/L)
39/36/34
Fuse (A)
PCB 3.15A
Output of Swing Motor (W)
<1
GBJDJ-01
Coil length (l) X height (H) Xcoil width (L)
604*231*25.4
Row-Fin Gap(mm) 2-1.8
Ф7
Evaporator Hydrophilic aluminum fin-copper tube
Diameter-Length (mm) φ90.8×602
HSH-I123NBE
Fan Type Cross flow fan
Fan Motor RLA(A) 0.16
Fan Motor Capacitor (μF) 1.5
/
Fan Motor Speed (r/min) (SH/H/M/L) Output of Fan Motor (W) 12
Rated Input (W) Rated Current (A) Air Flow Volume (m3/h)
Input of Heater (W)
Indoorunit
Model of Indoor Unit
Pipe Diameter (mm)
Swing Motor Model
Sound Pressure Level dB (A) (H/M/L)
Dimension of Package (L/W/H) ( mm)
Energy Class A/A
EER / C.O.P (W/W)
Dehumidifying Volume (l/h)
Rated Frequency 50Hz
Function Rated Voltage 220-240V
1.5
Total Capacity (W) Power Input (W)
Product Code /
Model HSH-I123NBE/I HRH-I123NBE/O
8
Air Conditioner Service Manmual
Length (m) 3 Gas additional charge(g/m) 20
Length (m) 15
Max Distance
Height (m) 5
Connection
Pipe
Gas Pipe (mm) Ф9.52(3/8)
Outer Diameter
Liquid Pipe (mm) Φ6(1/4'')
Sound Pressure Level dB (A) (H/M/L) 55
Refrigerant Charge (kg) 670
Net Weight /Gross Weight (kg) 29.7/32.8
Dimension of Package (L/W/H)( mm) 803*590*361
Dimension (W/H/D) ( mm) 700x552x256
Sound Power Level dB (A) (H/M/L)
Defrosting Method Auto defrost
Permissible Excessive
O
perating Pressure fo
r
theSuction Side(MPa)
0.7
Permissible Excessive
O
perating Pressure fo
r
theDischarge Side(MPa)
2.9
Moisture Protection IP24
Isolation I
Climate Type T1
Output of Fan Motor (W) 31
Fan Diameter (mm) φ401×119
Fan Type Axial fan
Air Flow Volume of Outdoor Unit(m3/h) 2040
Fan Motor Capacitor (μF) 2.5
Fan Motor RLA(A) 0.45
Working Temp Range (ºC) 18-43
Fan Motor Speed (rpm) 860
Coil length (l) X height (H)Xcoil width (L) 711*504*12.7
Rows-Fin Gap(mm) 1-1.5
Pipe Diameter (mm) Φ7
Condenser Hydrophilic aluminum fin-copper tube
30
Starting Method Capacitor
Throttling Method Capillary
Overload Protector B290-150B-241E
Compressor Type Rotary
Compressor Model 48A313PM-55KF
Compressor Manufacturer/trademark RECHI
Product Code /
Outdoorunit
Model of Outdoor Unit HRH-I123NBE
Compressor Power Input(W) 1245±5%
Compressor RLA(A) 5.8
L.R.A. (A)
9
COOLING HEATING
5280 5420
2135 1950
760 780
1300/1220/1150 1250/1150/1050
Air Conditioner Service Manmual
Dimension (W/H/D) ( mm)
900x280x202
Net Weight /Gross Weight (kg)
9.3/11.8
Dimension of Package (L/W/H) ( mm)
985x365x298
Coil length (l) X height (H) Xcoil width (L)
705*315*25.4
Sound Power Level dB (A) (H/M/L)
Sound Pressure Level dB (A) (H/M/L) 48/46/44
Fuse (A)
PCB 3.15A
Output of Swing Motor (W)
<1
Swing Motor Model GBJDJ-01L
0.30
Row-Fin Gap(mm) 2-1.6
Pipe Diameter (mm) Ф7
Evaporator Hydrophilic aluminum fin-copper tube
EER / C.O.P (W/W)
Fan Motor Capacitor (μF) 1.5
Input of Heater (W) /
Fan Motor Speed (r/min) (SH/H/M/L) Output of Fan Motor (W) 23
Indoorunit
Model of Indoor Unit HSH-I183NBE
Energy Class A/A
Diameter-Length (mm) φ94×709
Fan Type Cross flow fan
Fan Motor RLA(A)
2
Total Capacity (W) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (m3/h) Dehumidifying Volume (l/h)
Rated Frequency 50Hz
Function Rated Voltage 220-240V
Product Code /
Model HSH-I183NBE/I HRH-I183NBE/O
10
Air Conditioner Service Manmual
Connection
Pipe
Length (m) 15
Max Distance
Height (m) 5
Net Weight /Gross Weight (kg) 36.5/39.6
Gas Pipe (mm) Φ12(1/2'')
Outer Diameter
Liquid Pipe (mm) Φ6(1/4'')
Gas additional charge(g/m) 30
Length (m) 4
Refrigerant Charge (kg) 1050
Permissible Excessive Operating Pressure fo
r
theDischarge Side(MPa)
29
Dimension of Package (L/W/H)( mm) 863*590*361
Dimension (W/H/D) ( mm) 760x552x256
Sound Power Level dB (A) (H/M/L)
Sound Pressure Level dB (A) (H/M/L) 58
Permissible Excessive Operating Pressure fo
r
theSuction Side(MPa)
0.75
Fan Type Axial fan
Moisture Protection IP24
Isolation I
Climate Type T1
Defrosting Method Auto defrost
Fan Diameter (mm) φ409×132
Coil length (l) X height (H)Xcoil width (L) 768*510*19.05
Air Flow Volume of Outdoor Unit(m3/h) 2340
Fan Motor Capacitor (μF) 3
Fan Motor RLA(A) 0.47
Output of Fan Motor (W) 45
Fan Motor Speed (rpm) 850
Throttling Method Capillary
Rows-Fin Gap(mm) 1-1.5
Pipe Diameter (mm) Φ9.52
Condenser Hydrophilic aluminum fin-copper tube
Working Temp Range (ºC) 18-43
Starting Method Capacitor
IOL
Compressor Power Input(W) 1650
Compressor RLA(A) 7.7
Outdoorunit
Model of Outdoor Unit HRH-I183NBE
L.R.A. (A) 40
Compressor Type Rotary
Compressor Model ASH201SV-C8LU
Overload Protector
Compressor Manufacturer/trademark HIGHLY
Product Code /
11
COOLING HEATING
7030 7180
2830 2575
760 780
1350/1250/1150 1350/1250/1150
Air Conditioner Service Manmual
Net Weight /Gross Weight (kg)
9.3/12.2
985x365x298
Dimension (W/H/D) ( mm)
x280x202
Sound Power Level dB (A) (H/M/L)
48/46/44
Fuse (A)
PCB 3.15A
Output of Swing Motor (W)
<1
GBJDJ-01L
Coil length (l) X height (H) Xcoil width (L)
705*315*25.4
Row-Fin Gap(mm) 2-1.4
Ф7
Evaporator Hydrophilic aluminum fin-copper tube
Diameter-Length (mm) φ94×709
HSH-I243NBE
Fan Type Cross flow fan
Fan Motor RLA(A) 0.30
Fan Motor Capacitor (μF) 1.5
/
Fan Motor Speed (r/min) (SH/H/M/L) Output of Fan Motor (W) 23
Rated Input (W) Rated Current (A) Air Flow Volume (m3/h)
Input of Heater (W)
Indoorunit
Model of Indoor Unit
Pipe Diameter (mm)
Swing Motor Model
Sound Pressure Level dB (A) (H/M/L)
Dimension of Package (L/W/H) ( mm)
Energy Class A/A
EER / C.O.P (W/W)
Dehumidifying Volume (l/h)
Rated Frequency 50Hz
Function Rated Voltage 220-240V
2.4
Total Capacity (W) Power Input (W)
Product Code /
Model HSH-I243NBE/I HRH-I243NBE/O
12
Air Conditioner Service Manmual
Length (m) 4 Gas additional charge(g/m) 30
Length (m) 15
Max Distance
Height (m) 5
Connection
Pipe
Gas Pipe (mm) Φ15.88(5/8'')
Outer Diameter
Liquid Pipe (mm) Φ9.52(3/8'')
Sound Pressure Level dB (A) (H/M/L) 60
Refrigerant Charge (kg) 1380
Net Weight /Gross Weight (kg) 50.2/54.3
Dimension of Package (L/W/H)( mm) 1037x705x433
Dimension (W/H/D) ( mm) 902x650x307
Sound Power Level dB (A) (H/M/L)
Defrosting Method Auto defrost
Permissible Excessive Operating Pressure fo
r
theSuction Side(MPa)
0.8
Permissible Excessive
O
perating Pressure fo
r
theDischarge Side(MPa)
30
Moisture Protection IP24
Isolation I
Climate Type T1
Output of Fan Motor (W) 95
Fan Diameter (mm) φ470×173
Fan Type Axial fan
Air Flow Volume of Outdoor Unit(m3/h) 3350
Fan Motor Capacitor (μF) 4
Fan Motor RLA(A) 0.92
Working Temp Range (ºC) 18-43
Fan Motor Speed (rpm) 850
Coil length (l) X height (H)Xcoil width (L) 901*609*19.05
Rows-Fin Gap(mm) 1-1.5
Pipe Diameter (mm) Φ9.52
Condenser Hydrophilic aluminum fin-copper tube
60
Starting Method Capacitor
Throttling Method Capillary
Overload Protector IOL
Compressor Type Rotary
Compressor Model ASH264SV-C8LU
Compressor Manufacturer/trademark HIGHLY
Product Code /
Outdoorunit
Model of Outdoor Unit HRH-I243NBE
Compressor Power Input(W) 2215
Compressor RLA(A) 10.3
L.R.A. (A)
13
COOLING HEATING
2703 (1110-3080) 2724 (1230-3810)
1050 1220
4.8 5.6
600 600
HSH-L093NDC-W HSH-L093NDC-S
1200/1050/900
1200/1050/900
Fuse (A)
PCB 3.15A
Net Weight /Gross Weight (kg)
8/10
Dimension of Package (L/W/H) ( mm)
885*366*278
Dimension (W/H/D) ( mm)
800*280*185
Sound Power Level dB (A) (H/M/L)
Sound Pressure Level dB (A) (H/M/L) 38/36/34
Evaporator Hydrophilic aluminum fin-copper tube
Output of Swing Motor (W)
<1
Swing Motor Model
GBJDJ-01
Coil length (l) X height (H) Xcoil width (L)
657x315x25.4
Row-Fin Gap(mm) 2-1.5
Pipe Diameter (mm) Ф
7
EER / C.O.P (W/W)
Fan Motor Capacitor (μF) 1.5
Input of Heater (W) /
Fan Motor Speed (r/min) (SH/H/M/L) Output of Fan Motor (W) 18
Indoorunit
Model of Indoor Unit
Energy Class A/A
Diameter-Length (mm) φ98×622
Fan Type Cross flow fan
Fan Motor RLA(A) 0.23
0.8
Total Capacity (W) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (m3/h) Dehumidifying Volume (l/h)
Rated Frequency 50Hz
Function Rated Voltage 220-240V
Product Code /
Air Conditioner Service Manmual
Model HSH-L093NDC HRH-L093NDC
14
HRH-L093NDC-W HRH-L093NDC-S
Air Conditioner Service Manmual
Connection
Pipe
Length (m)
Max Distance
Height (m)
Net Weight /Gross Weight (kg) 32/36
Gas Pipe (mm) Ф9.52(3/8)
Outer Diameter
Liquid Pipe (mm) Φ6(1/4'')
Gas additional charge(g/m) 20
Length (m) 3
Refrigerant Charge (kg) 1002
P
ermiss
ible E
xcessive Operating Pressure fo
r
theDischarge Side(MPa)
4.5
Dimension of Package (L/W/H)( mm) 863x590x361
Dimension (W/H/D) ( mm) 760x552x256
Sound Power Level dB (A) (H/M/L)
Sound Pressure Level dB (A) (H/M/L) 52
Permissible Excessive
O
perating Pressure fo
r
theSuction Side(MPa)
1.9
Fan Type Axial fan
Moisture Protection IP25
Isolation I
Climate Type T1
Defrosting Method Auto defrost
Fan Diameter (mm) φ408×132
Coil length (l) X height (H)Xcoil width (L) 756x510x25.4
Air Flow Volume of Outdoor Unit(m3/h) 2340
Fan Motor Capacitor (μF) 2.5
Fan Motor RLA(A) 0.45
Output of Fan Motor (W) 31
Fan Motor Speed (rpm) 860
Throttling Method Capillary
Rows-Fin Gap(mm) 2-1.5
Pipe Diameter (mm) Φ7
Condenser Hydrophilic aluminum fin-copper tube
Working Temp Range (ºC) 18-44
Starting Method Capacitor
Compressor Power Input(W) 705±5%
Compressor RLA(A) 4.75±5%
Outdoorunit
Model of Outdoor Unit
L.R.A. (A) N.A
Compressor Type Rotary
Compressor Model DA89X1C-20FZ3
Overload Protector INT01L-4639
Compressor Manufacturer/trademark GMCC
Product Code /
15
COOLING HEATING
3503 (1520-3960) 4323 (1610-4840)
1350 /1700
6.1 /7.7
650 650
HSH-L123NDC-W
HSH-L123NDC-S
1280/1100/900 1250/1080/900
Air Conditioner Service Manmual
Net Weight /Gross Weight (kg)
8/10
Sound Power Level dB (A) (H/M/L)
Dimension of Package (L/W/H) ( mm)
885*366*278
Dimension (W/H/D) ( mm)
800*280*185
40/38/36
Fuse (A)
PCB 3.15A
Output of Swing Motor (W)
<1
GBJDJ-01
Coil length (l) X height (H) Xcoil width (L)
657x315x25.4
Row-Fin Gap(mm) 2-1.5
Ф7
Evaporator Hydrophilic aluminum fin-copper tube
Diameter-Length (mm) φ98×622
Cross flow fan
Fan Motor RLA(A) 0.23
Fan Motor Capacitor (μF) 1.5
/
Fan Motor Speed (r/min) (SH/H/M/L) Output of Fan Motor (W) 18
Rated Input (W) Rated Current (A) Air Flow Volume (m3/h)
Input of Heater (W)
Indoorunit
Model of Indoor Unit
Fan Type
Pipe Diameter (mm)
Swing Motor Model
Sound Pressure Level dB (A) (H/M/L)
Energy Class A/C
EER / C.O.P (W/W)
Dehumidifying Volume (l/h)
Rated Frequency 50Hz
Function Rated Voltage 220-240V
1
Total Capacity (W) Power Input (W)
Product Code /
Model HSH-L123NDC HRH-L123NDC
16
HRH-L123NDC-W HRH-L123NDC-S
Length (m)
Max Distance
Height (m)
Gas Pipe (mm) Φ12(1/2'')
Outer Diameter
Liquid Pipe (mm) Φ6(1/4'')
Gas additional charge(g/m) 20
Connection
Pipe
Length (m) 3
Sound Pressure Level dB (A) (H/M/L) 55
Refrigerant Charge (kg) 1000
Net Weight /Gross Weight (kg) 32/36
Dimension of Package (L/W/H)( mm) 863x590x361
Dimension (W/H/D) ( mm) 760x552x256
Sound Power Level dB (A) (H/M/L)
Defrosting Method Auto defrost
Permissible Excessive Operating Pressure fo
r
theSuction Side(MPa)
1.9
P
ermiss
ible E
xcessive Operating Pressure fo
r
theDischarge Side(MPa)
4.5
Moisture Protection IP26
Isolation I
Climate Type T3
Output of Fan Motor (W) 30
Fan Diameter (mm) φ408×132
Fan Type Axial fan
Air Flow Volume of Outdoor Unit(m3/h) 2340
Fan Motor Capacitor (μF) 2.5
Fan Motor RLA(A) 0.45
Working Temp Range (ºC) 18-45
Fan Motor Speed (rpm) 900 /770/670
Coil length (l) X height (H)Xcoil width (L) 756x510x25.4
Rows-Fin Gap(mm) 2-1.5
Pipe Diameter (mm) Φ7
Condenser Hydrophilic aluminum fin-copper tube
L.R.A. (A) N.A
Starting Method Capacitor
Throttling Method Capillary
Overload Protector IOL
Compressor Power Input(W) 865±5%
Compressor RLA(A) 4.6±5%
Outdoorunit
Model of Outdoor Unit
Compressor Type Rotary
Compressor Model DA108M1C-81EZ8
Compressor Manufacturer/trademark GMCC
Product Code /
Air Conditioner Service Manmual
17
Louver
Pipes and Power
Air Conditioner Service Manual
18
Air Conditioner Service Manmual
19
Product Dimensions
Outdoor Unit
Indoor Unit
A
B
20 mm
400 mm
57 mm
C
H
G
F
I
K
J D
E
Unit: mm
20
Air Conditioner Service Manual
Capacity A B C D E F G H I J K
7K&9K 718 240 180 600 500 230 271 296 52 376 55
12K 770 240 180 700 552 256 290 328 48 439.2 55
18K 898 280 202 760 552 256 290 328 48 507.8 63
24K 898 280 202 902 650 307 349 399 65 753.5 63
Air Conditioner Service Manual
WIRING DIAGRAM
MODEL:HSH-I073NBE,HSH-I093NBE,HSH-I123NBE INDOOR UNIT:
OUTDOOR UNIT
21
Air Conditioner Service Manual
WIRING DIAGRAM
MODEL:HSH-I183NBE INDOOR UNIT:
OUTDOOR UNIT
22
Air Conditioner Service Manual
WIRING DIAGRAM
MODEL:HSH-I243NBE INDOOR UNIT:
OUTDOOR UNIT
23
Product Dimensions
Outdoor Unit
Indoor Unit
A
B
20 mm
400 mm
57 mm
C
H
G
F
I
K
J D
E
Unit: mm
24
Air Conditioner Service Manual
Capacity A B C D E F G H I J K
9K&12K 800 280 185 760 552 256 290 328 48 507.8 63
Air Conditioner Service Manual
WIRING DIAGRAM
MODEL: HSH-L093NDC-W,HSH-L093NDC-S INDOOR UNIT:
OUTDOOR UNIT
25
Air Conditioner Service Manual
WIRING DIAGRAM
MODEL: INDOOR UNIT:
OUTDOOR UNIT
26
Note: Each mode and relevant function will be further specified in following pages.
Remote controller
1
2
4
3
5
6
7
8
MODE button
ECO button
ON/OFF button
FAN SPEED button
TEMP UP button
TIMER button
SLEEP button
TEMP DOWN button
To select the mode of operation.
In cooling mode,press this button ,the temperature will increase 2 on the base of setting temperature: In heating mode, press this button, the temperature will decrease 2 on the base of setting temperature.
To switch the conditioner on and off.
To select the fan speed of auto/low/mid/high.
To set automatic switching-on/off.
Increase the temperature or time by 1 unit.
To activate the function SLEEP .
Decrease the temperature or time by 1 unit.
Air Conditioner Service Manual
Operation Details
Remote Control
The remote controller is not presetting as Cooling Only Air Conditioner or Heat Pump by manufacturer. Each time after the remote controller replace batteries or is energized, the arrowhead will flashes on the front of
Heat or Cool on LCD of the remote controller. User can preset the remote controller type depending on the air conditioner type you have purchased as follows: Press any button when the arrowhead flashes on the front of Cool , Cooling Only is set. Press any button when the arrowhead flashes on the front of Heat , Heat Pump is set. If you don t press any button within 10 seconds, the remote controller is preset as Heat Pump automatically.
Note :
If the air conditioner you purchased is a Cooling Only one, but you preset the remote controller as Heat Pump, it doesn t bring any matter. But if the air conditioner you purchased is a Heat Pump one, and you preset the remote controller as Cooling Only, then you CAN NOT preset the Heating operation with the remote controller.
1
3
4 5
12
13
10
9
8
7
6
ON
OFF
ON
C
AUTOQUIET POWERFUL
hr DELAY
DRY
FAN
HEAT
TIMER
HEALTHY
AIR SWING
FAN SPEED
2
COOL
FEEL
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
ANTI-MILDEW
SWING SLEEP HEALTHY
DISPLAY RESET
15
16
9
SUPER button
In cooling mode, press this button, the unit will give the maximum cooling temperature with 16
In heating mode, press this button, the unit will give the maximum heating temperature with 31 .
9
SWING button
10
To activate or deactivate of the movement of the
DEFLECTORS .
12
DISPLAY button
To LED display (if present)switch on/off the .
13
HEALTHY button
To switch - on /off HEALTHY funtion.It is a button
which controls the ionizer or plasma generator only for inverter type.
9
RESET button
15
To restart REMOTE CONTROL.
27
Air Conditioner Service Manual
Electronic controller:
1.Automatic mode
1) Initial RT determines the working mode and ST,the mode is determined effective only once unless
A/C shut-down then re-started. If from other modes switches to autoamatic mode (including mode
conversion after shutdown), it should be that the compress stop more than 3 min then temperature
judgement and automatic mode are conducted (it can conduct immediately from fan mode switched
to automatic, the indoor fan stops, three minutes later the response is made and start up). Within 3
min, the output as: Showing the room temperature, indoor fans starts (or anti-cold airflow), the
outdoor fan stops;
2) With memory controller, once being turned off or in case of an accidently power cut, the A/C is able
to retain and restore the original mode when being turned on or the power supply is resumed, if the
auto restart function activated. power-down after power-on; while if the auto restart fundction isn’t
activated, the A/C enters standby state.
Heat pump
Mode Initial RT Initial ST
Cooling
RT26 23
Dehumifying
26℃>RT20 18
Heating
RT20 23
Cooling-only
Mode Initial RT Initial ST
Cooling
RT26 23
Dehumifying
26℃>RT20 18
Ventilating
RT20
Under automatic mode (including from automatic converted into dehumidifying Dry mode), when the
temperature up and down signals from the remote controller is received, the setting temperature ST adjusts correspondingly to the current room temperature plus or minus 1, the automatic regulating temperature range is ± 2℃.
2Cooling mode
1) The control of the compressor a. When RT-ST≥1℃,the compressor is running. b. When RT-ST<-1℃,the compressor is off. c. When -1℃≤RT-ST<1℃, the compressor keeps its original state.
2) Outdoor fan motor and the compressor run simultaneously (except for defrosting).
3) The control of indoor fan motor:
a. Indoor fan motor can operate by automatic, low, middle, and high airflow speed circularly. b. Indoor fan motor’s the automatic airflow speed control Indoor fan motor can operate by automatic
as shown in Figure 1:
Hi
Mid
Lo
RT-ST 1℃ 2℃ 4
Figure 1 Cooling automatic airflow
When the temperature changes lead to changes in airflow speed, the switch can only be made
orderly, and every grade of air flow speed runs 1 minute at least.
28
Air Conditioner Service Manual
3, Dry mode
running into this mode, the Air cond. firstly operates for 3 minutes according to cooling mode (set
temperature is 7) , and then takes the detected backflow air temperature minus 2 as a new set
temperature (the minimum value of 5) and runs according to cooling mode, indoor fan operates at
low-speed, at this moment the setting operation of Fan speed is invalid but Swing is adjustable.
4. Heating mode
On the Heating mode, the room temperature is repaired. After repaired, the room temperature
display on the LED CRT=RT-3℃.
1) The control of the compressor a. When ST-CRT≥1the compressor is running. b. When ST-CRT<-1,the compressor is off. c. When -1≤ST-CRT<1℃, the compressor keeps its original state
2) Outdoor fan motor and the compressor run simultaneously (except for defrosting)
3) The control of indoor fan motor:
a. Indoor fan motor can operate by automatic, low, middle, and high airflow speed circularly. b. indoor fan motor’s the automatic airflow speed control Indoor fan motor can operate by automatic
as shown in Figure 2:
Hi
Mid
Lo
ST-CRT 1℃ 2℃ 4
Figure 2 Heating automatic airflow
When the temperature changes lead to changes in airflow speed, the switch can only be made
orderly, and every grade of air flow speed runs 1 minute at least.
4) Vane motor control: run as set state.
5) 4-way valve control:
a. Under heating mode, the four-way valve maintains well-connected status (including the
compressor stops on set condition, but except for the defrosting process)
b. When the mode switches into the heating mode or start-up, four-way valves will open 5 Seconds
before the compressor starts; while the mode exits from the heating mode or turn off, the four-way
valve will close 2min after after the shut-down the compressor.
6) Defrosting function:
During defrosting, once mode switch, temperature setting signals received, and the buzzer and
display make response immediately, but the other operations won’t implemented until defrosting
finished;
During defrosting, the signals of on-off, timing, sleep, airflow speed ans swing will be responded, but
the airflow speed and swing should be in accordance with anti-cold air rules.
Except the above signal processing during defrosting, no other signals will be dealt with, but only a
loud buzz.
During de
frosting, electrical heating stops compulsively.
Defrosting enter and exit pragram: Option 1with jumper JC
The condition of enter defrosting: run into defrosting once any of condition 1, 2, and 3 met.
29
Air Conditioner Service Manual
Condition 1As shown in figure 3
Defination:
The followings are all required to meet: a. IPT1 settles for IPT1=IPTmax-△IPT(8℃) b. t5≥50min(running time t5≥50min(the compressor runs cumulatively),t5 is removable,and could be less than t1 c. IPT<40℃,and lasts 2min
Running into defrosting on condition 1, the first running time of set defrosting is F (8min); after running
a defrosting cycle, the defrosting time should be determined and adjusted.
Figure 3
Condition 2: When running time is more than or equal to 120 min (compressor is running
accumulatively), the indoor temperature is less than 35 ° C for 2 min sustained. Running into
defrosting under condition 2, defrosting time set is 8 min.
Condition 3: after the compressor is operating for 20min continuously, the indoor temperature is less
than 23 ° C which is anti-cold wind temperature when the fan stops running(including temperature
droping when compressor operating, not including the compressor’s starting course), and the
machine runs into defrosting according to any one condiciton as below) Running into defrosting under
condition 3, defrosting time set is 10 min.
a) Running into the first defrosting in 20 min after start-up.
b) The interval from last defrosting equivalent to or more than 50 min (stopping the compressor or the
machine in standby is allowed in the meantime).
Option 2: No Jumper JC, and no OPT outdoor sensor
when the compressor runs for 45 min, if the indoor coil temperature is less than 40 ° C for 2 min, the
machine runs into defrosting, and lasts for 3min, otherwise when the compressor runs for 120 min,
the machine runs into defrosting automatically and last for 10 min.
Option 3: No jumper JC, but with OPT outdoor sensor
When heating, when the temperature of outdoor unit under heat-exchange is lower than E ° C (-4 ° C),
and the compressor runs for 45 min, then the machine runs into defrosting and last for 10 min.
Option 4. When heating, when the outdoor fan motor stopped but the compressor not stopped
30