Hyundai DHY2500L/E, DHY4000L/E, DHY6000L/E, DHY6000L/E-3, DHY4000SE/3 User Manual

...
MADE UNDER LICENSE OF HYUNDAI CORP. SEOUL, KOREA
OPEN TYPE-DHY2500L/E DHY4000L/E DHY6000L/E/3
SILENT TYPE-DHY4000SE/3 DHY6000SE/3
WELDER TYPE-DHYW180AC DHYW190AC
DIESEL GENERATOR
USER MANUAL
REVIEW MANUAL CAREFULLY TO AVOID PERSONAL INJURY
PREFACE
Thank you for purchasing HYUNDAI diesel generator.
This operation manual will tell you how to operate and service your HYUNDAI diesel gene-
rator set propertly.
Please read this manual before using the generator set to ensure the proper operation. Follow the instructions to keep your generating set in in the best working conditions and extend the life of it. If any comments or problem please contact the place where you bought the generator set or also can contact the manufacturer directly (check contact formular in last page).
It is also strong recommend that you send the receipt form to the manufactures in order to register your product for future problems or complains.
All information in this publication is based on the latest product information available at the time of printing. ITC Power Co.ltd., reserves the right to make changes at any time without notice and without incurring any obligation. No part of this publication may be repro­duced without written permission.
This manual deals with the general items for the HYUNDAI diesel generator set, however this manual may vary with the development of the product in the future.
This manual should be considered a permanent part of the generator and should remain with the generator if resold.
Please give special attention to the warnings and cautions. A safety message alerts you to potential hazards that could hurt you or others. Each safety message is preceded by a safety alert symbol and one of three words, DANGER, WARNING, or CAUTION.
These signal words mean:
You CAN be HURT if you don’t follow instructions.
You CAN be KILLED or SERIOUSLY HURT if you don’t follow instructions.
You CAN be HURT if you don’t follow instructions. Also the machi­ ne can be damage
Non respect the instructions explained in this user manual will avoid the guarantee of the generator set.
Contact Group ITC Power staff for any clarification about the use of the generator here explained. Contact details in the last page.
! DANGER
!
WARNING
!
CAUTION
1
SAFETY INFORMATION
In order to ensure a safety use of the generator please follow the next safety instructions:
1. Check the outside of the generator in order to detect any apparent trouble.
2. The use or good quality oil and diesel is a must.
3. Storage should be in a dry place. Frost damage permanently your group.
Drain your machine completely before storing in a dry hot place.
4. Check and clean filters regularly.
5. Make sure all subset of the machine are right.
6. Exhaust fumes contain carbon monoxide, a very dangerous gas, colorless
and odorless, never use the generator in premises or areas closed. Make sure the group is installed in a location with adequate ventilation or equipped with a smoke extractor.
7. The exhaust temperature rises during the use of the group and still burning
even after shutdown. Take care never to touch or move it to store before being on it is cool enough.
8. Repair your generator shall be made by a qualified person and trained for this
purpose.
9. Do not smoke, do not flame or spark when operating or filling the tank, store
the generator near flammable materials.
10. Store the group in a well ventilated area.
11. Never transport or store your generator in a horizontal or leaning of fuel leak
and / or oil or will permanently damage your machine.
12. Never stop the generator when is load applied, be sure to disconnect any
apparatus from the generating set prior start of prior stop.
13. Do not allow children to operate the engine. Keep children and pets away
from the area of operation.
14. The engine and exhaust become very hot during operation. Keep the gene-
rating set at least 1.5 meter away from buildings and other equipment during operation. Keep flammable materials away, and do not place anything on the engine while it is running.
15. Gasoline is highly flammable and explosive. Turn engine off and let cool
before refueling.
16. To avoid electric shocks or short circuit, do not touch the generating set
when your hands are wet. This generating set is not water proof, so it should not be used in a place exposed to rain, snow or water spray. Use of the generating set in a wet place can cause short circuits and electric shock during operation.
17. The generating set must be grounded to prevent electrical shocks from from
faulty appliances. Please connea lenght of heavy wires between the genera­ting set ground terminal and a external ground source
18. Most applicance motors requiere more than their rated waltage for star-up,
so follow recommendations of your dealer to choose the right power for your applicance.
19. Do not exceed the expecific current limit of any socket.
20. Do not connect directly the generating set to a household circuit.
18. No guarantee will be covered in case of non-compliance of start-up procedu-
res and safety precautions.
2
CONTENTS
1. MAIN TECHNICAL SPECIFICATIONS & DATA
1.1 Main technical specifications and data open type
1.2 Main technical specifications and data soundproof type
1.3 Main technical specifications and data welder type
1.4 Basic parameters
1.4.1 Provide of rated power under following conditions
1.4.2 Working reliable under the following conditions
1.4.3 Working reliable under special conditions
1.4.4 Selection of the right power for the generator
1.5 Name identification and name plate
2. IDENTIFICATION OF THE PARTS
2.1 Control panel LED3
2.2 Control panel LED4
2.3 Control panel LED4 Welder Type
2.3 Identification of the parts soundproof type
2.4 Identification of the parts open type
3. OPERATION OF DIESEL GENERATING SET
3.1 Notes of operating diesel generating set
3.1.1 Preventing of fire
3.1.2 Preventing the suction of exhaust gas
3.1.3 Preventing the damage by high-temperature parts
3.1.4 Preventing the electric shock or short circuit
3.1.5 Other safety points
3.1.6 Charging the battery
3.2 Preparation before starting
3.2.1 Selection of the fuel
3.2.2 Filling in lube oil
3.2.3 Check air cleaner
3.2.4 Checking the generator load
3.2.5 Checking fuel piping
3.3 Checking & operating the engine
3.3.1 Checking lube oil level
3.3.2 Operation in trial
3.4 Starting & operating the generator
3.4.1 Preparation before starting
3.4.2 Starting
3.4.3 Make the inspection during the operation.
3.5 Adding load
3.6 Stop the generator
5
5
6
7
8
8
8
8
9
9
10
10
11
12
13
14
15
15
15
15
15
15
15
15
16
16
16
17
18
18
18
18
18
19
19
19
20
21
21
3
CONTENTS
3.7 Battery
3.8 Control panel
3.9 Welding process
4. MAINTENANCE OF DIESEL GENERATING SET
4.1 Maintenance of diesel generator
4.1.1 Change lube oil
4.1.2 Change/clean the element of air cleaner
4.1.3 Change fuel filter
4.1.4 Check the electrolytic and charge the battery
4.1.5 General maintenance
5. LONG TERM STORAGE
6. TROUBLE SHOOTING AND REMEDY
7. GUARANTEE
8. NOTES
4
22
22
22
23
23
23
24
26
27
27
28
28
29
30
1.1 Main technical specifications and data open type
1.
MAIN TECHNICAL SPECIFICATIONS & DATA
30mA BREAKER
AC230V
AC230V
DIGITAL PANEL
+
-
STARTER SW
ONOFF
START
PRE. HEATER
DC 12V 8.3Amp
FUSE
DC12V 10Amp
FUSE
L
W
H
DHY2500L 610 460 530 630 480 565 Carton
DHY4000L/E 680 460 560 710 480 600 Carton
DHY6000L/E 720 480 600 740 500 645 Carton
DHY6000L/E-3 720 480 600 740 500 645 Carton
Width Height
Model
Length Width HeightLength
Product Size (mm)
Packaging Size (mm)
Package Material
50 / 60 2 / 2.2 kW
2.2 / 2.4 kW 230 / 120-240
9.6 / 22 2x16A / XX LED4 14 30 / 27
76.9 / 77.2 12 / 8.3 17
Diesel D200
4.2 Manual / Elec. start 211
0.75
A2-1 / A2.2-1 2 / 2.2 1 AVR
55/66 58/69 164/340/340
50 / 60 3 / 3.3 kW
3.3 / 3.6 kW 230 / 120-240
14.3 / 30 2x16A / XX LED4 14 21 / 19
77.1 / 77.4 12 / 8.3 17
Diesel D300 6 Manual / Elec. start 296
1.1
A3-1 / A3.3-1 3 / 3.3 1 AVR
68/79 72/83 108/222/293
50 / 60 5 / 5.5 kW
5.5 / 6.0 kW 230 / 120-240
23.9 / 50 2x16A / XX LED4 14 13 / 11.5
77.5 / 78 12 / 8.3 36
Diesel D400 10 Manual / Elec. start 418
1.65
A5-1 / A5.5-1 5 / 5.5 1 AVR
93/108 98/113 102/213/281
50 / 60
6.3 / 6.9 kVA
6.9 / 7.6kVA 400 / 120-240
16.2 / 36 1x 16A/3~ & 1x 16A/1~/ XX
(1)
LED4 14 13
77.5 / 78 12 / 8.3 36
Diesel D400 10 Manual / Elec. start 418
1.65
A5-3 / A5.5-3
6.3 / 6.9
0.8 AVR
93/108 98/113 102/213/281
Generator SetEngine
Alternator
Log.data
Frequency (Hz) Rated Power Max.Power Voltage (V) Current (A) Sockets Display Fuel Tank Capacity (L) Running Time under 50% Load (hr.) Noise Level behind 7 Meters 50% Load (dBA) DC Output (V/A)
(2)
Battery (Ah)
Engine Type Engine Power Output (HP) Start Method Displacement (ml) Oil Capacity (L)
Alternator Rated Power (kVA) Power Factor (Cosφ) Voltage Regulation
N.G.(kg) G.W.(kg) Loading capacity 20/40/40HQ
Generator Model DHY2500L/E DHY4000L/E DHY6000L/E DHY6000L/E-3
(1) Single phase socket thermal protected (2) 100W max. output. 10A fuse protection
Values might vary without prior notice, for updated information please visit our web page
5
1.2 Main technical specifications and data soundproof type
1.
MAIN TECHNICAL SPECIFICATIONS & DATA
(1) Single phase socket thermal protected (2) 100W max. output. 10A fuse protection
Values might vary without prior notice, for updated information please visit our web page
Width Height
Model
Length Width heightLength
Product Size (mm)
Packaging Size (mm)
Package Material
INTELLIGENT CONTROLLER
+
-
ONOFF
START
STARTER SW EMERGENCY STOP
PRE. HEATER
ATS
AC230VAC230V
30mA BREAKER
DC 12V 8.3Amp
FUSE
DHY4000SE 920 520 760 950 570 790 Carton
DHY6000SE 920 520 760 950 570 790 Carton
DHY6000SE-3 920 520 760 950 570 790 Carton
H
L
W
Generator Model DHY4000SE DHY6000SE DHY6000SE-3
Generator SetEngine
Alternator
Frequency (Hz) Rated Power Max.Power Voltage (V) Current (A) Sockets Display Fuel Tank Capacity (L) Running Time under 50% Load (hr.) Noise Level behind 7 Meters 50% Load (dBA) DC Output (V/A)
(2)
Battery (Ah)
Engine Type Engine Power Output (HP) Start Method Displacement (ml) Oil Capacity (L)
Alternator Rated Power (kVA) Power Factor (Cosφ) Voltage Regulation
N.G.(kg) G.W.(kg) Loading capacity 20/40/40HQ
50 / 60
6.3 / 6.9 kVA
6.9 / 7.6 kVA 400 / 120,240
16.2 / 36 1x 16A/3~ & 1x 16A /1~ / XX
(1)
LED4 17 16 / 14.5
72.6 / 72.8 12 / 8.3 36
Diesel D400E 10 Elec. start 418
1.65
A5-3S / A5.5-3S
6.3 / 6.9
0.8 AVR
160 167 68/144/144
50 / 60 5 / 5.5 kW
5.5 / 6.0 kW 230 / 120,240
23.9 / 50 2x16A / XX LED4 17 16 / 14.5
72.6 / 72.8 12 / 8.3 36
Diesel D400E 10 Elec. start 418
1.65
A5-1S / A5.5-1S 5 / 5.5 1 AVR
160 167 68/144/144
Log.data
50 / 60 3 / 3.3 kW
3.3 / 3.6 kW 230 / 120,240
14.3 / 30 2X16A / XX LED4 17 23 / 21 72 / 72.1 12 / 8.3 17
Diesel D300E 6 Elec. star 296
1.1
A3-1S / A3.3-1S 3 / 3.3 1 AVR
150 157 68/144/144
6
Generator SetEngine
Alternator
D-diesel engine AC-welder set
Specifications are subject to continuous product delevopment
width height
Model
thgiehhtdiwhtgneLLength
Product Size (mm)
Packaging Size (mm)
Package Material
Frequency (Hz) Rated Power Max.Power Voltage (V) Rated welding current (A) Rated welding voltage (V) Display Fuel Tank Capacity (L) Running Time under 50% Load (hr.) Noise Level behind 7 Meters (dBA) DC Output (V/A)
(2)
Battery (Ah)
Engine Type Engine Power Output (HP) Start Mothod Displacement (ml) Oil Capacity (L)
Alternator Rated Power (kVA) Power Factor (Cosφ) Voltage Regulation
N.W.(kg) G.W.(kg) Loading capacity 20/40/40HQ
Generator Model DHYW180AC DHYW190AC
DHYW180AC 720 530 580 740 550 610 Carton
DHYW190AC 720 530 580 740 550 610 Carton
50
4.5 kW 5 kW 230 12 180 LED4 14 30
77.5 12 / 8.3 36
Diesel D400 10 Electrical start 418
1.65
A5W
2.5 1 AVR
110 113 102/213/281
50
2.5 kW
(1)
2.8 kW 230 12 190 LED4 14 30
77.5 12 / 8.3 36
Diesel D400 10 Electrical start 418
1.65
A5W190
2.5 1 AVR
112 115 102/213/281
30mA BREAKER
AC230V
AC230V
DIGITAL PANEL
+
-
STARTER SW
ONOFF
START
PRE. HEATER
DC 12V 8.3Amp
FUSE
DC12V 10Amp
FUSE
L
W
H
Log.data
(1) Can not use welding and power generation at the same time Designed for professional use in welding (2) 100W max. output. 10A fuse protection
1.3 Main technical specifications and data welder type
1.
MAIN TECHNICAL SPECIFICATIONS & DATA
7
1.4 Basic parameters
1. MAIN TECHNICAL SPECIFICATIONS & DATA
1.4.1 Provide of rated power under following conditions
table 1
1.4.2 Working reliable under the following conditions
table 2
1.4.3 Working reliable under special conditions
For special conditions appliances the power of the generator must be
correct according the bellow formala and table:
Ph = Pn x K1 x K2
Where:
Ph = Power on the requiered height
Pn = Nominal Power
K1 = 1 for use less than 12hr. Day / 0.9 for use over 12hr. Day
K2 = Coeficient according below table
table 3
Sea level (M) Ambient temperature(°C) Relative humidity 0 20 60%
Sea level (M) Ambient temperature(°C) Relative humidity <1000 5-40 <90%
0 5 10 15 20 25 30 35 40 45
0
- - - - 1 0.98 0.96 0.94 0.92 0.89
200
- - - 0.99 0.97 0.95 0.93 0.92 0.89 0.86
400
- 1 0.98 0.96 0.94 0. 92 0.9 0.89 0. 87 0.84
600
1 0. 87 0.95 0.94 0.92 0.9 0.88 0. 86 0. 84 0.82
800
0.97 0.94 0. 93 0. 91 0.89 0.87 0. 85 0. 84 0.82 0.79
1000
0.94 0.92 0.9 0.89 0.87 0.85 0.83 0.81 0.79 0.77
1500
0.87 0.85 0. 83 0. 82 0.8 0.79 0.77 0. 75 0. 73 0.71
2000
0.81 0.79 0. 77 0. 76 0.74 0.73 0. 71 0. 7 0.68 0.65
2500
0.75 0.74 0. 72 0. 71 0.69 0.67 0. 65 0. 64 0.62 0.6
3000
0.69 0.68 0. 66 0. 65 0.63 0.62 0. 61 0. 59 0.57 0.55
3500
0.64 0.63 0.61 0.6 0.58 0.57 0.55 0.54 0.52 0.5
4000
0.59 0.58 0. 56 0. 55 0.53 0.52 0.5 0. 49 0. 47 0.46
HEIGHT (m.)
TEMPERATURE (Celsius)
HUMIDITY BETWEEN 0-50%
K2
0 5 10 15 20 25 30 35 40 45
0
1 1 1 1 0. 99 0.96 0.94 0.91 0. 88 0.84
200
1 1 1 0.98 0.96 0.93 0.91 0.88 0.85 0.82
400
1 0. 99 0.97 0. 95 0. 93 0.9 0. 88 0.85 0.82 0.79
600
0.99 0.97 0. 95 0.93 0.91 0. 88 0.86 0.85 0.8 0.77
800
0.96 0.94 0. 92 0. 9 0. 88 0.85 0.83 0.8 0. 77 0. 74
1000
0.93 0.91 0. 89 0.87 0.85 0. 83 0.81 0.78 0.75 0. 72
1500
0.87 0.85 0. 83 0.81 0.79 0. 77 0.75 0.72 0.69 0. 66
2000
0.8 0.79 0.77 0.75 0.73 0.71 0.69 0.66 0.63 0.6
2500
0.74 0.73 0.71 0.7 0.68 0.65 0.63 0.61 0.58 0.55
3000
0.69 0.67 0. 65 0.64 0.62 0.6 0. 58 0.56 0.53 0.5
3500
0.63 0.62 0. 61 0.59 0.57 0. 55 0.53 0.51 0.48 0. 45
4000
0.58 0.57 0. 56 0.54 0.52 0.5 0. 48 0.46 0.44 0.41
TEMPERATURE (Celsius)
HEIGHT (m.)
HUMIDITY BETWEEN 50-100%
K2
8
1. MAIN TECHNICAL SPECIFICATIONS & DATA
1.4.4 Selection of the right power for the generator
To make the right selection of the generator power please note that many
equipments have what is called a pick intensity when start up the machine. For that reason the nomimal power of the equipmet is not the same as the nominal power requiered. Please refer to the table bellow for reference but in any case if you have any doubt tyou can consult with your specialiced partner dealer, or also can contact the manufacturer for any clarification.
table 4
Do not connect any equipment that exceed the values above
mentioned.
1.5 Name identification and name plate
table 5
All products manufactured from ITC Power under license of HYUNDAI
Corporation, include a name plate on the generator set in order to trace the production time and the model.
DHY2500L/E DHY4000L/E DHY4000SE DHY6000L/E/3 DHY6000SE/3
LOAD
MODEL
Home electric appliance, incandescent lamp.
Projector, electric cooker, T.V., bulb, microwave. 1760 W
2640 W
4400 W
Machine with rectifier type motor
Drilling machine, grinding machine
733 W
1100 W
1833 W
Machine with capacitance starting type
Water pump, air compressor.
1100 W
1650 W
2750 W
!
CAUTION
Single phase
Three phase
Luxury frame Silent frame,Electric start
Power output code
Diesel generator
DHY 6000 LE -3
-3
LICENSED BY HYUNDAI CORPORATION, KOREA
IMPORTED BY:
80
50
MODEL / SERIAL
POWER
Rated-Max.
WEIGHT / DIM. DATE
D. M. Y.
kW VOLTAGE V
kg. mm.
Fig.1 Name Plate
Soundproof type
Fig.2 Name Plate
Open type
9
Loading...