Hypercom IN-tact 1101 User Manual

Ethernet CAT5 Daisy Chain Cable Example Using Existing EIA/TIA T568 (A or B) Ethernet Wiring

Note: There is a variable relationship between the total number of terminals that can be supported
and the length of any given cable run. Longer individual runs mean fewer terminals. Likewise, shorter runs mean more terminals. Building wiring will dictate the total number of terminals that can be supported. The maximum length of cabling that can be supported is 4000 ft. Total distance on any run is the sum of the distance to and from the terminal.

Interconnecting Terminal Cables

Copyright 2004 by Hypercom Corporation. All Rights Reserved. Hypercom and the Hypercom logo are registered trademarks of Hypercom Corporation. ICE and IN-tact are trademarks of Hypercom Corporation. 940433-002

IN-tact™ 1101 Cabling Overview

The Hypercom® IN-tact 1101 can be used as an IP gateway device for a directly-connected single terminal or a network of terminals. Because there are a variety of configuration, cables must be ordered and are shipped separately from the IN-tact unit. This brief guide provides cable information for each of the possible IN-tact 1101 configurations and examples of how each cable is used.

Cable List

The following list provides the part number of each cable that can be used with the IN-tact 1101, a description of the cable, and how the cable is used.
Direct Connection T-Series
Cable P/N Description Application/Notes
500401-001 120 ohm Terminating Resistor 120 ohm terminating resistor for the
beginning and end of a daisy chain. Two resistors are required.
810071-001 Standard Ethernet cable
Male RJ-45 to Male RJ-45 10 ft. length (3 meters)
810331-002 Male 9-pin DIN to Male 9-pin
DIN 18 in. length (45.7 cm)
810334-003 Male 9-pin DIN to Male RJ-11
18 in. length (45.7 cm)
810338-001 Male RJ-11 to dual port Female
RJ-11 18 in. length (45.7 cm)
810339-001 Male RJ-11 to Male RJ-11
10 ft. length (3 meters)
810340-001 Male 9-pin DIN to dual port
Female RJ-11 18 in. length (45.7 cm)
810343-001 Male RJ-45 to dual port Female
RJ-11 18 in. length (45.7 cm)
Connect LAN port to router, hub, DSL, or cable modem. (1 for 1, not crossover)
Direct connect IN-tact Por t 2 to I CE™ Series terminal or T7Plus terminal.
Direct connect IN-tact Port 2 to T-Series terminal.
Connect T-Series terminals within daisy chain.
Interconnecting cable for daisy chain. See example on adjoining page.
• Create daisy chain of terminals from IN-tact Port 2
• Connect ICE Series or T7Plus terminals within daisy chain.
Create daisy chain of terminals from Ethernet patch panel utilizing existing EIA/TIA T568 (A or B) Ethernet wiring. See example on back page.
Direct Connection ICE Series
HLAN Daisy Chain Example
810344-001 Male RJ-45 to Male 9-pin DIN
10 ft. length (3 meters)
810345-001 Male RJ-45 to Male RJ-11
10 ft. length (3 meters)
Connect ICE Series or T7Plus terminals to Ethernet wallplate.
Connect T-Series terminals to Ethernet wallplate.