RX16JFT & RX16FT-PS
Flush Mount Lift Rack
SPECIFICATIONS
RX16FT-PS Shown
Site Specications
Substructure Requirements Refer to 6339-T for full details
Power Requirements 208-230 VAC, single phase power, 26 Amp
Air Supply Requirements
Minimum Concrete Spec. 3 in. (76 mm) thick, 3000 PSI (20,700kPA) rating
Maximum Floor Slope 2 in. (51 mm) over 126 in. (3200 mm)
Max. Vehicle Weight 16,000 lbs. (7257 kg)
Max. Wheelbase
General Service 187 in. (4750 mm)
Two-Wheel Alignment 182 in.(4623 mm)
Four-Wheel Alignment 158 in. (4013 mm)
Alignment Height All lock positions
Min. Four-Wheel Alignment 88 in. (2235 mm)
Lifting Speed 1 speed, 60 seconds
Lowering Speed 2 speed, 25 seconds
Jacks require 125 PSI (8.6 bar) for full capacity
Product Specications
90-150 PSI (6.2-10.3 bar)
MODEL FEATURES / DIMENSIONS
Features
9000-lb Swing Air
Jacks (2)
Two-Speed Lowering
W2
JFT FT-PS
R
H1
Outside Width (W1)
Inside Width (W2)
Length (L)
Runway Width (R)
Raised Height (H1)
Depth (H2)
Dimension
92.5 in.
2350 mm
40 in.
1016 mm
231.375 in.
5877 mm
26 in.
660 mm
72 in.
1829 mm
14.75 to 15.25 in.
375 to 387 mm
W1
For lift rack information visit:
www.hunter.com/lift-racks
H2
For general inquiries visit:
www.hunter.com
or call
800-448-6848
L
Continued on Page 2
For local contact visit:
www.hunter.com/contact-hunter
Form 6491-T, 06-15
Supersedes Form 6491-T, 08-13a
Copyright © 2015, Hunter Engineering Company
![](/html/3a/3a66/3a665595fac56556396e46be3672a41ee49f4279d167289ed21a3883968a7f4f/bg2.png)
RX16JFT & RX16FT-PS
!
WARNING
!
WARNING
!
WARNING
!
WARNING
DRAIN
LOCATED
IN
CENTER
OF PIT
SLOPE
PIT
FLOOR
TOWARD
DRAIN
(1/2")
CONSOLE CONDUIT DETAIL
96 1/2"
(2451 mm)
OPTIONAL CONSOLE
LOCATION
16"
(406
mm)
22"
(559 mm)
6" MIN.*
152 mm()
OPTIONAL 1 1/2 IN. DIA. CONDUIT
FOR COMMUNICATION CABLE
TO ALIGNMENT CONSOLE
HAWKEYE SERIES SENSORS
AND PRONTO SYSTEMS HAVE
SPACE REQUIREMENTS IN
FRONT OF LIFT THAT MUST BE
MET, REFER TO APPROPRIATE
SITE REQUIREMENTS.
ENTIRE PIT
(BOTTOM AND WALLS)
MUST BE HARD
TROWEL FINISH
34 3/4"
(883 mm)
EXTENDER
PLATES
51-2464-1-PPP
AND
RAMPS
147-141-1-PPP
231 3/8"
(5877 mm)
64"
(1626 mm)
33 3/4"
(857 mm)
!
WARNING
STAY BEHIND
YELLOW LINE
WHEN THE
LIFT MOVES.
128-978-2
DECAL 128-978-2
PLACED ON EACH
PERIMETER ANGLE
(4 PLACES)
AND EACH SIDE OF
LIFT (2 PLACES)
!
WARNING
APPROX. 2"
(51 mm)
TYPICAL
ANGLE AROUND PIT
PERIMETER
PAINTED SAFETY
YELLOW
(NOT SUPPLIED BY
HUNTER)
32"
(813 mm)
RAMPS
147-141-1-PPP
OPTIONAL REAR STEP
(6" (152 mm) MAX. HT.)
PIT DEPTH OF
14 3/4" to 15 1/4"
(375 mm to 387 mm)
REQUIRED AT
FRONT END OF PIT
OPT. FRONT STEP
(12" (305 mm)
MAX. DEPTH)
45
6" MIN.
RADIUS
CONDUIT
EXIT FLUSH
WITH
PIT FLOOR
ROUTE 4" MIN DIAMETER
CONDUIT OR EQUIVALENT
CLOSED CHANNEL FROM
PIT FLOOR TO BASE OF
CONSOLE
*
LONGER VEHICLES WILL NEED TO BE SERVICED WITH BAY DOOR OPEN. TO
ACCOMMODATE MOST VEHICLES, INCREASE SPACE BEHIND PIT TO () OR
GREATER.
39" 991 mm
** SITES WITH D.R.W. TRUCK
TRAFFIC SHOULD USE 20" MIN.
CONSOLE TO PIT DISTANCE.
**
15" TO 41"
(381 TO 1041 mm)
VEHICLE APPROACH
BAY DOORBAY DOOR
Flush Mount Lift Rack
SPECIFICATIONS (Refer to 6339-T for substructure construction requirements)
*Non-standard positioning of control console is limited to a maximum space between console and rack of 6 feet
(1829 mm) at the approach ramp end and 17 feet (5182 mm) at the turnplate end. Additional threshold and perhaps
hydraulic hoses will be required (refer to Installation Instruction for details).
All dimensions shown are for nished pit. Accomodate tile thickness as needed.
Supersedes Form 6491-T, 08-13a
Form 6491-T, 06-15