![](/html/92/923b/923bcb2e7f22db08662b7bd5dc4d96918f5d9f1d9dd0e0d915e3b73a0bc4bbcc/bg1.png)
RX10FT-IS
Flush Mount Lift Rack
SPECIFICATIONS
RX10FT-IS Shown
Site Specications
Substructure Requirements
Power Requirements
Air Supply Requirements
Minimum Concrete Spec. 3 in. (76 mm) thick, 3000 PSI (20,700 kPA) rating
Maximum Floor Slope 2 in. (51 mm) over 126 in. (3200 mm)
Max. Vehicle Weight 10,000 lbs. (4536 kg)
Max. Wheelbase
General Service 167 in. (4241 mm)
Two-Wheel Alignment 162 in. (4115 mm)
Four-Wheel Alignment 158 in. (4013 mm)
Alignment Height All lock positions
Min. Four-Wheel Alignment 88 in. (2235 mm)
Lifting Speed 55 seconds
Lowering Speed 25 seconds
Jacks require 125 PSI (8.6 bar) for full capacity
Product Specications
Refer to 6198-T for full details
208-230 VAC, single phase power, 26 Amp
90-150 PSI (6.2-10.3 bar)
MODEL FEATURES / DIMENSIONS
Feature
6000-lb Swing Air
Jacks (2)
Two-Speed Lowering
W2 R
FT-IS
H1
Outside Width (W1)
Inside Width (W2)
Length (L)
Runway Width (R)
Raised Height (H1)
Depth (H2)
Dimension
88.5 in.
2248 mm
40 in.
1016 mm
215.375 in.
5471 mm
24 in.
610 mm
72 in.
1829 mm
9.25 to 10.25 in.
235 mm to 260 mm
W1
For lift rack information visit:
www.hunter.com/lift-racks
H2
For general inquiries visit:
www.hunter.com
or call
800-448-6848
L
Continued on Page 2
For local contact visit:
www.hunter.com/contact-hunter
Supersedes Form 6495-T, 12-12a
Copyright © 2015, Hunter Engineering Company
Form 6495-T, 06-15
![](/html/92/923b/923bcb2e7f22db08662b7bd5dc4d96918f5d9f1d9dd0e0d915e3b73a0bc4bbcc/bg2.png)
RX10FT-IS
!
WARNING
!
WARNING
!
WARNING
!
WARNING
DRAIN
LOCATED
IN
CENTER
OF PIT
SLOPE
PIT
FLOOR
TOWARD
DRAIN
(1/2")
CONSOLE CONDUIT DETAIL
92 1/2"
(2350 mm)
!
WARNING
STAY BEHIND
YELLOW LINE
WHEN THE
LIFT MOVES.
128-978-2
DECAL 128-978-2
OPTIONAL CONSOLE LOCATION
(4 places on edging and 2 places on lift)
41 3/8"
(1051 mm)
141 3/4"
(3600 mm)
14"
(356 mm)
APPROX. 2" (51 mm) TYPICAL
14"
(356 mm)
5"
(127 mm)
5"
(127 mm)
14" X 5"
CUTOUT
(4 places)
ANGLE AROUND PIT PERIMETER:
- not around
- painted safety yellow
- not supplied by Hunter
14" X 5" cutouts
16"
(406
mm)
22"
(559 mm)
6" MIN.*
152 mm()
OPTIONAL 1 1/2" DIA. CONDUIT
FOR COMMUNICATION CABLE
TO ALIGNMENT CONSOLE
HAWKEYE SERIES SENSORS
AND PRONTO SYSTEMS HAVE
SPACE REQUIREMENTS IN
FRONT OF LIFT THAT MUST BE
MET, REFER TO APPROPRIATE
SITE REQUIREMENTS.
ENTIRE PIT
(BOTTOM AND WALLS)
MUST BE HARD
TROWEL FINISH
FILLER PLATE
51-2308-1
(4 places)
placed over
14" X 5"
cutout
215 3/8"
(5471 mm)
34 3/4"
(883 mm)
60 1/4"
(1530 mm)
24 1/4"
(616 mm)
EXTENDER
PLATES
51-2464-1-PPP
AND
RAMPS
147-141-1-PPP
RAMPS
147-141-1-PPP
VEHICLE APPROACH
* LONGER VEHICLES WILL NEED TO BE SERVICED WITH BAY DOOR OPEN. TO
ACCOMMODATE MOST VEHICLES, INCREASE SPACE BEHIND PIT TO () OR
GREATER.
39" 991 mm
** SITES WITH D.R.W. TRUCK
TRAFFIC SHOULD USE 20" MIN.
CONSOLE TO PIT DISTANCE.
**
15" TO 41"
(381 TO 1041 mm)
45
6" MIN.
RADIUS
CONDUIT
EXIT FLUSH
WITH
PIT FLOOR
ROUTE 4" MIN DIAMETER
CONDUIT OR EQUIVALENT
CLOSED CHANNEL FROM
PIT FLOOR TO BASE OF
CONSOLE
BAY DOOR
BAY DOOR
Flush Mount Lift Rack
SPECIFICATIONS (Refer to 6198-T for substructure construction requirements)
Dimensions shown are for nished pit. Tile thickness (if applicable) must be considered before pouring pit.
*Non-standard positioning of control console is limited to a maximum space between console and rack of 6 feet
(1829 mm) at the approach ramp end and 18 feet (5486 mm) at the turnplate end. Additional threshold and perhaps
hydraulic hoses will be required (refer to Installation Instruction for details).
Copyright © 2015, Hunter Engineering Company
Supersedes Form 6495-T, 12-12a
Form 6495-T, 06-15