Hubbell 4292P User Manual

Hubbell Industrial Controls, Inc.
Lifting Magnet Controllers
Type 4292P Compact Controller for Scrap Yards
Specication/Price Sheet • August 2008
YARDMASTER PUP
Description
The Type 4292P Yardmaster Pup Controllers incorporate heavy-duty time proven components arranged to provide optimum control of your lifting magnets. A mechanically rugged high thermal capacity discharge varistor assembly is permanently connected in parallel with the magnet and provides a safe discharge path for the stored magnetic energy. With Yardmaster Pup magnetic controllers induced voltage cannot return to the line, permitting rectied power supplies to be used without the added expense of special protective loads or bypass circuits.
Features
Automatic Discharge.• Rated 5-50 amps DC.• Front-Wired, Front-Removable components.• Mechanically interlocked “Lift” and “Drop”• NEMA rated mill duty contactors.• Permanently connected 700V discharge path • completely independent from the line that protects magnet and generator.
High-Thermal capacity varistor discharge path.• Peak magnet induced voltage limited to under 700 • volts. Long electrical contact life.• Minimum maintenance.• Dribble control standard on 115V & 230V controllers.• Ventilated Indoor/Outdoor NEMA 3R Enclosure.
4292P
Application
The Type 4292P Yardmaster Pup Controllers are suited for many uses from light to medium scrap handling applications. They may be used with all types and makes of DC lifting magnets.
Automatic Discharge Type Controllers
The Type 4292P Yardmaster Pup Automatic Discharge Type Lifting Magnet Controllers provide a fast and clean release of magnet loads by applying full voltage reverse current to the magnet. The full voltage reverse current feature permits the operator to promptly return for another lift.
The drop contactor is under the control of the operator’s Master Switch and the Discharge Sensor Module (DSM). When the operator’s Master Switch signals the magnet controller to drop the load, the Lift contactors (L) open. The stored magnet energy is dissipated in the discharge varistor. When the discharge voltage declines to approximately 300V, the DSM energizes the Drop Relay (DR) which in turn enables the Drop Contactor (D) to close applying full voltage reverse current to the magnet and begins the adjustable time reverse current cycle. After completion of the timed reverse current cycle the drop relay and the drop contactor are de-energized.
13.00
14.00
18.50
24.00
15.00
24.00
Ø 0.44 MTG HLS (TYP)
12.50
YARDMASTER PUP
ELEMENTARY SCHEMATIC
FOR 12 or 24 VDC
PUSH BUTTON CONTROL
230 VOLT DC
L L
L
1L
D
10
CFU
4A
600V
3
LIFT
L
300 VOLT DC (MAX)
RECT
MOV
(R2)
DVA
RFU
15A
600V
2
12/24 VOLT DC CONTROL
DROP
4
D
DR
RFU
15A
600V
(M1)
DSM
M
(M2)
75
83
(10) (11)
(12)
(13)
ELEMENTARY SCHEMATIC
FOR 115 or 230 VDC
MASTER SWITCH CONTROL
L L
D
1
RED
WHT
P1
BLK
DR
BLK
L
11
MOV
11
L
D
11
CFU
4A
600V
L ( + )
D2
3
115/125 or 230/250VOLT DC
L
1L
RFU
15A
600V
D
2
4
(P) (L)
(R) (D)
230 VOLT DC
RECT
MOV
(R2)
DVA
115/230 VOLT DC CONTROL
LIFT DROP
M
DR
D
(M1)
(M2)
75
86
RFU
15A
600V
(10) (11)
DSM
(12)
(13)
D
1
RED
WHT
P1
BLK
DR
BLK
L
L ( - )
L
L ( - )
D
DVA.................... Discharge Varistor Assembly
MOV................... Control Suppressor
CFU................... Control Fuse
RFU................... Drop Fuse
RECT./MOV....... Rectier / MOV Assembly
P1...................... Potentiometer Assembly
DR..................... Drop Relay
DSM.................. Discharge Sensor Module
D....................... Drop Contactor
L........................ Lift Contactor
Cabinet Dimensions
Approximate Shipping Weight 100 lbs.
D2.......................
DVA....................
Diode
Discharge Varistor Assembly
MOV................... Control Suppressor
CFU................... Control Fuse
RFU................... Drop Fuse
RECT./MOV....... Rectier / MOV Assembly
P1...................... Potentiometer Assembly
DR..................... Drop Relay
DSM.................. Discharge Sensor Module
D....................... Drop Contactor
L........................ Lift Contactor
Part Numbers and Prices
Part
Number
HC4292001301 24 VDC $4900 HC4292001303 12 VDC $4900 HC4292001305 230 VDC $4900 HC4292001307 115 VDC $4900
HCTA4215
Controller ampacity is based on being used with a 50% duty magnet in a 40º C ambient.
Control Circuit
Voltage
Master Switch for
115/230 VDC Operation
List Price
(Sch. KD)
(Sch. ET)