Hubbell 31.210 User Manual

Hubbell Industrial Controls, Inc.
Compact Locomotive Radio Control System
Hubbell Radio Remote Control Systems
Spec Sheet 31.210 • August 2000 • New
Internal Diagnostics
Receiver Cabinet
Run by microprocessor on internal programs
Run by microprocessor on commands and I/O
Power-up diagnostics
Continuous monitoring
Operational Status Readout
English language display of status
Controls System Features
New Compact receiver with diagnostic display module
New Compact pneumatics interface with analog valves for throttle/brake
For use with any of the Hubbell transmitters, see Catalog 31.300
Compact Receiver
Proven rf module and micro I/O module from radio crane control
New EStop” board
New plug-in output interface cards
Frequency: 7276 or 450470 MHz FM
NEMA 12 enclosure 24” h x 24” w x 12” d
Pneumatics Cabinet
Compact Pneumatic Interface
Very compact manifold/valve assembly
Analog valves for throttle and train-line brake
control
Analog pressure indicators
NEMA 12 enclosure 24” h x 24” w x 12” d
Midsize Transmitter
(See Spec 31.320)
Outline Drawings
Specifcations
BSS/.250;TPI=28/20;CHSD=.261;TDSF=.2130;TDSC=.2010
25.50
24.00
22.50
MANUAL
REMOTE
T
-S +S
-OUT +OUT
MODEL NO.
PT.
SER.
J2J1
WBA4490_ ASSY REV_
VR1
HUBBELL
4301 Cheyenne Drive
Archdale, N.C. 27263
Hubbell Industrial Controls, Inc.
5V
V.
VR2
978654321
J3
12V
ASSY:
REV:
WBA4491
1
345
HUBBELL WBA4516
JMP9
J1
MODULE 1
MODULE 2
+5V
1A
B2
5V COM
R4 JMP1 JMP2 JMP3 JMP4 JMP5 JMP6 JMP7 JMP8
+12V
14
R S
15
GND
1
1
CN2CN1
WBA4528
43A1332313
3424 44A214
2
HUBBELL WBA4516
JMP9
J4
J3J2
MODULE 3 MODULE 4
1A1A 1A
R5
1515S15
WBA4528
WBA4528
43A1332313
3424 44A214
J4
J3J2
J1 +5V
LED1
+12V
LED2
TB1
GND +12V
1
WBA4528
+5V
MODULE 1
MODULE 2
MODULE 3 MODULE 4
LED1
+5V
1A
1A1A 1A
B2
5V COM
+12V
R5
R4
LED2 JMP1 JMP2 JMP3
TB1 JMP4
GND JMP5 JMP6
+12V JMP7 JMP8
1
+12V
14
R
1515S15
S
15
GND
1
1
CN2CN1
WBA4536
WBA4536
WBA4535
43A1332313
43A1332313
43A1332313
43A1332313
3424 44A214
3424 44A214
3424 44A214
3424 44A214
Cast Hinges With Removable Hinge Pins
Shown With Door Removed
Receiver Cabinet Weight 90 lbs.
Pneumatic Cabinet Weight 110 lbs.
24.00
22.50
HUBBELL
MODEL NO.
Hubbell/Industrial Controls, Inc.
4301 Cheyenne Dr.
PT.
Archdale, N.C. 27263
SER.
25.50
24.00
BSS/.250;TPI=28/20;CHSD=.261;TDSF=.2130;TDSC=.2010
Supply Voltage ......................... 12VDC, 24VDC, 36VDC or 72VDC
Internal Power Requirements ........ +11.9–13.1VDC & +4.5–6.5VDC, 24 VDC
Operating Temperature .............. –22°F (–30°C) to 140°F (+60°C)
Alternate Mtg Position
RESET
8.00
Radio Receiver
4.13
Frequency Range ...................... 72–76 MHz or 450–470 MHz
BSS/.250;TPI=28/20;CHSD=.261;TDSF=.2130;TDSC=.2010
Channel Availability .................. as required by user
Frequency Stability .................... ±5 ppm
22.50
24.00
25.50
24.00
WB4520
HUBBELL
BSS/.250;TPI=28/20;CHSD=.261;TDSF=.2130;TDSC=.2010
Sensitivity ................................ 1 µv @ 20 dB quieting
Data Reception ......................... compatible with Hubbell transmitters
Modulation .............................. Manchester II (bi-phase)
Baud Rate ............................... 4800 bps
Message Format ....................... preamble, sync, start flag, address, control, CRC
check code
Control Section
Single board computer consisting of 80C31 controller, 64k EPROM, EPLD containing circuits for bi-phase decoding
DC Output Section (Electro-mechanical relays)
Panel mounted mother-board to accommodate 4 plug-in relay boards, each with 6 output relays, for a maximum of 24 ac output relays and 12 sense inputs
Indicators ........................................... LED on each output
Feedback Sensing ............................... opto-isolated input from: AIR PRESSURE,
THROTTLE, BRAKE, FORWARD, REVERSE
relay outputs
Relays................................................ Standard PC board relays
Output Rating...................................... 115/230V ac, 50/60 Hz, 5A resistive;
C
L
Isolation ............................................. 5000V
12/24V dc, 5A resistive
12.00
BSS/.250;TPI=28/20;CHSD=.261;TDSF=.2130;TDSC=.2010
F14 F15F12 F13
F11
F10F9
F7
F8
F1
F2
BSS/.250;TPI=28/20;CHSD=.261;TDSF=.2130;TDSC=.2010
F5
F6
F4F3
HUBBELL
Hubbell Industrial Controls, Inc.
a subsidiary of Hubbell Incorporated
JPS-100-1M © 2000
Printed in U.S.A.
MODEL NO.
HUBBELL
Hubbell Industrial Controls, Inc.
4301 Cheyenne Drive
PT.
Archdale, N.C. 27263
SER.
V.
Right Side View Of Cabinet W/door Closed
50 Edwards Street Madison, Ohio 44057 (440) 428-1161 Fax (440) 428-7635
4301 Cheyenne Drive Archdale, NC 27263 (336) 434-2800 Fax (336) 434-2801
DC Output Section (Stepped analog outputs)
Panel mounted mother-board to accommodate 4 plug-in boards, each with 1 analog output.
Indicators ........................................... LED on each of 8 levels
Output Rating ...................................... 0–10V dc, 20mA, in 8 steps
Isolation ............................................. 5000V
“E-Stop” Board
Plug-in PC board (plugs into motherboard of DC Output Section in place of 1 electro­mechanical relay board)
Indicators ........................................... LED on each of 5 inputs and 1 output
Inputs ................................................ 5 inputs, optically isolated
Isolation ............................................. 5000V
Control Relays (DIN Rail Mounted)
Individual control relays, as required for locomotive functions.
NEMA P300 DC Inductive Rating .......... 5A Continuous at 250VDC Max.
138VA Make & Break Max.
http://www.hubbell-icd.com/radiocontrols/
Hubbell Industrial Control Solutions
Loading...