Huawei RRU3276 Users Guide

DBS3900 LTE TDD V600R007C00

RRU3276 Installation Guide

Issue

Draft A

Date 2015-10-30

HUAWEI TECHNOLOGIES CO., LTD.

Copyright © Huawei Technologies Co., Ltd. 2015. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.

All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice

The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.

Address: Huawei Industrial Base

Bantian, Longgang

Shenzhen 518129

People's Republic of China

Website: http://www.huawei.com

Email: support@huawei.com

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

i

Copyright © Huawei Technologies Co., Ltd.

 

 

DBS3900 LTE TDD RRU3252/RRU3256 Installation

 

Guide

About This Document

About This Document

Purpose

This document describes the process of installing a DC RRU3276 (referred to as RRU in this document).

Product Version

The following table lists the product version related to this document.

Product Name

Product Version

 

 

eRelay DBS3900

V100R003C00 and later versions

 

 

Intended Audience

This document is intended for:

Base station installation engineers

Organization

1 Change History

This chapter describes changes in the RRU3276 Installation Guide.

2 Installation Preparations

This chapter describes the reference documents, tools, and instruments that must be ready before the installation. In addition, it specifies the skills that installation engineers must have.

3 Information About the Installation

Before installing an RRU, you must be familiar with its exterior, ports, installation options, physical supports, and installation clearance requirements.

4 Unpacking the Equipment

This chapter describes how to unpack and check the delivered equipment to ensure that all the materials are included and intact.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

ii

 

Copyright © Huawei Technologies Co., Ltd.

 

DBS3900 LTE TDD RRU3252/RRU3256 Installation

 

Guide

About This Document

5 Installation Process

The installation process involves installing an RRU and RRU cables, checking the RRU hardware installation, and powering on the RRU.

6 Hoisting the RRU and Cables onto a Tower

This section describes how to hoist the RRU and Cables onto a tower and provides important notes about the installation.

7 Installing the RRU

This chapter describes the procedure for installing the RRU. The RRU can be installed on a pole, U-steel, angle steel, or wall as required.

8 Installing RRU Cables

This chapter describes the procedure for installing RRU cables.

9 Checking the RRU Hardware Installation

This section describes how to check RRU hardware installation after the installation is complete.

10 Powering On an RRU

This section describes how to check the power-on status of an RRU after all the devices are installed.

11 Appendix

This section describes the procedure for adding an easy power receptacle (pressfit type) connector.

Conventions

Symbol Conventions

The symbols that may be found in this document are defined as follows.

 

Symbol

 

Description

 

 

 

 

 

 

 

 

 

 

 

Indicates a hazard with a high level of risk that, if not avoided,

 

 

 

 

will result in death or serious injury.

 

 

 

 

 

 

 

 

 

 

Indicates a hazard with a medium or low level of risk which, if

 

 

 

 

not avoided, could result in minor or moderate injury.

 

 

 

 

 

 

 

 

 

 

Indicates a potentially hazardous situation that, if not avoided,

 

 

 

 

could cause equipment damage, data loss, and performance

 

 

 

 

 

degradation, or unexpected results.

 

 

 

 

 

 

 

 

 

 

Indicates a tip that may help you solve a problem or save time.

 

 

 

 

 

 

 

 

 

 

Provides additional information to emphasize or supplement

 

 

 

 

 

important points of the main text.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

iii

 

 

Copyright © Huawei Technologies Co., Ltd.

 

 

DBS3900 LTE TDD RRU3252/RRU3256 Installation

 

Guide

About This Document

General Conventions

Convention

Description

 

 

Times New Roman

Normal paragraphs are in Times New Roman.

 

 

Boldface

Names of files, directories, folders, and users are in

 

boldface. For example, log in as user root.

 

 

Italic

Book titles are in italics.

 

 

Courier New

Terminal display is in Courier New.

 

 

Command Conventions

Convention

Description

 

 

Boldface

The keywords of a command line are in boldface.

 

 

Italic

Command arguments are in italics.

 

 

[ ]

Items (keywords or arguments) in square brackets [ ] are

 

optional.

 

 

{ x | y | ... }

Alternative items are grouped in braces and separated by

 

vertical bars. One is selected.

 

 

[ x | y | ... ]

Optional alternative items are grouped in square brackets

 

and separated by vertical bars. One or none is selected.

 

 

{ x | y | ... } *

Alternative items are grouped in braces and separated by

 

vertical bars. A minimum of one or a maximum of all can

 

be selected.

 

 

GUI Conventions

Convention

Description

 

 

Boldface

Buttons, menus, parameters, tabs, windows, and dialog titles

 

are in boldface. For example, click OK.

 

 

>

Multi-level menus are in boldface and separated by the ">"

 

signs. For example, choose File > Create > Folder.

 

 

Keyboard Operation

 

Format

 

Description

 

 

 

 

 

 

 

 

 

Key

 

Press the key. For example, press Enter and press Tab.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

iv

 

 

Copyright © Huawei Technologies Co., Ltd.

 

 

DBS3900 LTE TDD RRU3252/RRU3256 Installation

 

Guide

About This Document

 

 

 

 

 

Format

 

Description

 

 

 

 

 

Key 1+Key 2

 

Press the keys concurrently. For example, pressing

 

 

 

Ctrl+Alt+A means the three keys should be pressed

 

 

 

concurrently.

 

 

 

 

 

Key 1, Key 2

 

Press the keys in turn. For example, pressing Alt, A means

 

 

 

the two keys should be pressed in turn.

 

 

 

 

Mouse Operation

Action

Description

 

 

Click

Select and release the primary mouse button without

 

moving the pointer.

 

 

Double-click

Press the primary mouse button twice continuously and

 

quickly without moving the pointer.

 

 

Drag

Press and hold the primary mouse button and move the

 

pointer to a certain position.

 

 

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

v

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

Contents

Contents

About This Document....................................................................................................................

 

ii

1 Change History..............................................................................................................................

 

1

2 Installation Preparations .............................................................................................................

 

2

2.1

Reference Documents ......................................................................................................................................

 

2

2.2 Tools and Instruments ......................................................................................................................................

 

2

2.3

Skills and Requirements for Onsite Personnel .................................................................................................

4

3 Information About the Installation ...........................................................................................

5

3.1

RRU Exterior ...................................................................................................................................................

 

5

3.2

RRU Ports ........................................................................................................................................................

 

6

3.3

RRU Indicators.................................................................................................................................................

 

8

3.4

Installation Options ........................................................................................................................................

 

10

3.5

Installation Clearance Requirements of an RRU............................................................................................

15

 

3.5.1 Clearance for a Single RRU ..................................................................................................................

15

 

3.5.2 Clearance for Multiple RRUs................................................................................................................

17

 

3.5.3 Spacing Between RRUs ........................................................................................................................

 

20

4 Unpacking the Equipment ........................................................................................................

 

23

5 Installation Process .....................................................................................................................

 

25

6 Hoisting the RRU and Cables onto a Tower..........................................................................

26

6.1

Installing an RRU on a Tower ........................................................................................................................

 

26

6.2

Hoisting Fiber Optic Cables onto a Tower .....................................................................................................

30

6.3

Hoisting Power Cables onto a Tower .............................................................................................................

33

7 Installing the RRU ......................................................................................................................

 

37

7.1

Mounting Kits for an RRU .............................................................................................................................

 

38

7.2

Installing the RRU on a Pole..........................................................................................................................

 

38

 

7.2.1 Installing a Single RRU ........................................................................................................................

 

43

 

7.2.2 Installing Two RRUs.............................................................................................................................

 

46

 

7.2.3 Installing Multiple RRUs ......................................................................................................................

48

7.3

Installing the RRU on U-Steel........................................................................................................................

 

53

7.4

Installing the RRU on Angle Steel .................................................................................................................

57

7.5

Installing the RRU on a Wall..........................................................................................................................

 

60

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

vi

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

Contents

8 Installing RRU Cables................................................................................................................

65

8.1

Cabling Requirements ....................................................................................................................................

66

8.2

Cable Connections .........................................................................................................................................

72

8.3

Installation Process.........................................................................................................................................

76

8.4

RRU Cable List ..............................................................................................................................................

77

8.5

Installing an RRU PGND Cable.....................................................................................................................

79

8.6

Installing an RRU RF Jumper ........................................................................................................................

80

8.7

Installing an RRU Alarm Cable......................................................................................................................

83

8.8

Installing an RRU AISG Multi-Wire Cable and an RRU AISG Extension Cable..........................................

84

8.9

Opening the Cover Plate of an RRU Cabling Cavity .....................................................................................

87

8.10 Installing an RRU Power Cable ...................................................................................................................

89

8.11 Installing an Optical Fiber Cable..................................................................................................................

90

8.12 Closing the Cover Plate of an RRU Cabling Cavity ....................................................................................

92

9 Checking the RRU Hardware Installation .............................................................................

95

10 Powering On an RRU ...............................................................................................................

96

11 Appendix ....................................................................................................................................

98

11.1 Adding an Easy Power Receptacle (Pressfit Type) Connector to an RRU Power Cable ..............................

98

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

vii

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

1 Change History

1 Change History

This chapter describes changes in the RRU3276 Installation Guide.

Draft A (2015-10-30)

This is a draft.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

1

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

2 Installation Preparations

2 Installation Preparations

About This Chapter

This chapter describes the reference documents, tools, and instruments that must be ready before the installation. In addition, it specifies the skills that installation engineers must have.

2.1 Reference Documents

Before the installation, you must be familiar with reference documents.

2.2 Tools and Instruments

All tools and instruments required for RRU installation must be ready before the installation.

2.3 Skills and Requirements for Onsite Personnel

Onsite personnel must be qualified and trained. Before performing any operation, onsite personnel must be familiar with correct operation methods and safety precautions.

2.1 Reference Documents

Before the installation, you must be familiar with reference documents.

The following reference documents are required during RRU installation:

RRU3276 Hardware Description

DBS3900 Installation Guide

OCB-01M User Guide

This document describes the RRU installation on a pole, U-steel, angle steel, or wall. If RRUs are installed on the IFS06, the following reference document is required:

DBS3900 (ICR) Installation Guide

2.2Tools and Instruments

All tools and instruments required for RRU installation must be ready before the installation.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

2

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

2 Installation Preparations

 

 

 

 

 

Hammer drill (φ 12 bit to φ

Electrostatic discharge

Vacuum cleaner

 

14 bit)

 

(ESD) gloves

 

 

 

 

 

 

 

Heat gun

 

Phillips screwdriver (M3 to

Flat-head screwdriver (M3 to

 

 

 

M6)

M6)

 

 

 

 

 

 

Rubber mallet

 

Hydraulic pliers

Wire stripper

 

 

 

 

 

 

Utility knife

 

Cable cutter

Level

 

 

 

 

 

Adjustable wrench (capacity

Torque screwdriver

Torque socket

 

≥ 32 mm)

 

 

 

 

Torque wrench

5 mm

 

 

 

 

 

 

Capacity: 17 mm, 21 mm,

(M3 to M6)

 

 

and 32 mm

 

 

 

 

 

 

 

Combination wrench

 

 

 

 

 

(M3 to M6)

 

 

Capacity: 17 mm, 21 mm,

 

 

 

and 32 mm

 

 

 

 

 

 

 

 

 

Multimeter

 

Marker (diameter ≤ 10 mm)

Measuring tape

 

 

 

 

 

 

 

 

 

 

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

3

 

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

2 Installation Preparations

2.3 Skills and Requirements for Onsite Personnel

Onsite personnel must be qualified and trained. Before performing any operation, onsite personnel must be familiar with correct operation methods and safety precautions.

Before the installation, pay attention to the following items:

The customer's technical engineers must be trained by Huawei and be familiar with the proper installation and operation methods.

The number of onsite personnel depends on the engineering schedule and installation environment. Generally, only three to five onsite personnel are necessary.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

4

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

3 Information About the Installation

About This Chapter

Before installing an RRU, you must be familiar with its exterior, ports, installation options, physical supports, and installation clearance requirements.

3.1 RRU Exterior

This section describes the exterior and dimensions of an RRU.

3.2 RRU Ports

This section describes ports on the RRU panels. An RRU has a bottom panel, cabling cavity panel, and indicator panel.

3.3 RRU Indicators

This section describes six indicators on an RRU. They indicate the running status.

3.4 Installation Options

This section describes RRU installation options. An RRU can be installed on a pole, U-steel, angle steel, or wall.

3.5 Installation Clearance Requirements of an RRU

This section describes the requirements for the installation clearance of a single RRU and multiple RRUs and the requirements for the installation spacing between RRUs.

3.1 RRU Exterior

This section describes the exterior and dimensions of an RRU.

Figure 3-1 shows an RRU.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

5

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Figure 3-1 RRU exterior

Figure 3-2 shows RRU dimensions.

Figure 3-2 RRU dimensions

3.2 RRU Ports

This section describes ports on the RRU panels. An RRU has a bottom panel, cabling cavity panel, and indicator panel.

Figure 3-3 shows the ports on the RRU panels.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

6

 

Copyright © Huawei Technologies Co., Ltd.

 

Huawei RRU3276 Users Guide

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Figure 3-3 Ports on the RRU panels

Table 3-1 describes ports and indicators on the RRU panels.

Table 3-1 Ports and indicators on the RRU panels

 

Item

 

Label

Description

 

 

 

 

 

 

 

 

(1) Ports at the

 

ANT0-ANT3

TX/RX ports. ANT0 port supports RET

 

 

bottom

 

 

signal transmission.

 

 

 

 

 

 

 

 

 

RET/EXT_ALM

Communication port for the RET antenna or

 

 

 

 

port for alarm reporting, supporting RET

 

 

 

 

 

signal transmission

 

 

 

 

 

 

 

 

 

 

 

 

 

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

7

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

 

 

 

 

 

 

 

 

Item

 

Label

Description

 

 

 

 

 

 

 

 

 

 

RGPS

RGPS port, which is optional.

 

 

 

 

 

 

 

 

(2) Ports in the

 

CPRI0/IR0

Optical port

 

 

cabling cavity

 

 

 

 

 

 

CPRI1/IR1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RTN(+)

Power supply socket

 

 

 

 

 

 

 

 

 

 

NEG(-)

 

 

 

 

 

 

 

 

 

(3) Indicators

 

RUN

For details, see 3.3 RRU Indicators.

 

 

 

 

 

 

 

 

 

 

ALM

 

 

 

 

 

 

 

 

 

 

 

ACT

 

 

 

 

 

 

 

 

 

 

 

VSWR

 

 

 

 

 

 

 

 

 

 

 

CPRI0/IR0

 

 

 

 

 

 

 

 

 

 

 

CPRI1/IR1

 

 

 

 

 

 

 

If only two RF ports are required, ANT0 and ANT1 are used by default.

The RET ports to be used are determined by the software configuration.

3.3 RRU Indicators

This section describes six indicators on an RRU. They indicate the running status.

For the specific positions of RRU indicators, see 3.2 RRU Ports.

Table 3-2 describes RRU indicators.

Table 3-2 Indicators on the RRU

 

Label

Color

Status

Description

 

 

 

 

 

 

RUN

Green

Steady on

There is power supply, but the

 

 

 

 

module is faulty.

 

 

 

 

 

 

 

 

Steady off

There is no power supply, or the

 

 

 

 

module is faulty.

 

 

 

 

 

 

 

 

Blinking on for 1s and off

The module is working properly.

 

 

 

for 1s

 

 

 

 

 

 

 

 

 

Blinking on for 0.125s

Software is being loaded to the

 

 

 

and off for 0.125s

module, or the module is not started.

 

 

 

 

 

 

ALM

Red

Steady on

Alarms are generated, and the

 

 

 

 

module must be replaced.

 

 

 

 

 

 

 

 

Steady off

No alarm is generated.

 

 

 

 

 

 

 

 

 

 

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

8

Copyright © Huawei Technologies Co., Ltd.

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

 

 

 

 

 

 

Label

Color

Status

Description

 

 

 

 

 

 

 

 

Blinking on for 1s and off

Alarms are generated. The alarms

 

 

 

for 1s

may be caused by the faults on the

 

 

 

 

related modules or ports. Therefore,

 

 

 

 

the necessity for module

 

 

 

 

replacement is uncertain.

 

 

 

 

 

 

ACT

Green

Steady on

The module is working properly

 

 

 

 

with TX channels enabled or

 

 

 

 

software is being loaded without

 

 

 

 

RRU running.

 

 

 

 

 

 

 

 

Blinking on for 1s and off

The module is working properly

 

 

 

for 1s

with TX channels disabled.

 

 

 

 

 

 

VSWR

Red

Steady off

No VSWR alarm is generated.

 

 

 

 

 

 

 

 

Steady on

A VSWR alarm is generated.

 

 

 

 

 

 

CPRI0/I

Red or

Steady green

The CPRI link is functioning

 

R0

green

 

properly.

 

 

 

 

 

 

 

 

Steady red

An optical module fails to transmit

 

 

 

 

or receive signals possibly because

 

 

 

 

the optical module is faulty or the

 

 

 

 

optical fiber cable is broken.

 

 

 

 

 

 

 

 

Blinking red on for 1s and

The CPRI link is out of lock

 

 

 

off for 1s

possibly because of mutual lock of

 

 

 

 

dual-mode clock sources or

 

 

 

 

mismatched data rates over CPRI

 

 

 

 

ports. (You are advised to check the

 

 

 

 

system configuration to rectify the

 

 

 

 

fault.)

 

 

 

 

 

 

 

 

Steady off

The SFP module is not properly

 

 

 

 

installed, or the optical module is

 

 

 

 

powered off.

 

 

 

 

 

 

CPRI1/I

Red or

Steady green

The CPRI link is functioning

 

R1

green

 

properly.

 

 

 

 

 

 

 

 

Steady red

An optical module fails to transmit

 

 

 

 

or receive signals possibly because

 

 

 

 

the optical module is faulty or the

 

 

 

 

optical fiber cable is broken.

 

 

 

 

 

 

 

 

Blinking red on for 1s and

The CPRI link is out of lock

 

 

 

off for 1s

possibly because of mutual lock of

 

 

 

 

dual-mode clock sources or

 

 

 

 

mismatched data rates over CPRI

 

 

 

 

ports. (You are advised to check the

 

 

 

 

system configuration to rectify the

 

 

 

 

fault.)

 

 

 

 

 

 

 

 

Steady off

The SFP module is not properly

 

 

 

 

installed, or the optical module is

 

 

 

 

 

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

9

Copyright © Huawei Technologies Co., Ltd.

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

 

 

 

 

 

 

Label

Color

Status

Description

 

 

 

 

 

 

 

 

 

powered off.

 

 

 

 

 

3.4 Installation Options

This section describes RRU installation options. An RRU can be installed on a pole, U-steel, angle steel, or wall.

Installing an RRU on a Pole

Figure 3-4 shows the diameter of a metal pole for installing an RRU.

Figure 3-4 Diameter of a pole

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

10

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

 

 

 

The diameter of a pole for installing an RRU ranges from 60 mm to 114 mm (2.36 in. to 4.49 in.). The recommended diameter is 80 mm (3.15 in.).

If the diameter of a pole ranges from 60 mm to 76 mm (2.36 in. to 2.99 in.), a maximum of three RRUs can be installed on the pole and the side-mounted installation must not be adopted.

If three or more RRUs must be installed on a pole in centralized mode, the diameter of the pole must range from 76 mm to 114 mm (2.99 in. to 4.49 in.).

The recommended pole thickness is 3.5 mm (0.14 in.) or thicker.

The angle between the vertical plane and the pole, angle steel, or U-steel must be smaller than or equal to 10°, as shown in Figure 3-5.

Figure 3-5 Requirement of the angle between the ground and the pole, angle steel, or U-steel

(1) RRU (2) Pole, angle steel, or U-steel

Figure 3-6 shows an RRU installed on a pole.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

11

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Figure 3-6 RRU installed on a pole

Installing an RRU on U-steel

It is recommended that only one RRU be installed on U-steel.

Figure 3-7 shows U-steel specifications.

Figure 3-7 U-steel specifications

Figure 3-8 shows an RRU installed on U-steel.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

12

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Figure 3-8 RRU installed on U-steel

Installing an RRU on Angle Steel

Figure 3-9 shows angle steel specifications.

Figure 3-9 Angle steel specifications

It is recommended that only one RRU be installed on angle steel.

Figure 3-10 shows an RRU installed on angle steel.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

13

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Figure 3-10 RRU installed on angle steel

Installing an RRU on a Wall

The wall on which RRUs are installed must meet the following requirements:

When a single RRU is installed, the wall has a capacity of bearing at least four times the weight of the RRU.

Expansion bolts must be tightened with a torque of 30 N·m (265.52 lbf·in.) to ensure the bolts work properly and the wall remains intact without cracks in it.

Figure 3-11 shows an RRU installed on a wall.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

14

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Figure 3-11 RRU installed on a wall

3.5 Installation Clearance Requirements of an RRU

This section describes the requirements for the installation clearance of a single RRU and multiple RRUs and the requirements for the installation spacing between RRUs.

The recommended installation clearance ensures normal running and provides an appropriate space for OM. If there is sufficient space, leave the recommended installation clearance.

The minimum installation clearance ensures normal running and heat dissipation, but OM activities such as checking indicator status and opening the maintenance cavity cannot be properly conducted. If the installation space is restricted, leave the minimum installation clearance.

3.5.1 Clearance for a Single RRU

This section describes the recommended and minimum clearance for a single RRU.

Recommended Clearance for a Single RRU

Figure 3-12 shows the recommended clearance for a single RRU.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

15

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Figure 3-12 Recommended clearance for a single RRU

Minimum Clearance for a Single RRU

Figure 3-13 shows the minimum clearance for a single RRU.

Figure 3-13 Minimum clearance for a single RRU

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

16

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Minimum Clearance for a Single RRU Installed on a Tower

Figure 3-14 shows the minimum clearance for a single RRU installed on a tower.

Figure 3-14 Minimum clearance for a single RRU installed on a tower

3.5.2 Clearance for Multiple RRUs

This section describes the recommended and minimum clearance for multiple RRUs.

Recommended Clearance for Multiple RRUs Installed in Centralized Mode

Figure 3-15 shows the recommended clearance for multiple RRUs installed in centralized mode.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

17

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Figure 3-15 Recommended clearance for multiple RRUs installed in centralized mode

Minimum Clearance for Multiple RRUs Installed in Centralized Mode

Figure 3-16 shows the minimum clearance for multiple RRUs installed in centralized mode.

Figure 3-16 Minimum clearance for multiple RRUs installed in centralized mode

Recommended clearance for multiple RRUs installed on a wall in standard mode

Figure 3-17 shows the recommended clearance for multiple RRUs installed on a wall in standard mode.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

18

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Figure 3-17 Recommended clearance for multiple RRUs installed on a wall in standard mode

Minimum clearance for multiple RRUs installed on a wall in standard mode

Figure 3-18 shows the minimum clearance for multiple RRUs installed on a wall in standard mode.

Figure 3-18 Minimum clearance for multiple RRUs installed on a wall in standard mode

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

19

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Recommended Clearance for Multiple RRUs Side-Mounted on a Wall

Figure 3-19 shows the recommended clearance for multiple RRUs side-mounted on a wall.

Figure 3-19 Recommended clearance for multiple RRUs side-mounted on a wall

3.5.3 Spacing Between RRUs

This section describes the horizontal and vertical installation spacing between RRUs.

Recommended horizontal spacing between RRUs

Figure 3-20 shows the recommended horizontal spacing between RRUs.

Figure 3-20 Recommended horizontal spacing between RRUs

Minimum horizontal spacing between RRUs

Figure 3-21 shows the minimum horizontal spacing between RRUs.

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

20

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Figure 3-21 Minimum horizontal spacing between RRUs

Recommended vertical spacing between RRUs

Figure 3-22 shows the recommended vertical spacing between RRUs.

Figure 3-22 Recommended vertical spacing between RRUs

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

21

 

Copyright © Huawei Technologies Co., Ltd.

 

eRelay DBS3900 RRU3252/RRU3256 Installation Guide

3 Information About the Installation

Minimum vertical spacing between RRUs

Figure 3-23 shows the minimum vertical spacing between RRUs.

Figure 3-23 Minimum vertical spacing between RRUs

Issue Draft A (2012-11-30)

Huawei Proprietary and Confidential

22

 

Copyright © Huawei Technologies Co., Ltd.

 