Huawei ODU3601C-1900 Users Manual

User Manual
BTS Maintenance
iSiteC ODU3601C CDMA Soft Base Station
Appendix A Module Maintenance Window
Appendix A Module Maintenance Window
A.1 MTRM
I. Indicators in the maintenance window
Table A-1 Indicators in the maintenance window of MTRM
Indicator
RUN Green 
ALM Red 
ACT Green 
Color
Meaning
Status indicator 
Alarm indicator 
Operation indicator 
Fast flash (4Hz): MTRM is started or software downloading is in progress Slow flash (0.5Hz): BTRM is working normally. Other: Board error Fast flash (4Hz): Critical alarm Slow flash (0.5Hz): Major alarm Slow flash (0.25Hz): Minor alarm Off: No alarm  On: BTRM is working normally and the clock is locked. Slow flash (0.25Hz): Alarm on monitor link Slow flash (0. 5Hz): The clock has not been locked yet or can not be locked.
Description
Normal status
Slow flash (0.5Hz)
Off 
On 
II. Interfaces in the maintenance window
Table A-2 Interfaces in the maintenance window
Interface Function
10M 10MHz signal interface COM Serial communication interface for internal test RST Reset button TRX_ID An 4-digit DIP switch PP2S 2-second signal interface HPA_TEST Test button used for forward local RF transmission LOAD Jumper used for internal test
A-1 
User Manual
BTS Maintenance
iSiteC ODU3601C CDMA Soft Base Station
Table A-3 TRX_ID DIP switch
Appendix A Module Maintenance Window
4 3 2 1 This bit is invalid,
and the default status is off
&
When the ODU3601C is cascaded to the BTS3601C, the. MTRM No. of ODU3601C of level 1 is 1, and the. MTRM No. of ODU3601C of level 2 is 2, and the rest may be deduced by analogy. When the ODU3601C is cascaded to the cBTS3612, the. MTRM No. of ODU3601C of level 1 is 0, and
the. MTRM No. of ODU3601C of level 2 is 1, and the rest may be deduced by analogy.
A.2 MPAM
Note:
DIP switch No.
ON (0) ON (0) ON (0) 0 ON (0) ON (0) OFF (1) 1 ON (0) OFF (1) ON (0) 2 ON (0) OFF (1) OFF (1) 3 OFF (1) ON (0) ON (0) 4 OFF (1) ON (0) OFF (1) 5 OFF (1) OFF (1) ON (0) 6
MTRM No.
No maintenance window installed.
A.3 MFEM
No indicators are installed for MFEM. The interfaces in the window are described in the following table.
Table A-4 Interfaces in the maintenance window of MFEM
TX_TST Used for coupling test of output power ( degree of coupling: -30±1dB) RXM_TST Used for coupling test of main received signals RXD_TST Used for coupling test of diversity received signals
A.4 MAPM
The maintenance window of MAPM is shown in Figure A-1.
Interface Function
A-2 