User Manual
iSiteC ODU3601C CDMA Soft Base Station
Appendix A Module Maintenance Window
For the water-proof purpose, each module maintenance window is installed with a
seal cover. Indicators and interfaces inside are invisible unless this cover is opened.
Appendix A Module Maintenance Window
A.1 MTRM
I. Indicators in the maintenance window
Table A-1 Indicators in the maintenance window of MTRM
Indicator
RUN Green
ALM Red
ACT Green
Color
Meaning
Status
indicator
Alarm
indicator
Operation
indicator
Fast flash (4Hz): MTRM is started or
software downloading is in progress
Slow flash (0.5Hz): BTRM is working
normally.
Other: Board error
Fast flash (4Hz): Critical alarm
Slow flash (0.5Hz): Major alarm
Slow flash (0.25Hz): Minor alarm
Off: No alarm
On: BTRM is working normally and
the clock is locked.
Slow flash (0.25Hz): Alarm on monitor
link
Slow flash (0. 5Hz): The clock has not
been locked yet or can not be locked.
Description
Normal status
Slow flash (0.5Hz)
Off
On
II. Interfaces in the maintenance window
Table A-2 Interfaces in the maintenance window
Interface Function
10M 10MHz signal interface
COM Serial communication interface for internal test
RST Reset button
TRX_ID An 4-digit DIP switch
PP2S 2-second signal interface
HPA_TEST Test button used for forward local RF transmission
LOAD Jumper used for internal test
A-1
User Manual
iSiteC ODU3601C CDMA Soft Base Station
Table A-3 TRX_ID DIP switch
Appendix A Module Maintenance Window
4 3 2 1
This bit is invalid,
and the default
status is off
&
When the ODU3601C is cascaded to the BTS3601C, the. MTRM No. of ODU3601C of level 1 is 1, and
the. MTRM No. of ODU3601C of level 2 is 2, and the rest may be deduced by analogy.
When the ODU3601C is cascaded to the cBTS3612, the. MTRM No. of ODU3601C of level 1 is 0, and
the. MTRM No. of ODU3601C of level 2 is 1, and the rest may be deduced by analogy.
A.2 MPAM
Note:
DIP switch No.
ON (0) ON (0) ON (0) 0
ON (0) ON (0) OFF (1) 1
ON (0) OFF (1) ON (0) 2
ON (0) OFF (1) OFF (1) 3
OFF (1) ON (0) ON (0) 4
OFF (1) ON (0) OFF (1) 5
OFF (1) OFF (1) ON (0) 6
MTRM No.
No maintenance window installed.
A.3 MFEM
No indicators are installed for MFEM. The interfaces in the window are described in
the following table.
Table A-4 Interfaces in the maintenance window of MFEM
TX_TST Used for coupling test of output power ( degree of coupling: -30±1dB)
RXM_TST Used for coupling test of main received signals
RXD_TST Used for coupling test of diversity received signals
A.4 MAPM
The maintenance window of MAPM is shown in Figure A-1.
Interface Function
A-2