Huawei H3CSOHOWDR814G, H3CSOHOWDR834G User Manual

 

DWG Series ADSL2+ Router Quick

 

 

 

 

Installation Manual

ADSL2+

 

Telephone port

1

Appearance

 

LINE

 

 

 

 

 

 

 

 

 

Splitter

 

 

 

ADSL

PHONE

 

 

Desktop PC

NoteBook

 

 

 

 

 

Telephone

 

Figure 1 DWG series rear view

Figure 2 Installing ADSL Line

 

 

 

 

 

2 Packing List

One DWG series ADSL2+ router

One power adapter

One telephone cable

One Ethernet cable

One USB cable

Two screws and two anchors

One Quick Installation Manual

One CD

Certificate of Quality

Two options are available for ADSL line connections:

Direct connect the ADSL line (same as a regular telephone port) to the wall telephone line outlet.

As shown in Figure 2 , Connect the ADSL port and a telephone set to a splitter, and then the splitter to the wall outlet of telephone line. Thus you may place phone calls when accessing the Internet.

3.2 Connecting to PC or Ethernet

You can use crossover or straight through cables to connect the PC, HUB, or switch to the MDI/MDIX auto-sensing interface of WDR series ADSL2+ router.

3

Hardware Installation

3.3 Connecting the Power Cord

3.1

Installing ADSL Line

(1) Attach one end of the power cord to the router and the other end to power

outlet. The power cord is accessory of the router.

(2) Observe the LED status one minute later. The following table lists the LEDs and their normal expected status.

Table 1 LEDs

LED

Normal status

Power

The LED stays green. Check the power cord connection if the LED stays off.

Link

The blinking of the LED indicates the ADSL activation and 20 to 30 seconds later,

 

the LED stays green.

LAN

The green LED stays on. The blinking of the green LED indicates the data

 

transmission on the Ethernet port.

Diag

This LED is off. If this LED turns on, contact the agents for help.

3.4 Configuring to Obtain an IP Address Automatically

Take the operation in the Windows 2000/XP operating system for example. The steps are as follows:

(1)Click the <Start> button and choose the Settings > Control Panel options. Double-click on the Network Dial-up Connections icon from the Control Panel window.

(2)Right-click on the Local Area Connection icon and select the Properties from the pop-up menu. Next, choose the Internet Protocol (TCP/IP) from the Local Area Connection Properties tabbed interface and click <Properties> to proceed.

(3)When the Internet Protocol (TCP/IP) Properties interface pops up, select the Obtain an IP address automatically and Obtain DNS server address automatically options, then click <OK>.

3.5Logon

(1)Check the configuration of the proxy server. Disable the proxy server first when the PC is accessing the Internet through proxy server.

(2)Use the Web browser. Enter http://192.168.1.1 in the address bar (by default, the IP address of the WDR ADSL2+ router is 192.168.1.1).

(3)Log onto the Web setup manager. A new window appears prompting you to enter the user name and password. For the first logon, use the default administrator user name admin with the password admin. The password can be modified after entering the management interface.

Huawei H3CSOHOWDR814G, H3CSOHOWDR834G User Manual

Figure 3 Entering the user name and password

4 Setup

After you log onto the Web page, follow the simple steps to finish the quick configuration:

(1) Click <Quick Start> from the Navigation bar to the Quick Start window. Select the PPPoE as the login type, and then input the user name and password assigned by ISP. You may leave the Service Name box untouched. Then click <Save Settings> to proceed.

Figure 4 Setting parameters

(2) Click <Status> from the Navigation bar to enter the Status tabbed page. You can find that the IP Address item presents an IP address of the public network instead of the original 0.0.0.0.

Figure 5 Checking status

(3) If you obtain no public IP address, click <WAN Setup> from the Navigation bar. Then you can view the VPI/VCI value that the system detects automatically. If the values are incorrect, select the Disable option and input the values manually. For the correct VPI/VCI value, contact your local ISP.

Figure 6 Checking the VPI/VCI value

At last, click <Save Settings> in the WAN tabbed interface to finish the configuration.

Figure 7 Save settings

5 Quick Troubleshooting

Table 2 Quick troubleshooting

Symptom

Solution

The ADSL

The RJ-11 telephone cable must be used and connected to the ADSL and

Link LED

telephone ports correctly.

stays OFF.

 

 

Make sure that:

 

1) You have followed all the steps described above and found no

 

problems.

Access to

2) The IP address of your PC is in the range of allocated valid addresses.

To check it, select the Run option from the Start menu. In the pop-up

the Internet

window, input winipcfg (in Win98 operating system) or ipconfig (in

fails.

Win2000/XP operating system) for the IP address checking.

 

3) You can ping the IP address of the gateway (192.168.1.1).

 

4) You have performed the correct DNS configuration on your PC.

 

5) You have disabled the proxy server.

 

6) The correct VPI/VCI value is set on the WAN Setup window.

 

Both of the default user name and password are admin. If you have

You forget

changed the password but forget it, press the Reset button for 5 seconds

to restore the default settings on the router. Then you can access the Web

the login

page with the default user name and password.

password.

Note: The reset function restores the settings to the factory default

 

 

settings.

 

Make sure that:

Access to

1) The LAN LED is ON.

the router

2) The settings of TCP/IP properties are correct.

Web pages

3) You have entered the correct user name and password.

fails.

If you still cannot access the router Web pages, press the Reset button for

 

5 seconds to restore the default settings.

The

 

modification

You need to click <Save Settings> to save every modification that you

on the Web

have made.

pages fails

 

to save.

 

Loading...