Store devices and accessories in temperature –10°C to +35°C and relative humidity 30%–85%
RH for at most 9 months. If the ambient temperature or relative humidity is overhigh or overlow,
the device may be faulty.
Used only indoors. Do not lead metallic cables, such as network cables and telephone lines
outdoors.
Do not look directly into the optical port without eye protection.
Keep the device out of the reach of children as the components or accessories may be
swallowed.
Install the device in strict compliance with the requirements of the supplier. Reserve a space of
at least 10 cm above and around the device for heat dissipation. During the installation, keep
the device away from electric appliances that generate strong magnetic or electric fields, such
as microwave ovens, refrigerators, and mobile phones.
The described input voltage range should comply with the local power grid. For example, the
input voltage of the adapter is 200–240 V AC for European Union; the input voltage of the
adapter is 100–140 V AC for America.
If the power adapter is damaged and its internal circuit is exposed due to manmade factors, do
not touch the exposed circuit, which may bring safety risks.
Only power adapters delivered with the device can be used. Otherwise, the device may be
abnormal or unsecure.
Dry your hands before connecting or disconnecting cables. Stop the device and switch off the
power before connecting or disconnecting cables.
Do not place any object on the device, so that the device will not be damaged due to
overheating or deformation.
Prevent objects, such as metal, from entering the device through the heat dissipation hole.
Switch off the power and disconnect all cables, including the power cable, optical fiber, and
network cable, during periods of lightning activities. The socket-outlet shall be installed near
the power adapter and shall be easily accessible. Before use the power adapter, please check
no damage on the adapter.
Do not lead the strength member of the optical fiber or other metal parts indoors. Do not install
telephone lines, network cables, power adapters or power adapter cables outdoors. Adopting
these measures will help prevent device damage and bodily injuries which are especially prone
during thunderstorms.
If an abnormality occurs, for example, liquid entering the device, smoke, unusual sound,
and smell, stop the device immediately, switch off the power, disconnect all cables (such as
the power cable, optical cable, and network cable) to the device, and contact the authorized
service center.
Do not disassemble the device without permission. In the case of a device fault, contact the
authorized service center.
Dispose of the packing materials, expired batteries, and old or abandoned devices in
accordance to local laws and regulations (recycling them is strongly recommended).
Do not change the structure, safety design, or performance design of the device without prior
authorization.
The device should be installed and operated with a minimum distance of 20 cm between the
radiator and your body.
1
FCC ID:QISEG8245HE
Ech oLife E G8245 H
Manuf actu red: MM,Y YYY
IP:19 2.16 8.18 .1
usern ame: Epus er
passw ord: user Ep
Fireproof precautions:
FCC ID:QISEG8245HE
EchoLife EG 8245H
Manufactured: MM,YYYY
IP:192.168.18 .1
username:Epus er
password:user Ep
Keep the device away from large heat source equipment, bare ames, and high-power devices,
such as electric heaters, candles, and blow drier, to eliminate safety risks.
If there are aged cables or power socket facilities on the power supply line to or near the
device, replace them in time to eliminate safety risks. The power supply voltage of the device
must meet the input voltage requirement.
Laser Safety:
Detailed description
Keep the optical ports of the module clean, and cap them when they are not used.
Prevent the end faces of the optical interfaces of the module from being damaged by hard
objects.
Exercise caution when removing and reinserting the fibers for the SC optical ports on the
module. Do not damage the ceramic sockets of optical components.
The goldfinger unit of the module supports no more than 50 times of removal and reinsertion.
Laser products that are safe during use, including long-term direct intrabeam viewing, even
when exposure occurs while using optical viewing instruments (eye loupes or binoculars).
Class 1 also includes high power lasers that are fully enclosed so that no potentially hazardous
radiation is accessible during use (embedded laser product).Intrabeam viewing of Class 1 laser
products which emit visible radiant energy may still produce dazzling visual effects, particularly
in low ambient light.
Do not look into fiber end faces without eye protection using an optical meter (such as magnifier
and microscope) within 100 mm, unless you ensure that the laser output is disabled. When
operating an optical meter, observe the operation requirements.
This device complies with IEC 60825-1: 2007-03 Rule.
Output average power
Under normal circumstances, the maximum optical output average power of the optical module
is 8.0dBm. In the abnormal case, output average power of the optical module is less than 11
dBm.
Nameplate information
Class 1 warning sign is written on the product lable,which is posted on the product.
“Complies with 21 CFR 1040.10 and 1040.11 except for deviations Pursuant to Laser Notice
No.50,dated June 24,2007” is written on the product lable,which is posted on the product.
The manufacturer’s address and production date information is reected in the product lable,
which is attached on the above of the product.
2
Product Overview
Product Function
4 Ethernet ports
2 POTS ports
EG8245H
1 USB port
Wi-Fi access
Technical Specifications
Item Specifications
Weight (including the power
adapter)
About 1000 g
System power supply See the nameplate on the device.
Power adapter input See the nameplate on the adapter.
Maximum power consumption ≤15.5 W
Ambient temperature 0ºC- +40ºC
Ambient humidity 5% RH - 95% RH (non-condensing)
The appearance shown in this document may be different from the actual appearance
of the product. The actual product provided by the carrier prevails.
Installing the GPON Terminal
1. Do not install GPON terminals outdoors or on the outdoor cabinets.
2. GPON terminals can be mounted onto a wall or be placed on a
workbench. Do not install GPON terminals in other modes, such as the
ceiling.
3. The terminal cannot be connected to other devices such as GPON
terminals, switch and router.
4.Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
3
Mounting a GPON terminal on the desk
The figure below shows an EG8245H that is horizontally placed on a desk.
Mounting a GPON terminal onto the wall
Step 1 Mark the positions of two holes used for mounting a GPON terminal, ensure
that the two holes have the same spacing as the two mounting holes.
Step 2 Select a proper drill according to the outer diameter of the screws. Use a
hammer drill to drill the marked positions on the wall. Then clean the wall and
install two expansion bolts.
Step 3 Use a screwdriver to fasten the screws into the expansion bolts, leaving the
heads of the screws 3 mm over the wall. Then install the GPON terminal to the
screws.