DA3100 Evaluation Sample User Manual V1.2 |
Security Level |
1.Introduction
DA3100 is an on-board diagnostic (OBD-II) device that enables collection of data from vehicle OBD-II port, GPS and Accelerometer. It supports 2G/3G and Bluetooth 4.0 LE (optional) communication with telematics service terminal (TST) servers and smart phones respectively.
2.Objective
This manual provides users with guidance of DA3100’s installation, viewing and processing of data collected. Section 3 describes viewing of data collected on Huawei’s demo web portal. For performance evaluation proposes, section 4 outlines the steps to amend server address and message format decoding at the server of choice.
3.Functional Usage
3.1.DA3100 Installation
i.Insert a valid 2/3G SIM into the SIM slot with the contact points facing the bottom as follow:
Note: only support GSM, GPRS and WCDMA
ii.Plug it into the vehicle OBD-II connector with the ignition on. Location varies between vehicles. Normally, it is below the dashboard near the leg room area.
2013-05-30 |
Huawei Proprietary - Restricted Distribution |
Page1, Total12 |
DA3100 Evaluation Sample User Manual V1.2 |
Security Level |
3.2. DA3100 Operation Steps
Step |
Pre-condition |
Action |
Response |
Remark |
|
|
|
|
|
|
|
|
Ignition On and |
Plug DA3100 into the vehicle |
All 3 LEDs will be On for 3 sec. |
If any LED is off, it indicates that |
|
1 |
locate the OBD-II |
OBD-II connection |
|
particular LED is faulty. |
|
|
connection |
|
|
|
|
|
|
|
|
|
|
|
|
|
a. OBD LED Flashing with |
a. Vehicle OBD-II supported |
|
|
|
|
Cellular and Power LED On |
|
|
|
|
DA3100 checking vehicle |
for 20 sec. |
|
|
2 |
Step 1 |
OBD-II protocol |
|
|
|
b. OBD LED Off with Cellular |
b. Vehicle OBD-II not supported |
||||
|
|
||||
|
|
|
and Power LED On for 20 |
|
|
|
|
|
sec. |
|
|
|
|
|
|
|
|
|
|
|
a. Cellular LED Flashing with |
a. Carrier network registration |
|
|
|
|
Power LED On and OBD |
success |
|
|
|
|
LED status as in Step 2 |
|
|
3 |
Step 2 |
DA3100 registering network |
|
|
|
b. Cellular LED Off with Power |
b. Carrier network registration fails. |
||||
|
|
|
|||
|
|
|
LED On and OBD LED status |
Disconnect and repeat step 1 |
|
|
|
|
as in Step 2 |
|
|
|
|
|
|
|
|
|
|
|
a. SMS reply OK |
a. APN set success |
|
|
|
Setting APN through SMS as |
|
|
|
|
|
b. SMS reply fail or no SMS |
b. Repeat Step 4 after 5 sec. Possible |
||
4 |
Step 3a |
|
|
|
|
|
|
described in Section 3.3 (i) |
reply |
fault: SIM does not support APN |
|
|
|
|
|
or server is down |
|
|
|
|
|
|
|
|
|
Data view as described in |
a. If vehicle OBD-II supported |
a. Data view display VIN code read |
|
|
|
Section 3.4 |
as in Step 2a |
from vehicle |
|
5 |
Step 4a |
|
|
|
|
|
b. If vehicle OBD-II not |
b. Data view display VIN code as |
|||
|
|
|
|||
|
|
|
supported as in Step 2b |
“OBD fail” |
|
|
|
|
|
|
|
6 |
Ignition Off |
DA3100 to go into sleep |
|
|
|
|
|
mode and heartbeat send |
All 3 LEDs Off and heartbeat |
Data view display VIN code as |
|
|
|
according to SMS setting as |
send |
“Heartbeat” |
|
|
|
described in Section 3.3 (iv) |
|
|
|
|
|
|
|
|
|
7 |
Step 6 |
Ignition On |
DA3100 back to status before |
|
|
|
|
|
ignition Off |
|
|
|
|
|
|
|
2013-05-30 |
Huawei Proprietary - Restricted Distribution |
Page2, Total12 |
DA3100 Evaluation Sample User Manual V1.2 |
Security Level |
3.3.Configuration through SMS
Device can be configured via SMS commands. These commands are sent to the device SIM number and the device will reply with an SMS response. Below are the commands and responses.
i.Set the APN according to the network carrier provided (Note: APN MUST be set upon initialization of device usage. There is no default setting)
SMS Command: +MTP:1000,<USN>,<PWD>,<NAME>
Response (via SMS): Tips:APN UserName:<USN>,APN Password:<PWD>,APN Name: <NAME> setting ok!
<USN>: APN user name, blank if not applicable <PWD>: APN password, blank if not applicable <NAME>: APN name
ii.Set the data upload time (default is 30 second) SMS Command: +MTP:1001,<TIME>
Response (via SMS): Tips:MTP Report Period:<TIME> setting ok!
<TIME >: upload time in seconds (min is 1 second)
iii.Retrieve system parameters and status for settings confirmation SMS Command: +MTP:1002
Response (via SMS): Tips:SoftVer:<VER>,APN UserName:<USN>,APN Password:<PWD>,APN Name:<NAME>,IP:<IP>,PORT: <PORT>,Report Period:
<TIME >,Server Connect Status:OK!
<VER>: software version, eg. V1.000.20130108 <USN>: APN user name, blank if not applicable <PWD>: APN password, blank if not applicable
<IP>: IP address, eg. 172.22.44.33 (Note: Huawei server IP address) <PORT>: Port number, eg. 12001 (Note: Huawei server port number) <TIME>: upload time in seconds
iv. Set the heartbeat time (default is 1 second) SMS Command: +MTP:1004,<TIME>
Response (via SMS): Tips:Heartbeat Period:<TIME> setting ok!
< TIME >: heartbeat time in seconds
2013-05-30 |
Huawei Proprietary - Restricted Distribution |
Page3, Total12 |
DA3100 Evaluation Sample User Manual V1.2 |
Security Level |
3.4.Web Data View (TST)
i.Log on to http://124.238.215.168:8080/TSP-PORTAL/
Username
Password
Login
ii.Enter the following: Username: 88888888888 Password: 11111111
iii.Click on “Road Safety”
Click on “Road Safety”
2013-05-30 |
Huawei Proprietary - Restricted Distribution |
Page4, Total12 |