Huawei DA3100S User Manual

DA3100 Evaluation Sample User Manual V1.2

Security Level

1.Introduction

DA3100 is an on-board diagnostic (OBD-II) device that enables collection of data from vehicle OBD-II port, GPS and Accelerometer. It supports 2G/3G and Bluetooth 4.0 LE (optional) communication with telematics service terminal (TST) servers and smart phones respectively.

2.Objective

This manual provides users with guidance of DA3100’s installation, viewing and processing of data collected. Section 3 describes viewing of data collected on Huawei’s demo web portal. For performance evaluation proposes, section 4 outlines the steps to amend server address and message format decoding at the server of choice.

3.Functional Usage

3.1.DA3100 Installation

i.Insert a valid 2/3G SIM into the SIM slot with the contact points facing the bottom as follow:

Note: only support GSM, GPRS and WCDMA

ii.Plug it into the vehicle OBD-II connector with the ignition on. Location varies between vehicles. Normally, it is below the dashboard near the leg room area.

2013-05-30

Huawei Proprietary - Restricted Distribution

Page1, Total12

DA3100 Evaluation Sample User Manual V1.2

Security Level

3.2. DA3100 Operation Steps

Step

Pre-condition

Action

Response

Remark

 

 

 

 

 

 

Ignition On and

Plug DA3100 into the vehicle

All 3 LEDs will be On for 3 sec.

If any LED is off, it indicates that

1

locate the OBD-II

OBD-II connection

 

particular LED is faulty.

 

connection

 

 

 

 

 

 

 

 

 

 

 

a. OBD LED Flashing with

a. Vehicle OBD-II supported

 

 

 

Cellular and Power LED On

 

 

 

DA3100 checking vehicle

for 20 sec.

 

2

Step 1

OBD-II protocol

 

 

b. OBD LED Off with Cellular

b. Vehicle OBD-II not supported

 

 

 

 

 

and Power LED On for 20

 

 

 

 

sec.

 

 

 

 

 

 

 

 

 

a. Cellular LED Flashing with

a. Carrier network registration

 

 

 

Power LED On and OBD

success

 

 

 

LED status as in Step 2

 

3

Step 2

DA3100 registering network

 

 

b. Cellular LED Off with Power

b. Carrier network registration fails.

 

 

 

 

 

 

LED On and OBD LED status

Disconnect and repeat step 1

 

 

 

as in Step 2

 

 

 

 

 

 

 

 

 

a. SMS reply OK

a. APN set success

 

 

Setting APN through SMS as

 

 

 

 

b. SMS reply fail or no SMS

b. Repeat Step 4 after 5 sec. Possible

4

Step 3a

 

 

 

 

 

described in Section 3.3 (i)

reply

fault: SIM does not support APN

 

 

 

 

or server is down

 

 

 

 

 

 

 

Data view as described in

a. If vehicle OBD-II supported

a. Data view display VIN code read

 

 

Section 3.4

as in Step 2a

from vehicle

5

Step 4a

 

 

 

 

b. If vehicle OBD-II not

b. Data view display VIN code as

 

 

 

 

 

 

supported as in Step 2b

“OBD fail”

 

 

 

 

 

6

Ignition Off

DA3100 to go into sleep

 

 

 

 

mode and heartbeat send

All 3 LEDs Off and heartbeat

Data view display VIN code as

 

 

according to SMS setting as

send

“Heartbeat”

 

 

described in Section 3.3 (iv)

 

 

 

 

 

 

 

7

Step 6

Ignition On

DA3100 back to status before

 

 

 

 

ignition Off

 

 

 

 

 

 

2013-05-30

Huawei Proprietary - Restricted Distribution

Page2, Total12

DA3100 Evaluation Sample User Manual V1.2

Security Level

3.3.Configuration through SMS

Device can be configured via SMS commands. These commands are sent to the device SIM number and the device will reply with an SMS response. Below are the commands and responses.

i.Set the APN according to the network carrier provided (Note: APN MUST be set upon initialization of device usage. There is no default setting)

SMS Command: +MTP:1000,<USN>,<PWD>,<NAME>

Response (via SMS): Tips:APN UserName:<USN>,APN Password:<PWD>,APN Name: <NAME> setting ok!

<USN>: APN user name, blank if not applicable <PWD>: APN password, blank if not applicable <NAME>: APN name

ii.Set the data upload time (default is 30 second) SMS Command: +MTP:1001,<TIME>

Response (via SMS): Tips:MTP Report Period:<TIME> setting ok!

<TIME >: upload time in seconds (min is 1 second)

iii.Retrieve system parameters and status for settings confirmation SMS Command: +MTP:1002

Response (via SMS): Tips:SoftVer:<VER>,APN UserName:<USN>,APN Password:<PWD>,APN Name:<NAME>,IP:<IP>,PORT: <PORT>,Report Period:

<TIME >,Server Connect Status:OK!

<VER>: software version, eg. V1.000.20130108 <USN>: APN user name, blank if not applicable <PWD>: APN password, blank if not applicable

<IP>: IP address, eg. 172.22.44.33 (Note: Huawei server IP address) <PORT>: Port number, eg. 12001 (Note: Huawei server port number) <TIME>: upload time in seconds

iv. Set the heartbeat time (default is 1 second) SMS Command: +MTP:1004,<TIME>

Response (via SMS): Tips:Heartbeat Period:<TIME> setting ok!

< TIME >: heartbeat time in seconds

2013-05-30

Huawei Proprietary - Restricted Distribution

Page3, Total12

Huawei DA3100S User Manual

DA3100 Evaluation Sample User Manual V1.2

Security Level

3.4.Web Data View (TST)

i.Log on to http://124.238.215.168:8080/TSP-PORTAL/

Username

Password

Login

ii.Enter the following: Username: 88888888888 Password: 11111111

iii.Click on “Road Safety”

Click on “Road Safety”

2013-05-30

Huawei Proprietary - Restricted Distribution

Page4, Total12

Loading...
+ 8 hidden pages