HP NetServer L Pr
with
XP256 (Fibre Channel or SCSI)
Cluster Configuration Guide
08 February, 2000
Introduction
This document defines the supported HP NetServer LPr configurations with the XP256 and Microsoft
Cluster Server. These configurations minimize single points of failure (SPOF), provide maximum
availability, and have been certified by Hewlett-Packard or Microsoft. This guide is prescriptive; it
describes the configurations supported by HP. Any deviance to these configurations can result in an
inoperative cluster or an operating cluster with degraded performance, hidden SPOFs, etc., and th erefore
will not be supported by HP.
What’s Defined in a Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs HP NetServer LPr.
Each node must be the same model SPU, but may have different clocks
speeds, main memory sizes, cache sizes, and number of CPUs (2, 3, or 4).
Number of nodes 2
Shared Storage XP256 with FC or SCSI connections. See Shared Storage
LANs:
Client LAN Any NIC that is HP and Microsoft approved. See Client LAN below.
Intra-cluster
(Heartbeat) LAN
Power source Direct from power mains, power conditioner or uninterruptible power
System software:
Navigator version L.16.05 or later
Operating System Microsoft Windows NT Server 4.0, Enterprise Edition or later
Service pack SP5 or later
HP D5013A with crossover cable. See Intra-cluster LAN below.
supply (UPS) using any power conditioner or UPS.
below.
1
SPU
Model HP NetServer LPr.
Clock speed 400, 450, 500, or 550 MHz
No. of CPUs 2 – 4
BIOS version 4.06.14PR
CPU cach e Any size
RAM 256 MB minimum. Must be HP.
No. of power supplies 3
Local storage See Local Storage below.
I/O slots: P1 – P4 Sha red stora g e cont roller
P2 – NetRAID-3Si local storage
P3 – Client LAN
P4 – Intra-cluster (Heartbeat) LAN
Storage
Local
Physical drive location SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/8 onl y.
Disk drives Must be HP
Controller Embedded SCSI controller to internal disks or any external cabinet.
NetRAID (D4943A) with firmware A.04.00 or later to internal disks or
Rack Storag e /8 only.
NetRAID-1 (D4992A) with firmware A.04.00 or later to internal disks or
Rack Storag e /8 only.
SCSI bus Any HP cables that meet SCSI specifications and any SCSI bus speed
Shared
Host Bus Adapters
Model D8602A A5252B or Adaptec AHA2944UW
Bus Protocol FC Public NL Ultra Wid e or Fa st Wi d e
No. of HBAs/Server 1 1
Firmware NA N/A
BIOS NA 2.11 (B.01.08)
Driver 2.00 or later
SPU I/O slot P3 – P4 P3-P4
SCSI ID NA 7 or 6
Registry Changes I/O Timeout= 60 Seconds I/O Timeout=60 seconds
Fibre Channel HBA SCSI HBA
SP5 bundle version
Available at
http://www.semiconductor.agilent.
com/io/hhba5101.html
Queue Tag Count=8
(MAXTAGS=8)
2