HP VA7410, VA7110 User Manual

Chapter 4
Peripherals and Accessories
Subchapter 4.7—Disk Arrays
4.7.1—HP StorageWorks Virtual Array 7000 Family: VA7100, VA7110 and VA7410
The HP StorageWorks VA7000 Family arrays that support MPE/iX include the VA7100, VA7110 , and VA7410 arrays. Where sections are specific to a particular array, they are called out. If a section is not specifically called out, it is common to all.
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership Website (external):
Spock Website:
For VA7410 array: http://nss-streams.corp.hp.com/xp_documentation/va7410_docs.htm
For VA7100 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7100_docs.htm
For VA7110 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7110_docs.htm
Partnership Website:
http://partner.americas.hp.com/
Enterprise Virtual Array (EVA)
For information on EVA support, please visit the following URLs:
For Installation and Configuration and Release Notes
In Spock, go to “Disk Array Connectivity” and select: HP StorageWorks EVA Technical Documentation
Go there directly with the following URL:
http://h18000.www1.hp.com/products/storageworks/enterprise/documentation.html
For Disk Array Connectivity
HP StorageWorks EVA Product Index
Go there directly with the following URL:
http://h18000.www1.hp.com/products/storageworks/enterprise/index.html
Overview
VA7100 Overview
The HP StorageWorks Virtual Array 7100 is a disk storage system that holds from 4 to 15 disk drives. The array has scalable capacities from 72 GB to 270 GB (211 GB usable) with all 18-GB disk drives and from 144 GB to 540 GB (428 GB usable) with all 36-GB disk drives and from 292 GB to 1.1 TB with 73-GB disk drives. Capacities and spindle speeds can also be mixed. The array requires a dual controller configuration to support MPE/iX. At least one controller must be attached to a management station running the HP StorageWorks Command View SDM software. Each controller has two DIMM slots available to hold NVRAM. The NVRAM is used for read/write caching and for storing array memory maps.
The Virtual Array 7100 can operate in either RAID 1+0 mode or AutoRAID mode, which eliminates the requirement for the system administrator to understand and configure RAID levels. AutoRAID dynamically adapts to the system’s workload, optimizing performance and cost. Users will find configuration significantly easier than other array products, since RAID levels don’t need to be configured or managed. The VA7100 supports one redundancy group, and all drives belong to that group. Using Virtual Storage Array (VSA) technology, when configured in AutoRAID mode the array controller automatically selects RAID 1+0 (disk striping and mirroring) or RAID 5DP (RAID 5 Double Parity) depending on the usage patterns of the data.
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-91
Information Subject to Change
Chapter 4 Peripherals and Accessories
RAID 5DP provides superior data redundancy by protecting against the simultaneous failure of two member disks by using independent error correction schemes.
The VA7100 is designed to communicate with multiple hosts and multiple systems, otherwise known as heterogeneous support. Any combination of the supported operating systems: HP-UX, MPE/iX, Windows NT, Solaris, AiX, NetWare, Windows 2000, and Linux can be used. Two different protocols, or host port behaviors, are used by the array to communicate with the operating systems: one protocol for Windows/Linux/other and another for HP-UX. Depending on the firmware level of the VA7100, another was added for MPE/iX. The Windows/Linux host port behaviors must be configured in the array for communication to take place with any or all four supported operating systems on a controller. When changing the port protocol to Windows/Linux it does support concurrent operation with Windows/Linux and HP-UX. The VA7100 provides simultaneous access by all of the supported operating systems on a LUN-by-LUN basis. Each LUN operates appropriately given the description of the operating system requirements.
The VA7100 can be configured to utilize an active hot spare feature. An active hot spare is a portion of the disk array capacity reserved to perform a rebuild. This feature requires the use of two additional disk units in the array. An active hot spare ensures that the disk array can maintain data redundancy if one or two disks fails. Until it is needed, the disk array uses the active hot spare storage space as RAID 1+0 capacity, which improves array performance. The active hot spare storage capacity does not sit idle; it is used to increase the disk array performance until the storage is needed.
The chassis will accommodate up to 15 low-profile 3.5-inch hard disk drives loaded from the front. The array requires 3 EIA units (3U) in height, which allows 10 units to be placed in a standard 1.6-meter rack. The rear of the 3 EIA rack mountable chassis also includes two 1-GB Fibre Channel controllers, dual power supplies and dual fan modules. The redundant power supply and fan components are combined into a single module. All modules are hot swappable.
The array can be connected to one or more hosts, hubs, or switches via an optical Fibre Channel (FC) interface with 1 gigabit per second transfer rates. It can be ordered in factory-racked, field-rackable, or desk-side configurations. Factory-racked products are pre-configured in the HP Rack/System E racks. Field-rackable products can be racked in HP racks or in Compaq 9000 racks.
The VA7100 is supported by HP’s Instant Support Enterprise Edition (ISEE). HP’s online diagnostic and resolution capability securely delivers remote reactive services that quickly resolve problems, proactive service that anticipate and prevent downtime due to computing issues, and value-added services to help monitor, manage and maintain global IT networks. A minimum level hardware support upgrade of same day is required. It is included with the VA for the first year (in addition to the warranty).
VA7110 Overview
The HP StorageWorks Virtual Array 7110 is a disk storage system that supports from four to 45 disk drives (two additional enclosures with 15 disks in each). The array has scalable capacities from 72 GB to 810 GB (211 GB usable) with all 18-GB disk drives and from 144 GB to 1.6 TB with all 36-GB disk drives and from 292 GB to 3.2 TB with 73-GB disk drives and from 584 GB to 6.5 TB with 146-GB disk drives. Capacities and spindle speeds can also be mixed. The array requires a dual controller configuration to support MPE/iX. At least one controller must be attached to a management station running the HP StorageWorks Command View SDM software. Each controller has two DIMM slots available to hold NVRAM. The NVRAM is used for read/write caching and for storing array memory maps.
The Virtual Array 7110 can operate in either RAID 1+0 mode or AutoRAID mode, which eliminates the requirement for the system administrator to understand and configure RAID levels. AutoRAID dynamically adapts to the system’s workload, optimizing performance and cost. Users will find configuration significantly easier than other array products, since RAID levels don’t need to be configured or managed. The VA7110 supports one redundancy group, and all drives belong to that group. Using Virtual Storage Array (VSA) technology, when configured in AutoRAID mode the array controller automatically selects RAID 1+0 (disk striping and mirroring) or RAID 5DP (RAID 5 Double Parity) depending on the usage patterns of the data. RAID 5DP provides superior data redundancy by protecting against the simultaneous failure of two member disks by using independent error correction schemes.
4-92 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
The VA7110 is designed to communicate with multiple hosts and multiple systems, otherwise known as heterogeneous support. Any combination of the supported operating systems—HP-UX, Windows NT, Solaris, AiX, NetWare, Windows 2000, MPE/iX, and Linux can be used. Two different protocols, or host port behaviors, are used by the array to communicate with the operating systems: one protocol for Windows/Linux/other and another for HP-UX. The Windows/Linux host port behaviors must be configured in the array for communication to take place with any or all four supported operating systems on a controller. When changing the port protocol to Windows/Linux it does support concurrent operation with Windows/Linux and HP-UX. The VA7110 provides simultaneous access by all of the supported operating systems on a LUN-by-LUN basis. Each LUN operates appropriately given the description of the operating system requirements.
The VA7110 can be configured to utilize an active hot spare feature. An active hot spare is a portion of the disk array capacity reserved to perform a rebuild. This feature requires the use of one or two additional disk units in the array. An active hot spare ensures that the disk array can maintain data redundancy if one or two disks fails. Until it is needed, the disk array uses the active hot spare storage space as RAID 1+0 capacity, which improves array performance. The active hot spare storage capacity does not sit idle; it is used to increase the disk array performance until the storage is needed.
Each enclosure will accommodate up to 15 low-profile 3.5-inch hard disk drives loaded from the front. The array requires three EIA units (3U) in height (per enclosure), which allows ten units to be placed in a standard
1.6-meter rack. The rear of the EIA rack mountable chassis also includes two 1-GB fibre channel controllers, dual power supplies and dual fan modules. The redundant power supply and fan components are combined into a single module. All modules are hot swappable.
The array can be connected to one or more hosts, hubs, or switches via an optical fibre channel (FC) interface with 1 or 2 gigabit per second transfer rates (the default setting is 1 gigabit). It can be ordered in factory-racked, field-rackable, or desk-side configurations. Factory-racked products are pre-configured in the HP Rack/System E racks. Field-rackable products can be racked in HP racks or in Compaq 9000 racks.
The VA7110 is supported by HP’s Instant Support Enterprise Edition (ISEE). HP’s online diagnostic and resolution capability securely delivers remote reactive services that quickly resolve problems, proactive service that anticipate and prevent downtime due to computing issues, and value-added services to help monitor, manage and maintain global IT networks. A minimum level hardware support upgrade of same day is required. It is included with the VA for the first year.
The revision numbering for firmware for the VA7110 has changed. The revision numbering now consists of a string of 4 ASCII characters (the HP designation has gone away). For example, a revision code of “X123” represents the following:
“X” is a single capital letter (A – Z) designating the platform
“1” is a single number or capital letter (0-9, A-Z) designating a major FW revision
“2” is a single number or capital letter (0-9, A-Z) designating a minor FW revision
“3” is a single number or capital letter (0-9, A-Z) designating a sub-minor FW revision
VA7410 Overview
The HP StorageWorks Virtual Array 7410 is a Fibre Channel (FC) disk storage system that supports from ten to 105 disk drives. The VA7410 has two FC ports on each controller. The VA7410 is comprised of two types of enclosures, each three EIA units high: the virtual array controller enclosure (A6183A/AZ) and the disk system enclosure (A6214A/AZ) also referred to as the disk enclosure or the JBOD (Just a Bunch Of Disks) enclosure. In addition, pre-defined SKUs are available to facilitate integrated arrays. The array consists of one controller enclosure and one to six disk enclosures, with scalable capacities from 181 GB to 1.90 TB (using 18-GB 15K rpm disk drives), 364 GB to 3.82 TB (using 36-GB 10K rpm disk drives), 720 GB to 7.67 TB (using 73-GB 10K rpm disk drives), or 1.46 TB to 15.33 TB (using 146-GB 10K rpm disk drives). Capacities and spindle speeds can also be mixed throughout the array.
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-93
Information Subject to Change
Chapter 4 Peripherals and Accessories
Both enclosures include dual power supplies with built-in dual blowers, and accommodate up to 15 low-profile
3.5-inch native fibre channel (FC) disk drives in the front. The controller enclosure also includes dual redundant 1 or 2-Gbps FC capable array controller cards and the disk enclosure also includes dual redundant 1- or 2-Gbps link controller cards for back-end connections to the controllers. All field replaceable units are hot swappable. The array controller cards, however, must be replaced offline if the OS does not support controller failover.
The VA7410 can operate in either RAID 1+0 mode or AutoRAID mode. These data protection levels are user selectable at the time of initial array installation. Using Virtual Storage Array (VSA) technology, when configured in AutoRAID mode the array controller automatically selects RAID 1+0 (disk striping and mirroring) or RAID 5DP (RAID 5 Double Parity) depending on the usage patterns of the data. This protection scheme eliminates the requirement for the system administrator to understand and configure RAID levels.
RAID 5DP provides superior data redundancy by protecting against the simultaneous failure of two member disks by using independent error correction schemes. Users will find configuration significantly easier than other array products, since RAID levels don’t need to be configured or managed. The VA7410 supports two redundancy groups, which provides for physical data path separation of the two groups of LUNS.
The VA7410 is architected to communicate with multiple hosts and operating systems, otherwise known as a simultaneous heterogeneous environment. For details on supported operating systems, please refer to the Spock Website and Partnership Website:
Spock website:
For VA7410 array: http://nss-streams.corp.hp.com/xp_documentation/va7410_docs.htm
For VA7400 array: http://nss-streams.corp.hp.com/xp_documentation/va7400_docs.htm
For VA7110 array: http://nss-streams.corp.hp.com/xp_documentation/va7110_docs.htm
For VA7100 array: http://nss-streams.corp.hp.com/xp_documentation/va7100_docs.htm
Partnership website:
http://partner.americas.hp.com/
One host port behavior is initially set in controller firmware, and then heterogeneous support for all other operating systems is enabled through software in a host port behavior table. The controller default host port behavior is set for HP-UX. The VA7xxx products are managed by the HP Command View SDM host-resident software. A one-host license to use for HP StorageWorks Command View SDM is included with each VA7410. Currently HP StorageWorks Command View SDM runs native on HP-UX, Windows NT, Windows 2000 and Red Hat Linux 6.2, 7.1. Installations on any of the other supported operating systems will require a dedicated management station running one of the aforementioned operating systems to be in the data path of the VA7410 (i.e. in the switched fabric).
The VA7410 can be configured to use an active hot spare feature. An active hot spare is a portion of the array capacity reserved to perform a rebuild. This feature requires the use of additional disk drives in the array. Users can select from 0, 1, or 2 active hot spares. An active hot spare ensures that the array can maintain data redundancy if one or two disks fail. Until it is needed, the array uses the active hot spare storage space as RAID 1+0 capacity, which improves array performance. The active hot spare storage capacity does not sit idle; it is used to increase the array performance until the storage it is needed.
The VA7410 can be connected to one or more hosts, hubs, or switches via an optical fibre channel (FC) interface with OS-dependant, 1- or 2-Gbps transfer rates. The default factory setting is 1-Gbps. It can be ordered in factory-racked and field-rackable configurations. Factory-racked products are pre-configured in the HP Rack/System E racks. Field-rackable products can be racked in HP racks or in Compaq 9000 racks.
The VA7410 is supported by HP’s Instant Support Enterprise Edition (ISEE). HP’s online diagnostic and resolution capability securely delivers remote reactive services that quickly resolve problems, proactive service that anticipate and prevent downtime due to computing issues, and value-added services to help monitor, manage and maintain global IT networks. A minimum level hardware support upgrade of same day is required.
4-94 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
New Firmware Revision Code Designation for VA7410
Note: The release firmware for the VA7410 is “A100”.
The revision numbering for firmware for the VA7410 has changed. The revision numbering now consists of a string of 4 ASCII characters (the HP designation has gone away). For example, a revision code of “X123” represents the following:
“X” is a single capital letter (A – Z) designating the platform
“1” is a single number or capital letter (0-9, A-Z) designating a major FW revision
“2” is a single number or capital letter (0-9, A-Z) designating a minor FW revision
“3” is a single number or capital letter (0-9, A-Z) designating a sub-minor FW revision
Important VA7410/DS2405 Notes:
On the VA7410 only the DS2405 is supported. For the VA7410, HP StorageWorks Command View SDM software version 1.05 or later is required.
Disk drive firmware may need to be upgraded. For more information, please check the Service Note server at the following site and do a search on the VA family via product numbers to see all available and relevant service notes: http://snserver.mayfield.hp.com/ServiceNotes/Snwebsite/SearchbyProdNum.asp
Additionally, on the DS2405, the LCC FC loop speed must be set to 2-Gbps (this is the factory default). If needed, refer to the DS2405 User Guide on setting LCC speed.
The DS2405 is not supported connected directly to a switch.
If you are upgrading to a VA7410 from an array with DS2400 JBODs, the DS2400 JBODs must also be
upgraded to DS2405 JBODs.
Product Features
Integrated VA arrays contain two (2) controllers. The array controllers contain the intelligence and functionality required to manage the operation of the entire array. The array functions include:
Implementing HP Virtual Storage Technology to ensure optimum performance and cost-efficient data storage
Managing all communication between the host and the disk drives via single or dual controller Fibre Channel arbitrated loops
Maintaining data integrity by automatically correcting any data errors that occur
Rebuilding the array in the event of a disk failure
Monitoring the operation of all hardware components, including the controller itself
Alerting the host in the event of a component failure
The use of two controllers protects the array against a single controller failure. Both controllers may be active, allowing a possible increase in performance, while providing data redundancy.
Each configured array controller includes the following components:
One (1) or two (2) Dual Inline Memory Modules (DIMMs), purchased separately if an additional Virtual Array Controller is added
One (1) Battery
One (1) Early Warning Switch
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-95
Information Subject to Change
Chapter 4 Peripherals and Accessories
Performance, Throughput and Capacity
Item Value
Throughput Host Interface VA7100 100 MB/s FC Throughput Host Interface VA7110 200 MB/s FC Throughput Host Interface VA7400 200 MB/s FC Throughput Host Interface VA7410 200 MB/s FC Drive Interface 100 MB/s FC Disk System Capacity VA7100 1095 GB raw capacity Disk System Capacity VA7110 6.5 TB raw capacity Disk System Capacity VA7400 7.6 TB GB raw capacity Disk System Capacity VA7410 15.3 TB GB raw capacity Storage Controller High-performance Virtual Array Controller Disk Drive Capacity 18 GB, 36.4 GB 73 GB and 146 GB (Note the 146 GB drive is for the VA7110 only Rotational Velocity 10K RPM and 15K RPM Disk Drive Transfer Rate 10K = 26 MB/s (or better); 15K = 38 MB/s (or better) Disk Drive Average Seek Time 10K = 4.7 ms (or better) Read, 5.2 ms (or better) Write; 15K = 3.6 ms (or better) Read, 4.2 ms (or better) Write Disk Drive Average Latency 10K = 2.99 ms, 15K = 2.00 ms
VA7110 Disk Enclosure Specifications (DS2405)
Physical Specifications
Height Width Depth Net Weight Max Shipping Weight Max
5 in 17.6 in 20 in 84.5 lbs 101.5 lbs 128 mm 448 mm 508 mm 38.3 kg 46 kg
Electrical Specifications
Parameter Value
Voltage (Auto-Ranging) 100-127 VAC; 200-240 VAC Frequency 50/60 Hz Current (Maximum; 2 power inputs) 8.2 A @ 100 VAC, 3.4 A @ 200 VAC Inrush Current (Peak) 3.92 A @ 269 VAC Power Consumption 473 W @ 120 VAC, 457 W @ 240 VAC Heat Dissipation 1443 BTU/hr VA Rating (Maximum Configuration) 473 VA @ 120 VAC, 457 VA @ 240 VAC
Environmental Specifications
Parameter Operating Range Recommended Range Non-Operating
Temperature 5° to 35° C (41° to 95° F) 20° to 25.5° C (68° to 78° F) –40° to 70° C (-40° to 158° F) Temperature Gradient 20° C (36° F) per hour 20° C (36° F) per hour 20° C (36° F) per hour Relative Humidity (Non-Condensing) 15% to 80% @ 28° C (dry bulb) 30% to 50% @ 28° C (dry bulb) 5% to 95% @ 65° C (149° F) Shock 4 g, 11 ms (20 low-impulse pulses) N/A 20 g, 30 ms trapezoidal
(non-transport) 1-inch edge drops per side (transport)
Vibration 0.21 g rms, 5- to 500-Hz random N/A 2.09 g rms, 5- to 500-Hz random
0.5 g peak, 5- to 500-Hz swept sine Altitude 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 15,000 ft (0 to 4,572 m) Acoustic (ISO 9296) 8.0 bels 8.0 bels N/A
Regulatory Compliance
Parameter Specification
Radiated and Conducted Emissions FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998 Immunity EN 55024: 1998/CISPR-24: 1997 Harmonic Current IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14 Voltage Fluctuations and Flicker IEC 61000-3-3: 1994/EN 61000-3-3: 1995 Product Safety EN 60950: 1991, Second Edition + A1, A2, A3, and A4
CAN/CSA - C22.2 No. 60950-00, Third Edition UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11 Class 1 (Laser/LED) GB4943: 1995
4-96 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Warranty
Included with every VA7000 Family Array:
Warranty: 2-year, 8×5, same-day, 4-hour on-site response for hardware with a 2-year 8×5 phone-in assistance, 2-hour response for HP StorageWorks Command View SDM phone-in assistance (PIA)
Required with purchase:
VA Family Hardware and Software: Installation service—H4726A
Pre-installation review
Hardware installation
Software enablement
LUN Design and Implementation
Customer documentation and orientation
VA Family Software: 8×5 Phone-in-Assistance (H4403A, Support Pack)
Instant Support Enterprise Edition Support (ISEE)
What is Instant Support Commercial
HP Instant Support is a unique combination of web-based self-service diagnostics and knowledge base access and is offered as a free value-added service for HP desktop computers, mobile computers, technical workstations, and PC servers.
ISC Value Proposition
HP Instant Support automates and speeds the resolution of computing problems, freeing customers from time-consuming diagnostic chores and returning them to more productive business-critical tasks.
Links of Interest
Instant Support Commercial (European server)—
http://instantsupport.europe.hp.com/motivedocs/hpinstantsupport.html
www.hp.com/go/instantsupport
Instant Support (desktop/printers)—WW Marketing Page http://www.hp.com/go/instantsupport
HPCS eDelivery EMEA—http://hpsedelivery.europe.hp.com/
HP Business Support—http://h20000.www2.hp.com/bizsupport/index.jsp
Troubleshooting Resources—http://www.hp.com/hps/itsol/suppt_troubleshooting.html
Specifications
VA7100 Specifications
Racked Product Physical Specifications
Height Width Depth Net Weight Minimum
5.0 in 17.6 in 26 in 75 lbs 128 mm 448 mm 660 mm 34 kg
Deskside Product Physical Specifications
Height Width Depth Net Weight Minimum
19 in 16.5 in (box (6.5) + base (10) 26 in 105 lbs 483 mm 419 mm 660 mm 47.6 kg
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-97
Information Subject to Change
Chapter 4 Peripherals and Accessories
Deskside and Racked Product Electrical Specifications (VA7100 only)
Parameter Value
Voltage 100-127 and 200-240 VAC (auto-ranging) Frequency 50/60 Hz Current (Maximum) 7.2 Amps RMS (2 power inputs) Inrush Current (Peak) 36 Amps Power Consumption 670 Watts Heat Dissipation 196 BTU VA Rating (Maximum Configuration) 720 VA
Deskside/Racked Product Environmental Specifications
Parameter Operating Range Recommended Range Non-Operating
Temperature 5° to 35° C 20º C to 25.5º C (68º F to 78º F) –40° to 70° C Temperature Gradient 20° C (36° F) per hour 20° C (36° F) per hour 20° C per hour Relative Humidity (non-condensing) 10% to 80% @ 28° C (wet bulb) 30% to 50% @ 28° C (wet bulb) 10% to 90% @ 28° C (wet bulb) Shock 4 g, 11 ms half sine N/A 4 g, 11 ms half sine Vibration 0.21g rms, 5- to 500-Hz random N/A 2.09 g rms, 5- to 500-Hz random
0.5-g peak, 5- to 500-Hz swept sine Altitude 0 ft to 10,000 ft 0 ft to 10,000 ft 0 ft to 15,000 ft Acoustic (ISO 9296) 8.0 bels 8.0 bels N/A
Deskside/Racked Product Regulatory Compliance
Parameter Specification
Radiated and Conducted Emissions FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998 Immunity EN 55024: 1998/CISPR-24: 1997 Harmonic Current IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14 Voltage Fluctuations and Flicker IEC 61000-3-3: 1994/EN 61000-3-3: 1995 Product Safety EN 60950: 1991, Second Edition + A1, A2, A3, and A4
CAN/CSA - C22.2 No. 60950-00, Third Edition UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11 Class 1 (Laser/LED) GB4943: 1995
VA7110 and VA7410 Controller Enclosure Specifications
Physical Specifications
Height Width Depth Net Weight Max Shipping Weight Max
5 in 17.6 in 26 in 34 lbs 130.1 lbs 128 mm 448 mm 660 mm 41.8 kg 59.0 kg
Electrical Specifications
Parameter Value
Voltage (Auto-Ranging) 100-127 VAC, 200-240 VAC Frequency 50/60 Hz Current (Maximum; 2 power inputs) 8.2 A @ 100 VAC, 3.6 A @ 200 VAC Inrush Current (Peak) 36 A Power Consumption 670 W Heat Dissipation 196 BTU/hr VA Rating (Maximum Configuration) 720 VA
4-98 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Environmental Specifications
Parameter Operating Range Recommended Range Non-Operating
Temperature 5° to 35° C (41° to 95° F) 20º to 25.5º C (68º to 78º F) –40° to 70° C (-40° to 158° F) Temperature Gradient 20° C (36° F) per hour 20° C (36° F) per hour 20° C (36° F) per hour Relative Humidity 15% to 80% @ 28° C (dry bulb) 30% to 50% @ 28° C (dry bulb) 10% to 90% @ 28° C (dry bulb) Shock 4 g, 11 ms half sine N/A 4 g, 11 ms half sine Vibration 0.21 g rms, 5- to 500-Hz random N/A 2.09 g rms, 5- to 500-Hz random
0.5 g peak, 5- to 500-Hz swept sine Altitude 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 15,000 ft (0 to 4,572 m) Acoustic (ISO 9296) 8.0 bels 8.0 bels N/A
Regulatory Compliance
Parameter Specification
Radiated and Conducted Emissions FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998 Immunity EN 55024: 1998/CISPR-24: 1997 Harmonic Current IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14 Voltage Fluctuations and Flicker IEC 61000-3-3: 1994/EN 61000-3-3: 1995 Product Safety EN 60950: 1991, Second Edition + A1, A2, A3, and A4
CAN/CSA - C22.2 No. 60950-00, Third Edition UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11 Class 1 (Laser/LED) GB4943: 1995
DS2405 Disk Enclosure Specifications
Physical Specifications
Height Width Depth Net Weight Max Shipping Weight Max
5 in 17.6 in 20 in 84.5 lbs 101.5 lbs 128 mm 448 mm 508 mm 38.3 kg 46 kg
Electrical Specifications
Parameter Value
Voltage (Auto-Ranging) 100-127 VAC; 200-240 VAC Frequency 50/60 Hz Current (Maximum; 2 power inputs) 8.2 A @ 100 VAC, 3.4 A @ 200 VAC Inrush Current (Peak) 3.92 A @ 269 VAC Power Consumption 473 W @ 120 VAC, 457 W @ 240 VAC Heat Dissipation 1443 BTU/hr VA Rating (Maximum Configuration) 473 VA @ 120 VAC, 457 VA @ 240 VAC
Environmental Specifications
Parameter Operating Range Recommended Range Non-Operating
Temperature 5° to 35° C (41° to 95° F) 20° to 25.5° C (68° to 78° F) –40° to 70° C (-40° to 158° F) Temperature Gradient 20° C (36° F) per hour 20° C (36° F) per hour 20° C (36° F) per hour Relative Humidity (Non-Condensing) 15% to 80% @ 28° C (dry bulb) 30% to 50% @ 28° C (dry bulb) 5% to 95% @ 65° C (149° F) Shock 4 g, 11 ms (20 low-impulse pulses) N/A 20 g, 30 ms trapezoidal
(non-transport) 1-inch edge drops per side (transport)
Vibration 0.21 g rms, 5- to 500-Hz random N/A 2.09 g rms, 5- to 500-Hz random
0.5 g peak, 5- to 500-Hz swept sine Altitude 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 15,000 ft (0 to 4,572 m) Acoustic (ISO 9296) 8.0 bels 8.0 bels N/A
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-99
Information Subject to Change
Chapter 4 Peripherals and Accessories
Regulatory Compliance
Parameter Specification
Radiated and Conducted Emissions FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998 Immunity EN 55024: 1998/CISPR-24: 1997 Harmonic Current IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14 Voltage Fluctuations and Flicker IEC 61000-3-3: 1994/EN 61000-3-3: 1995 Product Safety EN 60950: 1991, Second Edition + A1, A2, A3, and A4
CAN/CSA - C22.2 No. 60950-00, Third Edition UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11 Class 1 (Laser/LED) GB4943: 1995
Figure 4.7.1.1 HP StorageWorks Virtual Array 7000 Family – Front View
Figure 4.7.1.2 HP StorageWorks Virtual Array 7100
Figure 4.7.1.3 HP StorageWorks Virtual Array 7100—Deskside Configuration
4-100 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Figure 4.7.1.4 VA7100—Rear View
Array
Controller
Fibre
Channel
Port
Array
Controller
LEDs
Chapter 4
Peripherals and Accessories
RS-232
Serial
Port
AC Power
Connection
Power
Supply
Figure 4.7.1.5 StorageWorks VA7110—Front and Rear View
43
65
10
13
Array
Controller
LEDs
Figure 4.7.1.6 VA7410—Rear View
Array
Disk PortsFCHost Ports
Controller
Card 1
1 2 1 2
8
7
A 8 1 2 6 A
9
host 2disk 2
FC
11
15
RS-232
Connector
Power
Supply
LEDs
12
A 8 1 2 6 A
1
2
2
hostdisk
1614
Array
Controller
Card 2
AC Power
Connection
Power
Module 1
Power
Module LEDs
Power
Module 2
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-101
Information Subject to Change
Chapter 4 Peripherals and Accessories
Figure 4.7.1.7 StorageWorks DS2405—Rear View
Array
Disk PortsFCHost Ports
Controller
Card 1
1 2 1 2
FC
Array
Controller
LEDs
RS-232
Connector
Array
Controller
Card 2
AC Power
Connection
Power
Module 1
Power
Module LEDs
Power
Module 2
Hardware Ordering Information
VA7100 Hardware Ordering Information
The following codes define the suffixes on product numbers: A = Field Racked, AE = diskless enclosure (field disk integration), AZ = Factory Racked.
Order drives separately from the Enterprise Module section using the 0D1 option for integration. “AE” products are shipped as diskless enclosure only no integration (disks are ordered separately and field installed).
Product Number Option Number Description VA7100 Field RK SKU
A6261A Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 256-MB Cache A6262A Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 512-MB Cache (1×512MB DIMM) A6263A Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM) A6183A Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory
installed). Includes filler for controllers and disks. A6188A 0D1 Virtual Array Controller no memory installed A6185A 0D1 256-MB Cache for Virtual Array Controller, 1×256MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6186A 0D1 512-MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6187A 0D1 2×512MB Cache for Virtual Array Controller, 2×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6192A 0D1 36-GB 10K RPM FC HDD Module A6193A 0D1 36-GB 15K RPM FC HDD Module A6194A 0D1 73-GB 10K RPM FC HDD Module A7288A 0D1 73-GB 15K RPM FC HDD Module A6203A 0D1 Optical Gigabit Interface Circuit (GBIC) A3583A 0D1 2-meter FC fiber optic cable M/M multimode SC-SC A3531A 0D1 16-meter FC fiber optic cable M/M multimode SC-SC A3735A 0D1 50-meter FC fiber optic cable M/M multimode SC-SC A3736A 0D1 100-meter FC fiber optic cable M/M multimode SC-SC C7529A 0D1 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 0D1 16-meter FC fiber optic cable M/M duplex LC-SC C7534A 0D1 FC fiber optic coupler F/F SC-SC C7540A 0D1 FC adapter kit (includes C7529A and C7534A)
4-102 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Product Number Option Number Description VA7100 Factory Rack
A6261AZ Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 256-MB Cache A6262AZ Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 512-MB Cache (1×512MB DIMM) A6263AZ Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM) A6183AZ Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory
installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler panels for controllers
and disks. A6188A 0D1 Virtual Array Controller no memory installed A6185A 0D1 256-MB Cache for Virtual Array Controller, 1×256MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6186A 0D1 512-MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6187A 0D1 2×512MB Cache for Virtual Array Controller, 2×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6192A 0D1 36-GB 10K RPM FC HDD Module A6193A 0D1 36-GB 15K RPM FC HDD Module A6194A 0D1 73-GB 10K RPM FC HDD Module A7288A 0D1 73-GB 15K RPM FC HDD Module A6203A 0D1 Optical Gigabit Interface Circuit (GBIC) A3583A 0D1 2-meter FC fiber optic cable M/M multimode SC-SC A3531A 0D1 16-meter FC fiber optic cable M/M multimode SC-SC A3735A 0D1 50-meter FC fiber optic cable M/M multimode SC-SC A3736A 0D1 100-meter FC fiber optic cable M/M multimode SC-SC C7529A 0D1 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 0D1 16-meter FC fiber optic cable M/M duplex LC-SC C7534A 0D1 FC fiber optic coupler F/F SC-SC C7540A 0D1 FC adapter kit (includes C7529A and C7534A)
VA7100 Modules
A6183AE Field upgrade product. Select Virtual Array Controller (one or two) and cache product separately (factory installed).
Field Installed. Includes enclosure assembly, user manual, and 2 power supplies. This product is shipped without disks
or controllers/cache and includes filler for controllers and disks. A6261AE Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 256-MB Cache A6262AE Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 512-MB Cache (1×512-MB DIMM) A6263AE Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512-MB DIMM) A6188A Virtual Array Controller no memory installed A6185A 256-MB Cache for Virtual Array Controller, 1×256MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6186A 512-MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6187A 2×512MB Cache for Virtual Array Controller, 2×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6192A 36-GB 10K RPM FC HDD Module A6193A 36-GB 15K RPM FC HDD Module A6194A 73-GB 10K RPM FC HDD Module A7288A 0D1 73-GB 15K RPM FC HDD Module A6196A Deskside cabinet for HP StorageWorks VA7100 A6203A Optical Gigabit Interface Circuit (GBIC) A3583A 2-meter FC fiber optic cable M/M multimode SC-SC A3531A 16-meter FC fiber optic cable M/M multimode SC-SC A3735A 50-meter FC fiber optic cable M/M multimode SC-SC A3736A 100-meter FC fiber optic cable M/M multimode SC-SC C7529A 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 16-meter FC fiber optic cable M/M duplex LC-SC C7534A FC fiber optic coupler F/F SC-SC C7540A FC adapter kit (includes C7529A and C7534A)
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-103
Information Subject to Change
Chapter 4 Peripherals and Accessories
VA7100 Rail Kits
The following rail kits are needed to mount the VA7100 into the specific racks as listed.
Part Number Description
A6209A System/E Rail Kit (RoseBowl 2) A6496A NTRittal Rack rail kit A6244A HP Original rack rackmount hardware kit
VA7110 Hardware Ordering Information
The following codes define the suffixes on product numbers: A = Field Racked, AE = diskless enclosure (field disk integration), AZ = Factory Racked.
Order drives separately from the Enterprise Module section using the 0D1 option for integration. “AE” products are shipped as diskless enclosure only no integration (disks are ordered separately and field installed).
Product Number Option Number Description VA7110 Field RK SKU
A7294A Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM) A7296A Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 2048-MB Cache (2×1024MB DIMM) A7293A 0D1 Field upgrade product. Select Virtual Array Controller (two) and cache (minimum 1024 MB) and disk options separately
(factory installed). Includes filler for controllers and disks. (Note that single controller configurations are not
supported!) A6183AE Empty Enclosure A7293A 0D1 Virtual Array Controller no memory installed (Note that single controller configurations are not supported!) A6186A 0D1 1×512MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP A6187B 0D1 1×1024MB Cache for Virtual Array Controller, 1×1024MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP A6192A 0D1 36-GB 10K RPM FC HDD Module A6193A 0D1 36-GB 15K RPM FC HDD Module A6194A 0D1 73-GB 10K RPM FC HDD Module A7288A 0D1 73-GB 15K RPM FC HDD Module A7289A 0D1 146-GB 10K RPM FC HDD Module C7524A 0D1 Fiber Optic Cable 2-meter LC 50/125 M/M C7525A 0D1 Fiber Optic Cable 16-meter LC Duplex 50/125 M/M C7526A 0D1 Fiber Optic Cable 50-meter LC Duplex 50/125 M/M C7527A 0D1 Fiber Optic Cable 200-meter LC Duplex 50/125 M/M C7529A 0D1 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 0D1 16-meter FC fiber optic cable M/M duplex LC-SC C7534A 0D1 FC fiber optic coupler F/F SC-SC C7540A 0D1 FC adapter kit (includes C7529A and C7534A) VA7110 Factory Rack A7294AZ Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM) A7296AZ Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 2048-MB Cache (2×1024MB DIMM) A6183AZ 0D1 Field upgrade product. Select Virtual Array Controller (one or two) and cache (minimum 1024 MB) and disk options
separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler
panels for controllers and disks. A6186A 0D1 1×512MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP A6187B 0D1 1×1024MB Cache for Virtual Array Controller, 1×1024MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP A6192A 0D1 36-GB 10K RPM FC HDD Module A6193A 0D1 36-GB 15K RPM FC HDD Module A6194A 0D1 73-GB 10K RPM FC HDD Module A7288A 0D1 73-GB 15K RPM FC HDD Module A7289A 0D1 146-GB 10K RPM FC HDD Module C7524A 0D1 Fiber Optic Cable 2-meter LC 50/125 M/M
4-104 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Product Number Option Number Description
C7525A 0D1 Fiber Optic Cable 16-meter LC Duplex 50/125 M/M C7526A 0D1 Fiber Optic Cable 50-meter LC Duplex 50/125 M/M C7527A 0D1 Fiber Optic Cable 200-meter LC Duplex 50/125 M/M C7529A 0D1 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 0D1 16-meter FC fiber optic cable M/M duplex LC-SC
VA7110 Modules
A7294AE Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM) A7296AE Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 2048-MB Cache (2×1024MB DIMM) A6183AE Empty Enclosure A7293AE Virtual Array Controller no memory installed (Note that single controller configurations are not supported!) A6186A 1×512MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP
A6187B 1×1024MB Cache for Virtual Array Controller, 1×1024MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP A6192A 36-GB 10K RPM FC HDD Module A6193A 36-GB 15K RPM FC HDD Module A6194A 73-GB 10K RPM FC HDD Module A7288A 73-GB 15K RPM FC HDD Module A7289A 146-GB 10K RPM FC HDD Module A6203A Optical Gigabit Interface Circuit (GBIC) A3583A 2-meter FC fiber optic cable M/M multimode SC-SC A3531A 16-meter FC fiber optic cable M/M multimode SC-SC A3735A 50-meter FC fiber optic cable M/M multimode SC-SC A3736A 100-meter FC fiber optic cable M/M multimode SC-SC C7529A 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 16-meter FC fiber optic cable M/M duplex LC-SC C7534A FC fiber optic coupler F/F SC-SC C7540A FC adapter kit (includes C7529A and C7534A)
VA7110 Rail Kits
The following rail kits are needed to mount the VA7110 into the specific racks as listed.
Part Number Description
A6209A System/E Rail Kit (RoseBowl 2) A6496A NTRittal Rack rail kit A6244A HP Original rack rackmount hardware kit
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-105
Information Subject to Change
Chapter 4 Peripherals and Accessories
VA7410 Controller Enclosure Hardware Ordering Information
The following codes define the suffixes on product numbers: A = Field Racked, AE = Empty enclosure (no integration), AZ = Factory Racked.
Order drives separately from the Enterprise Module section using the 0D1 option for integration. “AE” products are shipped as diskless enclosure only no integration (disks are ordered separately and field installed).
Product Number VA7410 Enterprise Field RK SKU
A6267A VA7410 with Dual Controller 1024-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (1) DIMM
A6268A VA7410 with Dual Controller 2048-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (2) DIMM
A6187B 1 X 1024-MB Cache for Virtual Array Controller, 1 ×1024-MB DIMM, StorageWorks VAP requires equal cache for both
A6191A 0D1 Enterprise Class 18-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A6192A 0D1 Enterprise Class 36-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A6193A 0D1 Enterprise Class 36-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A6194A 0D1 Enterprise Class 73-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A7288A 0D1 Enterprise Class 73-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410 only) A7289A 0D1 Enterprise Class 146-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410
C7524A Fiber Optic Cable 2-meters LC 50/125 M/M C7525A Fiber Optic Cable 16-meters LC Duplex 50/125 M/M C7526A Fiber Optic Cable 50-meters LC Duplex 50/125 M/M C7527A Fiber Optic Cable 200-meters LC Duplex 50/125 M/M C7529A 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 16-meter FC fiber optic cable M/M duplex LC-SC C7534A FC fiber optic coupler F/F SC-SC C7540A FC adapter kit (includes C7529A and C7534A)
VA7410 Enterprise Factory Rack
A6267AZ VA7410 with Dual Controller 1024-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (1) DIMM
A6268AZ VA7410 with Dual Controller 2048-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (2) DIMM
A6187B 1 X 1024-MB Cache for Virtual Array Controller, 1 ×10242MB DIMM, StorageWorks VAP requires equal cache for both
A6191A 0D1 Enterprise Class 18-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A6192A 0D1 Enterprise Class 36-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A6193A 0D1 Enterprise Class 36-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A6194A 0D1 Enterprise Class 36-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A7288A 0D1 Enterprise Class 73-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410 only) A7289A 0D1 Enterprise Class 146-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410
C7524A Fiber Optic Cable 2-meters LC 50/125 M/M
Option Description
1,024-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit, RS-232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler panels for controllers and disks.
1,024-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit, RS-232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler panels for controllers and disks.
Controllers (if 2
only)
512-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit, RS­232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler panels for controllers and disks.
1024-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit, RS-232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler panels for controllers and disks.
Controllers (if 2
only)
nd
installed). Order 1 per installed VAP
nd
installed). Order 1 per installed VAP
4-106 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Product Number
C7525A Fiber Optic Cable 162-meters LC Duplex 50/125 M/M C7526A Fiber Optic Cable 502-meters LC Duplex 50/125 M/M C7527A Fiber Optic Cable 2002-meters LC Duplex 50/125 M/M C7529A 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 16-meter FC fiber optic cable M/M duplex LC-SC C7534A FC fiber optic coupler F/F SC-SC C7540A FC adapter kit (includes C7529A and C7534A)
VA7410 Enterprise Modules
A6267AE VA7410 with Dual Controller 1024-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (1) DIMM
A6268AE VA7410 with Dual Controller 2048-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (2) DIMM
A6187B 1×1024-MB Cache for Virtual Array Controller, 1×1024 2MB DIMM, StorageWorks VAP requires equal cache for both
A6218A VA7410 Controller (minimum two required for VA7410) A6191A Enterprise Class 18-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A6192A Enterprise Class 36-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A6193A Enterprise Class 36-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A6194A Enterprise Class 73-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) A7288A 0D1 Enterprise Class 73-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410 only) A7289A 0D1 Enterprise Class 146-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410
C7524A Fiber Optic Cable 2-meters LC 50/125 M/M C7525A Fiber Optic Cable 16-meters LC Duplex 50/125 M/M C7526A Fiber Optic Cable 50-meters LC Duplex 50/125 M/M C7527A Fiber Optic Cable 200-meters LC Duplex 50/125 M/M C7529A 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 16-meter FC fiber optic cable M/M duplex LC-SC C7534A FC fiber optic coupler F/F SC-SC C7540A FC adapter kit (includes C7529A and C7534A)
Option Description
512-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit, RS­232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler panels for controllers and disks.
1024-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit, RS-232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler panels for controllers and disks.
Controllers (if 2
only)
nd
installed). Order 1 per installed VAP
VA7410 Rail Kits
The following rail kits are needed to mount the VA7400 into the specific racks as listed.
Part Number Description
A6209A System/E Rail Kit (RoseBowl 2) A6496A NTRittal Rack Rail Kit A6244A HP Original rack rackmount hardware kit
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-107
Information Subject to Change
Chapter 4 Peripherals and Accessories
Disk System Enclosure (DS2405) Hardware Ordering Information
Note: The DS2405 cannot be used with the VA7100.
The following codes define the suffixes on product numbers: A = Field Racked, AE = Empty enclosure (no integration), AZ = Factory Racked.
Product Number DS2405 Disk Enclosure Field Rack
A6250A Disk System 2405 field rack enclosure (cables are not included and must be ordered separately) A6250AE Disk System 2405 field rack enclosure with no disk integration (cables are not included and must be ordered separately) A6192A 36-GB 10K RPM Fibre Channel drive add-on A6192A 0D1 36-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15) A6193A 36-GB 15K RPM Fibre Channel drive add-on A6193A 0D1 36-GB 15K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15) A6194A 73-GB 10K RPM Fibre Channel drive add-on A6194A 0D1 73-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15) A7288A 0D1 73-GB 15K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15) A7289A 0D1 146-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15, 7110 only)
DS2405 Disk Enclosure Factory Rack
A6250AZ Disk System 2405 factory rack enclosure (cables are not included and must be ordered separately) A6191A 0D1 18-GB 15K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15) A6192A 36-GB 10K RPM Fibre Channel drive add-on A6192A 0D1 36-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15) A6193A 36-GB 15K RPM Fibre Channel drive add-on A6193A 0D1 36-GB 15K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15) A6194A 73-GB 10K RPM Fibre Channel drive add-on A6194A 0D1 73-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15) A7288A 0D1 73-GB 15K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15) A7289A 0D1 146-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15, 7110 only)
Disk Enclosure Upgrades
A6209A System/E Rail Kit A6496A NTRittal Rack rail kit A6244A HP Original rack rackmount hardware kit
NOTES: A6183A requires rail kits to be ordered separately. Cache memory for VAP ordering note: You must order one and only one cache memory option type for each array. Fiber channel disk module ordering note: You must order at least two (2) but not more than fifteen (15) disk modules per enclosure. The unused slots must
contain a disk slot filler panel to insure proper cooling of the array. The factory will include filler panels for any remaining open drive bays.
DS2405 Disk System Accessories
C7524A 2-meter Fibre Channel cable LC 50/125 M/M C7525A 16-meter Fibre Channel cable LC Duplex 50/125 M/M C7526A 50-meter Fibre Channel cable LC Duplex 50/125 M/M C7527A 200-meter Fibre Channel cable LC Duplex 50/125 M/M C7529A 2-meter Fibre Channel cable LC/SC 50/125 M/M C7530A 16-meter Fibre Channel cable LC/SC 50/125 M/M C7540A Fiber optic adapter kit C7534A Fiber optic coupler SC F/F A6209A System/E rack rail kit A6244A HP Original rack rackmount hardware kit A6496A NT/Rittal rack rail kit A6498A 3U 2-post rail kit
Option Description
4-108 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
VA7000 Family Racking and Rail Kit Options
Note: Solution interconnect cabling/configuration of the A6264A/AZ and A6265A/AZ will be performed by the factory only when specified via Solution Integration Service Plan 2 (A3142B #002) with Visio Drawing attachment. Otherwise, data cables will ship with the solution, unconnected. (Please refer to http://www.sisp.hp.com for information on SISP services.). Not supported under Cronus structure
Note: The VA7100 is not designed to be transported in the RoseBowl 1 or Rittal racks.
HP Rack System/E Products
Part Number Description Height Units
A4900A HP Rack System/E25 1.25 meters 25U A4901A HP Rack System/E33 1.60 meters 33U A4902A HP Rack System/E41 1.96 meters 41U
Compaq 9000 Rack Products
Part Number Description Height Units
9122 Rack 1.1 meters 22U 9136 Rack 1.7 meters 36U 9142 Rack 2.0 meters 42U
Support Options Overview
Hardware Support Options
CATS Upfront Support Options for Enterprise; Product Support Packs for Commercial Channel
The following CATS and support pack options are available for the VA7000 Family. The support packs are on the disk system and contain the support pricing for the drives. CATS support, on the other hand, is ordered at the disk level. The following additional rules apply:
Installation and start-up service is required and includes the following on the entire customer order:
Pre-installation review
Hardware installation
Software enablement
LUN design and implementation
Customer documentation and orientation
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-109
Information Subject to Change
Chapter 4 Peripherals and Accessories
Direct (Enterprise) CATS and Options 1 Indirect (Commercial) Support Packs 1 VA Hardware Universal Product Numbers VA7100 Dual Controllers
A6261A/AZ/AE; A6262A/AZ/AE, A6263A/AZ/AE
VA7110 Dual Controllers
A7294A/AZ/AE; A7295A/AZ/AE; A7296A/AZ/AE
VA7410 Dual Controllers
A6267A/AZ/AE; A6268A/AZ/AE
Disk Enclosures A6214A/AZ/AE; A6183A/AZ/AE VA7100 Controller A6188A VA7110 Controller A7293A VA7410 Controller A6218A 18-GB HDD A6191A 36-GB HDD A6913A, A6192A 73-GB HDD A6194A 73-GB HDD A7288A 146-GB HDD A7289A
1
Direct channel (enterprise customers) purchase support on disks individually; support pack customers (“commercial” or indirect) receive coverage on up to 15 disks with
purchase of enclosure or dual controller support packs.
Note: CATS is the merger of the Camelot and Licensing 2000 projects into one overall program to “reinvent” HP’s upfront and contractual support structures. The internal program name is CATS, which stands for Camelot, Aries, Taurus, Scorpio (LS2K releases). For more information on CATS please see the URL at: http://nternet.fc.hp.com/catscore/channels.htm
HP Service levels CATS Support
Same Day N/A N/A N/A N/A N/A 24 hours × 7 days H4404A/H4405A H4405J H4404Y/H4405Y N/A N/A Storage Critical Support VA H4390A H4390J H4390Y H4390G H4390H BCS—4 hour Call-to-Restoration
Description 1-, 2-, and 3-year
Support: SD, 24×7, SCS, BCS
Covers dual processors, cache, enclosure
Covers dual processors, cache, enclosure
Covers dual processors, cache, enclosure
Covers enclosure 8AQ 5CA H7563A/E; H7564A/E H7558A/E
Covers processor, cache 803 5CE H7569A/E; H7570A/E H7552A/E
Covers processor, cache 803 5CF H7567A/E; H7553A/E H7552A/E
Covers processor, cache 803 5CF H7567A/E; H7553A/E H7552A/E
N/A 8AL 5CG N/A N/A
N/A 8AN 5CH N/A N/A
N/A 8AP 5CJ N/A N/A
N/A 8AP 5CJ N/A N/A
N/A 8AP 5CJ N/A N/A
Options-1 Year
H4395A N/A N/A N/A N/A
8AE 5CM H7555A/E; H7559A/E H7550A/E
8AF 5CP H7561A/E; H7565A/E H7551A/E
8AF 5CP H7561A/E; H7565A/E H7551A/E
CATS Support Options-2 Year
Installation and Start-Up (H4726A)
CATS Support Options-3 years
3-Year Support: SD, 24×7
CATS Support Options-4 Year
Installation and Start-Up
CATS Support Options-5 Year
4-110 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Hardware and Software—Additional Recommended Services
TAS—H4399A/H4399J/H4399Y
SAN Implementation Service for SAN environments—H9273A option 380, 381
Additional Day ASE Time—H9273A option 311
Service Guard Implementation—H4810AT
HP StorageWorks Business Copy VA Implementation (Virtual Array)—H9273A option 3B2
Contractual Support for Enterprise and Commercial Channels
Support Suffixes (SPNs)
02C 07A SL2
02A 07C SL3
02G 07G
02L 07V
02V 07X
02X
Description of Services Offered
The 02x are the post warranty support contractual monthly pricing available after the warranty. The 07x are the upgrade warranty support contractual monthly pricing available during the warranty.
Below are the Service Levels:
Code Description
02A On-site 4 hour same day hardware response, Monday - Friday, business hours. 07A 07A is available as a warranty upgrade to an 02A response level 02C On-site next day hardware response, Monday - Friday, business hours (vary by country). 07C 07C available as a warranty upgrade to an 02C response level 02G On-site 4 hour same day hardware response, seven days a week, 24 hours a day. 07G 07G available as a warranty upgrade to an 02G response level 02L On-site scheduled hardware response, Monday - Friday, business hours (vary by country). 02V On-site six-hour hardware call-to-repair, seven days a week, 24 hours a day. Time begins when the original call to the call center is
made. Recovery of operating system and other software are excluded from time commitment. Available only for customer sites up to
50 miles (80 km) from a primary HP Support Response Office. 07V 07V available as a warranty upgrade to an 02V repair level 02X On-site four-hour hardware call-to-restoration, seven days a week, 24 hours a day. Time begins when the original call to the call center
is made. Restoration considered complete when an operating system prompt is re-established and the operating system is restored to
the customer’s last configuration (or when the operating system is restored to a generic configuration for that operating system
configuration). Time commitment does not include time needed for recovery of middleware, application software or data. Available only
for customer sites up to 50 miles (80 km) from a primary HP Support Response Office. In order to purchase this level of response, the
system must be part of a BCS contract. 07X 07X available as a warranty upgrade to an 02X repair level SL2 8×5 Phone-in assistance (Monday – Friday), 2 hour response, License to Use and updates SL3 24×7 Phone-in assistance, 2 hour response, License to Use and Updates
Field Replaceable Units (FRUs)
Dual Inline Memory Modules (DIMMs)
Each controller utilizes one or two DIMMs, which contain battery-backed non-volatile RAM (NVRAM). The NVRAM is utilized for read/write caching and to store array memory maps. Because data is spread across all of the disks in the array, the array controller must have a way of determining where each block of data is located. This is accomplished using a logical-to-physical data map stored in NVRAM cache. This data map is vital to managing data; without it, all data in the array is inaccessible. Possible memory configurations are shown.
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-111
Information Subject to Change
Chapter 4 Peripherals and Accessories
In a dual controller configuration, both controllers must have the same amount of cache memory as the contents of NVRAM are mirrored between the two controllers. This mirroring process insures that both controllers have exactly the same information in the event of a failure. The controller battery maintains NVRAM contents when normal power is not present. If the battery fails or loses its charge while power is off, the NVRAM contents are lost on that controller. To protect against data loss, the array power/standby switch turns off power to the array and the “Shutdown Operation” copies NVRAM contents to the disk drives in slots 1 and 2 of the array. This allows reconstruction of the data in NVRAM if the original data is lost or corrupted.
Note: When upgrading a VA7400 to a VA7410 or a VA7100 to a VA7110 or a VA7410, both DIMMs need to be the same part number (A6186-60002, for example).
Note: The process of copying the contents of NVRAM to the two recovery disks makes the disk set independent of its controller. Because all the necessary mapping information is on these disks, it is possible to install a new controller or move the entire disk set to another controller. The new controller will determine that it has a new disk set, and the controller will attach itself to those disks.
DIMM Sizes and Cache Sizes
Array Minimum Cache Maximum Cache
VA7100 256-MB/controller 1024-MB/controller VA7110 1024-MB/controller 2048-MB/controller VA7410 1024-MB / controller 2048-MB / controller
Configurations of only one size DIMM in controllers are supported (for example, mixing 512-MB and 1024-MB DIMMs in the same controller is not supported).
Slot 1 DIMM (MB) Slot 2 DIMM (MB) Total Memory (MB) VA7100 VA7110 VA7410
256-MB – 256-MB Y N N 256-MB 256-MB 512-MB Y N N 512-MB – 512-MB Y N N 512-MB 512-MB 1024-MB Y Y* Y* 1024-MB – 1024-MB Y Y Y 1024-MB 1024-MB 2048-MB N Y Y * This is a supported configuration, but new VA7110 controllers will not ship with 512-MB DIMMs.
Battery
Each array controller includes one battery to supply backup power to the DIMMs in the event have a power failure or if array power is switched off. If power is lost, the BATTERY LED will flash with a 5% duty cycle while it powers the DIMMs. The battery will maintain a charge for 3.5 days. If the battery loses its charge, or if it is removed from the controller, the DIMMs have no power and NVRAM contents are lost. A battery should be replaced when the software indicates a battery has failed.
Early Warning Switch
In a dual controller configuration, the NVRAM contents on both controllers are updated constantly. By maintaining a mirror image of the NVRAM, the secondary controller can take over immediately if the primary controller fails. If a dual controller needs to be replaced online, an early warning switch incorporated into the latch detects when the controller is being removed. Releasing the latch disables communication between controllers before power is lost to the controller being removed. This prevents corruption of the NVRAM contents.
Disk Drives
The array must have a minimum of four disk drives installed. Several types of disk drives can be installed in the array and capacities can be mixed within the array:
18-GB Low-Profile Fibre Channel 15,000 rpm (supported, but no longer orderable)
36-GB Low-Profile Fibre Channel 10,000 rpm
36-GB Low-Profile Fibre Channel 15,000 rpm
73-GB Low-Profile Fibre Channel 10,000 rpm
73-GB Low-Profile Fibre Channel 15,000 rpm
146-GB Low-Profile Fibre Channel 10,000 rpm (VA7410 and VA7110 arrays only)
4-112 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
The disk drives provide the storage medium for the disk array. A minimum of four disk modules is required to operate the disk array. Different capacity disk modules can be installed in the same array. A new disk can be added at any time, even while the disk array is operating. The array controller will recognize that a new disk has been added and will include the disk in the array configuration automatically if the Auto Include feature is enabled. To make the additional capacity available to the host, a new logical drive must be created, and the resulting drive must be configured into the operating system.
Loading Rules
VA7100
Four (4) disks minimum and fifteen (15) disks maximum (4 of each type)
VA7110
Four (4) disks minimum and forty five (45) disks maximum (4 of each type)
VA7410 disk loading rules:
Ten (10) disk minimum per VA7410
One hundred and five (105) disks maximum
Four (4) disks minimum for each disk type that is installed, then user can add singles after that.
DS2405 (disk enclosure) disk loading rules:
Two (2) disk minimum
Fifteen (15) disk maximum per DS2405
Estimated Usable Capacity Tables
Estimated Usable Capacity for RAID 1+0—VA7100
This table lists the usable drive capacity, expressed in Gigabytes (GB), of the VA7100 with 36- and 73-GB drives with or without the use of hot spare drives.
Capacity Table 1 GB = (1024)3 for RAID 1+0
Drive size (GB) 36 GB 36 GB 73 GB 73 GB Hot Spares 2 0 2 0 Number of drives Maximum usable capacity
in GB 4 5 6 7 8 9 10 11 12 13 14 15
30.0 63.3 63.4 130.2
45.2 80.0 95.4 163.6
63.3 96.7 130.2 197.1
80.0 113.4 163.6 230.5
96.7 130.1 197.1 263.9
146.8 146.8 297.3 297.3
163.4 163.4 330.7 330.7
180.1 180.1 364.1 364.1
196.8 196.8 397.5 397.5
213.5 213.5 431.0 431.0
230.2 230.2 464.4 464.4
246.9 246.9 497.8 497.8
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-113
Information Subject to Change
Chapter 4 Peripherals and Accessories
Capacity Table (GB) 1 GB =1,000,000,000 or (10)
Drive size (GB) 36 GB 36 GB 73 GB 73 GB Hot Spares 2 0 2 0 Number of drives Maximum usable capacity
in GB 4 5 6 7 8 9 10 11 12 13 14 15
32.2 68.0 68.1 139.8
48.6 85.9 102.4 175.7
68.0 103.8 139.8 211.6
85.9 121.8 175.7 247.5
103.8 139.7 211.6 283.4
157.6 157.6 319.2 319.2
175.5 175.5 355.1 355.1
193.4 193.4 391.0 391.0
211.3 211.3 426.9 426.9
229.3 229.3 462.7 462.7
247.2 247.2 498.6 498.6
265.1 265.1 534.5 534.5
9
for RAID 1+0
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
Estimated Usable Capacity for AutoRAID—VA7100
This table lists the usable drive capacity, expressed in Gigabytes (GB), of the VA7100 with 18-, 36-, and 73-GB drives and with or without the use of hot spare drives.
Capacity Table 1 GB = (1024)3 for AutoRAID
Drive size (GB) 36 GB 36 GB 73 GB 73 GB Hot Spares 2 0 2 0 Number of drives Maximum usable capacity
in GB 4 5 6 7 8 9 10 11 12 13 14 15
30.0 63.3 63.4 130.3
45.2 93.4 95.5 192.6
63.3 123.0 130.3 252.7
93.4 153.9 192.6 314.4
123.0 184.6 252.7 375.9
153.9 215.2 314.4 437.3
184.6 245.7 375.9 498.4
215.2 276.3 437.3 558.9
245.7 306.7 498.4 620.6
276.3 337.2 558.9 681.7
306.7 367.6 620.6 742.6
337.2 398.0 681.7 803.5
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
Capacity Table (GB) 1 GB =1,000,000,000 or (10)9 for AutoRAID
Drive size (GB) 36 GB 36 GB 73 GB 73 GB Hot Spares 2 0 2 0 Number of drives Maximum usable capacity
in GB 4 5 6 7 8 9 10 11 12 13 14 15
32.16 68.0 68.1 139.9
48.56 100.4 102.5 206.8
67.99 132.2 139.9 271.3
85.91 165.4 206.8 337.6
103.83 198.4 271.3 403.6
157.58 231.3 337.6 469.5
175.50 264.1 403.6 535.2
193.42 296.9 469.5 600.1
211.34 329.6 535.2 666.4
229.26 362.4 600.1 732.0
247.17 395.1 666.4 797.4
265.09 427.7 732.0 862.8
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
4-114 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Estimated Usable Capacity for RAID 1+0—VA7110
This table lists the usable drive capacity, expressed in Gigabytes (GB), of the VA7110 with 36-, 73-, and 146-GB drives with or without the use of hot spare drives.
Capacity Table 1 GB
Drive size (GB) 36 GB 36 GB 73 GB 73 GB 146 GB 146 GB Hot Spares 2 0 2 0 2 0 Number of drives Maximum usable
capacity in GB 4 8 12 16 20 24 28 32 36 40 44 45
29 58 65 130 136 273
97 133 205 277 420 563
205 205 420 420 850 850
277 277 563 563 1137 1137
348 348 707 707 1423 1423
420 420 850 850 1710 1710
492 492 993 993 1997 1997
563 563 1137 1137 2284 2284
635 635 1280 1280 2570 2570
707 707 1423 1423 2857 2857
778 778 1567 1567 3144 3144
796 796 1603 1603 3215 3215
Estimated Usable Capacity for AutoRAID—VA7110
This table lists the usable drive capacity, expressed in Gigabytes (GB), of the VA7110 with 36-, 73-, and 146-GB drives and with or without the use of hot spare drives.
Capacity Table 1 GB
Drive size (GB) 36 GB 36 GB 73 GB 73 GB 146 GB 146 GB Hot Spares 2 0 2 0 2 0 Number of drives Maximum usable
capacity in GB 4 8 12 16 20 24 28 32 36 40 44 45
29 58 65 130 136 273
126 186 265 391 542 800
252 317 522 653 1036 1325
383 448 784 915 1587 1849
514 579 1046 1176 2110 2371
644 710 1307 1437 2632 2893
775 840 1568 1698 3154 3415
905 970 1829 1959 3676 3937
1036 1101 2089 2220 4197 4458
1166 1231 2350 2481 4719 4980
1296 1362 2611 2741 5240 5501
1329 1394 2676 2807 5371 5631
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
Maximum usable capacity in GB
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-115
Information Subject to Change
Chapter 4 Peripherals and Accessories
GBIC (VA7100 only)
A Gigabit Interface Converter (GBIC) is connected to each array controller as a transceiver for data and to convert the data from an optical signal to an electrical signal and vice versa. Each VAP includes a single GBIC. Based on user configurations, additional GBICs may be required. Only the GBICs A6203A (Enterprise) and A6241A (Commercial) are supported with the VA7100. These are Finisar GBICs, which provide readable serial number functionality.
Redundant Power Supply and Fan Modules
The array is shipped with two fully redundant power/fan modules. Each power/fan module contains:
One load-sharing power supply which works in conjunction with the second power supply. The power supplies share the power load reciprocally; one supply automatically increases its output to compensate for reduced output from the other. If one power supply fails, the other supply delivers the entire load to maintain power for the array. If both power supplies fail, the controller will shutdown the array. Each power supply uses a separate power cord. Both power supplies can be plugged into a common power source, but it is recommended that each supply be plugged into a separate circuit to provide power source redundancy.
Two internal fan modules provide cooling airflow and maintain the proper operating temperature for the entire array enclosure. If a fan fails, a fan fault will occur and the associated power supply will shut down. The other power supply will continue to operate and its associated fans will continue to cool the array. Also, if one power supply fails, both of its associated fans will continue to operate to cool the array.
Note: During normal operation, if a failed power supply/fan module is removed, it must be replaced within two minutes to maintain proper cooling of the array. If a power/fan module slot is left empty, the airflow path will be disrupted and the array will overheat.
Midplane
The midplane, internal to the array enclosure, contains the following features for the identification of the array. This information is stored into redundant EEPROMs during the manufacturing process:
Item Description
World Wide Name (WWN) The Node WWN is used by the OS drivers to identify the array enclosure. Default Fibre Channel Loop Addresses
Product Mode Parameters Retains various operating parameters Product Serial Number Same as the serial number sticker applied to the array Product ID Number VA7100 Same as the product ID number (A6188A) Product ID Number VA7110 Same as the product ID number (A7293A) Product ID Number VA7410 Same the product ID number (A6218A)
User installed licenses are stored within the Midplane EEPROM. These licenses are associated with a particular product serial number. If the Midplane must be replaced, a special Midplane may be ordered which, will allow the automatic regeneration of product serial number, licenses and product mode parameters. This information will be automatically re-programmed within the new Midplane EEPROMs if the replacement procedure is followed.
LED Status Indications
If a disk drive, controller, battery, DIMM, power supply or fan fails in the enclosure, a fault will be indicated by a fault (amber) LED on the module. The nature of the fault can be localized by examining the state of the LEDs.
The following default Fibre Channel loop addresses are assigned to array controllers: Array Controller 1: 108 Array Controller 2: 110
The default Fibre Channel loop addresses can be changed using either the Virtual Front Panel (VPF) or the Command Line User Interface (CLUI) included with your HP Command View SDM software.
NOTE: An array in a point-to-point configuration does not arbitrate for the bus, so no Fibre Channel loop addresses are required.
4-116 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Array Logs
The array logs consist of the following controller logs:
Events
Errors
Unexpected conditions
Configuration changes
Environmental changes
Fibre Channel Port Statistics
Historical Fibre Channel port information
Performance
Input/Output per second
Flash
Event log stored in flash memory in the event of a loss of battery power
The array logs are stored in two (2) locations: The Controller(s). Host operating system: The HP Command View SDM software polls the array controller every 15 minutes and updates a host OS directory located on the host server internal disk drive. These logs contain “Event” data will be commonly accessed by the support entity HP Response Center.
Note: The Fibre Channel Port Statistics and Performance log are stored in dynamic memory and will be lost when the array is powered off.
Supported Operating Systems
For Additional Information please see the Disk Storage Information located on the SPOCK web site: (http://hpso.rose.hp.com/spock/index.shtml#Disk_Storage_Information)
HP-UX
Windows NT
Windows 2000
Windows .NET (when available, VA7110 only)
Linux
Solaris—Requires management station
AIX—Requires management station
NetWare—Requires management station
MPE/iX—Requires management station; requires HP SCSI-FC router (A5814A option 003) for Fibre Channel
connectivity prior to MPE/iX 7.5; connectivity also supported via Native Fibre Channel in MPE/iX 7.5 or greater.
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership Website (external):
Spock Website:
For VA7100 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7100_docs.htm
For VA7110 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7110_docs.htm
For VA7410 array: http://nss-streams.corp.hp.com/xp_documentation/va7410_docs.htm
Partnership Website:
http://partner.americas.hp.com/
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-117
Information Subject to Change
Chapter 4 Peripherals and Accessories
Supported Hardware Devices
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership Website (external):
Spock Website:
For VA7100 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7100_docs.htm
For VA7110 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7110_docs.htm
For VA7410 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7410_docs.htm
Partnership Website:
http://partner.americas.hp.com/
HBA Support
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership Website (external):
Spock Website:
For VA7100 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7100_docs.htm
For VA7110 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7110_docs.htm
For VA7410 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7410_docs.htm
Partnership Website:
http://partner.americas.hp.com/
Hub Support
For the latest AutoPath support and configuration information, please refer to the SPOCK website (internal) or the Partnership Website (external):
Spock Website:
For VA7100 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7100_docs.htm
For VA7110 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7110_docs.htm
For VA7410 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7410_docs.htm
Partnership Website:
http://partner.americas.hp.com/
Hub HP-UX
10.20
S10/L10 Yes Yes Yes Yes Yes Yes None FCI 1063
HP-UX
11.00
HP-UX 11i
NT Advanced Server
NT Enterprise Edition
Windows 2000 Server
Windows 2000 Advanced Server
Linux Red Hat 6.2
AIX 4.3.3 (32- and 64-bit)
Solaris
2.6, 2.7,
2.8
and FC64-106 3 only
Netware
4-118 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Switch Support
For the latest AutoPath support and configuration information, please refer to the SPOCK website (internal) or the Partnership Website (external):
Spock Website:
For VA7100 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7100_docs.htm
For VA7110 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7110_docs.htm
For VA7410 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7410_docs.htm
Partnership Website:
http://partner.americas.hp.com/
Supported Disk Drives
Part Number Description All Operating Systems
A6191A 18-GB 15K RPM Yes A6192A 36-GB 10K RPM Yes A6193A 36-GB 15K RPM Yes A6194A 73-GB 10K RPM Yes A7288A 73-GB 15K RPM Yes A7289A 146-GB 10K RPM (VA7110 and VA7410 only) Yes
Supported Fibre Channel Cables
Product Number Description Usage Optical LC/LC
A3583A Fiber optic cable, SC to SC, M/M, 2-meters (79 in) VA7100 A3531A Fiber optic cable, SC to SC, M/M, 16-meters (52 ft) VA7100 A3735A Fiber optic cable, SC to SC, M/M, 50-meters (164 ft) VA7100 A3735A Fiber optic cable, SC to SC, M/M, 50-meters (164 ft) VA7100 C7524A FC Cable 2-meter LC Duplex 50/125 M/M optical SFF1 (VA7110, VA7400, VA7410) to SFF FC Infrastructure (2
GB/s FC)
C7525A FC Cable 16-meter LC 50/125 LC/LC M/M optical SFF1 (VA7110, VA7400, VA7410) to SFF FC Infrastructure (2
GB/s FC)
C7526A FC Cable 50-meter LC Duplex 50/125 M/M optical SFF1 (VA7110, VA7400, VA7410) to SFF FC Infrastructure (2
GB/s FC)
C7527A FC Cable 200-meter LC Duplex 50/125 optical SFF1 (VA7110, VA7400, VA7410) to SFF FC Infrastructure (2
GB/s FC)
LC/SC Adapters
C7529A FC Cable 2-meter LC/SC Duplex 50/125 M/M optical SFF1 (VA7400) to existing 1 GB/s FC Infrastructure C7530A FC Cable 16-meter LC/SC Duplex 50/125 LC/LC M/M optical SFF1 (VA7400) to existing 1 GB/s FC Infrastructure C7534A Fibre Channel SC F/F Extender Optical Converter for SFF cable to existing large format FC optical cables C7540A Fibre Channel Adapter Kit - optical (Includes the C7529A and
1
SFF = Small Form Factor
C7534A)
Kit for existing customer 1 GB/s FC infrastructure
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-119
Information Subject to Change
Chapter 4 Peripherals and Accessories
Configuration
Front End and Back End Cabling
Both front-end and back-end cables are Fibre Channel Optical cables.
Figure 4.7.10.8 VA7110 Back End Cabling (Serial Connections)
SC or SFF LC
Optical
Connectors
Switch or host Switch or host
SFF LC Optical
Connectors
Controller
4 ADDRESS
3
5
LCC
ACTIVE
2
6
LINK
LINK
LCC
PORT 0 PORT 1
ACTIVE
ACTIVE
FAULT
1
A6214-60001
0
ADDRESS4
3
5
6
2
1
0
FC-AL 100MB/s FC-AL 100MB/s
JBOD 1
4 ADDRESS
3
5
LCC ACTIVE
2
6
LINK
LINK
LCC
PORT 0 PORT 1
ACTIVE
ACTIVE
FAULT
1
A6214-60001
0
FC-AL 100MB/s FC-AL 100MB/s
ADDRESS4
3
5
6
2
1
0
ADDRESS4
3
LCC
5
ACTIVE
6
2
LINK
LINK
LCC
PORT 0 PORT 1
ACTIVE
ACTIVE
FAULT
1
A6214-60001
0
4
ADDRESS
3
5
6
2
1
0
FC-AL 100MB/s FC-AL 100MB/s
JBOD 2
Figure 4.7.10.9 VA7410 Back End Cabling (Serial Connections)
ADDRESS4
3
LCC
5
ACTIVE
6
2
LINK
LINK
LCC
PORT 0 PORT 1
ACTIVE
ACTIVE
FAULT
1
A6214-60001
0
FC-AL 100MB/s FC-AL 100MB/s
ADDRESS4
3
5
6
2
1
0
4-120 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Long-Distance Configurations (Not supported on MPE/iX)
Long-distance topologies are part of the supported configurations, but may not specifically be represented in this document. Long-distance scenarios may be obtained with the following configurations by replacing host/device connections with any of the combinations of hubs/switches as shown below. Hubs/switches may be cascaded no more than two layers deep and must meet the Fibre-Channel distance criteria (10,000- and 500­meter) for cables.
Figure 4.7.1.10 Long-Distance Substitutions
Hub/Switch
Long-distance cascaded hubs must
meet distance criteria and be no more
than two layers deep.
Hub/Switch
Hub/Switch
SAN Definitions
Configurations in this document that include a SAN assume the following definition of a SAN or fabric: A dedicated network of servers and storage devices all connected to a fabric supporting block access technologies. For the purposes of this document, a fabric is defined as a hardware configuration containing at least one switch, which is responsible for frame routing.
Open SAN is defined as heterogeneous (multiple vendor) servers and operating systems, heterogeneous storage, and heterogeneous infrastructure components. Pooled storage access is dependent on a LUN security methodology (zoning, partitioning, or dedicated LUN security) to provide data access by multiple heterogeneous servers. Multiple server access to common data is available only to homogeneous servers using server coordination software (e.g., MC/ServiceGuard for HP-UX and Cluster/iX for MPE/iX). Parallel server access is not supported on MPE/iX.
SAN Characteristics:
Utilizes a switch-based topology
Allows cascaded switches
Supports heterogeneous (multiple vendor) storage
Switch based
Heterogeneous server/OS capable
Heterogeneous (multiple vendor) storage
Fabric login
Uses LUN Security or zoning
Note: The SAN does not support common data access for heterogeneous servers.
SAN Manager (management software): Requires fabric login
Employs LUN Security or zoning
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-121
Information Subject to Change
Chapter 4 Peripherals and Accessories
Figure 4.7.1.11 Lowest Entry Point (Minimum Configuration)
MPE
Management
Station
No Multi-Path driver required
No hub or switch required
Windows/HP-UX/Linux and MPE supported
MPE requires Management Station
If SCSI-FC is required then use A5814A option 003 for VA7100 or VA7X10
Notes:
Care must be taken to when attaching a management station running NT or
Controller 1
VA71x0
Array
Controller 2
Windows 2000. Deny any requests for MS disk signatures. LUN Security can eliminate the risk of MS disk signatures.
Figure 4.7.1.12 Lowest Entry Point, Non-HA—Minimum Configuration (VA7410 only)
MPE
HBA
MPE
HBA
MPE
HBA
Management
Station
HBA
Single HBA per host
Dual controllers
Supports Windows 2000, HP-UX/Linux, and MPE
Requires LUN Security in a heterogeneous environment
CommandView SDM required on one of the hosts
If SCSI-FC is required then use
A5814A option 003 for VA7410
Controller 1
Up to 4 host optional
Controller 2
Array
Figure 4.7.1.13 Entry-level Cluster with Path Redundancy—High Availability (VA7410 only)
LUN Security recommended but not required
MPE MPE
HBA
HBA
Management
Station
Single HBA
Two controllers set up with both personalities
CommandView SDM required on the management station
Notes:
The VA7410 supports both 1 and 2 Gbps HBAs in the same host but the corresponding controller must be set to the same speed as the HBA (if the HBA does not support auto-negotiate). For example, if the HBA
Controller 1
VA71x0
Controller 2
is set to 2 Gbps, the connected controller must also be set to 2Gbps.
This configuration supports MPE’s Cluster/iX
Array
4-122 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Figure 4.7.1.14 Midrange Single-host with Failover/iX (unsupported for VA7100)
Chapter 4
Peripherals and Accessories
MPE
Management
Station
Dual HBA
Dual controllers
Dual switches recommended
MPE Failover/iX required (unsupported for VA7100)
Redundancy in storage paths
Management Station required
If SCSI-FC is required then use A5814A option 003 for VA7410
Note:
If routers are used then use Single Initiator Zoning on the switches
Controller 1
Switch
VA71x0
Controller 2
Array
Figure 4.7.1.15 Midrange Multi-host with Failover/iX (VA7410 only)
MPE
MPE
Management
Station
Switch Switch
Dual HBA Dual controllers Dual switches MPE Failover/iX required (unsupported for VA7100) Redundancy in storage paths Management Station required
Controller 1
VA71x0
Controller 2
Array
Figure 4.7.1.16 Simple Cluster with no Failover/iX (VA7410 only)
MPE
MPE
Management
Station
Controller 1
VA71x0
Controller 2
Array
If SCSI-FC is required then use A5814A option 003 for VA7410
Note:
If routers are used then use Single Initiator Zoning on the switches
Single HBA per host
Dual controllers
FC Switch
SCSI-FC Router (A5814A option 003)
SAN Manager software recommended
MPE Cluster/iX required
Management Station required
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-123
Information Subject to Change
Chapter 4 Peripherals and Accessories
SAN Configurations
Figure 4.7.1.17 Midrange Multi-host (Non-clustered) SAN with Optional Path Redundancy
MPE
MPE
MPE
Switch Switch
Controller 1
VA71x0
Controller 2
Array
Controller 1
VA71x0
Array
Figure 4.7.1.18 A Typical SAN Configuration
MPE
MPE
MPE
Switch
Management
Controller 2
Management
Station
Station
Dual HBA
Dual controllers
Dual switches
MPE Failover/iX required (unsupported for VA7100)
Redundancy in storage paths
Management Station required
If SCSI-FC is required then use A5814A option 003 for VA7410
Note:
If routers are used then use Single Initiator Zoning on the switches
Dual HBA
Dual controllers
Management Station required
LUN Security is recommended if unfamiliar with managing the
management station (disk signatures)
If SCSI-FC is required then use A5814A option 003 for VA7410
Note:
If routers are used then use Single Initiator Zoning on the switches
Controller 1
VA71x0
Controller 2
Array
Controller 1
VA71x0
Controller 2
Array
4-124 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Figure 4.7.1.19 MPE/iX SAN Cluster
Chapter 4
Peripherals and Accessories
MPE
MPE
Switch Switch
Controller 1
VA71x0
Controller 2
Array
Controller 1
VA71x0
Controller 2
Array
Figure 4.7.1.20 Heterogeneous Cluster in a SAN
HP-UX Server
dedicated LAN
connection
Windows
Server
Management
Station
dedicated LAN
connection
Dual HBA
Dual controllers
Dual switches
MPE Cluster/iX required (unsupported on VA7100)
Management Station required
If SCSI-FC is required then use A5814A option 003 for VA7410
Note:
If routers are used then use Single Initiator Zoning on the switches
Windows
Server
Not Supported
Switch Switch
1 2
VA7100
1 2
VA7100
HP-UX Server
Requires fabric login
Requires LUN Security support
Single or Dual HBA
Dual controllers
Requires multi-path driver
SAN Manager software recommended
Windows MSCS and MC/ServiceGuard
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-125
Information Subject to Change
Chapter 4
g
Peripherals and Accessories
Figure 4.7.1.21 SAN Consolidation
MPE
Server
Controller 1
Switch
VA71x0
Controller 2
Array
HP-UX
Server
Figure 4.7.1.22 Campus Cluster (Typical)
Cable/Connection Legend
SCSI HVD Fibre channel short-wave optical only LAN connection
HP-UX Server
Switch
VA71x0
Controller 1
Controller 2
Array
MPE
Server
Requires LUN Security
Single or Dual HBA
Controllers setup with appropriate personalities (not supported on VA7100)
Requires Failover/iX (MPE Not supported on VA7100)
Requires Management Station
If SCSI-FC is required then use A5814A option 003 for VA7XXX array
Note:
If routers are used then use Single Initiator Zoning on the switches
Additional
Nodes
Hub
or
Switch 1
1 2
Additional
Arrays
Building 1
Notes:
MPE/iX 7.0 Express 1 requires management station and HP SCSI-FC router (A5814A option 003) for Fibre Channel connectivity. Native Fibre Channel supported in MPE/iX 7.5 or greater.
Hubs and switches cannot be mixed in this configuration. They must be all hubs or all switches.
Metro Cluster and Continental Cluster are not supported.
For more details on Campus Cluster, please refer to Campus clusters http://haweb.cup.hp.com/LP/Documents/B7660-90006.pdf
Server
Node 1
Virtual Array 1
(7100 with
0-6 DS2400
Enclosures)
Hub
or
Switch 2
Server Node 2
Hub
or
Switch 3
1 2
Virtual Array 1
Switch 4
(7100 with
0-6 DS2400
Enclosures)
Hub
or
Additional
Nodes
Additional
Arrays
Buildin
2
Networks
4-126 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Software Product Descriptions
Software Products Reference Chart
The following table lists the software products available for the VA7000 Family. These products are described in detail later in this section.
Software Product Source Description
HP StorageWorks Command View SDM
HP StorageWorks Integrations Pack (Formerly Smart Plug-Ins)
HP StorageWorks Business Copy VA HP StorageWorks Secure Manager VA HP StorageWorks Auto Path Sold separately. Enables I/O path fail-over in a single server for MSCS Windows 2000, Windows NT, HP-UX
HP StorageWorks Fast Recovery Solutions
Software Products
Product Number Description
T1086A HP StorageWorks Command View SDM 1 host License To Use and software media kit. Device management for the HP StorageWorks
T1003A HP StorageWorks Secure Manager, 50-GB host License To Use and software media kit. (Required for enablement) (Not combinable -
T1004A HP StorageWorks Secure Manager 500-GB License To Use. T1005A HP StorageWorks Secure Manager 1-TB License To Use. T1006A HP StorageWorks Secure Manager 5-TB License To Use. T1007A HP StorageWorks Business Copy VA, 50-GB host License To Use and software media kit. (Required for enablement) (Not combinable -
T1008A HP StorageWorks Business Copy VA 500-GB License To Use. T1009A HP StorageWorks Business Copy VA 1-TB License To Use. T1010A HP StorageWorks Business Copy VA 5-TB License To Use. T1011A HP StorageWorks Auto Path for Windows 2000 1-host License To Use and software media kit. (Required for enablement) T1012A HP StorageWorks Auto Path for Windows 2000 - 1-host License To Use. T1013A HP StorageWorks Auto Path for Windows 2000 - 5-host License To Use. T1039A HP StorageWorks Auto Path for Windows NT 4.0 - 1-host License To Use and software media kit. (Required for enablement) T1040A HP StorageWorks Auto Path for Windows NT 4.0 - 1-host License To Use. T1041A HP StorageWorks Auto Path for Windows NT 4.0 - 5-host License To Use. T1060A HP StorageWorks Auto Path for HP-UX 11.0, 11i - 1-host License To Use and software media kit. (Required for enablement) T1061A HP StorageWorks Auto Path for HP-UX 11.0, 11i - 1 -host License To Use. T1062A HP StorageWorks Auto Path for HP-UX 11.0, 11i - 5-host License To Use. T1070A HP StorageWorks Auto Path for Windows Server 2003 - software media kit. (Required for enablement) T1071A HP StorageWorks Auto Path for Windows Server 2003 - 1 -host License To Use. T1072A HP StorageWorks Auto Path for Windows Server 2003 - 5-host License To Use. B9550A HP StorageWorks Fast Recovery Solutions for Microsoft Exchange 2000 1 array based license to use capacity unlimited B9551A HP StorageWorks Fast Recovery Solutions for Microsoft SQL 2000 1 array based license to use capacity unlimited
A single host license-to-use and software media kit ships with each VA7x00 Family product.
Included with Command View SDM.
Sold separately. Enables LUN copying within the array, and requires the same physical space to be available
Sold separately. Enables LUNs to be locked into a secure shared environment.
Sold separately. Allows for recovery of corrupted databases in minutes for Microsoft Exchange 2000 or SQL
VA7x00 Family.
50 GB max)
50 GB max)
Allows you to manage, diagnose, and monitor the performance of the array; used in conjunction with value-added software products. Native OS support on HP-UX, Windows NT, Windows 2000, Red Hat Linux, and with a separate management console on Solaris, Novell Netware, IBM AIX, and MPE. Additional host licenses must be purchased for each host running Command View SDM. Enables HP StorageWorks Command View SDM in HP OpenView NNM for HP-UX, Windows 2000 and Windows NT, also enables HP StorageWorks Command View SDM for HP TopTools, CA-Unicenter-TNG, Tivoli Netview and BMC Patrol. Includes/supports HP SEMI 1.0 for HP modular storage and tape devices.
in the array as the LUN(s) being copied.
and Linux environments.
2000 environments. Requires Business Copy Virtual array
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-127
Information Subject to Change
Chapter 4 Peripherals and Accessories
HP StorageWorks Command View SDM Software
The HP StorageWorks Command View SDM software is a host or Web-browser based device management application that provides a common user interface for modular networked storage systems.
The HP StorageWorks Command View SDM software monitors and manages modular scaleable storage resources from a single systems management console or remotely via a Web browser with centralized control of their information resources. The HP StorageWorks Command View SDM software launches and configures HP value added software, such as HP StorageWorks Business Copy VA and HP StorageWorks Secure Manager VA. The HP StorageWorks Command View SDM software supports the HP StorageWorks VA 7000 family.
Integrated device management platform and common user interface for all supported HP modular scaleable storage (arrays and disk systems)
Java technology for ease of portability for support of new storage devices
Active Graphic displays and status at glance features provides a comprehensive environment to monitor
health and status with the highest efficiency and awareness.
Common user interface (GUI, CLUI, CVUI and Web browser support) reduces training needs
Network management and SANs integration for SAN network connectivity and device identification and
event reporting to industry leading network management applications such as HP OpenView.
Heterogeneous support
HP StorageWorks Command View SDM Operating Systems Compatibility
For operating system compatibility, please see “Supported Operating Systems” on page 4-117.
HP StorageWorks Command View SDM Software Compatibility
HP StorageWorks Command View SDM
HP StorageWorks Integrations Pack
HP StorageWorks Secure Manager
HP StorageWorks Business Copy VA
HP StorageWorks Command View SDM Minimum System Requirements
Requires Internet Explorer 5.0; Netscape 4.74; Java Plug-In 1.3
Need to add installation requirements for RAM
Operating System CPU Memory Video Disk Space2
Windows NT 4.0 (SP 6a) Windows 2000 (SP 1) Windows Server 2003 (32-bit) HP-UX 11.0/11.11, 11.233 All 256 MB RAM 800×600 resolution,
Red Hat Linux 7.1, AS2.1 Pentium III 500 MHz 256 MB RAM 1024×768 resolution,
MPE/iX 1 Depends on management
Solaris 1 Depends on management
Novell Netware 1 Depends on management
IBM AIX 1 Depends on management
1
Requires dedicated management console and system requirements compatible with one of the above.
2
30 MB of temporary disk space is required during installation. This space is returned after installation.
3
HP-UX may require additional patches for proper operation.
Pentium III 500 MHz 256 MB RAM 1024×768 resolution,
supports 64,000 colors
supports 64,000 colors
supports 64,000 colors
station (see above).
station (see above).
station (see above).
station (see above).
Depends on management station (see above). Depends on management station (see above). Depends on management station (see above). Depends on management station (see above).
Depends on management station (see above). Depends on management station (see above). Depends on management station (see above). Depends on management station (see above).
120 MB of free disk space Performance Logs (2 months) 16 MB per LUN
120 MB of free disk space Performance Logs (2 months) 16 MB per LUN 120 MB of free disk space Performance Logs (2 months) 16 MB per LUN Depends on management station (see above). Depends on management station (see above). Depends on management station (see above). Depends on management station (see above).
4-128 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
The VA7x00 family system encompasses all the components within the controller chassis as well as the disks and their enclosures. The VA7x00 family Graphical User Interface (GUI) provides capabilities to retrieve single or multiple component status conditions and modify component states when applicable. The table lists all the components visible to the user. The first column denotes components that have their status queried and displayed by the GUI. The second column denotes components that the user can modify via the GUI.
Note: This is the Command Line User Interface (CLUI) that is used for the VA7000 Family.
Component Device Offerings
Component GUI provides capabilities to Query State GUI provides capabilities to Modify State
Main Enclosure Batteries Controllers DIMMs Disks Fans GBICs Power Supplies Ports JBODS Disks Fans LCC Power Supplies
3
This does not reflect changing state of the controller, but rather modifying controller parameters.
HP StorageWorks Command View SDM Frequently Asked Questions
What is included with the standalone version of HP StorageWorks Command View SDM? Each Standalone version of HP StorageWorks Command View SDM includes:
Software CD
User’s Manual
One Host License To Use
This is defined as “Installation Authorization for one (1) Server” running any or all of the Command View SDM components listed above.
Support is NOT INCLUDED with the Standalone version of HP StorageWorks Command View SDM. One (1) support option is required with each one (1) Host LTU of HP StorageWorks Command View SDM.
Do I need HP StorageWorks Command View SDM installed on all hosts in a configuration order to access my VA?
You must install HP StorageWorks Command View SDM on at least one (1) host with a fibre channel connection to the VA7100, VA7110 or VA7410. After your initial installation of HP StorageWorks Command View SDM, it is not necessary to install HP StorageWorks Command View SDM to access data on your VA.
Is HP StorageWorks Command View SDM only required for management/configuration purposes?
HP StorageWorks Command View SDM is only required for configuration and management of your HP VA. After your initial installation of HP StorageWorks Command View SDM, it is not necessary to install HP StorageWorks Command View SDM to access data on your VA.
How many VA’s can HP StorageWorks Command View SDM manage at any given time?
HP StorageWorks Command View SDM can manage an unlimited number of VA from a single host, provided that it is physically connected to each VA either directly or through a SAN
3
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-129
Information Subject to Change
Chapter 4 Peripherals and Accessories
HP StorageWorks Integrations Pack
HP StorageWorks Integrations Pack provide customers with a basic level of integration between HP StorageWorks Command View SDM and the leading network and systems management solutions enabling management from a single point—the enterprise management console. Integration is via SNMP (Simple Network Management Protocol) and enables customers to observe, diagnose and react to potential problems in their storage environment before they become serious enough to affect system availability.
HP StorageWorks Integrations Pack Features
Integration with HP OpenView NNM, HP TopTools, CA Unicenter-TNG, Tivoli Netview, and BMC Patrol
Includes/supports HP SEMI 1.0 agent for HP modular storage and tape devices
Plug and play installation
Automated custom scripts
Automatic discovery of supported storage devices by the network management application
Device event communication via SNMP for Windows 2000 and NT 4.0 environments
Changes in the status of the device are represented via the device icon that can launch the device software
for further diagnostics or configuration status.
Notes: HP StorageWorks Integrations Pack:
are only supported on HP StorageWorks Command View SDM for modular networked storage. They are not supported on XP arrays
do not support Red Hat Linux 6.2, 7.1.
HP StorageWorks Integrations Pack Compatibility
Supports HP SNMP integration for HP virtual arrays
Supports HP OpenView Network Node Manager for HP-UX, Windows NT 4.0, and Windows 2000.
Supports HP TopTools 4.5 and 5.0
Supports CA Unicenter TNG for HP-UX, NT 4.0, and Windows 2000
Supports HP StorageWorks VA7x00 Family
Supports Tivoli Netview
Supports BMC Patrol
Supports HP SEMI 1.0 agent for HP modular storage and tape devices
HP StorageWorks Integrations Pack Frequently Asked Questions
What is included with HP StorageWorks Integrations Pack?
Each HP StorageWorks Integrations Pack product includes:
Software CD
User’s Manual
One Host License To Use (LTU)
This is defined as “Installation Authorization for one (1) Server” running any or all of HP StorageWorks Integrations Pack components.
Support is not included with this product. One (1) support option is required with each one (1) Host LTU for Enterprise Integrations.
How does HP StorageWorks Command View SDM talk to OpenView Network Node-Manager using the HP StorageWorks Integrations Pack?
HP StorageWorks Command View SDM tracks each connected VA7000 family array using a unique TCP-IP address. HP StorageWorks Command View SDM gets device information from each virtual array inband through the fibre channel connection and the HP StorageWorks Integrations Pack translate this information to OpenView Network Node Manager over TCP-IP using JVM and standard SNMP commands.
4-130 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
HP StorageWorks Business Copy VA
HP StorageWorks Business Copy VA is an array-based software product that allows customers to create up to 1023 non-disruptive high-performance, local business copies of any active application volume or LUN for the VA7000 family array within the array while benefiting from full RAID protection for the business copies. These LUN copies can be used by another application or system for a variety of purposes, including batch processing and backup. You can create up to 1023 Business Copy LUNs with the VA7000 family arrays. Business Copy VA is fully integrated into and enabled through the HP Command View SDM software interface.
HP StorageWorks Business Copy VA is a vital piece of the Virtual Array Technology and is the key enabler of the virtual array online Backup solution, which is implemented using custom scripting of backup application environments.
HP StorageWorks Business Copy VA Features
Business critical data can be executed in parallel to enhance efficiency and cost effectiveness.
Instantly creating point-in-time copies of source LUNs, scheduling backup activities, and maintaining I/O
Host performance because all LUN creation and activity is handled directly by the array.
HP StorageWorks Business Copy VA is fully integrated with Command View SDM.
HP StorageWorks Business Copy VA Operating Systems Compatibility
HP StorageWorks Business Copy VA runs with HP StorageWorks Command View SDM. For operating system compatibility, please see “Supported Operating Systems” on page 4-117.
HP StorageWorks Business Copy VA Software Compatibility
HP StorageWorks Command View SDM
HP StorageWorks Integrations Pack
HP StorageWorks Secure Manager
HP StorageWorks Business Copy VA
HP StorageWorks Business Copy VA Minimum System Requirements
Operating System CPU Memory Disk Space
Windows NT 4.0 Windows 2000 Windows Server 2003 (32 bit) HP-UX 11.0, 11.11, 11.23 All 256 MB RAM 60 MB of free disk space. Red Hat Linux 7.1, AS2.1 Pentium III 500-MHz 256 MB RAM 45 MB of free disk space HP-UX 10.20 1 Depends on management station (see
MPE/iX 1 Depends on management station (see
Solaris 1 Depends on management station (see
Novell Netware 1 Depends on management station (see
IBM AIX 1 Depends on management station (see
1
Requires dedicated management console and system requirements compatible with one of the above.
Note: HP StorageWorks Business Copy VA supports a custom scripted implementation to automate backup solutions.
Pentium III 500-MHz 256 MB RAM 45 MB of free disk space.
above).
above).
above).
above).
above).
Depends on management station (see above). Depends on management station (see above). Depends on management station (see above). Depends on management station (see above). Depends on management station (see above).
Depends on management station (see above). Depends on management station (see above). Depends on management station (see above). Depends on management station (see above). Depends on management station (see above).
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-131
Information Subject to Change
Chapter 4 Peripherals and Accessories
HP StorageWorks Business Copy VA Frequently Asked Questions
What is included with HP StorageWorks Business Copy VA Software Media Kit?
Each HP StorageWorks Business Copy VA software media kit includes:
Software CD
User’s Manual
50-GB License To Use (not combinable - 50 GB max)
90 days of telephone support
In addition, to cover all capacity-based license-to-use options for HP StorageWorks Business Copy VA, one (1) support option is required.
How does HP StorageWorks Business Copy VA Licensing work?
In order to create HP StorageWorks Business Copy VA LUNs, a license must be obtained. Licensing is sold in quantities of 500 GB, 1 TB and 5 TB. The total size for all HP StorageWorks Business Copy VA LUNs cannot exceed the licensed amount for each virtual array.
HP StorageWorks Business Copy VA licensing is based on the total size of all parent LUNs being copied, not the total array capacity. For example, in an array with total usable capacity of two (2) Terabytes, if you are copying one (1) Terabyte of parent LUN data you must purchase a one (1) Terabyte HP StorageWorks Business Copy VA license.
Note: Licenses cannot span multiple arrays!
Every VA7000 series array contains a 50-GB trial license. This is a permanent capability of the array and is intended to allow the trial of the feature before committing to the purchase. The trial copy can be used for the life of the product. This trial license is NOT additive.
IS HP StorageWorks Business Copy VA supported for MPE/iX
No. There are no plans to support HP StorageWorks Business Copy VA on MEP/iX.
HP StorageWorks Secure Manager VA
HP StorageWorks Secure Manager VA is an array-based software product that allows customers to create up to 128 secure World Wide Name connections for the VA7000 family array on up to 1024 secure LUNs per virtual array. HP StorageWorks Secure Manager VA is fully integrated into and enabled through the HP Command View SDM software interface.
HP StorageWorks Secure Manager VA is a storage software application that allows LUNs to be locked into secure protected volumes by World Wide Names, ensuring that only authorized World Wide Names (WWN) have access to restricted volumes. Permissions for each principal can be configured by volume within the virtual array to read only, read/write, or no access. The HP StorageWorks Secure Manager VA software’s supported configurations range from an entry-level single-server direct-connect environment up to a homogeneous or heterogeneous clustered environment.
HP StorageWorks Secure Manager VA Features
World Wide Names, host, and volume to enhance efficiency and cost effectiveness can secure business critical data in parallel.
Configure security within the virtual array by changing permissions on volumes and/or World Wide Names (WWN) while the array is online.
Uses the HP StorageWorks Command View SDM interface for establishing secure volumes.
HP StorageWorks Secure Manager VA is fully integrated with HP StorageWorks Command View SDM and
the VA family of hardware and software products for interoperability across the spectrum of future virtual array storage solutions.
HP StorageWorks Secure Manager VA supports 128 secure World Wide Names for the VA7400. The HP StorageWorks Secure Manager VA software supports up to 1024 secure LUNs for each VA7000 family array.
4-132 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
HP StorageWorks Secure Manager VA Operating Systems Compatibility
HP StorageWorks Secure Manager VA runs with HP StorageWorks Command View SDM. For operating system compatibility, please see “Supported Operating Systems” on page 4-117.
HP StorageWorks Secure Manager VA Software Compatibility
HP StorageWorks Command View SDM
HP StorageWorks Integrations Pack
HP StorageWorks Secure Manager
HP StorageWorks Business Copy VA
HP StorageWorks Secure Manager VA Minimum System Requirements
Operating System CPU Memory Disk Space
Windows NT 4.0 and Windows 2000 HP-UX 11.0, 11.1 All 256 MB RAM 60 MB of free disk space. Red Hat Linux 6.2 Pentium III 500-MHz 256 MB RAM 45 MB of free disk space HP-UX 10.20 Depends on management station
Solaris 2.6, 7.0, 8.0 1 Depends on management station
Novell Netware 5.0,5.1 1 Depends on management station
IBM AIX 4.3.3 1 Depends on management station
1
Requires dedicated management console and system requirements compatible with one of the above.
HP StorageWorks Secure Manager VA Frequently Asked Questions
What is included with HP StorageWorks Secure Manager VA Software Media Kit?
Each HP StorageWorks Secure Manager VA software media kit includes:
Software CD.
User’s Manual.
50-GB License To Use (LTU).
90 days of telephone support.
In addition, one support option is required for each capacity-based license-to-use option for HP
StorageWorks Secure Manager VA.
What does the term “principal” mean when used in HP StorageWorks Secure Manager VA?
“Principal” and “World Wide Name” (WWN) are used interchangeably when describing secure connections for HP Virtual Arrays. All authentications for the VA7400 are based on WWN.
How many secure connections can each VA7000 family array support?
The VA7000 family array can support up to 128 secure Node WWN. Each Host Bus Adapter (HBA) uses a single Node WWN, therefore each VA7000 family array can support up to 1024 secure connections. Remember, for HA configurations, each server requires two HBAs so the largest HA configuration supported for each VA7000 family array is a 16-node cluster.
Can incremental capacity licenses be added over time?
Yes, licenses are cumulative and additional licenses to may be added as capacity needs grow.
HP StorageWorks Auto Path
HP StorageWorks Auto Path VA is host-based software that provides key data availability and performance. HP StorageWorks Auto Path provides multi-path failover capability of all I/O data paths to the virtual array. HP StorageWorks Auto Path offers completely automatic HBA failover for all supported cluster environments.
Pentium III 500-MHz 256 MB RAM 45 MB of free disk space.
(see above).
(see above).
(see above).
(see above).
Depends on management station (see above). Depends on management station (see above). Depends on management station (see above). Depends on management station (see above).
Depends on management station (see above).
Depends on management station (see above).
Depends on management station (see above).
Depends on management station (see above).
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-133
Information Subject to Change
Chapter 4 Peripherals and Accessories
Note: If a customer has met or is near the VA performance threshold, it is possible that high I/O demand (at 90% or greater of the VA threshold) may cause a performance degradation when running in a load­balancing configuration. Load balancing is not recommended for VA configurations that consistently require over 90% of the overall VA performance bandwidth!
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership Website (external):
Spock Website:
For VA7100 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7100_docs.htm
For VA7110 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7110_docs.htm
For VA7410 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7410_docs.htm
Partnership Website:
http://partner.americas.hp.com/
HP StorageWorks Auto Path Features
Automatic error detection and failover: helps eliminate the need for planned and unplanned downtime.
Works with Windows 2000 and Microsoft Cluster Server infrastructure.
Works with Windows NT 4.0 and Microsoft Cluster Server infrastructure
Works with HP-UX 11.0, 11i and MC/ServiceGuard infrastructure
Supports the HP VA products that provide maximum performance and scalability.
Automated configuration
Management through a graphical user interface
HP StorageWorks Auto Path Operating Systems Compatibility
Please see “Supported Operating Systems” on page 4-117.
HP StorageWorks Auto Path Software Compatibility
HP StorageWorks Command View SDM
HP StorageWorks Integrations Pack
HP StorageWorks Secure Manager
HP StorageWorks Business Copy VA
HP StorageWorks Auto Path Minimum System Requirements
Operating System CPU Memory Disk Space
Windows 2000, NT 4.0 Pentium III- 500 MHZ 256 MB RAM 45 MB of free disk space. HP-UX 11.0, 11i All 256 MB RAM 45 MB of free disk space.
Note: HP StorageWorks Auto Path provides automatic I/O path failover only for Windows 2000, NT 4.0, and HP-UX 11.0, 11i.
All HP software products are covered by a 90-day media defect warranty. All support options are sold separately.
HP StorageWorks Auto Path Frequently Asked Questions
What is included with HP StorageWorks Auto Path?
Each HP StorageWorks Auto Path product includes:
Software CD
User’s Manual
One (1) Host License To Use (LTU)
This is defined as “Installation Authorization for one (1) Server” running any or all Auto Path components.
Support is NOT included with this product. One (1) support option is required for each host-based license-to-use option for HP StorageWorks Auto Path.
4-134 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
What environments are available for HP StorageWorks Auto Path on the VA?
HP StorageWorks Auto Path has planned availability of Windows 2000, Windows NT, and HP-UX with Red Hat Linux planned for future availability.
HP StorageWorks Fast Recovery Solutions for Microsoft Exchange 2000 & SQL 2000
HP StorageWorks Fast Recovery Solutions (FRS) is a tool designed to enable fast recovery of corrupt Exchange 2000 or SQL 2000 databases. FRS interacts with Windows 2000, Exchange 2000 or SQL server, and the disk array. The disk array stages recovery ready copies of Exchange 2000/SQL 2000 databases. When a catastrophic event occurs, the Exchange administrator initiates the FRS process. This process takes the damaged database offline, removes it and inserts the known good, recovery-ready copy on the production server. This process recovers the known good copy from disk rather than tape providing a full database recovery in minutes not hours.
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership Website (external):
Spock Website:
For VA7100 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7100_docs.htm
For VA7110 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7110_docs.htm
For VA7400 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7400_docs.htm
For VA7410 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7410_docs.htm
Partnership Website:
http://partner.americas.hp.com/
HP StorageWorks Fast Recovery Solutions Features
Ultra-fast recovery of large Microsoft Exchange 2000 or SQL 2000 databases.
Lowest possible downtime during a corruption and database recovery.
Recovery to the last backup.
Multiple databases can be recovered simultaneously.
VA7000 Family Software Ordering Information
HP StorageWorks VA Software Support Products
Product Number Option Description
T1086A HP StorageWorks Command View SDM Software Media Kit with - 1 Host License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1002A HP StorageWorks Integrations Pack for HP StorageWorks Command View SDM
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service HP StorageWorks Secure Manager VA Software Media Kit and 50 GB License To Use (required for
enablement)
90-day support included (Not combinable - 50 GB max) H4403A/H4405A N/A H4403J/H4405J Two (2) year software support H4403Y/H4405Y N/A H4726A N/A T1004A HP StorageWorks Secure Manager VA 500 GB License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-135
Information Subject to Change
Chapter 4 Peripherals and Accessories
Product Number Option Description
H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1005A HP StorageWorks Secure Manager VA - 1TB License To Use-One (1) software support warranty option
required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1006A HP StorageWorks Secure Manager VA - 5 TB License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1007A HP StorageWorks Business Copy VA Software Media Kit and 50 GB License To Use (required for enablement)
90-day support included (Not combinable - 50 GB max) H4403A/H4405A N/A H4403J/H4405J Two (2) year software support H4403Y/H4405Y N/A H4726A N/A T1008A HP StorageWorks Business Copy VA 500 GB License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1009A HP StorageWorks Business Copy VA - 1 TB License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1010A HP StorageWorks Business Copy VA - 5 TB License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1011A HP StorageWorks Auto Path for Windows 2000 Software Media Kit and 1 Host License To Use (required for
enablement)
One software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1012A HP StorageWorks Auto Path for Windows 2000 - 1 Host License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1013A HP StorageWorks Auto Path for Windows 2000 - 5 Host License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support
4-136 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Product Number Option Description
H4726A Software enablement, installation and customer demonstration service T1039A HP StorageWorks Auto Path for Windows NT 4.0 Software Media Kit and 1 Host License To Use (required for
enablement)
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1040A HP StorageWorks Auto Path for Windows NT 4.0 - 1 Host License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1041A HP StorageWorks Auto Path for Windows NT 4.0 - 5 Host License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405J Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1042A HP StorageWorks Auto Path for Windows NT 4.0 - 10 Host License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1043A HP StorageWorks Auto Path for Windows NT 4.0 - 25 Host License To Use
One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1060A HP StorageWorks Auto Path for HP-UX 11.0,11i Software Media Kit and 1 Host License To Use (required for
enablement) One (1) software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1061A HP StorageWorks Auto Path for HP-UX 11.0,11i 1 Host License To Use One (1) software support warranty
option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1062A HP StorageWorks Auto Path for HP-UX 11.0,11i - 5 Host License To Use One (1) software support warranty
option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1070A HP StorageWorks Auto Path for Windows Server 2003 Software Media Kit (required for enablement) One (1)
software support warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1071A HP StorageWorks Auto Path for Windows Server 2003 1 Host License To Use One (1) software support
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-137
Information Subject to Change
Chapter 4 Peripherals and Accessories
Product Number Option Description
warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service T1072A HP StorageWorks Auto Path for Windows Server 2003 - 5 Host License To Use One (1) software support
warranty option required H4403A/H4405A One (1) year software support H4403J/H4405J Two (2) year software support H4405Y Three (3) year software support H4726A Software enablement, installation and customer demonstration service B9550A HP StorageWorks Fast Recovery Solutions for Microsoft Exchange 2000 1 Array-based License to Use,
capacity unlimited H4403A/H4405A One (1) year software support H4405Y Three (3) year software support B9551A HP StorageWorks Fast Recovery Solutions for Microsoft SQL 2000 1 Array-based License to Use, capacity
unlimited H4403A/H4405A One (1) year software support H4405Y Three (3) year software support
4-138 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Glossary
Abbreviation Description
Bps Bits per second BE Back End CLUI Command Line User Interface Cluster For the purposes of this document, a cluster is a configuration using two or more servers with failover capability. For
Cluster-Aware Application is aware of cluster environment, informs the user a cluster exists, and provides additional cluster information Cluster-Safe Application does not prevent a MSCS cluster certification and does not create loss of data in a MSCS cluster environment Cluster-Supported Application is a transferable resource in a cluster; i.e., if a node in a cluster is taken off-line, the application will failover
Data Center Version of Windows 2000 OS that allows clustering of up to four servers. DR Design Release ESI Enhanced Serial Interface ESN Enterprise Storage Network Fabric Login The name given to the initialization protocol for a device on the Storage Area Network (SAN) fabric with which it is
FE Front End Fsam Federated Storage Area Management GB Gigabyte(s) GBIC Gigabyte Interface Connector; plugged into the VA7100 controller to provide the optical interface to the host. Gbit Gigabit(s) (Note: HP standard says do not abbreviate as Gb.) GB/s Gigabits per second GHz Gigahertz GLM Gigabyte Link Module; generally associated with the HBA and the optical connection. GUI Graphical User Interface HBA Host Bus Adapter HCL Hardware Compatibility List Heterogeneous Dissimilar, differing in structure and quality JBOD Storage/RAID Device (just a bunch of disks) I/O Input/Output k Kilo (prefix meaning 1,024) K Kilo (prefix meaning 1,024) Kbit Kilobit (1,024 bits) (Note: HP standard says do not abbreviate as Kb.) KB Kilobyte (1,024 bytes) Kbps Kilobytes per second LUN Logical Unit Number (virtual disk) Mbit Megabit Mb/s Megabits per second MB Megabyte(s) MB/s Megabytes per second Windows MSCS Windows software that coordinates two servers and directs the other server to take over when one fails. Multi-path aware Ability to have knowledge of multiple paths to the storage device. Multi-path driver Device driver that masks multiple access paths to a physical device. Ability to switch between paths. RAID Redundant Array of Independent Disk Remote Management Capability Ability to launch management software from a remote location. RG Redundancy Group SAN Storage Area Network SCSI Small Computer Standard Interface SDM Storage Device Management SES SCSI Enclosure Services ServiceGuard HP-UX software that coordinates two servers and directs the other server to take over when one fails. SFF Small Form Factor VA Virtual Array VAP Virtual Array Controller WHQL Windows Hardware Quality Lab WWN World Wide Name Windows MSCS Microsoft Cluster Server - Windows software that coordinates two servers and directs the other server to take over
4.
HP-UX based configurations, this means running ServiceGuard. Windows-based cluster configurations incorporate the following characteristics: ·Windows Enterprise Edition for NT 4.0; Windows Advanced Server; Data Center Server for Windows 2000 (currently not released and not defined-this is an issue)
automatically to another cluster node.
“logged” into the SAN fabric. The act of “logging” provides the fabric with the required information about the device so that the device can be accessed and allows the device to access any other “fabric” device on the fabric.
when one fails.
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-139
Information Subject to Change
Loading...