HP VA7410, VA7110 User Manual

Chapter 4
Peripherals and Accessories
Subchapter 4.7—Disk Arrays
4.7.1—HP StorageWorks Virtual Array 7000 Family: VA7100, VA7110 and VA7410
The HP StorageWorks VA7000 Family arrays that support MPE/iX include the VA7100, VA7110 , and VA7410 arrays. Where sections are specific to a particular array, they are called out. If a section is not specifically called out, it is common to all.
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership Website (external):
Spock Website:
For VA7410 array: http://nss-streams.corp.hp.com/xp_documentation/va7410_docs.htm
For VA7100 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7100_docs.htm
For VA7110 array: http://xpslpgrms.corp.hp.com/xp_documentation/va7110_docs.htm
Partnership Website:
http://partner.americas.hp.com/
Enterprise Virtual Array (EVA)
For information on EVA support, please visit the following URLs:
For Installation and Configuration and Release Notes
In Spock, go to “Disk Array Connectivity” and select: HP StorageWorks EVA Technical Documentation
Go there directly with the following URL:
http://h18000.www1.hp.com/products/storageworks/enterprise/documentation.html
For Disk Array Connectivity
HP StorageWorks EVA Product Index
Go there directly with the following URL:
http://h18000.www1.hp.com/products/storageworks/enterprise/index.html
Overview
VA7100 Overview
The HP StorageWorks Virtual Array 7100 is a disk storage system that holds from 4 to 15 disk drives. The array has scalable capacities from 72 GB to 270 GB (211 GB usable) with all 18-GB disk drives and from 144 GB to 540 GB (428 GB usable) with all 36-GB disk drives and from 292 GB to 1.1 TB with 73-GB disk drives. Capacities and spindle speeds can also be mixed. The array requires a dual controller configuration to support MPE/iX. At least one controller must be attached to a management station running the HP StorageWorks Command View SDM software. Each controller has two DIMM slots available to hold NVRAM. The NVRAM is used for read/write caching and for storing array memory maps.
The Virtual Array 7100 can operate in either RAID 1+0 mode or AutoRAID mode, which eliminates the requirement for the system administrator to understand and configure RAID levels. AutoRAID dynamically adapts to the system’s workload, optimizing performance and cost. Users will find configuration significantly easier than other array products, since RAID levels don’t need to be configured or managed. The VA7100 supports one redundancy group, and all drives belong to that group. Using Virtual Storage Array (VSA) technology, when configured in AutoRAID mode the array controller automatically selects RAID 1+0 (disk striping and mirroring) or RAID 5DP (RAID 5 Double Parity) depending on the usage patterns of the data.
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-91
Information Subject to Change
Chapter 4 Peripherals and Accessories
RAID 5DP provides superior data redundancy by protecting against the simultaneous failure of two member disks by using independent error correction schemes.
The VA7100 is designed to communicate with multiple hosts and multiple systems, otherwise known as heterogeneous support. Any combination of the supported operating systems: HP-UX, MPE/iX, Windows NT, Solaris, AiX, NetWare, Windows 2000, and Linux can be used. Two different protocols, or host port behaviors, are used by the array to communicate with the operating systems: one protocol for Windows/Linux/other and another for HP-UX. Depending on the firmware level of the VA7100, another was added for MPE/iX. The Windows/Linux host port behaviors must be configured in the array for communication to take place with any or all four supported operating systems on a controller. When changing the port protocol to Windows/Linux it does support concurrent operation with Windows/Linux and HP-UX. The VA7100 provides simultaneous access by all of the supported operating systems on a LUN-by-LUN basis. Each LUN operates appropriately given the description of the operating system requirements.
The VA7100 can be configured to utilize an active hot spare feature. An active hot spare is a portion of the disk array capacity reserved to perform a rebuild. This feature requires the use of two additional disk units in the array. An active hot spare ensures that the disk array can maintain data redundancy if one or two disks fails. Until it is needed, the disk array uses the active hot spare storage space as RAID 1+0 capacity, which improves array performance. The active hot spare storage capacity does not sit idle; it is used to increase the disk array performance until the storage is needed.
The chassis will accommodate up to 15 low-profile 3.5-inch hard disk drives loaded from the front. The array requires 3 EIA units (3U) in height, which allows 10 units to be placed in a standard 1.6-meter rack. The rear of the 3 EIA rack mountable chassis also includes two 1-GB Fibre Channel controllers, dual power supplies and dual fan modules. The redundant power supply and fan components are combined into a single module. All modules are hot swappable.
The array can be connected to one or more hosts, hubs, or switches via an optical Fibre Channel (FC) interface with 1 gigabit per second transfer rates. It can be ordered in factory-racked, field-rackable, or desk-side configurations. Factory-racked products are pre-configured in the HP Rack/System E racks. Field-rackable products can be racked in HP racks or in Compaq 9000 racks.
The VA7100 is supported by HP’s Instant Support Enterprise Edition (ISEE). HP’s online diagnostic and resolution capability securely delivers remote reactive services that quickly resolve problems, proactive service that anticipate and prevent downtime due to computing issues, and value-added services to help monitor, manage and maintain global IT networks. A minimum level hardware support upgrade of same day is required. It is included with the VA for the first year (in addition to the warranty).
VA7110 Overview
The HP StorageWorks Virtual Array 7110 is a disk storage system that supports from four to 45 disk drives (two additional enclosures with 15 disks in each). The array has scalable capacities from 72 GB to 810 GB (211 GB usable) with all 18-GB disk drives and from 144 GB to 1.6 TB with all 36-GB disk drives and from 292 GB to 3.2 TB with 73-GB disk drives and from 584 GB to 6.5 TB with 146-GB disk drives. Capacities and spindle speeds can also be mixed. The array requires a dual controller configuration to support MPE/iX. At least one controller must be attached to a management station running the HP StorageWorks Command View SDM software. Each controller has two DIMM slots available to hold NVRAM. The NVRAM is used for read/write caching and for storing array memory maps.
The Virtual Array 7110 can operate in either RAID 1+0 mode or AutoRAID mode, which eliminates the requirement for the system administrator to understand and configure RAID levels. AutoRAID dynamically adapts to the system’s workload, optimizing performance and cost. Users will find configuration significantly easier than other array products, since RAID levels don’t need to be configured or managed. The VA7110 supports one redundancy group, and all drives belong to that group. Using Virtual Storage Array (VSA) technology, when configured in AutoRAID mode the array controller automatically selects RAID 1+0 (disk striping and mirroring) or RAID 5DP (RAID 5 Double Parity) depending on the usage patterns of the data. RAID 5DP provides superior data redundancy by protecting against the simultaneous failure of two member disks by using independent error correction schemes.
4-92 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
The VA7110 is designed to communicate with multiple hosts and multiple systems, otherwise known as heterogeneous support. Any combination of the supported operating systems—HP-UX, Windows NT, Solaris, AiX, NetWare, Windows 2000, MPE/iX, and Linux can be used. Two different protocols, or host port behaviors, are used by the array to communicate with the operating systems: one protocol for Windows/Linux/other and another for HP-UX. The Windows/Linux host port behaviors must be configured in the array for communication to take place with any or all four supported operating systems on a controller. When changing the port protocol to Windows/Linux it does support concurrent operation with Windows/Linux and HP-UX. The VA7110 provides simultaneous access by all of the supported operating systems on a LUN-by-LUN basis. Each LUN operates appropriately given the description of the operating system requirements.
The VA7110 can be configured to utilize an active hot spare feature. An active hot spare is a portion of the disk array capacity reserved to perform a rebuild. This feature requires the use of one or two additional disk units in the array. An active hot spare ensures that the disk array can maintain data redundancy if one or two disks fails. Until it is needed, the disk array uses the active hot spare storage space as RAID 1+0 capacity, which improves array performance. The active hot spare storage capacity does not sit idle; it is used to increase the disk array performance until the storage is needed.
Each enclosure will accommodate up to 15 low-profile 3.5-inch hard disk drives loaded from the front. The array requires three EIA units (3U) in height (per enclosure), which allows ten units to be placed in a standard
1.6-meter rack. The rear of the EIA rack mountable chassis also includes two 1-GB fibre channel controllers, dual power supplies and dual fan modules. The redundant power supply and fan components are combined into a single module. All modules are hot swappable.
The array can be connected to one or more hosts, hubs, or switches via an optical fibre channel (FC) interface with 1 or 2 gigabit per second transfer rates (the default setting is 1 gigabit). It can be ordered in factory-racked, field-rackable, or desk-side configurations. Factory-racked products are pre-configured in the HP Rack/System E racks. Field-rackable products can be racked in HP racks or in Compaq 9000 racks.
The VA7110 is supported by HP’s Instant Support Enterprise Edition (ISEE). HP’s online diagnostic and resolution capability securely delivers remote reactive services that quickly resolve problems, proactive service that anticipate and prevent downtime due to computing issues, and value-added services to help monitor, manage and maintain global IT networks. A minimum level hardware support upgrade of same day is required. It is included with the VA for the first year.
The revision numbering for firmware for the VA7110 has changed. The revision numbering now consists of a string of 4 ASCII characters (the HP designation has gone away). For example, a revision code of “X123” represents the following:
“X” is a single capital letter (A – Z) designating the platform
“1” is a single number or capital letter (0-9, A-Z) designating a major FW revision
“2” is a single number or capital letter (0-9, A-Z) designating a minor FW revision
“3” is a single number or capital letter (0-9, A-Z) designating a sub-minor FW revision
VA7410 Overview
The HP StorageWorks Virtual Array 7410 is a Fibre Channel (FC) disk storage system that supports from ten to 105 disk drives. The VA7410 has two FC ports on each controller. The VA7410 is comprised of two types of enclosures, each three EIA units high: the virtual array controller enclosure (A6183A/AZ) and the disk system enclosure (A6214A/AZ) also referred to as the disk enclosure or the JBOD (Just a Bunch Of Disks) enclosure. In addition, pre-defined SKUs are available to facilitate integrated arrays. The array consists of one controller enclosure and one to six disk enclosures, with scalable capacities from 181 GB to 1.90 TB (using 18-GB 15K rpm disk drives), 364 GB to 3.82 TB (using 36-GB 10K rpm disk drives), 720 GB to 7.67 TB (using 73-GB 10K rpm disk drives), or 1.46 TB to 15.33 TB (using 146-GB 10K rpm disk drives). Capacities and spindle speeds can also be mixed throughout the array.
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-93
Information Subject to Change
Chapter 4 Peripherals and Accessories
Both enclosures include dual power supplies with built-in dual blowers, and accommodate up to 15 low-profile
3.5-inch native fibre channel (FC) disk drives in the front. The controller enclosure also includes dual redundant 1 or 2-Gbps FC capable array controller cards and the disk enclosure also includes dual redundant 1- or 2-Gbps link controller cards for back-end connections to the controllers. All field replaceable units are hot swappable. The array controller cards, however, must be replaced offline if the OS does not support controller failover.
The VA7410 can operate in either RAID 1+0 mode or AutoRAID mode. These data protection levels are user selectable at the time of initial array installation. Using Virtual Storage Array (VSA) technology, when configured in AutoRAID mode the array controller automatically selects RAID 1+0 (disk striping and mirroring) or RAID 5DP (RAID 5 Double Parity) depending on the usage patterns of the data. This protection scheme eliminates the requirement for the system administrator to understand and configure RAID levels.
RAID 5DP provides superior data redundancy by protecting against the simultaneous failure of two member disks by using independent error correction schemes. Users will find configuration significantly easier than other array products, since RAID levels don’t need to be configured or managed. The VA7410 supports two redundancy groups, which provides for physical data path separation of the two groups of LUNS.
The VA7410 is architected to communicate with multiple hosts and operating systems, otherwise known as a simultaneous heterogeneous environment. For details on supported operating systems, please refer to the Spock Website and Partnership Website:
Spock website:
For VA7410 array: http://nss-streams.corp.hp.com/xp_documentation/va7410_docs.htm
For VA7400 array: http://nss-streams.corp.hp.com/xp_documentation/va7400_docs.htm
For VA7110 array: http://nss-streams.corp.hp.com/xp_documentation/va7110_docs.htm
For VA7100 array: http://nss-streams.corp.hp.com/xp_documentation/va7100_docs.htm
Partnership website:
http://partner.americas.hp.com/
One host port behavior is initially set in controller firmware, and then heterogeneous support for all other operating systems is enabled through software in a host port behavior table. The controller default host port behavior is set for HP-UX. The VA7xxx products are managed by the HP Command View SDM host-resident software. A one-host license to use for HP StorageWorks Command View SDM is included with each VA7410. Currently HP StorageWorks Command View SDM runs native on HP-UX, Windows NT, Windows 2000 and Red Hat Linux 6.2, 7.1. Installations on any of the other supported operating systems will require a dedicated management station running one of the aforementioned operating systems to be in the data path of the VA7410 (i.e. in the switched fabric).
The VA7410 can be configured to use an active hot spare feature. An active hot spare is a portion of the array capacity reserved to perform a rebuild. This feature requires the use of additional disk drives in the array. Users can select from 0, 1, or 2 active hot spares. An active hot spare ensures that the array can maintain data redundancy if one or two disks fail. Until it is needed, the array uses the active hot spare storage space as RAID 1+0 capacity, which improves array performance. The active hot spare storage capacity does not sit idle; it is used to increase the array performance until the storage it is needed.
The VA7410 can be connected to one or more hosts, hubs, or switches via an optical fibre channel (FC) interface with OS-dependant, 1- or 2-Gbps transfer rates. The default factory setting is 1-Gbps. It can be ordered in factory-racked and field-rackable configurations. Factory-racked products are pre-configured in the HP Rack/System E racks. Field-rackable products can be racked in HP racks or in Compaq 9000 racks.
The VA7410 is supported by HP’s Instant Support Enterprise Edition (ISEE). HP’s online diagnostic and resolution capability securely delivers remote reactive services that quickly resolve problems, proactive service that anticipate and prevent downtime due to computing issues, and value-added services to help monitor, manage and maintain global IT networks. A minimum level hardware support upgrade of same day is required.
4-94 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
New Firmware Revision Code Designation for VA7410
Note: The release firmware for the VA7410 is “A100”.
The revision numbering for firmware for the VA7410 has changed. The revision numbering now consists of a string of 4 ASCII characters (the HP designation has gone away). For example, a revision code of “X123” represents the following:
“X” is a single capital letter (A – Z) designating the platform
“1” is a single number or capital letter (0-9, A-Z) designating a major FW revision
“2” is a single number or capital letter (0-9, A-Z) designating a minor FW revision
“3” is a single number or capital letter (0-9, A-Z) designating a sub-minor FW revision
Important VA7410/DS2405 Notes:
On the VA7410 only the DS2405 is supported. For the VA7410, HP StorageWorks Command View SDM software version 1.05 or later is required.
Disk drive firmware may need to be upgraded. For more information, please check the Service Note server at the following site and do a search on the VA family via product numbers to see all available and relevant service notes: http://snserver.mayfield.hp.com/ServiceNotes/Snwebsite/SearchbyProdNum.asp
Additionally, on the DS2405, the LCC FC loop speed must be set to 2-Gbps (this is the factory default). If needed, refer to the DS2405 User Guide on setting LCC speed.
The DS2405 is not supported connected directly to a switch.
If you are upgrading to a VA7410 from an array with DS2400 JBODs, the DS2400 JBODs must also be
upgraded to DS2405 JBODs.
Product Features
Integrated VA arrays contain two (2) controllers. The array controllers contain the intelligence and functionality required to manage the operation of the entire array. The array functions include:
Implementing HP Virtual Storage Technology to ensure optimum performance and cost-efficient data storage
Managing all communication between the host and the disk drives via single or dual controller Fibre Channel arbitrated loops
Maintaining data integrity by automatically correcting any data errors that occur
Rebuilding the array in the event of a disk failure
Monitoring the operation of all hardware components, including the controller itself
Alerting the host in the event of a component failure
The use of two controllers protects the array against a single controller failure. Both controllers may be active, allowing a possible increase in performance, while providing data redundancy.
Each configured array controller includes the following components:
One (1) or two (2) Dual Inline Memory Modules (DIMMs), purchased separately if an additional Virtual Array Controller is added
One (1) Battery
One (1) Early Warning Switch
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-95
Information Subject to Change
Chapter 4 Peripherals and Accessories
Performance, Throughput and Capacity
Item Value
Throughput Host Interface VA7100 100 MB/s FC Throughput Host Interface VA7110 200 MB/s FC Throughput Host Interface VA7400 200 MB/s FC Throughput Host Interface VA7410 200 MB/s FC Drive Interface 100 MB/s FC Disk System Capacity VA7100 1095 GB raw capacity Disk System Capacity VA7110 6.5 TB raw capacity Disk System Capacity VA7400 7.6 TB GB raw capacity Disk System Capacity VA7410 15.3 TB GB raw capacity Storage Controller High-performance Virtual Array Controller Disk Drive Capacity 18 GB, 36.4 GB 73 GB and 146 GB (Note the 146 GB drive is for the VA7110 only Rotational Velocity 10K RPM and 15K RPM Disk Drive Transfer Rate 10K = 26 MB/s (or better); 15K = 38 MB/s (or better) Disk Drive Average Seek Time 10K = 4.7 ms (or better) Read, 5.2 ms (or better) Write; 15K = 3.6 ms (or better) Read, 4.2 ms (or better) Write Disk Drive Average Latency 10K = 2.99 ms, 15K = 2.00 ms
VA7110 Disk Enclosure Specifications (DS2405)
Physical Specifications
Height Width Depth Net Weight Max Shipping Weight Max
5 in 17.6 in 20 in 84.5 lbs 101.5 lbs 128 mm 448 mm 508 mm 38.3 kg 46 kg
Electrical Specifications
Parameter Value
Voltage (Auto-Ranging) 100-127 VAC; 200-240 VAC Frequency 50/60 Hz Current (Maximum; 2 power inputs) 8.2 A @ 100 VAC, 3.4 A @ 200 VAC Inrush Current (Peak) 3.92 A @ 269 VAC Power Consumption 473 W @ 120 VAC, 457 W @ 240 VAC Heat Dissipation 1443 BTU/hr VA Rating (Maximum Configuration) 473 VA @ 120 VAC, 457 VA @ 240 VAC
Environmental Specifications
Parameter Operating Range Recommended Range Non-Operating
Temperature 5° to 35° C (41° to 95° F) 20° to 25.5° C (68° to 78° F) –40° to 70° C (-40° to 158° F) Temperature Gradient 20° C (36° F) per hour 20° C (36° F) per hour 20° C (36° F) per hour Relative Humidity (Non-Condensing) 15% to 80% @ 28° C (dry bulb) 30% to 50% @ 28° C (dry bulb) 5% to 95% @ 65° C (149° F) Shock 4 g, 11 ms (20 low-impulse pulses) N/A 20 g, 30 ms trapezoidal
(non-transport) 1-inch edge drops per side (transport)
Vibration 0.21 g rms, 5- to 500-Hz random N/A 2.09 g rms, 5- to 500-Hz random
0.5 g peak, 5- to 500-Hz swept sine Altitude 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 15,000 ft (0 to 4,572 m) Acoustic (ISO 9296) 8.0 bels 8.0 bels N/A
Regulatory Compliance
Parameter Specification
Radiated and Conducted Emissions FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998 Immunity EN 55024: 1998/CISPR-24: 1997 Harmonic Current IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14 Voltage Fluctuations and Flicker IEC 61000-3-3: 1994/EN 61000-3-3: 1995 Product Safety EN 60950: 1991, Second Edition + A1, A2, A3, and A4
CAN/CSA - C22.2 No. 60950-00, Third Edition UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11 Class 1 (Laser/LED) GB4943: 1995
4-96 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Warranty
Included with every VA7000 Family Array:
Warranty: 2-year, 8×5, same-day, 4-hour on-site response for hardware with a 2-year 8×5 phone-in assistance, 2-hour response for HP StorageWorks Command View SDM phone-in assistance (PIA)
Required with purchase:
VA Family Hardware and Software: Installation service—H4726A
Pre-installation review
Hardware installation
Software enablement
LUN Design and Implementation
Customer documentation and orientation
VA Family Software: 8×5 Phone-in-Assistance (H4403A, Support Pack)
Instant Support Enterprise Edition Support (ISEE)
What is Instant Support Commercial
HP Instant Support is a unique combination of web-based self-service diagnostics and knowledge base access and is offered as a free value-added service for HP desktop computers, mobile computers, technical workstations, and PC servers.
ISC Value Proposition
HP Instant Support automates and speeds the resolution of computing problems, freeing customers from time-consuming diagnostic chores and returning them to more productive business-critical tasks.
Links of Interest
Instant Support Commercial (European server)—
http://instantsupport.europe.hp.com/motivedocs/hpinstantsupport.html
www.hp.com/go/instantsupport
Instant Support (desktop/printers)—WW Marketing Page http://www.hp.com/go/instantsupport
HPCS eDelivery EMEA—http://hpsedelivery.europe.hp.com/
HP Business Support—http://h20000.www2.hp.com/bizsupport/index.jsp
Troubleshooting Resources—http://www.hp.com/hps/itsol/suppt_troubleshooting.html
Specifications
VA7100 Specifications
Racked Product Physical Specifications
Height Width Depth Net Weight Minimum
5.0 in 17.6 in 26 in 75 lbs 128 mm 448 mm 660 mm 34 kg
Deskside Product Physical Specifications
Height Width Depth Net Weight Minimum
19 in 16.5 in (box (6.5) + base (10) 26 in 105 lbs 483 mm 419 mm 660 mm 47.6 kg
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-97
Information Subject to Change
Chapter 4 Peripherals and Accessories
Deskside and Racked Product Electrical Specifications (VA7100 only)
Parameter Value
Voltage 100-127 and 200-240 VAC (auto-ranging) Frequency 50/60 Hz Current (Maximum) 7.2 Amps RMS (2 power inputs) Inrush Current (Peak) 36 Amps Power Consumption 670 Watts Heat Dissipation 196 BTU VA Rating (Maximum Configuration) 720 VA
Deskside/Racked Product Environmental Specifications
Parameter Operating Range Recommended Range Non-Operating
Temperature 5° to 35° C 20º C to 25.5º C (68º F to 78º F) –40° to 70° C Temperature Gradient 20° C (36° F) per hour 20° C (36° F) per hour 20° C per hour Relative Humidity (non-condensing) 10% to 80% @ 28° C (wet bulb) 30% to 50% @ 28° C (wet bulb) 10% to 90% @ 28° C (wet bulb) Shock 4 g, 11 ms half sine N/A 4 g, 11 ms half sine Vibration 0.21g rms, 5- to 500-Hz random N/A 2.09 g rms, 5- to 500-Hz random
0.5-g peak, 5- to 500-Hz swept sine Altitude 0 ft to 10,000 ft 0 ft to 10,000 ft 0 ft to 15,000 ft Acoustic (ISO 9296) 8.0 bels 8.0 bels N/A
Deskside/Racked Product Regulatory Compliance
Parameter Specification
Radiated and Conducted Emissions FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998 Immunity EN 55024: 1998/CISPR-24: 1997 Harmonic Current IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14 Voltage Fluctuations and Flicker IEC 61000-3-3: 1994/EN 61000-3-3: 1995 Product Safety EN 60950: 1991, Second Edition + A1, A2, A3, and A4
CAN/CSA - C22.2 No. 60950-00, Third Edition UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11 Class 1 (Laser/LED) GB4943: 1995
VA7110 and VA7410 Controller Enclosure Specifications
Physical Specifications
Height Width Depth Net Weight Max Shipping Weight Max
5 in 17.6 in 26 in 34 lbs 130.1 lbs 128 mm 448 mm 660 mm 41.8 kg 59.0 kg
Electrical Specifications
Parameter Value
Voltage (Auto-Ranging) 100-127 VAC, 200-240 VAC Frequency 50/60 Hz Current (Maximum; 2 power inputs) 8.2 A @ 100 VAC, 3.6 A @ 200 VAC Inrush Current (Peak) 36 A Power Consumption 670 W Heat Dissipation 196 BTU/hr VA Rating (Maximum Configuration) 720 VA
4-98 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Environmental Specifications
Parameter Operating Range Recommended Range Non-Operating
Temperature 5° to 35° C (41° to 95° F) 20º to 25.5º C (68º to 78º F) –40° to 70° C (-40° to 158° F) Temperature Gradient 20° C (36° F) per hour 20° C (36° F) per hour 20° C (36° F) per hour Relative Humidity 15% to 80% @ 28° C (dry bulb) 30% to 50% @ 28° C (dry bulb) 10% to 90% @ 28° C (dry bulb) Shock 4 g, 11 ms half sine N/A 4 g, 11 ms half sine Vibration 0.21 g rms, 5- to 500-Hz random N/A 2.09 g rms, 5- to 500-Hz random
0.5 g peak, 5- to 500-Hz swept sine Altitude 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 15,000 ft (0 to 4,572 m) Acoustic (ISO 9296) 8.0 bels 8.0 bels N/A
Regulatory Compliance
Parameter Specification
Radiated and Conducted Emissions FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998 Immunity EN 55024: 1998/CISPR-24: 1997 Harmonic Current IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14 Voltage Fluctuations and Flicker IEC 61000-3-3: 1994/EN 61000-3-3: 1995 Product Safety EN 60950: 1991, Second Edition + A1, A2, A3, and A4
CAN/CSA - C22.2 No. 60950-00, Third Edition UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11 Class 1 (Laser/LED) GB4943: 1995
DS2405 Disk Enclosure Specifications
Physical Specifications
Height Width Depth Net Weight Max Shipping Weight Max
5 in 17.6 in 20 in 84.5 lbs 101.5 lbs 128 mm 448 mm 508 mm 38.3 kg 46 kg
Electrical Specifications
Parameter Value
Voltage (Auto-Ranging) 100-127 VAC; 200-240 VAC Frequency 50/60 Hz Current (Maximum; 2 power inputs) 8.2 A @ 100 VAC, 3.4 A @ 200 VAC Inrush Current (Peak) 3.92 A @ 269 VAC Power Consumption 473 W @ 120 VAC, 457 W @ 240 VAC Heat Dissipation 1443 BTU/hr VA Rating (Maximum Configuration) 473 VA @ 120 VAC, 457 VA @ 240 VAC
Environmental Specifications
Parameter Operating Range Recommended Range Non-Operating
Temperature 5° to 35° C (41° to 95° F) 20° to 25.5° C (68° to 78° F) –40° to 70° C (-40° to 158° F) Temperature Gradient 20° C (36° F) per hour 20° C (36° F) per hour 20° C (36° F) per hour Relative Humidity (Non-Condensing) 15% to 80% @ 28° C (dry bulb) 30% to 50% @ 28° C (dry bulb) 5% to 95% @ 65° C (149° F) Shock 4 g, 11 ms (20 low-impulse pulses) N/A 20 g, 30 ms trapezoidal
(non-transport) 1-inch edge drops per side (transport)
Vibration 0.21 g rms, 5- to 500-Hz random N/A 2.09 g rms, 5- to 500-Hz random
0.5 g peak, 5- to 500-Hz swept sine Altitude 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 10,000 ft (0 to 3,048 m) 0 ft to 15,000 ft (0 to 4,572 m) Acoustic (ISO 9296) 8.0 bels 8.0 bels N/A
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-99
Information Subject to Change
Chapter 4 Peripherals and Accessories
Regulatory Compliance
Parameter Specification
Radiated and Conducted Emissions FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998 Immunity EN 55024: 1998/CISPR-24: 1997 Harmonic Current IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14 Voltage Fluctuations and Flicker IEC 61000-3-3: 1994/EN 61000-3-3: 1995 Product Safety EN 60950: 1991, Second Edition + A1, A2, A3, and A4
CAN/CSA - C22.2 No. 60950-00, Third Edition UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11 Class 1 (Laser/LED) GB4943: 1995
Figure 4.7.1.1 HP StorageWorks Virtual Array 7000 Family – Front View
Figure 4.7.1.2 HP StorageWorks Virtual Array 7100
Figure 4.7.1.3 HP StorageWorks Virtual Array 7100—Deskside Configuration
4-100 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Figure 4.7.1.4 VA7100—Rear View
Array
Controller
Fibre
Channel
Port
Array
Controller
LEDs
Chapter 4
Peripherals and Accessories
RS-232
Serial
Port
AC Power
Connection
Power
Supply
Figure 4.7.1.5 StorageWorks VA7110—Front and Rear View
43
65
10
13
Array
Controller
LEDs
Figure 4.7.1.6 VA7410—Rear View
Array
Disk PortsFCHost Ports
Controller
Card 1
1 2 1 2
8
7
A 8 1 2 6 A
9
host 2disk 2
FC
11
15
RS-232
Connector
Power
Supply
LEDs
12
A 8 1 2 6 A
1
2
2
hostdisk
1614
Array
Controller
Card 2
AC Power
Connection
Power
Module 1
Power
Module LEDs
Power
Module 2
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-101
Information Subject to Change
Chapter 4 Peripherals and Accessories
Figure 4.7.1.7 StorageWorks DS2405—Rear View
Array
Disk PortsFCHost Ports
Controller
Card 1
1 2 1 2
FC
Array
Controller
LEDs
RS-232
Connector
Array
Controller
Card 2
AC Power
Connection
Power
Module 1
Power
Module LEDs
Power
Module 2
Hardware Ordering Information
VA7100 Hardware Ordering Information
The following codes define the suffixes on product numbers: A = Field Racked, AE = diskless enclosure (field disk integration), AZ = Factory Racked.
Order drives separately from the Enterprise Module section using the 0D1 option for integration. “AE” products are shipped as diskless enclosure only no integration (disks are ordered separately and field installed).
Product Number Option Number Description VA7100 Field RK SKU
A6261A Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 256-MB Cache A6262A Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 512-MB Cache (1×512MB DIMM) A6263A Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM) A6183A Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory
installed). Includes filler for controllers and disks. A6188A 0D1 Virtual Array Controller no memory installed A6185A 0D1 256-MB Cache for Virtual Array Controller, 1×256MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6186A 0D1 512-MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6187A 0D1 2×512MB Cache for Virtual Array Controller, 2×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6192A 0D1 36-GB 10K RPM FC HDD Module A6193A 0D1 36-GB 15K RPM FC HDD Module A6194A 0D1 73-GB 10K RPM FC HDD Module A7288A 0D1 73-GB 15K RPM FC HDD Module A6203A 0D1 Optical Gigabit Interface Circuit (GBIC) A3583A 0D1 2-meter FC fiber optic cable M/M multimode SC-SC A3531A 0D1 16-meter FC fiber optic cable M/M multimode SC-SC A3735A 0D1 50-meter FC fiber optic cable M/M multimode SC-SC A3736A 0D1 100-meter FC fiber optic cable M/M multimode SC-SC C7529A 0D1 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 0D1 16-meter FC fiber optic cable M/M duplex LC-SC C7534A 0D1 FC fiber optic coupler F/F SC-SC C7540A 0D1 FC adapter kit (includes C7529A and C7534A)
4-102 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Product Number Option Number Description VA7100 Factory Rack
A6261AZ Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 256-MB Cache A6262AZ Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 512-MB Cache (1×512MB DIMM) A6263AZ Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM) A6183AZ Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory
installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler panels for controllers
and disks. A6188A 0D1 Virtual Array Controller no memory installed A6185A 0D1 256-MB Cache for Virtual Array Controller, 1×256MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6186A 0D1 512-MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6187A 0D1 2×512MB Cache for Virtual Array Controller, 2×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6192A 0D1 36-GB 10K RPM FC HDD Module A6193A 0D1 36-GB 15K RPM FC HDD Module A6194A 0D1 73-GB 10K RPM FC HDD Module A7288A 0D1 73-GB 15K RPM FC HDD Module A6203A 0D1 Optical Gigabit Interface Circuit (GBIC) A3583A 0D1 2-meter FC fiber optic cable M/M multimode SC-SC A3531A 0D1 16-meter FC fiber optic cable M/M multimode SC-SC A3735A 0D1 50-meter FC fiber optic cable M/M multimode SC-SC A3736A 0D1 100-meter FC fiber optic cable M/M multimode SC-SC C7529A 0D1 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 0D1 16-meter FC fiber optic cable M/M duplex LC-SC C7534A 0D1 FC fiber optic coupler F/F SC-SC C7540A 0D1 FC adapter kit (includes C7529A and C7534A)
VA7100 Modules
A6183AE Field upgrade product. Select Virtual Array Controller (one or two) and cache product separately (factory installed).
Field Installed. Includes enclosure assembly, user manual, and 2 power supplies. This product is shipped without disks
or controllers/cache and includes filler for controllers and disks. A6261AE Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 256-MB Cache A6262AE Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 512-MB Cache (1×512-MB DIMM) A6263AE Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512-MB DIMM) A6188A Virtual Array Controller no memory installed A6185A 256-MB Cache for Virtual Array Controller, 1×256MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6186A 512-MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6187A 2×512MB Cache for Virtual Array Controller, 2×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if 2nd installed). Order 1 per installed VAP A6192A 36-GB 10K RPM FC HDD Module A6193A 36-GB 15K RPM FC HDD Module A6194A 73-GB 10K RPM FC HDD Module A7288A 0D1 73-GB 15K RPM FC HDD Module A6196A Deskside cabinet for HP StorageWorks VA7100 A6203A Optical Gigabit Interface Circuit (GBIC) A3583A 2-meter FC fiber optic cable M/M multimode SC-SC A3531A 16-meter FC fiber optic cable M/M multimode SC-SC A3735A 50-meter FC fiber optic cable M/M multimode SC-SC A3736A 100-meter FC fiber optic cable M/M multimode SC-SC C7529A 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 16-meter FC fiber optic cable M/M duplex LC-SC C7534A FC fiber optic coupler F/F SC-SC C7540A FC adapter kit (includes C7529A and C7534A)
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-103
Information Subject to Change
Chapter 4 Peripherals and Accessories
VA7100 Rail Kits
The following rail kits are needed to mount the VA7100 into the specific racks as listed.
Part Number Description
A6209A System/E Rail Kit (RoseBowl 2) A6496A NTRittal Rack rail kit A6244A HP Original rack rackmount hardware kit
VA7110 Hardware Ordering Information
The following codes define the suffixes on product numbers: A = Field Racked, AE = diskless enclosure (field disk integration), AZ = Factory Racked.
Order drives separately from the Enterprise Module section using the 0D1 option for integration. “AE” products are shipped as diskless enclosure only no integration (disks are ordered separately and field installed).
Product Number Option Number Description VA7110 Field RK SKU
A7294A Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM) A7296A Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 2048-MB Cache (2×1024MB DIMM) A7293A 0D1 Field upgrade product. Select Virtual Array Controller (two) and cache (minimum 1024 MB) and disk options separately
(factory installed). Includes filler for controllers and disks. (Note that single controller configurations are not
supported!) A6183AE Empty Enclosure A7293A 0D1 Virtual Array Controller no memory installed (Note that single controller configurations are not supported!) A6186A 0D1 1×512MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP A6187B 0D1 1×1024MB Cache for Virtual Array Controller, 1×1024MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP A6192A 0D1 36-GB 10K RPM FC HDD Module A6193A 0D1 36-GB 15K RPM FC HDD Module A6194A 0D1 73-GB 10K RPM FC HDD Module A7288A 0D1 73-GB 15K RPM FC HDD Module A7289A 0D1 146-GB 10K RPM FC HDD Module C7524A 0D1 Fiber Optic Cable 2-meter LC 50/125 M/M C7525A 0D1 Fiber Optic Cable 16-meter LC Duplex 50/125 M/M C7526A 0D1 Fiber Optic Cable 50-meter LC Duplex 50/125 M/M C7527A 0D1 Fiber Optic Cable 200-meter LC Duplex 50/125 M/M C7529A 0D1 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 0D1 16-meter FC fiber optic cable M/M duplex LC-SC C7534A 0D1 FC fiber optic coupler F/F SC-SC C7540A 0D1 FC adapter kit (includes C7529A and C7534A) VA7110 Factory Rack A7294AZ Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM) A7296AZ Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 2048-MB Cache (2×1024MB DIMM) A6183AZ 0D1 Field upgrade product. Select Virtual Array Controller (one or two) and cache (minimum 1024 MB) and disk options
separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler
panels for controllers and disks. A6186A 0D1 1×512MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP A6187B 0D1 1×1024MB Cache for Virtual Array Controller, 1×1024MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP A6192A 0D1 36-GB 10K RPM FC HDD Module A6193A 0D1 36-GB 15K RPM FC HDD Module A6194A 0D1 73-GB 10K RPM FC HDD Module A7288A 0D1 73-GB 15K RPM FC HDD Module A7289A 0D1 146-GB 10K RPM FC HDD Module C7524A 0D1 Fiber Optic Cable 2-meter LC 50/125 M/M
4-104 HP e3000 Business Servers Configuration Guide – Effective 1/04
Information Subject to Change
Chapter 4
Peripherals and Accessories
Product Number Option Number Description
C7525A 0D1 Fiber Optic Cable 16-meter LC Duplex 50/125 M/M C7526A 0D1 Fiber Optic Cable 50-meter LC Duplex 50/125 M/M C7527A 0D1 Fiber Optic Cable 200-meter LC Duplex 50/125 M/M C7529A 0D1 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 0D1 16-meter FC fiber optic cable M/M duplex LC-SC
VA7110 Modules
A7294AE Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM) A7296AE Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 2048-MB Cache (2×1024MB DIMM) A6183AE Empty Enclosure A7293AE Virtual Array Controller no memory installed (Note that single controller configurations are not supported!) A6186A 1×512MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP
A6187B 1×1024MB Cache for Virtual Array Controller, 1×1024MB DIMM, StorageWorks VAP requires equal cache for both
Controllers (if two are installed). Order 1 per installed VAP A6192A 36-GB 10K RPM FC HDD Module A6193A 36-GB 15K RPM FC HDD Module A6194A 73-GB 10K RPM FC HDD Module A7288A 73-GB 15K RPM FC HDD Module A7289A 146-GB 10K RPM FC HDD Module A6203A Optical Gigabit Interface Circuit (GBIC) A3583A 2-meter FC fiber optic cable M/M multimode SC-SC A3531A 16-meter FC fiber optic cable M/M multimode SC-SC A3735A 50-meter FC fiber optic cable M/M multimode SC-SC A3736A 100-meter FC fiber optic cable M/M multimode SC-SC C7529A 2-meter FC fiber optic cable M/M duplex LC-SC C7530A 16-meter FC fiber optic cable M/M duplex LC-SC C7534A FC fiber optic coupler F/F SC-SC C7540A FC adapter kit (includes C7529A and C7534A)
VA7110 Rail Kits
The following rail kits are needed to mount the VA7110 into the specific racks as listed.
Part Number Description
A6209A System/E Rail Kit (RoseBowl 2) A6496A NTRittal Rack rail kit A6244A HP Original rack rackmount hardware kit
HP e3000 Business Servers Configuration Guide – Effective 1/04 4-105
Information Subject to Change