HP T750 User Manual

QuickSpecs
HPE Line Interactive Single Phase UPS

Overview and Models

Page 1
HPE Line Interactive Single Phase Uninterruptible Power Systems (UPS)
Looking for cost-effective power protection for your small office environments?
HPE
based systems designed to
safeguard tower servers and small office equipment, to rack
Standard features
inc
Enhance Battery Management (EBM) that help to extend the
service
Power Protection, a power management software application that ships with each model, combined
wi
Systems
Insight Manager
When you need it, use outstanding
Care Pack Services,
have the security of knowing that your
server.
HPE
UPS units
is our exclusive 30
Power Manager Software that the battery may fail, the battery is replaced free of charge under the warranty. This warranty is offered worldwide.
Tower UPS Models
HPE T750 G4 UPS Models
HPE T750 G4 NA/JP Uninterruptible Power System
J2P85A
HPE T750 G4 INTL Uninterruptible Power System
J2P88A
HPE T1000 G4 UPS Models
HPE T1000 G4 NA/JP Uninterruptible Power System
J2P86A
HPE T1000 G4 INTL Uninterruptible Power System
J2P89A
HPE T1500 G4 UPS Models
HPE T1500 G4 NA/JP Uninterruptible Power System
J2P87A
HPE T1500 G4 INTL Uninterruptible Power System
J2P90A
Rack/Tower UPS Models
HPE R/T2200 G4 UPS Models
HPE R/T2200 G4 NA/JP Uninterruptible Power System
J2R00A
HPE R/T3000 G4 UPS Models
HPE R/T3000 G4 Low Voltage NA/JP Uninterruptible Power System
J2R01A
HPE R/T3000 G4 High Voltage NA/JP Uninterruptible Power System
J2R02A
HPE R/T3000 G4 High Voltage INTL Uninterruptible Power System
J2R04A
Rack UPS Models
R1500 G4 Models
HPE R1500 G4 NA Uninterruptible Power System
J2Q99A
HPE R1500 G4 JP/TWN Uninterruptible Power System
J2R05A
HPE R1500 G4 INTL Uninterruptible Power System
J2R03A
R5000 UPS Models
HPE R5000 3U L630 High Voltage NA/JP Uninterruptible Power System
AF460A
HPE R5000 3U IEC309-32A High Voltage INTL Uninterruptible Power System
AF461A
Line Interactive Single Phase Uninterruptible Power System (UPS) solutions range from tower-
-based systems that can protect a full rack of servers.
lude intuitive front panel displays for local management, and HPE
-life of your batteries. HPE
th a UPS Network Module, optional on some models, enables you to remotely monitor and manage your UPS through HPE
or via a standard web browser.
HPE support services for your whole data center environment. With HPE
HPE UPS will be covered at the same service level and coverage period as your HPE
UPSs are backed by a 3-year limited warranty, with the first year including parts and labor. Also, standard on all HPE
-day Battery Pre-Failure Warranty, which ensures that when customers receive notification from HPE
QuickSpecs
HPE Line Interactive Single Phase UPS
Overview and Models
Page 2
R7000 UPS Models
HPE R7000 4U 50A High Voltage NA/JP Uninterruptible Power System
AF462A
HPE R7000 4U IEC-32A High Voltage INTL Uninterruptible Power System
AF463A
QuickSpecs
HPE Line Interactive Single Phase UPS

Tower UPS Features

Page 3
Tower UPS Rear Panel
HPE T750 G4 UPS INTL
HPE T1000 G4 UPS INTL
HPE T1500 G4 UPS INTL
1. USB Communication Port
4. Socket for Connection to AC Power Source
2. RS
5. Ground Screw
3. Outlets for Connection of Critical Equipment
HPE T750 G4 UPS NA/JPN
HPE T1000 G4 UPS NA/JPN
HPE T1500 G4 UPS NA/JPN
1. USB Communication Port
4. Attached 6
2. RS-232 Communication Port
5. Ground Screw
3. Outlets for Connection of Critical Equipment
Tower UPS Models Provide Power Protection and Management Optimized for Smaller IT Environments
Key Features
Intelligent manageability with bundled Power Manager Software.
NOTE: Certain restrictions and exclusions apply. Consult the HPE Computer Support Center for details.
-232 Communication Port
Manageability through USB and Serial ports
Ease of configuration via enhanced front panel display.
-ft. Input Power Cord for AC Power Source
QuickSpecs
HPE Line Interactive Single Phase UPS

Tower UPS Specifications

Page 4
Towers G4 UPS Specifications
Battery Type
12 V, sealed, maintenance-free, rechargeable, valve regulated lead-acid batteries with a 3-5 year service life at 25C (77F).
Electrical Input
Voltage Range
± 20% for nominal voltages of 100, 110, 120, 220, 230, and
power ranges.
Frequency
50/60 Hz
Online Efficiency
>94%
REPO
N/A
Online Regulation
-10% to +6% of nominal voltage
Electrical Output
On battery Regulation
±5%, -10% of nominal voltage
Voltage Wave Form
Sine wave
Connections
See Model Selection Matrix
Output protection
Firmware overload sensing and control
Battery
Extended Batteries
N/A
Backup Time
See Backup Times Chart
Recharge Time
<4 hours to charge 90% usable capacity. <24 hours for complete recharge
Communications
Serial Ports
RS232 (via RJ45 connector to DB9) and USB ports (ships with communication cables)
Option Slot
N/A
Option Cards
N/A
LCD Interface
LCD Display and Button Interface
Software
HPE Power Protector management software available via download
Environmental and Safety
Operating Temperature
32° to 104° F (0° to 40° C) ( with battery)
Non-operating
-15° to 55° F (-26° to 13° C) (without battery)
Operating Humidity
5% to 90% (non-condensing)
Storage Humidity
5% to 90% (non-condensing)
Operating Altitude
Up to 1500 m above sea level
Audible Noise
<40dB in normal operation. <45dB while on inverter
Safety Markings
NA/JPN: UL/cUL, ICES B,NOM,VCCI, Int'l: CE,TUV GS,C-tick,EAC,KC
Safety Certifications
UL1778, UL60950-1; CSA22.2 No.107.3-05,; EN609501-, EN62040-1 IEC62040-1-1, IEC 60950-1
REPO Port
N/A
HPE T750 G4 UPS Specifications
See model matrix for other specifications.
T750 G4, NA/JP
Load Segments
1
Unit Dimensions (WxDxH)
5.9 x 13.4 x 8.3 inch (150 x 340 x 210 mm)
Shipping Dimensions(LxWxH)
18.7x 9.4 x 12.1 inch (476 x 238 x 308 mm)
240VAC. NOTE: Nominal voltages to coincide with standard
Temperature
J2P85A
QuickSpecs
HPE Line Interactive Single Phase UPS
Tower UPS Specifications
Page 5
T750 G4, INTL
Unit Weight
23.6 lbs (10.7kg)
Shipping Weight
26.4 lbs (12 kg)
HPE T1000 G4 UPS Specifications
T1000 G4, NA/JP
Load Segments
1
Unit Dimensions (WxDxH)
5.9 x 13.4x 8.3 inch (150 x 340x 210 mm)
Shipping Dimensions(LxWxH)
18.7 x 9.4 x 12.1 inch (476 x 238 x 308 mm)
Unit Weight
25.1 lbs (11.4kg)
Shipping Weight
28.7 lbs (13 kg)
HPE T1500 G4 UPS Specifications
T1500 G4, NA/JP
Load Segments
1
Unit Dimensions (WxDxH)
5.9 x 16.1 x 8.3inch (150 x 410 x 210 mm)
Shipping Dimensions(LxWxH)
19.6 x 9.4 x 12.1 inch (498 x238 x 308 mm)
Unit Weight
34.4 lbs (15.6 kg)
Shipping Weight
37.3 lbs (16.9 kg)
NOTE: Locate which Operating Systems are supported at: http://www.hp.com/products/powermanager.
HPE R/T2200 and R/T3000 Tower Uninterruptible Power System (UPS)
R/T3000 in Rack UPS configuration
R/T3000 with Tower UPS floor stands
HPE R/T2200 Uninterruptible Power System (UPS)
J2P88A
J2P86A T1000 G4, INTL J2P89A
J2P87A T1500 G4, INTL J2P90A
QuickSpecs
HPE Line Interactive Single Phase UPS

HPE Rack/Tower UPS specifications

Page 6
Front panel
1
Battery compartment
2
Control buttons and LED display
NA/JPN/TWN rear panel
Load segment 1 (one NEMA 5-15 output receptacle for surge and battery backup protection)
USB communications port
Load segment 2 (one NEMA 5-15 output receptacle for surge and battery backup protection)
REPO port
Load segment 3 (one NEMA 5-15 output receptacle for surge and battery backup protection)
Voltage
Load segment 4 (one NEMA 5-15 output receptacle for surge and battery backup protection)
Power sensitivity adjustment dial
5 Input circuit breaker
12 Ground bonding screw
6
Input power cord with NEMA 5-20 plug
13
ERM connector
7
Serial communications port
HPE R/T3000 Uninterruptible Power System (UPS)
1
2
3
4
8
9
10
11
configuration and charge rate DIP switches
QuickSpecs
HPE Line Interactive Single Phase UPS
HPE Rack/Tower UPS specifications
Page 7
Front Panel
1
Battery compartment
2
Control buttons and LED display
NA/JPN rear panel
1
UPS option card
7
Load segment 2 (two NEMA 5-20R T-slot receptacles)
2 USB communications port
8 PDU output (NEMA L5-30R) receptacle (load segment 1)
3
Serial communications port
9
Cord retention clip attachment location
4
Load segment circuit breaker
10
Cord retention clip attachment location
5
Load segment 1 (two NEMA 5-20R T-slot receptacles)
11
Ground bonding screw
6
Load segment circuit breaker
12
Power cord with L5-30 plug
HPE R/T2200 and R/T3000 Tower Uninterruptible Power System (UPS)
Flexible Rack/Tower Models Deliver Cost-Effective Power Protection
Key features
Convertible design can be used as a 2U rack mountable UPS or as a standalone tower UPS
Enhanced system flexibility with two independently controlled load segments
Power density up to 3000VA / 2700 Watts (200-240V models)
Easy configuration through enhanced front panel display
More efficient voltage regulation using digital signal processing technology
QuickSpecs
HPE Line Interactive Single Phase UPS
HPE Rack/Tower UPS specifications
Page 8
Support for Remote Emergency Power Off (REPO) circuitry
Specifications
R/T2200 G4 UPS (NA/JPN only)
Battery Type
12 V, 34W, sealed, maintenance-free, rechargeable, valve regulated lead-acid batteries with a 3-5 year service life at 25C (77F).
Electrical Input
Voltage Range
See Model Matrix for nominal and user selectable voltage settings; Battery string voltage 48Vdc
Frequency
50/60 Hz
Online Efficiency
94%
REPO
Remote Emergency Power-Off disables AC power to load
Online Regulation
-10% to +6% of nominal voltage
Electrical Output
On battery Regulation
±5% of nominal voltage
Voltage Wave Form
Sine wave
Connections
See Model Selection Matrix; divided into 2 Load Segments
Type
Maintenance-free, sealed, valve-regulated lead acid (VRLA)
Battery
Extended Batteries
Up to four ERMs can be supported; recommendation is up to 2
Backup Time
See Backup Times Chart
Recharge Time
<3 hours to 90% usable capacity; <48 hours for complete recharge
Serial Ports
Standard DB-9 and USB ports (ships with communication cables)
Communications
Option Slot
One (For Optional Communication Card)
Option Cards
HPE UPS Network Module (not included in kit but orderable option)
LCD Interface
LCD Display and Button Interface
Software
HPE Power Protector software available via download
Environmental and Safety
Operating Temperature
0°C to 40°C (32°F to 104°F); Long term use at higher temperature will reduce battery life 25°C (77°F)
Non-operating
-15°C to 50°C (-5°F to 122°F)
Operating Humidity
20% to 90% (non-condensing)
Storage Humidity
10% to 90%
Operating Altitude
Up to 6,562 ft (2000 m) above sea level
Audible Noise
<40dB in normal operation. <45dBon battery operation
Safety Markings
NA/JPN: UL, cUL, VCCI
Safety Certifications
UL1778, UL60950-1; CSA22.2 No.107.3-05,; EN60950-1,
REPO Port
Meets NEC code 645-10 and 645-11and UL requirements
Unit Dimensions (LxWxH)
20.55x 17.36 x 3.39 inches / 522x 441 x 86.2 mm
Shipping Dimensions(LxWxH)
36.26 x 23.23 x 11.02 inches / 921 x 590 x 280 mm
Unit Weight
65.28 lbs/29.61 kg
Shipping Weight
83.62 lbs UPS and 83.62 lbs ERM / 37.93 kg & 37.93 kg
R/T3000 G4 UPS
Easy serviceability through modular design
Temperature
EN62040-1IEC62040-1-1, IEC 60950-1,
QuickSpecs
HPE Line Interactive Single Phase UPS
HPE Rack/Tower UPS specifications
Page 9
Battery Type
12 V, 34W, sealed, maintenance-free, rechargeable, valve regulated lead-acid batteries with a 3-5 year service life at 25C (77F).
Electrical Input
Voltage Range
See Model Matrix for nominal and user selectable voltage settings; Battery string voltage 72Vdc
Frequency
50/60 Hz
Online Efficiency
94%
REPO
Remote Emergency Power-Off disables AC power to load
Online Regulation
-10% to +6% of nominal voltage
Electrical Output
On battery Regulation
±5% of nominal voltage
Voltage Wave Form
Sine wave
Connections
See Model Selection Matrix; divided into 2 Load Segments
Output Protection
Re-settable circuit protectors
Type
Maintenance-free, sealed, valve-regulated lead acid (VRLA)
Battery
Extended Batteries
Up to four ERMs can be supported; recommendation up to 2
Backup Time
See Backup Times Chart
Recharge Time
<3 hours to 90% usable capacity; <48 hours for complete recharge
Serial Ports
Standard DB-9 and USB ports (ships with communication cables)
Communications
Option Slot
One (For optional communication card)
Option Cards
HPE UPS Network Module (not included in kit but orderable option)
LCD Interface
LCD Display and Button Interface
Software
HPE Power Protector software available
Environmental and Safety
Operating Temperature
0°C to 40°C (32°F to 104°F); Long term use at higher temperature will reduce battery life at 25°C (77°F)
Non-operating Temperature
-15°C to 50°C (-5°F to 122°F)
Operating Humidity
20% to90% (non-condensing)
Storage Humidity
10% to 90%
Operating Altitude
Up to 6,562 ft (2000 m) above sea level
Audible Noise
<4dB in normal operation. <50bB on battery operation
Safety Markings
NA/JPN LV /HV: UL, cUL, VCCI Int'l: GS, CE, C-tick, TUV, EAC
Safety Certifications
UL1778, UL60950-1; CSA22.2 No.107.3-05,; EN60950-, EN62040-1 IEC62040-1-1, IEC 60950-1
REPO Port
Meets NEC code 645-10 and 645-11and UL requirements
Unit Dimensions (LxWxH)
25.47 x 17.4 x 3.4 inches / 647 x 441x 86.2 mm
Shipping Dimensions(LxWxH)
36.26 x 23.23 x 11.02 inches / 921 x 590 x 280 mm
Unit Weight
87.17 lbs/39.54 kg
Shipping Weight
107.48 lbs UPS and 120.59 lbs ERM / 48.75 kg & 54.7kg
HPE R1500 G4 NA and JP/TWN UPS
QuickSpecs
HPE Line Interactive Single Phase UPS
HPE Rack/Tower UPS specifications
Page 10
1. IUSB Communication Port
6a. Group 1: programmable outlets for equipment connection
2.
ES-232 Communication Port
6b.
Group 2: programmable outlets for equipment connection
3.
Slot for optional communication card
7.
Attached 6ft input power cord Nema 5-15P for AC power source,
4. Connector for ROO(Remote On/Off) or RPO (Remote Power Off) Control
8. LED indicating site wiring fault alarm
5. Outlets for connection of critical equipment (Primary group)
9. Ground screw
HPE R1500 G4 International UPS
1.
USB communication port
6a.
Group 1: programmable outlets for equipment connection
2.
RS-232 communication port
6b
Group 2: programmable outlets for equipment connection
3. Slot for optional communication card
7. Input power connection (IEC -320-C14) for powering unit to AC power source
4. Connector for ROO (Remote On/Off) or RPO (Remote Power Off) control
8. Ground screw
5. Outlets for connection of equipment (Primary group)
R5000 UPS
QuickSpecs
HPE Line Interactive Single Phase UPS
HPE Rack/Tower UPS specifications
Page 11
Front View Rear View
2.
Scroll up button
2.
3.
Scroll down button
3.
Load segment 1 (two IEC-320-C19 receptacles, two IEC-
4.
Enter/Select button
4.
Cord retention clip attachment locations
5.
Power button
5.
Load segment 2 (two IEC-320-C19 receptacles and two
6.
REPO port
7.
USB communications port
8.
Serial communications port
9.
HPE UPS Network Module (included)
10.
Ground bonding screw
11.
Input power line cord with NEMA L6-30 plug
12.
Load segment 2 circuit breaker
13.
Large output NEMA L6-30R receptacle or IEC-309-32A
14.
ERM Connector for large plug
R7000 UPS
Front View Rear View
Escape Button
1.
1. ERM connector for the small plug on the split ERM cable
Load segment 1 circuit breaker (controls the C19 and C13 receptacles, but does not control the large output
320- C13 receptacles)
IEC- 320-C13 receptacles)
receptacle associated with load segment 1
QuickSpecs
HPE Line Interactive Single Phase UPS
HPE Rack/Tower UPS specifications
Page 12
2.
Scroll up button
2.
3.
Scroll down button
3.
Large output NEMA L6-30R receptacle or IEC-60309
4.
Enter/Select button
4.
Cord retention clip attachment locations
5.
Power button
5.
Load segment 1 circuit breaker (controls the C19
6.
3 x IEC C19 receptacles on load segment 1
7.
HPE UPS Network Module
8.
9.
Ground bonding screw
10.
Serial communications port
11.
USB communications port
12.
REPO port
13.
3 x IEC C19 receptacles on load segment 2
14.
Ultra-Dense Rack UPS Models Scale from Small to Enterprise IT Environments
Specifications
HPE R1500 G4 UPS
Electrical Input
Voltage Range
± 15% of nominal100 and 120V models and ± 20% of nominal on 230V models. See Model Matrix voltage settings via LCD Front Display Panel
Frequency
50/60 Hz ± 5Hz (auto sensing at default voltage )
Online Efficiency
92%
Electrical Output
Online Regulation
-10% to +6% of nominal voltage*
On battery Regulation
-10% / + 6%of nominal voltage
Voltage Wave Form
Sine wave
Connections
See Model Matrix; divided into3 Load Segments
Output Protection
Firmware overload sensing and control,
Battery
Type
Maintenance-free, sealed, valve-regulated lead acid (VRLA)
Backup Time
See Backup Times Chart
Recharge Time
<3 hours to 90% usable capacity; <24 hours for complete recharge
Voltage
36V Battery String
Communications
Ports
Standard DB-9 port (Kit ships with cable for communication ) USB port (Kit ships with cable for communication)
Option Slot
One ( for Optional Communication Card)
Option Cards
HPE UPS Network Module (Not included in Kit but orderable Option)
LED Indicators
LED display integrated into the front panel
Software
HPE Power Protector management software available via download
Environmental and Safety
Operating Temperature
32° to 104° F (0° to 40° C) ( with battery)
1. Escape Button 1.
Load segment 1 circuit breaker (controls L6-30R receptacle Item 3)
Load segment 2 circuit breaker (controls L6-30R receptacle Item 15)
32A receptacle on short cords associated with load
receptacles, but does not control the large output
Input power line cord with NEMA CS8265C plug or IEC-309- 32A plug
Load segment 2 circuit breaker (controls the C19 receptacles, but does not control the large output receptacle)
Key Features
Front panel LCD display
Enhanced system flexibility with two independently controlled load segments
for nominal and user selectable
QuickSpecs
HPE Line Interactive Single Phase UPS
HPE Rack/Tower UPS specifications
Page 13
Storage Temperature
-15° to 55° F (-26° to 13° C) (without battery)
Humidity (Operation)
0% to 90%
Humidity (Non-operating)
0% to 90%
Operating Altitude
up to 2000 meters
Audible Noise
<40db (at 1m from surface of unit) <45dBA while on inverter
Safety Markings
UL/cUL CE, TUV, C-tick, CES, EAC, VCCI, GS, KC, EK, BSMI
Safety Certifications
UL1778; UL60950, CSA22.2 No.107.1,No.107.3,; CB Bulletin IEC62040 2+A1 +A2; EN 61000-3-3
EMC Markings
FCC-BCISPR 22; VCCI B; CE, BSMI, C-TICK
Emissions
FCC CFR 47, Part 15 Class A, EN50091-2
Immunity
EN 55024; EN 50091-2 consisting of IEC 61000-4-2 thru IEC 61000-4-6 ; IEC 61000-4-11
Surge Suppression
Conforms to IEEE 587B and ANSI C62.41
Unit Dimensions (LxWxH)
21.8x 17.2x 1.69 in (554 x 438 x 43 mm)
Shipping Dimensions
30.71x 22.8 x6.1 in (780 x 580 x 155 mm)
Unit Weight
39.06 lb (19.72 kg)
Shipping Weight
54.45 lb (24.7 kg)
10% / +6% of the selected nominal voltage. The regulation is accomplished by
e
e to regulate
Transition set point voltages are subject to a hardware tolerances of +/-3% of the set point value.
R5000 3U UPS
BTU Break Down
BTU On Line
478 BT/hr
BTU On Battery
1041 BTU/hr
Battery Type
12V 27W
Electrical Input
Voltage Range
160-253V at 200/208V nominal; 176-253V at 220, 230, and 240V nominal
Frequency
50/60 Hz
Online Efficiency
94%
REPO
Remote Emergency Power-Off disables AC power to load
Online Regulation
-10% to +6% of nominal voltage
Electrical Output
On battery Regulation
±5% of nominal voltage
Voltage Wave Form
Sine wave
Connections
See Model Matrix; divided into 2 Load Segments
Output Protection
Re-settable circuit protectors
Type
Maintenance-free, sealed, valve-regulated lead acid (VRLA)
Battery
Extended Batteries
Up to four ERMs supported
Backup Time
See Backup Times Chart
-1; IEC 60950-1; EN60950-1;EN 62040-1; EN 61000-3-
* The R1500 G4 UPS regulates the output voltage at ­bucking or boosting the input voltage. The voltage regulation operation is governed by the unit's input voltage spec of +/-20%. The unit will regulate at -10% / +6% while within the limits set by the input spec. The unit will go to battery operation upon exceeding th limits set by the input spec. The buck and boost voltage regulation operation, or AVR (Automatic Voltage Regulation), is accomplished by adjusting output transformer tap selections via electromechanical relays. The transformer tap selection is controlled via digital transition voltage set point values programmed in the unit's firmware. These programmed values are without tolerance.
The unit will monitor the input voltage and accept a range of +/-3% of the selected nominal voltage as the target voltag at -10% / +6%. For example, a unit configured to 120V nominal voltage will regulate at -10% / +6% for any voltage measured between 116.4V and 123.6V. The digital transition voltage set point values will adjust accordingly to regulate to -10% / +6% of the measured input voltage.
QuickSpecs
HPE Line Interactive Single Phase UPS
HPE Rack/Tower UPS specifications
Page 14
Recharge Time
<3 hours to 80% usable capacity; <48 hours for complete recharge
Battery String Voltage
216V
Battery Type
12V 27W
Battery Quantity
18
Communications
LED Indicators
LED and switch membrane integrated into the front panel with four­button control (three buttons for UPS power control and one button under the front bezel for configuration).
Operating Temperature
50° to 104° F (10° to 40° C )
Storage Temperature
32° to 77° F (0° to 25° C )
Transit Temperature
-13° to 131° F (-25° to 55° C)
Unit Dimensions (HxWxD)
5 5 in (12.7 cm) x 17.2 in (43.7 cm) x 29.3 in (74.4 cm)
Shipping Dimensions
14.4 in ( 36.58 cm) x 23.6 in ( 60 cm) x 38.78 in ( 98.5 cm)
Unit Weight
126 lbs (57kg)
Shipping Weight
192 lbs ( 87 kg)
R7000 4U UPS
BTU Break Down
BTU On Line
581 BT/hr
BTU On Battery
1501 BTU/hr
Battery Type
12V 45W
Electrical Input
Voltage Range
160-253V at 200/208V nominal
Frequency
50/60 Hz
Online Efficiency
95%
REPO
Remote Emergency Power-Off disables AC power to load
Online Regulation
-10% to +6% of nominal voltage
Electrical Output
On battery Regulation
±5% of nominal voltage
Voltage Wave Form
Sine wave
Connections
See Model Matrix; divided into 2 Load Segments
Output Protection
Re-settable circuit protectors
Type
Maintenance-free, sealed, valve-regulated lead acid (VRLA)
Battery
Extended Batteries
Up to four ERMs supported
Backup Time
See Backup Times Chart
Recharge Time
<3 hours to 80% usable capacity; <48 hours for complete recharge
Battery String Voltage
216V
Battery Type
12V 45W
Battery Quantity
18
Maximum wattage based on voltage input
200-240V: 7200VA/7200W
Communications
Serial Ports
Standard DB-9 and USB ports (ships with communication cables)
Option Cards
HPE UPS Network Module
LED Indicators
LED and switch membrane integrated into the front panel with four-
for UPS power control and one button
under the front bezel for configuration).
Environmental and Safety
Operating Temperature
50° to 104° F (10° to 40° C )
Storage Temperature
32° to 77° F (0° to 25° C )
Environmental and Safety
button control (three buttons
QuickSpecs
HPE Line Interactive Single Phase UPS
HPE Rack/Tower UPS specifications
Page 15
Transit Temperature
-13° to 131° F (-25° to 55° C)
Operating Humidity
20% to 80% (non-condensing)
Storage Humidity
5% to 95%
Operating Altitude
Up to 6,562 ft (2000 m) above sea level
Transit Altitude
49,212 ft (15,000 m) above sea level
Audible Noise
<46db in normal operation(at 1m from surface of unit)
Safety Markings
NA/JPN: UL, cUL Int'l: GS, CE, GOST
Safety Certifications
UL1778, UL60950-1; CSA22.2 No.107.3, No.60-1950; EN50091­1-1; EN60950-1 IEC62040-1-1
EMC Markings
NA/JPN: FCC, VCCI, ICES, CISPR Int'l: BSMI, C-Tick, CISPR
Emissions
FCC CFR 47, Part 15 Class A, EN50091-2
Immunity
IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5
REPO Port
Meets NEC code 645—11 intent and UL requirements
Unit Dimensions (HxWxD)
6.75 in (17.1 cm) x 17.2 in (43.7 cm) x 28.9 in (73.4 cm)
Shipping Dimensions (H x L x W)
16.10 in (40.9cm) x 23.6 in. (59.9cm) x 38.8 (98.6cm)
Unit Weight
165 lbs/75 kg
Shipping Weight
210 lbs/100 kg
QuickSpecs
HPE Line Interactive Single Phase UPS

Related Options

Page 16
UPS Network Module
The HPE UPS Network Module enables you to monitor and manage power environments through comprehensive control of UPS configuration or provide additional power protection with support for dual red configuration for no management control and flexible monitoring.
The management module can be configured to send alert traps to othe enables you to monitor and manage UPSs through the network. To facilitate day tasks, the embedded management software provides detailed system logs.
The to the network. Configuration & Management of the UPS from anywhere and at anytime via a standard web browser.
NOTE: see: http://www.hp.com/go/hpunm.
Extended Runtime Module (ERM)
Extended Runtime Modules increase the available runtime for the larger rack mounted UPS units to allow customers to ensure all of their failure.
2U R/T UPS ERM Shipping Kit
HPE 2U Rack/Tower UPS Shipping Kit
L4Q11A
NOTE: The optional 2U shipping kit consists of heavy duty rails, front and back CTO brackets and required mounting hardware for attaching the UPS or ERM to the rack. This kit is an option that is required if the UPS and or ERM are going to be mounted into a rac required per unit, whether UPS or ERM.
Extended Runtime Modules (ERM)
HPE R/T2200 G4 Extended Runtime Module HPE HPE
NOTE: AF455A can only be used with the G2 models.
J2R09A J2R10A
AF455A
HPE R5KVA and R7KVA 3U Extended Runtime Module
AF464A
NOTE: #0D1 will appear after the part number on the sales order if HPE factory integration is indicated.
UPS Management
HPE UPS Network Module Mini-slot Kit
AF465A
HPE UPSs. The HPE UPS Management Module can support either a single
undant UPS
-single-point-of-failure. The additional serial ports will provide greater power
HPE Systems Insight Manager and
r SNMP management programs or used as a standalone management system. This flexibility
-to-day maintenance
HPE UPS Network Module provides remote management of a UPS by connecting the UPS directly
For more information on the UPS Network Module please
applications can be gracefully shutdown in the event of a power
R/T2200 G4 & R/T3000 G4 Extended Runtime Module – 2U
R5000 & R7000 Extended Runtime Module – 3U
k that will be shipped via transport. One of these kits is
R/T3000 G4 Extended Runtime Module R/T3000 2U Extended Runtime Module
QuickSpecs
HPE Line Interactive Single Phase UPS

Warranty and Care Pack

Page 17
Warranty
When you need it, use outstanding HPE support services for your whole data center environment. With HPE service level and coverage period as your warranty, with the first year including parts and labor. Also, standard on all exclusive 30 from under the warranty. This warranty is offered worldwide.
NOTE: $250,000 Computer/Load Protection Guarantee is also provided (applicable in North America
only).
The standard on all advantage of a
the battery before it actually fails. This warranty is offered worldwide. Specifically, the Battery Pre-Failure Warning ensures that when customers receive notification from replaced
NOTE: $250,000 Computer/Load Protection Guarantee is also provided in North America, in addition
to the
Warranty Upgrade Options
Duration - Select duration of coverage for a minimum period of 1 year or multiple years
Service and Support
HPE Technology Services
HPE infrastructure problems. We help keep your business running, boost availability and avoid downtime.
Protect your business beyond warranty with
When you buy HPE designed to meet your IT and business need.
Insight Remote Support
Delivers secure remote monitoring and support for Hewlett Packard Enterprise servers and storage, 24x7 at no additional cost. Available as part of HPE Warranty, Care Pack and Service Contract offers.
Parts and materials
Hewlett Packard Enterprise will provide HPE-supported replacement parts and materials necessary to maintain the covered hardware product in operating condition, including parts and materials for available and recommended engineering improvements. Supplies and consumable provided as part of this service; standard warranty terms and conditions apply. Parts and components that have exceeded their maximum supported lifetime and/or the maximum usage limitations as set forth in the manufacturer's operating man repaired or replaced as part of this service.
Coverage
For ProLiant servers and storage systems, this service covers HPE-branded hardware options qualified for the server, purchased at the monitors up to 22" and tower UPS products; these items will be covered at the same service level and for the same coverage period as the server unless the maximum supported lifetime an usage limitation has been exceeded. Coverage of the UPS battery is not included; standard warranty terms and conditions apply.
The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives replaced
due to malfunction. It does not apply to any exchange of Disk or SSD/Flash Drives that have not failed. SSD/Flash Drives that are specified by exceeded maximum supported lifetime and/or the maximum usage limit as set forth in the
Care Pack Services, have the security of knowing that your HPE UPS will be covered at the same
HPE server. HPE UPSs are backed by a 3-year limited
HPE UPS units is our
-day Battery Pre-Failure Warranty, which ensures that when customers receive notification
HPE Power Manager Software that the battery may fail, the battery is replaced free of charge
HPE UPS is covered by a three year warranty, with the first year including parts and labor. Also,
HPE UPS units, is our exclusive Battery Pre-Failure Warning, which extends the HPE three-year, limited warranty by applying it to
HPE Power Management Software that the battery may fail, the battery is
free of charge under the warranty.
HPE three year, limited warranty.
:
Response - Upgrade on-site response from next business day to same day 4-hours
Coverage - Extend hours of coverage from 5 days x 9 hours to 7 days x 24 hours
Technology Services offers you consultants and support experts to solve your most complex
HPE Care Pack Services
HPE Options, it's also a good time to think about what level of service you may need.
Care Pack services provide total care and support expertise with committed response choices
ual or the technical product data sheet will not be provided,
same time or afterward, internal to the enclosure, as well as external
by HPE
HPE as consumable parts and/or that have
parts will not be
d/or the maximum
QuickSpecs
HPE Line Interactive Single Phase UPS
Warranty and Care Pack
Page 18
manufacturer's operating manual or the technical data sheet are not eligible for the defective media retention service feature option.
For more information
To learn more on services for HPE ESSN Options, please contact your Hewlett Packard Enterprise sales representative or visit: http://www.hp.com/services/proliant
http://www.hp.com/services/bladesystem
Recommended HPE Care Pack Services for optimal satisfaction with your HPE product
Recommended Services
3-Year HPE 24x7 4 hour Response, Hardware Support Onsite Service
Provides you with rapid remote support and if required representative who will arrive on site any time and day of the year to begin hardware maintenance service within 4 hours of the service request being logged.
HPE ProLiant Server Hardware Installation Provides for the basic hardware installation of devices and networking options to assist you in bringing your new hardware into operation in a timely and professional manner
3-Year HPE 6 hour Hardware Support Onsite Call-to-Repair Service Provides an IT manager with a team of support specialists who will quickly begin troubleshooting the system to help return the hardware to operating condition within 6 hours of the initial service request to the HPE Global Solution Center
HPE Proactive Select Service Provides a flexible way to purchase Proactive Select Service Credits when you purchase your hardware and then use the credits over the next 12 months.
HPE Care Pack Services
HPE Install Universal Power Supply 3KVA to Below 6KVA Service
U4693E
HPE Install Universal Power Supply Less Than 3KVA Service
U4690E
Hewlett Packard Enterprise Authorized Channel Partner. Or
or
a Hewlett Packard Enterprise Authorized
Hewlett Packard Enterprise branded servers, storage
HPE best-in-class consultancy and technical services. You can buy
QuickSpecs
HPE Line Interactive Single Phase UPS

HPE Model Matrix

Page 19
HPE T750 G4 UPS Model
Part Number
Operating Voltage
Settings
Power Out (VA/Watts)
Input Connection
Output Connection
J2P85A (North America/Japan
110V to 120V
100V- Japan
750VA/525W 750VA/500W
Attached NEMA 5-15
16AWG
6 – NEMA 5-15
100V- Japan
750VA/500W
J2P88A International model
220V/230V/240V
750VA/525W
C14 Inlet ( For
specific power cord
6 – IEC C13 receptacles
HPE T1000 G4 UPS Model
Part Number
Operating Voltage
Settings
Power Out (VA/Watts)
Input Connection
Output Connection
J2P86A NA/JP
100V (Japan) to 110V
1000VA/680W
Attached Nema 5-15
16AWG
8 – Nema 5-15
J2P89A INTL
220V/230V/240V
1000VA/700W
C14 Inlet ( For
specific power cord
8 – IEC C13 receptacles
HPE T1500 G4 UPS Model
Part Number
Operating Voltage
Settings
Power Out (VA/Watts)
Input Connection
Output Connection
J2P87A NA/JP
100V Japan
120V
1200VA/980W
1440VA/1080W
Attached Nema 5-15
14AWG
8 – Nema 5-15
J2P90A INTL
220V/230V/240V
1500VA/1050W
C14 Inlet ( For
specific power cord
8 – IEC C13 receptacles
HPE R1500 G4 UPS Models
Part Number
Operating Voltage
Settings
Power Out
(VA/Watts)
Input Connection
Output Connection
Low-Voltage Models
J2Q99A NA
120V to 125V
1440/1100
NEMA 5-15P
5- Nema 5-15R
100V
1200/900
receptacles
J2R05A JP/TWN
100V
1200/900
NEMA 5-15P
5- Nema 5-15R
120V to 125V
1440/1100
Nema 5-15P With
Taiwan approval
5-Nema 5-15R
High Voltage Model
J2R03A INTL
220V/230V/240V
1550/1100
C14 inlet (for
specific power cord
6- IEC 320-C13
200V to 208V
1395/990
NOTE: Voltage is user selectable via LCD Front Display Panel
HPE R/T2200 G4 UPS
Part Number
Operating Voltage
Power Out
Input Connection
Output Connection
J2R00A NA/JP
120V to 125V
1920/1920
Nema 5-20P 20A 3m
8 –Nema 5-20
100V
1500/1400
HPE R/T3000 G4 UPS Models
Part Number
Operating Voltage
Settings
Power Out
(VA/Watts)
Input Connection
Output Connection
)
120V
1000VA/700W
Plug type power cord,
detachable country
Plug type power cord,
receptacles
receptacles
detachable country
110V
1325VA/994W
Plug type power cord,
receptacles
detachable country
Settings
(VA/Watts)
detachable country
cord
receptacles
Receptacles
QuickSpecs
HPE Line Interactive Single Phase UPS
HPE Model Matrix
Page 20
J2R01A LV NA/JP
120V1 to 125V
2880/2700
L5-30P, 2.4m cord
LS1-LS42: 6x NEMA 5-20
receptacle
100V
1500/1400
J2R02A HV NA/JP
208V1 to 240V
3000/2700
L6-20P, 2.4m cord
LS1-LS32:8xIEC C13
outlet)
200V
2490/2241
J2R04A HV INTL
208V to 240V (230V
1
)
3000/
2700
Detachable IEC C-20
cord
LS1-LS32: 8x IEC C13
200V
2490/2241
1
Factory default setting.
2
3
LS5 = Load Segment 5
HPE R5000 and R7000 UPS Models
Part Number
Operating Voltage
Settings
Power Out
(VA/Watts)
Input Connection
Output Connection
AF462A 200/208*
7200VA/7200W
Hubble CS8265C, 3m
LS1: 15A CB - 3 x C19 +
AF460A
200/208*, 220,
5000/4500
L6-30P, 3m cord
LS1: 15A CB - 2 x C19 +
1 x L6-30R
HPE R/T2200 G4 UPS
Part Number
Operating Voltage
Settings
Power Out
(VA/Watts)
Input Connection
Output Connection
J2R00A NA/JP
120V to 125V
1920/1920
Nema 5-20P 20A 3m
8 –Nema 5-20
100V
1500/1400
HPE R/T3000 G4 UPS Models
Part Number
Operating Voltage
Settings
Power Out
(VA/Watts)
Input Connection
Output Connection
J2R01A LV NA/JP
120V1 to 125V
2880/2700
L5-30P, 2.4m cord
LS1-LS42: 6x NEMA 5-20
receptacle
100V
1500/1400
J2R02A HV NA/JP
208V1 to 240V
3000/2700
L6-20P, 2.4m cord
LS1-LS32:8xIEC C13
outlet)
200V
2490/2241
J2R04A HV INTL
208V to 240V (230V
1
)
3000/
2700
Detachable IEC C-20
cord
LS1-LS32: 8x IEC C13
200V
2490/2241
1
Factory default setting.
2
3
LS5 = Load Segment 5
outlets,
3
LS5
: 1X NEMA L5-30
LS1 thru LS4 = Load Segment 1 thru 4 (or less depending on unit)
230, 240
inlet plug for attaching
country specific power
cord
LS53: 1x IEC C-19 (16A
LS53: 1x IEC C-19 (16A
outlet)
1 x L6-30R
LS2: 15A CB - 3 x C19 +
1 x L6-30R
2 x C13
LS2: 15A CB - 2 x C19 +
2 x C13
Plus one pigtailed
receptacle (LS1)
LS1 thru LS4 = Load Segment 1 thru 4 (or less depending on unit)
cord
Receptacles
LS5
inlet plug for attaching
country specific power
LS53: 1x IEC C-19 (16A
LS53: 1x IEC C-19 (16A
outlets,
3
: 1X NEMA L5-30
outlet)
QuickSpecs
HPE Line Interactive Single Phase UPS

Estimated Backup Times

Page 21
Tower UPS Models
Load
Load
Estimated battery runtime at 100%
(Minutes)
T750 UPS
20%
37
50%
250W
15
80%
7
100%
500W
5
T1000 UPS
20% 35
80% 7
100%
670W 5
T1500 UPS
20%
41
50%
475W
15
80%
7
100%
950W
5
Rack UPS Models
R1500 G4 UPS
Load
(Percent)
Load
(Watts)
20%
200
58
50%
500
17
80%
800
8
100%
1000 5
R/T2200 G4 UPS
Load
(Percent)
Load
(Watts)
20%
50%
80%
100%
R/T3000 G4 UPS
Load
(Percent)
Load
(Watts)
20%
50%
80%
(Percent)
(Watts)
battery charge
50% 335W 15
Minutes of Back up time
Minutes of Back up time
Minutes of Back up time
QuickSpecs
HPE Line Interactive Single Phase UPS
Estimated Backup
Times
Page 22
100%
R7000 UPS
Load (Percent*)
With internal batteries
With One Extended Runtime
Module
With Four Extended Runtime
Modules
540W (20%)
52 98 301
1350W (50%)
13 33 103
2160W (80%)
6
18
57
2700W (100%)
4
13
39
NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions.
R5000 UPS
Load (Percent*)
With internal batteries
With One Extended Runtime
Module
With Four Extended Runtime
Modules
540W (20%)
44
143
436
1350W (50%)
16
44
145
2160W (80%)
7
25
83
2700W (100%)
5.7
20
64
NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions.
(Minutes)
(Minutes)
(Minutes)
(Minutes)
(Minutes)
(Minutes)
QuickSpecs
HPE Line Interactive Single Phase UPS
Estimated Backup
Times
Page 23
R/T2200 G4 UPS
1920W 100%
R/T3000 G4 Low Voltage UPS
R/T3000 G4 High Voltage UPS
Environment-friendly
End-of-life Management
Hewlett Packard Enterprise offers end-of-life product return, trade-
Rack/Tower UPS Models
Estimates
Load (Percent*)
384W 20% 45 142 256 346 448
960W 50% 15 55 99 110 144
1536W 80% 7 34 60 53 78
540W 20% 40 125 225 349 452
1350W 50% 12 50 99 107 140
2160W 80% 6 30 60 67 88
2700W 100% 4 24 47 52 68
540W 20% 45 142 256 321 417
battery
runtime
(Minutes)
5 26 47 36 57
With One
Extended
Runtime
Module
(Minutes)
With Two Extended
Runtime Modules
(Minutes)
With Three
Extended
Runtime Modules
(Minutes)
With Four Extended
Runtime Modules
(Minutes)
1350W 50% 15 55 99 115 152
2160W 80% 7 34 60 72 95
2700W 100% 5 26 47 60 79
Products and Approach
and Recycling
in, and recycling programs, in many geographic areas, for our products. Products returned to Hewlett Packard Enterprise will be recycled, recovered or disposed of in a responsible manner.
http://www8.hp.com/us/en/hpe/hp­information/livingprogress/environmentalprogress/product­recycling.html#.V-lPA_krKiM
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard Enterprise web site. These instructions may be used by recyclers and other WEEE treatment facilities as well as Hewlett Packard Enterprise OEM customers who integrate and re-sell Hewlett Packard Enterprise equipment.
QuickSpecs
HPE Line Interactive Single Phase UPS
Estimated Backup
Times
Page 24
http://www8.hp.com/us/en/hpe/hp-
information/livingprogress/environmentalprogress/product­recycling.html#.V-lPA_krKiM
QuickSpecs
HPE Line Interactive Single Phase UPS

Summary of Changes

Page 25
Date
Version History
Action
Description of Change
26-Oct-2016
From Version 11 to 12
Changed
Version reverted.
26-Sep-2016
From Version 10 to 11
Changed
Overview and Models, Key Features, Tower UPS Compatibility, and Product Specifications were revised.
28-Sep-2015
From Version 9 to 10
Added
Added new Rack UPS Models to the Overview and Models section.
Towers G4 UPS Specifications table was added to Tower UPS Specifications.
HPE System (UPS) were added to Specifications.
Changed
Overview and Models, Tower UPS Features, HPE Rack UPS Specifications were revised.
Removed
Tower UPS Front Panel was removed from QuickSpecs.
04-Jun-2015
From Version 8 to 9 Changed
Overview and Models, HPE Tower UPS Specifications, HPE Rack UPS Specifications, Related Options, and Estimated Backup Times sections were revised.
Removed
Obsolete SKUs were removed from the QuickSpecs.
30-Mar-2015
From Version 7 to 8
Changed
Changes made throughout the entire QuickSpecs.
09-Feb-2015
From Version 6 to 7
Added
Added G4 models.
Changed
Changed name to HPE Line Interactive Single Phase Uninterruptible Power Systems (UPS).
Consolidated Tower, Rack/Tower, and Rack Models into one single QuickSpecs.
08-Feb-2013
From Version 5 to 6
Changed
Changed G3 to G2 in the Intelligent Manageability section.
24-Aug-2012
From Version 4 to 5
Changed
Change made in Models section.
15-Aug-2012
From Version 3 to 4
Removed
Removed inactive links.
09-Jan-2012
From Version 2 to 3
Changed
Revised an inactive link in the Compatibility section of Standard Features.
20-Jul-2011
From Version 1 to 2
Changed
Descriptions for the Models section were updated.
Sign up for updates
© Copyright 2016 Hewlett Packard Enterprise Development LP. The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such pr Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.
c04154342
R/T2200 and R/T3000 Tower Uninterruptible Power
HPE Rack/Tower UPS
HPE Model Matrix,
- 14058 - Worldwide - V12 - 26-October-2016
oducts and services.