HPE Synergy 12000 Frame Setup and
Installation Guide
Abstract
This document describes identification, installation, and setup for the HPE Synergy System.
This guide is for an experienced service technician. Hewlett Packard Enterprise assumes you
are qualified in the servicing of the HPE Synergy components and overall solution.
Part Number: 806424-003
Published: June 2018
Edition: 3
Copyright 2016-2018 Hewlett Packard Enterprise Development LP
Notices
The information contained herein is subject to change without notice. The only warranties for Hewlett
Packard Enterprise products and services are set forth in the express warranty statements accompanying
such products and services. Nothing herein should be construed as constituting an additional warranty.
Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained
herein.
Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession,
use, or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer
Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government
under vendor's standard commercial license.
Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard
Enterprise has no control over and is not responsible for information outside the Hewlett Packard
Enterprise website.
Acknowledgments
Microsoft® and Windows® are either registered trademarks or trademarks of Microsoft Corporation in the
United States and/or other countries.
Page 3
Contents
Planning the installation.........................................................................6
Component and LED identification..................................................... 13
Safety and regulatory compliance.................................................................................................6
Site requirements..........................................................................................................................6
Warning, caution, and important messages..................................................................................6
Determine power and cooling configurations................................................................................7
Power supply calculations..................................................................................................7
Power requirements........................................................................................................... 7
Space and airflow requirements................................................................................................... 8
Temperature requirements............................................................................................................8
Acronyms and abbreviations.............................................................101
Contents5
Page 6
Planning the installation
Safety and regulatory compliance
For important safety, environmental, and regulatory information, see Safety and Compliance Information
for Server, Storage, Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise
website (
Site requirements
Select an installation site that meets the detailed installation site requirements described in the site
planning guide on the Hewlett Packard Enterprise website (
WARNING: To reduce the risk of personal injury or damage to equipment, heed all warnings and
cautions throughout the installation instructions.
WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that:
•The leveling feet are extended to the floor.
•The full weight of the rack rests on the leveling feet.
•The stabilizing feet are attached to the rack if it is a single-rack installation.
•The racks are coupled together in multiple-rack installations.
•Only one component is extended at a time. A rack may become unstable if more than one
component is extended for any reason.
WARNING: The frame is very heavy. To reduce the risk of personal injury or damage to the
equipment:
•Observe local occupational health and safety requirements and guidelines for manual material
handling.
•Remove all installed components from the frame before installing or moving the frame.
•Use caution and get help to lift and stabilize the frame during installation or removal, especially
when the frame is not fastened to the rack.
WARNING: Always use at least four people to lift the frame into the rack. If the frame is being
loaded into the rack above chest level, a fifth person must assist with aligning the frame with the
rails while the other four people support the weight of the frame.
WARNING: Install the frame starting from the bottom of the rack and work your way up the rack.
6 Planning the installation
Page 7
These symbols, on power supplies or systems, indicate that the equipment is supplied
by multiple sources of power.
NOTE: To reduce the risk of injury from electric shock, remove all power cords to
completely disconnect power from the system.
•Each frame has two or more power supply cords. A single rack or cabinet may
contain more than one frame. Power may be supplied in a redundant fashion.
Removing any single source of power does not necessarily remove power from
any portion of the system. When performing any service other than hot-plug
module replacement, you must completely disconnect all power to that portion of
the system.
•When performing service procedures on frames, shut off the circuit breakers to
both A and B AC power feeds and then disconnect all power cords from the
outlets before servicing.
WARNING: To reduce the risk of electric shock or damage to the equipment, enter a frame or
perform service on system components only as instructed in the user documentation.
WARNING: A risk of electric shock from high leakage current exists. Before connecting the AC
supply to the power enclosure, be sure that the electrical outlets are properly grounded (earthed).
CAUTION: Always be sure that equipment is properly grounded and that you follow proper
grounding procedures before beginning any installation procedure. Improper grounding can result in
ESD damage to electronic components. For more information, see "Electrostatic discharge."
CAUTION: Protect the storage module from power fluctuations and temporary interruptions with a
regulating UPS. This device protects the hardware from damage caused by power surges and
voltage spikes and keeps the storage module in operation during a power failure.
Determine power and cooling configurations
Validate power and cooling requirements based on location and installed components.
For more information, see the HPE Synergy Configuration and Compatibility Guide on the Hewlett
Packard Enterprise website (http://www.hpe.com/info/synergy-docs).
Power supply calculations
For hot-plug power supply specifications, see the HPE Synergy QuickSpecs on the Hewlett Packard
Enterprise website (http://www.hpe.com/info/synergy-docs). There is also the Synergy Planning Tool
for download. The Synergy Planning Tool helps plan and organize all Synergy options to build a single
frame, multiple frame, or racks for a complete solution ready to order from HPE using a simple BOM from
the tool. The Synergy Planning Tool can be found on the Hewlett Packard Enterprise Sales Portal website
in the Tools section.
Power requirements
Installation of this equipment must comply with local and regional electrical regulations governing the
installation of IT equipment by licensed electricians. This equipment is designed to operate in installations
covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992 (code for Protection of
Determine power and cooling configurations7
Page 8
Electronic Computer/Data Processing Equipment). For electrical power ratings on options, refer to the
product rating label or the user documentation supplied with that option.
WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overload
the AC supply branch circuit that provides power to the rack. Consult the electrical authority having
jurisdiction over wiring and installation requirements of your facility.
CAUTION: Protect the storage module from power fluctuations and temporary interruptions with a
regulating UPS. This device protects the hardware from damage caused by power surges and
voltage spikes and keeps the storage module in operation during a power failure.
Space and airflow requirements
CAUTION: In high-density configurations, the HPE 11000 G2 Series Rack Airflow Optimization Kit
(BW930A) should be installed to prevent airflow from the rear of the rack to the front the rack via
gaps in the rack frame.
To enable servicing and ensure adequate airflow, observe the following spatial requirements when
deciding where to install a Hewlett Packard Enterprise-branded, Compaq-branded, Telco, or third-party
rack:
•Leave a minimum clearance of 63.5 cm (25 in) in front of the rack.
•Leave a minimum clearance of 76.2 cm (30 in) in back of the rack.
•Leave a minimum clearance of 121.9 cm (48 in) from the back of the rack to the rear of another rack or
row of racks.
Compute modules draw cool air in through the front and expel warm air through the rear of the frame.
Therefore, the front of the frame must be adequately ventilated to enable ambient room air to enter the
frame, and the rear of the frame must be adequately ventilated to enable the warm air to escape from the
frame.
Hewlett Packard Enterprise Advanced Series Racks, Hewlett Packard Enterprise Series Racks, and
Hewlett Packard Enterprise Standard Series Racks provide proper compute module cooling through flowthrough perforations in the front and rear doors that provide 65 percent open area for ventilation.
If the front of the rack is not completely filled with components, the remaining gaps between the
components can cause changes in the airflow, which can adversely affect cooling within the rack. Cover
these gaps with blanking panels.
IMPORTANT: Do not block the ventilation openings.
CAUTION: Always use blanking panels to fill empty vertical spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in improper cooling that can
lead to thermal damage.
Temperature requirements
To ensure continued safe and reliable equipment operation, install or position the rack in a well-ventilated,
climate-controlled environment.
8 Space and airflow requirements
Page 9
The operating temperature inside the rack is always higher than the room temperature and is dependent
on the configuration of equipment in the rack. Check the TMRA for each piece of equipment before
installation.
CAUTION: To reduce the risk of damage to the equipment when installing third-party options:
•Do not permit optional equipment to impede airflow around the frame or to increase the internal
rack temperature beyond the maximum allowable limits.
•Do not exceed the manufacturer’s TMRA.
Grounding requirements
This equipment must be grounded properly for proper operation and safety. In the United States, you
must install the equipment in accordance with NFPA 70, 1999 Edition (National Electric Code), Article
250, as well as any local and regional building codes.
In Canada, you must install the equipment in accordance with Canadian Standards Association, CSA
C22.1, Canadian Electrical Code.
In all other countries, you must install the equipment in accordance with any regional or national electrical
wiring codes, such as the International Electrotechnical Commission (IEC) Code 364, parts 1 through 7.
Furthermore, you must be sure that all power distribution devices used in the installation, such as branch
wiring and receptacles, are listed or certified grounding-type devices.
Because of the high ground-leakage currents associated with this equipment, Hewlett Packard Enterprise
recommends the use of a PDU that is either permanently wired to the building’s branch circuit or includes
a nondetachable cord that is wired to an industrial-style plug. NEMA locking-style plugs or those
complying with IEC 60309 are considered suitable for this purpose. Using common power outlet strips to
supply power to this equipment is not recommended.
Supported racks and rack options
The frame and support rails are engineered for mounting into a 19" wide front panel, 4-post cabinets, and
racks that have been designed according to the EIA-310-D standard.
Hewlett Packard Enterprise rails are not compatible with tapped holes. There are two types of supported
rail sets for the frame:
•A set for square-hole front and rear mounting flanges
•A set for round-hole flanges
The rails are compatible with a nominal rack-mounting depth of 29 1/8", with an adjustability range of plus
½" to minus 1 ½". The rails will work in both a 1075 mm and a 1200 mm deep rack.
A 42U/47U rack supports up to four frames.
While the square-hole rail set is the standard option, either rail set supports a fully loaded frame weighing
550 pounds. Four of these frames together approach the 2,250 pound internal IT equipment limit of both
the HPE 42U x 600 mm x 1075 mm and the 42U 600 mm x 1200 mm 11000G2 Series QS racks.
NOTE: The HPE Synergy 12000 Frame is deeper than the c7000 enclosure by approximately 3.5 inches.
1075 racks with side facing PDUs may interfere with the frame. Hewlett Packard Enterprise recommends
using 1200 mm racks.
Grounding requirements9
Page 10
Cables, PDUs, and other cable management hardware could increase the weight sufficiently to require
the use of the HPE 42U x 600 mm x 1200 mm Intelligent Series QS rack, which supports 2,750 pound
internal IT equipment.
Rack-free environment requirements
The HPE Synergy 12000 Frame (referred to as the frame) can be used in a rack-free environment. The
following conditions must be met when performing a rack-free installation:
•A fully-populated frame can weigh up to 249.50 kg kg ( 550.00 lb lb). The object supporting the frame
must be able to withstand this weight.
•The frame should be supported by a sturdy, flat surface.
WARNING: To reduce the risk of personal injury or damage to the equipment in a rack-free
environment:
◦Never stack the frame on top of another frame.
◦Never place equipment on top of the frame.
◦Never place the frame on a surface that cannot support up to 249.50 kg kg ( 550.00 lb lb).
HPE Synergy configuration
An initial setup for HPE Synergy requires planning the location for each component. To ensure a proper
configuration, review the information in the following documents on the Hewlett Packard Enterprise
website (http://www.hpe.com/info/synergy-docs):
•HPE Synergy Configuration and Compatibility Guide—This document helps to understand more about
each component and the configuration requirements for installing each component. It provides the
following:
◦An overview of HPE Synergy management and fabric architecture
◦Detailed hardware component identification
◦Hardware configuration guidelines
◦Interconnect, power, and HPE Synergy Console cabling information
•HPE Synergy Cabling Guide—This document provides detailed information and diagrams on how to
cable HPE Synergy.
10 Rack-free environment requirements
Page 11
Pallet contents
ItemNameDescription
1HPE Synergy 12000 FrameThe frame for installing Synergy
components
2Front panelThe front panel ports of the frame for
KVM connection
3Appliance module blankA mandatory insert installed in any
unused appliance module bay.
4Appliance module
1
A hardware appliance for embedded
management
5Compute module blankA mandatory insert installed in any
unused compute module bay.
6Full-height module
7Half-height module
1
1
The full-height compute module
The half-height compute module
8Power supply blankA mandatory insert installed in any
unused power supply bay
9Hot-plug power supply
1
The power supply for the frame
10FanA fan used to cool the components
installed in the frame
Table Continued
Pallet contents11
Page 12
ItemNameDescription
11Frame link module
1
The frame link module auto-discovers
resources in the frame, has a
redundant option, and provides links
for scaling of frames.
12Interconnect blankA mandatory insert installed in any
unused interconnect bay
13Interconnect module
2
Any of several fabric or networking
components, such as switches or
interconnect link modules, that enable
networking communication.
3
14
Lift handles (optional)The lift handles can be used to lift a
frame into or out of a rack.
3
15
Removable device bay shelvesThe removable device bay shelves can
be used to partition the device bays for
full or half-height components
3
16
Reusable zip ties for power supplies (singlephase frames only)
Reusable zip ties that help prevent
single-phase power cables from
disconnecting from the power
connectors
17
3
CAT6A cable
1
CAT6A cable for cabling frames
3
18
19
3
HPE Synergy Start Here posterThe quick setup poster provides an
Installation instructions for compute modules,
options, and interconnects
3
20
1
Quantity as ordered
2
Quantity and type as ordered
3
Not shown
HPE Synergy 12000 Frame Rack TemplateThe printed template for locating the
•2-ft cable—Used for cabling two
consecutive frames
•10-ft cable—Used for cabling the
top frame to the bottom frame in a
rack
•21-ft cable—Used for cabling
management links requiring long
runs to TOR
overview of the installation process.
The printed installation instructions for
Synergy components
positions of frames, rack rails, and
cage nuts in a rack.
12 Planning the installation
Page 13
Component and LED identification
Information pull tabs
Pull tabs on the HPE Synergy frame front and rear provide system information.
Figure 1: Information pull tab locations
ItemDescription
1The front pull tab (top left) has the frame product ID, serial number, and the device bay
numbering for the frame front bays.
2The rear pull tab (top left) has the bay numbering for the frame rear bays.
3
The serial label pull tab is on each compute module and provides the following
information:
•Product serial number
•iLO information
•QR code that points to mobile-friendly documentation
Component and LED identification13
Page 14
Figure 2: Accessing the information pull tabs
Mobile-ready content
The HPE Synergy 12000 Frame includes QR codes that point directly to the mobile-ready documentation
from your mobile device.
To access the mobile-ready content, such as setup, installation, user, or troubleshooting documentation,
use your mobile device to scan the product-specific QR code.
Mobile QR code locations
Mobile QR codes are located on HPE Synergy components and pull tabs and provide quick and efficient
access to product specific content for the component. The QR codes takes you to a page that allows you
to browse to the online documentation by choosing an HPE Synergy component.
Frame front components and device bays
14 Mobile-ready content
Page 15
ItemDescription
1Device bays—Compute modules and storage modules
2Front panel—Provides access to the HPE Synergy console, via KVM or laptop.
3Appliance bays
Device bay numbering
All device bays in the frame are numbered in consecutive order from lowest to highest, from left to right
from top to bottom, as observed by a user looking directly at the frame.
Devices larger than half-height (multi-bay devices) are numbered according to the lowest device bay
number that the multi-bay device occupies.
For an even number of device modules, they must be installed next to each other between sets of vertical
partitions if all device bays in the frame are to be used.
For an odd number of single-wide full-height device modules, an even number must be installed next to
each other between each vertical partition, and the odd module must be installed in device bay 2 if all
device bays in the frame are to be used.
The device bay numbering is available on the Information pull tabs.
Device bay typeDevice bay numbering
Single-wide, full-height
Single-wide, half-height
Single-wide, mixed-height
Double-wide, full-height
Double-wide, half-height
Double-wide, mixed-height
Device bay numbering15
Page 16
Device bay partitions
Vertical frame partitions
There are two vertical partitions between device bays in the frame. These nonremovable partitions
provide structural integrity to the frame as well as mechanical attach points for the horizontal shelf that
divide a full-height bay into two half-height bays.
Up to six full-height device modules can be installed in a frame.
Figure 3: Vertical partitions
Horizontal frame partitions
The horizontal frame partitions are removable shelves that divide a full-height device bay into a halfheight device bay.
Up to 12 half-height device modules can be installed in a frame.
Figure 4: Horizontal partitions
An optional horizontal half shelf can be installed between bay 1 and bay 7 to enable those bays to be
used by half-height device modules when a full-height module is installed in bay 2.
16 Device bay partitions
Page 17
Figure 5: Optional horizontal half-shelf
Front panel components
Front panel components17
Page 18
ItemDescriptionFunction
1UID buttonToggles the frame UID on or off.
2Frame Health LED
3Laptop port
4Monitor portProvides connectivity for a monitor or an active monitor port
5Reset buttonProvides two functions:
Indicates the highest severity health status of all components
within the frame.
•Solid green—Normal operation
•Flashing amber—Warning
•Flashing red—Critical error
To resolve critical errors, connect to HPE OneView or to the
HPE Synergy Console.
Provides single laptop access to the frame link module using an
RJ-45 Ethernet 100BASE-TX connection.
adapter to access the HPE Synergy Console.
•Resets the Active frame link module - momentary press.
•Factory resets both frame link modules - press and hold
until UID LED blinks blue.
NOTE: The reset button does not reset any other component
in the frame.
6USBProvides a connection for supported USB devices such as a
keyboard or mouse for HPE Synergy Console use. To connect
multiple devices, a USB hub (not included) is required.
Appliance module LEDs and components
Appliance module LEDs and components are the same for both an HPE Synergy Composer or an HPE
Synergy Image Streamer.
18 Appliance module LEDs and components
Page 19
ItemDescriptionFunction
1UID LED
2Health LED
3Activity LED
Press the UID button to turn on the blue locator LED.
•Solid blue—Illuminates to locate the appliance module
•Flashing blue—Indicates appliance module firmware
update. Do not power off or remove appliance module when
the UID LED is flashing.
Indicates the health of the appliance module
•Solid green—Normal operation
•Flashing amber—Warning
•Flashing red—Critical error
The appliance Health LED provides health status of the
appliance. If the Health LED indicates a warning or a critical
error, connect to the Synergy console to troubleshoot.
Indicates which appliance module is active
•Off—Indicates that the appliance module is the standby in a
Highly Available configuration or HPE OneView is in an error
state.
•Solid green—Indicates that the appliance module is active.
•Flashing green—Indicates that the reset button has been
pressed and held for greater than 10 seconds, which
initiates a reimaging of the appliance module. The active
LED does not continue to flash green during the reimaging
process.
Table Continued
Component and LED identification19
Page 20
ItemDescriptionFunction
4Power LED
5Reset button
6USB portUSB 3.0 port for connecting a USB drive to flash a USB
Appliance bay numbering
Indicates power to the appliance
•Off—No power. Verify that the appliance module is fully
inserted into the frame link module.
•Flashing amber—Appliance module is initializing.
•Solid amber—Appliance module is powered off.
•Solid green—Appliance module is powered on.
Using an applicator such as a paper clip, press the recessed
button to reset the appliance module.
•Press and release—Resets the appliance module.
•Press and hold until activity LED is flashing green—Initiates
reimaging of the appliance module from files on the USB
flash drive plugged into the appliance module.
recovery image.
20 Appliance bay numbering
Page 21
Frame rear components
ItemDescription
1Fans (10)
2Interconnect modules (up to 6)
3Power supplies (6)
4Frame link modules (2)
Rear component bay numbering
Frame rear components21
Page 22
ComponentsBaysLabels
Frame link modules1 and 2
Interconnect modules
These interconnect modules are
redundant pairs on fabric 1.
Interconnect modules
These interconnect modules are
redundant pairs on fabric 2.
Interconnect modules
These interconnect modules are
redundant pairs on fabric 3.
Fans1 through 10
Power supplies1 though 6
NOTE: The arrow direction on each of the power supply icons indicates the recommended power routing
to either A-side or B-side. For more information about A-side and B-side power distribution, see "Powercabling."
1 and 4
2 and 5
3 and 6
Frame link module components and LEDs
22 Frame link module components and LEDs
Page 23
ItemDescriptionFunction
1MGMT port activity
LED
2MGMT port
3MGMT port
connectivity LED
4Health LED
Reports MGMT port activity:
•Flashing green = Activity on the MGMT port
•Off = No activity on the MGMT port
A 10GBASE-T RJ45 connector that provides the following functions:
•Provides a management uplink to the management network.
•Provides a data connection to the data network when an Image
Streamer management appliance is installed in the frame.
•Automatically negotiates speed to 10GbE or 1GbE based on the
connection.
Reports MGMT port connectivity:
•Solid green = MGMT port is connected.
•Off = MGMT port is not connected.
Provides the health status of the frame link module.
•Solid green = Normal operation
•Flashing amber = Warning
•Flashing red = Critical error
If the Health LED indicates a warning or a critical error, connect to
HPE OneView or to the HPE Synergy Console for more information
and troubleshooting assistance.
5UID buttonToggles the UID LED on or off.
•Solid blue = Activated
•Off = Deactivated
•Flashing blue = Firmware upgrade is in progress on the frame link
module.
Do not remove either frame link module while the UID LED is flashing.
6USB
Allows connection to the frame using a supported USB device. Devices
include a keyboard or mouse for connecting to the HPE Synergy
Console. To connect multiple devices, a USB hub (not included) is
required.
Table Continued
Component and LED identification23
Page 24
ItemDescriptionFunction
7LINK port activity LEDReports LINK port activity:
•Flashing green = Activity on the LINK port
•Off = No activity on the LINK port
8LINK portA 10GBASE-T 1 RJ45 connector that provides two functions:
•Provides high availability management network connectivity
between:
◦LINK ports on two frame link modules in the same frame for a
single frame configuration
◦Frame link modules in different frames as part of a management
network ring in a multiframe configuration
•Provides connectivity as part of a management network ring which
connects multiple frames for automatic discovery by HPE OneView.
9LINK port connectivity
LED
10Monitor portAllows connection to the frame using a monitor device or an active
1
The 10GBASE-T MGMT port automatically negotiates speed to 10GbE or 1GbE based on the connection.
Power supply LED
Reports LINK port connectivity:
•Solid green = LINK port is connected.
•Off = LINK port is not connected.
monitor port adapter.
Power LEDCondition
OffNo input power to the power supply or power supply failure. Connect to
Solid greenNormal operation
Flashing amberWarning. Connect to HPE OneView Hardware Setup to troubleshoot.
24 Power supply LED
the HPE Synergy console and check for power supply error messages.
Page 25
Fan LED
LED colorFan status
Solid greenNormal operation
Flashing redCritical. Connect to HPE OneView Hardware Setup to troubleshoot.
Fan LED25
Page 26
Installation
Installing the Synergy system components
Procedure
1. Unpack the system.
2. Remove components from the frame.
3. For rack-free installations, set up the frame on an appropriate surface, and then install the frame
options.
4. For rack installations, install the frame into the rack, and then install the frame options.
5. Install the frame components into the frame.
6. Connect the frame components in the frame.
7. Connect the AC power cables and power up the frame.
8. Configure the frame using the Composer.
Removing components from the frame
Before installing the frame into the rack, you must remove all of the pre-installed components from the
front and rear of the frame. Since a fully-populated frame can weigh up to 249.50 kg kg ( 550.00 lb lb),
removing the components from the frame makes moving and installing the frame easier.
With the frame still on the pallet, remove all components from the front and rear of the frame.
IMPORTANT: To ensure the correct configuration when installing components, be sure to note the
location of each component before removing it from the frame.
26 Installation
Page 27
For specific instructions concerning removing the components, see the HPE Synergy 12000 Frame
Maintenance and Service Guide.
Installing the frame in a rack-free environment
WARNING: To reduce the risk of personal injury or damage to the equipment in a rack-free
environment:
•Never stack the frame on top of another frame.
•Never place equipment on top of the frame.
•Never place the frame on a surface that cannot support up to 249.50 kg kg ( 550.00 lb lb).
Procedure
1. Select the location for the frame. For more information, see "Rack-free environment requirements."
2. Remove components from the frame.
3. Place the frame on a flat, sturdy surface to support the frame.
4. Complete the component installation for your configuration.
Installing the frame in a rack
CAUTION: Always plan the rack installation so that the heaviest item is on the bottom of the rack.
Install the heaviest item first, and continue to populate the rack from the bottom to the top.
NOTE: Up to four 10U frames can be installed in a 42U rack. If you are installing more than one frame,
install the first frame in the bottom of the rack, and then install additional frames by moving up the rack
with each subsequent frame. Plan rack installation carefully because it is difficult to change the location of
components after they are installed.
Installing the frame in a rack-free environment27
Page 28
Procedure
1. Remove components from the frame.
2. Use the rack template to mark the locations for the rack rails.
3. Install the rack rails and cage nuts for each frame.
For more information, see the appropriate section according to the type of rack being used.
4. Install the frame into the rack.
5. Complete the component installation for your configuration.
Measuring with the rack template
The HP Synergy 12000 Frame Rack Template ships with the frame and provides detailed instructions on
where to position the frame and rack rails, and where to install the cage or clip nuts. Each frame kit
includes the rack rails recommended for that frame.
NOTE: Four cage nuts and four clip nuts are included with the frame. Cage nuts should be used in racks
with square holes. Clip nuts should be used in racks with round holes.
When installing multiple frames, install the rack rails and cage nuts for one frame, and then install the
frame. Repeat for each additional frame.
Procedure
1. Install lower cage nuts (left and right) in the front of the rack at the bottom of the fourth U (10 holes up
on the template).
2. Install the upper cage nuts (left and right) in the front of the rack at the bottom of the tenth U (28 holes
up on the template).
3. Install the rack rails.
Installing the rack rails for a square-hole rack
Rack rails are marked "LEFT" and "RIGHT" for identification. The rail release levers are used only when
removing the rail from the rack.
28 Measuring with the rack template
Page 29
Procedure
1. Begin with the left rack rail. Shorten the rail.
2. Align the rear end of the rail with the rack rear column.
3. Position the rail tabs next to the square openings in the rack rear column.
4. Keeping the rail level, insert the rear rail tabs into the rack rear column, and push the tabs down into
place.
5. Extend the front of the rack rail to the rack front column.
6. Position the rail tabs next to the square openings in the rack front column.
7. Insert the front rail tabs into the rack front column and push the tabs down into place.
Installation29
Page 30
8. Repeat the procedure for the right rack rail.
The installation is complete.
Installing the rack rails for a round-hole rack
Procedure
1. Align and install the rails in the rack.
2. Repeat the procedure for the other rail.
To remove the rails, reverse the installation procedure.
30 Installing the rack rails for a round-hole rack
Page 31
Installing the frame into the rack
WARNING: Always use at least four people to lift a frame into the rack. If the frame is being loaded
into the rack above chest level, a fifth person must assist with aligning the frame with the rails while
the other four people support the weight of the frame.
NOTE: You can install the frame into the rack using a mechanical lift. If you choose the mechanical lift
installation, resume the frame installation at step 5.
Procedure
1. Attach the lift handles to the frame.
a. Align each lift handle to the frame spools.
b. Press the release button, and then pull the lift handle up until it locks in place.
2. Line up the frame with the rack, set the back end of the frame on the rack rails and slide it in.
Installing the frame into the rack 31
Page 32
3. Slide the frame into the rack until the rear lift handles are close to the rack. While still supporting the
frame with the front lift handles, remove the rear lift handles from each side of the frame, and then
slide the frame halfway into the rack.
4. Slide the frame into the rack until the front lift handles are close to the rack. Remove the front lift
handles from each side of the frame, and then slide the frame fully into the rack.
32Installation
Page 33
5. Remove the left and right frame bezels from front of the frame by inserting your finger in the hole at
the bottom of the frame bezel and pull out and up, then pull the top of the frame bezel away from the
frame.
6. Tighten the thumbscrews with a T-25 Torx screwdriver to secure the frame to the rack.
Installation33
Page 34
7. Repeat the procedure for the remaining frames.
NOTE: Up to four 10U frames can be installed in a 42U rack. If you are installing more than one frame,
install the first frame in the bottom of the rack, and then install additional frames by moving up the rack
with each subsequent frame. Plan rack installation carefully because it is difficult to change the
location of components after they are installed.
Component installation
The following sections contain installation instructions for the individual frame components. The images
included in these instructions are intended to illustrate how the components are installed. These images
are not intended to indicate the location for installation. Install the component in the bay from which it was
removed earlier in this document.
There is no specific installation order requirement for the frame components, however Hewlett Packard
Enterprise recommends installing all front components first, followed by all rear components.
All components must be installed and cabled before you power up the frame.
The frame and components automatically power on when power is connected.
Installing an appliance module
The appliance modules have specific population guidelines based on the appliance module and the
system configuration. As a best practice, if two appliance modules of the same type exist in any group of
linked frames, install the appliance modules in separate frames.
After all components are installed and cabled, be sure to reimage the appliance module before bringing
the appliance module into your HPE Synergy configuration. Updating the firmware, ensures that the
appliance module is compatible with the HPE Synergy Software Release installed on HPE Synergy. For
more information, see Firmware.
Procedure
1. If installed, remove the appliance module blank from the appliance bay.
34 Component installation
Page 35
2. Install the first appliance into appliance bay 1.
When the appliance is fully seated, it locks into place.
Installing compute modules
Depending on the compute modules for your frame:
•Install device bay partitions
•Install a full-height compute module
•Install a half-height compute module
Installing a full-height compute module
The HPE Synergy 12000 Frame ships with three device bay shelves installed to support a 12 half-height
compute module configuration. To install a full-height compute module, remove the device bay shelves
and corresponding blanks.
Installing compute modules 35
Page 36
Procedure
1. Remove the blanks.
2. Remove the device bay shelf.
NOTE: Keep the compute module end caps, blanks, and device bay shelves for future use.
3. Remove the compute module end cap.
4. Prepare the compute module for installation.
5. Prepare the compute module for installation by opening the compute module handle.
36Installation
Page 37
6. Install the compute module. Press the compute module handle near each release button to completely
close the handle.
CAUTION: To prevent improper cooling and thermal damage, do not operate the compute
module or the frame unless all device bays are populated with either a component or a blank.
7. Install blanks in any empty bays.
Removing a device bay shelf
Procedure
1. Press and hold the release latches to release the locking mechanism.
2. Slide the removable shelf out of the frame.
Installation37
Page 38
Creating a full-height module bay blank
Procedure
1. Obtain the coupler plate:
•If you are using a module bay blank that came with the frame, the coupler plate can be found with
the contents of the full-height device shipping box.
•If you are using a device bay blank that you purchased as an option, remove the coupler plate from
inside the blank.
2. Fit the coupler plate into the slots on top of the blank, and then slide the coupler plate back until it
snaps into place.
3. Fit the slots on the bottom of the second blank on to the coupler plate tabs, and then slide the second
blank forward until it snaps in place.
38Installation
Page 39
4. Install the full-height blank into the device bay.
Installing a half-height compute module
Procedure
1. Remove the blank.
2. If required, install the device bay shelf.
NOTE: Keep the compute module end caps, blanks, and device bay shelves for future use.
3. Remove the compute module end cap.
Installing a half-height compute module 39
Page 40
4. Prepare the compute module for installation by opening the compute module handle.
5. Install the compute module. Press the compute module handle near the release button to completely
close the handle.
40Installation
Page 41
Installing a device bay shelf
The frame has a slot and notch on the device bay walls that is used to guide the shelf when inserted.
Procedure
1. Locate the slot and notch shelf guides.
2. Press and hold the latches of the removable shelf and insert into the device bay using the shelf
guides.
Installation41
Page 42
3. Once fully inserted, release the latches to lock in place.
Installing a frame link module
Procedure
1. If installed, remove the frame link module blank from the frame link module bay in the rear of the
frame.
CAUTION: Use caution when installing the frame link module into the frame to avoid damage to
the connector. Installing a frame link module with a damaged connector can result in damage to
the midplane.
2. Remove the frame link module end cap.
3. Insert the frame link module into the frame.
4. Close the frame link module latch.
42 Installing a frame link module
Page 43
Installing the storage module
Procedure
1. Prepare the storage module for installation by pressing down on the storage module handle release
latch, which opens the storage module handle.
NOTE: The storage module handle arrives packaged in the closed position and must be opened prior
to inserting into the frame.
2. Install a storage module by sliding it into the frame. Push the storage module handle to the closed
position until it clicks into place.
3. Press the driver drawer release latch and pull out the drawer with the driver drawer release handle.
4. Install a replacement/new drive, and then close the drive drawer.
Installing the storage module43
Page 44
Installing fans
All ten fans must be populated at all times. There is no required installation order for installing the fans.
To install a fan, insert the fan into the frame until it locks into place.
CAUTION: Use caution to avoid hitting the PCA card edge against the frame. Damage to the fan
PCA could result in malfunction of the fan or the frame.
After power is applied to the frame, verify each fan LED is green.
Installing interconnect modules
There are six single-wide interconnect bays in the frame. Installation in the interconnect bays depends on
the type of mezzanine card installed in the compute module and in which mezzanine slot the mezzanine
card was installed.
IMPORTANT: If the mezzanine card is not installed properly or the interconnect module installation
does not coincide with the mezzanine card installation, the ports on the interconnect module will not
function.
NOTE: For more information on how and where to install mezzanine cards, see the compute module user
guide or the system configuration guide.
Procedure
1. Review the interconnect mapping before selecting the ICM bay to install the interconnect module.
2. If installed, remove the interconnect blank.
44 Installing fans
Page 45
3. Remove the interconnect module end cap.
4. Install the interconnect module, and close the release lever.
Installation45
Page 46
Interconnect module configurations
The HPE Synergy 12000 Frame supports a pair of redundant interconnect modules for each of the three
fabrics. Hewlett Packard Enterprise recommends the following best practices:
•Fabric 1 primary use—Storage
•Fabric 2 primary use—Storage or networking
•Fabric 3 primary use—Networking
NOTE: Though each fabric has a recommended primary use, it is not required to use the primary use
case. If a fabric is not being used for its primary use, it can still be used for another purpose, within the
allowances.
FabricUsageICM description
Fabric 1
ICM Bays 1 and 4
Brocade 16 Gb/12 Fibre Channel SAN Switch Module
Brocade 16 Gb/24 Fibre Channel SAN Switch Module
HPE Virtual Connect SE 16Gb FC Module for HPE
Fabric 2
ICM Bays 2 and 5
Brocade 16 Gb/24 Fibre Channel SAN Switch Module
46 Interconnect module configurations
Storage
(Primary)
StorageBrocade 16 Gb/12 Fibre Channel SAN Switch Module
HPE Synergy 12Gb SAS Connection Module
for HPE Synergy
for HPE Synergy
Synergy
for HPE Synergy
for HPE Synergy
Table Continued
Page 47
FabricUsageICM description
HPE Virtual Connect SE 16Gb FC Module for HPE
Synergy
Fabric 2
ICM Bays 2 and 5
HPE Virtual Connect SE 40Gb F8 Module for HPE
HPE Synergy 20Gb Interconnect Link Module
HPE Synergy 10Gb Interconnect Link Module
HPE Synergy 10Gb Pass-Thru Module
Fabric 3
ICM Bays 3 and 6
HPE Virtual Connect SE 40Gb F8 Module for HPE
HPE Synergy 20Gb Interconnect Link Module
HPE Synergy 10Gb Interconnect Link Module
HPE Synergy 10Gb Pass-Thru Module
Brocade 16 Gb/12 Fibre Channel SAN Switch Module
NetworkingHPE Synergy 40Gb F8 Switch Module
Synergy
Networking
(Primary)
HPE Synergy 40Gb F8 Switch Module
Synergy
for HPE Synergy
Brocade 16 Gb/24 Fibre Channel SAN Switch Module
for HPE Synergy
Always adhere to the following guidelines when planning and installing the interconnect modules in HPE
Synergy frames:
•The interconnect modules are listed in order of priority from top to bottom within a fabric. For example,
if the HPE Synergy 12Gb SAS Connection Module is installed, it is only supported in fabric 1 and
therefore, that fabric solution is the first priority for fabric 1. If the HPE Synergy 12Gb SAS Connection
Module is not used, then fabric 1 is available to be used by one of the supported HPE Synergy Fibre
Channel interconnect modules. For more information about HPE Synergy 12Gb SAS Connection
Module configuration, see the HPE Synergy Configuration and Compatibility Guide on the Hewlett
Packard Enterprise website (http://www.hpe.com/info/synergy-docs).
•Both ICM bays within a fabric must contain the same interconnect module, unless the fabric is a
Master/Satellite fabric. In a Master/Satellite fabric, one or more satellite modules can be used along
with a master module to form a fabric.
•All interconnect link modules that comprise a Master/Satellite fabric must be installed in the same
interconnect bay number as the corresponding master interconnect module. For example, given a
three-frame configuration where the master interconnect module is installed in ICM bay 3 in one
frame, the two satellite interconnect link modules in the second and third frames must also be installed
in ICM bay 3.
Master interconnect module with interconnect link module configurations
The HPE Synergy Virtual Connect SE 40 Gb F8 Module or the HPE Synergy 40Gb F8 Switch Module can
be configured as the master switch, with interconnect link modules to support the master interconnect
Installation47
Page 48
module. For the HPE Synergy 10Gb Interconnect Link Module, from one to four interconnect link modules
are required to support the master interconnect module. For the HPE Synergy 20Gb Interconnect Link
Module, from one to two interconnect link modules are required to support the master interconnect
module.
If redundancy is required, then two master switches are required per fabric. For the best availability with
two or more frames, the two switches or VC modules should be installed in different frames.
As an example of a redundant fabric 3 solution, one interconnect module or VC module would be installed
in ICM bay 3 in one frame and the second interconnect module or VC module would be installed in ICM
bay 6 in another frame. ICM bays for the particular fabric that do not contain the interconnect modules or
VC modules would contain the interconnect link modules, providing redundancy for either a interconnect
module failure or frame failure.
Use one interconnect link cable to connect a 10 Gb interconnect link modules to the switch interconnect.
Use two interconnect link cables to connect 20 Gb interconnect link modules to the switch interconnect.
Mezzanine to frame signal routing
The HPE Synergy 12000 Frame midplane provides 4-lane high speed signal routing from all 12 device
bays to the 6 interconnect module bays. A pair of interconnects installed in an interconnect bay set
provide redundant connectivity for each connected mezzanine card. When a device bay contains a
compute module, then each of the installed mezzanine cards connect to the corresponding interconnect
bay sets.
48 Mezzanine to frame signal routing
Page 49
Usage of these interconnections is dependent on the type of fabric chosen to be installed. For example, a
10Gb Ethernet mezzanine card uses only a single lane of each four-lane group. The SAS fabric uses all
four lanes.
Interconnect port mapping
The following compute module device bays map to the interconnect module fabrics. This information is
located on the frame pull tabs.
The location of a mezzanine option in the compute module dictates the location of the corresponding
interconnect module in the rear of the frame.
NOTE: The compute module hood label includes the exact mezzanine card locations.
FabricInterconnect
bay sets
The symbols in the image correspond with symbols on the rear of the frame.
ItemMezz slot connector
identification
1Mezzanine slot 1 (M1)Type C and Type D1ICM 1 and 4
2Mezzanine slot 2 (M2)
3Mezzanine slot 3 (M3)Type C only3ICM 3 and 6
4Mezzanine slot 4 (M4)Type C and Type D1ICM 1 and 4
5Mezzanine slot 5 (M5)
6Mezzanine slot 6 (M6)Type C3ICM 3 and 6
1
When installing a mezzanine option in mezzanine slot 2, processor 3 must be installed. When installing a mezzanine
option in mezzanine slot 5, processor 4 must be installed.
Installing power supplies
WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply or power
WARNING: To reduce the risk of electric shock or damage to the equipment, do not connect the
power cord to the power supply until the power supply is installed.
Procedure
1. Remove the power supply blank, or unplug the power cord and remove the power supply from the
frame.
2. Remove the output connector cover from the new power supply.
3. Insert the power supply into the frame until it locks into place. The power supply is marked with TOP to
ensure proper orientation during installation.
4. Connect the power cord to the power supply.
5. Secure the power cord using the reusable zip tie attached to the power supply.
Installation51
Page 52
6. Connect the power cord to the power source.
7. Check the power supply LEDs to determine the status of the power supply.
Power supply configurations
Sufficient power supplies must be installed to support the installed devices and interconnect modules.
Power estimates for HPE Synergy can be provided using either the HPE Synergy Planning Tool or the
HPE Power Advisor. For more information about the HPE Power Advisor or the HPE Synergy Planning
Tool, see the Data Center Infrastructure Advisor page (https://dcia.itcs.hpe.com/).
The number of supported power supplies in the frame range from a minimum of two to a maximum of six
power supplies. There are no power supply bay placement restrictions of power supplies in the frame.
However, for best cooling and power distribution, Hewlett Packard Enterprise recommends the following
best practice for power supply usage.
NOTE: The default power mode is Redundant power feed mode.
Number of power
Power modes
supplies
1
2
Not supported
Redundant power supply mode
Redundant power feed mode
1
3
4
Redundant power supply mode
Redundant power supply mode
Redundant power feed mode
1
5
6
Redundant power supply mode1(A), 2(A), 3(A), 4(A), and 6(A)
Redundant power supply mode
Redundant power feed mode
52 Power supply configurations
Power supply bay (Power feed)
—
1(A) and 3(A)
1(A) and 3(B)
1(A), 3(A), and 5(A)
1(A), 3(A), 4(A), and 6(A)
1(A), 3(B), 4(A), and 6(B)
1(A), 2(A), 3(A), 4(A), 5(A), and 6(A)
1(A), 2(A), 3(B), 4(A), 5(B), and 6(B)
Page 53
1
If an odd number of power supplies are installed in a frame that is configured for redundant power feed mode, all
power supplies are providing power to the frame, but the capacity of the odd power supply is not used to determine
the overall power capacity of the frame.
To enhance cooling, populate all power supply bays with either a power supply blank or a power supply.
Power supply configuration recommendations for the frame do not depend on the type of power supply
being used. However, all power supplies must be of the same type. Mixed-type power supply
configurations are not supported.
Installing a DC power supply
WARNING: To reduce the risk of electric shock, be sure that the cable grounding kit is properly
installed and connected to a suitable protective earth terminal before connecting the power source
to the frame.
Prerequisites
•Be sure that a ground connection to the HPE Synergy 12000 Frame has been properly installed. See
Installing the DC power grounding kit or the document that ships with the kit.
•Gather the following tools:
◦Torx T25 screwdriver
◦Crimper
Procedure
1.Place the power supply on a flat, level surface.
2.Open the input connector on the new power supply by lifting the input connector cover.
3.Crimp a two-hole lug onto the -48V DC cable.
4.Insert the two-hole lug through the aperture labeled "-48V" on the power supply input connector.
5.Secure the two-hole lug to the -48V DC input connector terminal with two screws.
Installing a DC power supply53
Page 54
6.Using a torque-controlled T25 screwdriver, tighten both screws to 15lb-in of torque.
7.Crimp a two-hole lug onto the return cable.
8.Insert the two-hole lug through the aperture labeled "RTN" on the power supply input connector.
9.Secure the two-hole lug to the RTN input connector terminal with two screws.
10. Using a torque-controlled T25 screwdriver, tighten both screws to 15lb-in of torque.
11. Close the input connector cover.
12. Remove the output connector cover from the new power supply.
13. Insert the power supply into the frame until it locks into place. The power supply is marked with TOP
to ensure proper orientation during installation.
54Installation
Page 55
14. Connect the power cables to the -48V DC power source.
15. Turn on or enable the -48V DC power source.
16. Verify that the power supply LED is green.
Warnings and cautions
WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply or power
supply blank to cool before touching it.
WARNING: To reduce the risk of electric shock or damage to the equipment, do not connect the
power cord to the power supply until the power supply is installed.
CAUTION: To prevent improper cooling and thermal damage, do not operate the frame unless all
bays are populated with either a component or a blank.
Installing the DC power grounding kit (no bracket)
For clarity, the rack is not shown in the images of this procedure.
Prerequisites
The following tools are required to complete this procedure:
•T-30 Torx screwdriver
•8 mm socket wrench
Procedure
1. Using one hex thread-forming screw and lock washer, connect the grounding cable to the frame.
Tighten the screw to 15lb-in of torque.
Warnings and cautions55
Page 56
2. Using the screw supplied with the rack, connect the grounding cable to the grounding rail.
Installing the DC power grounding kit (with bracket)
For clarity, the rack is not shown in the images of this procedure.
Prerequisites
The following tools are required to complete this procedure:
•T-15 Torx screwdriver
•8 mm socket wrench
Procedure
1. Using the 2 hex thread-forming screws, install the bracket on the frame.
56 Installing the DC power grounding kit (with bracket)
Page 57
Tighten the screws to 15lb-in of torque.
2. Use two nuts to connect the cable to the bracket.
3. Using the screw supplied with the rack, connect the cable to the grounding rail.
Installation57
Page 58
Cabling the frame
WARNING: To reduce the risk of electric shock or injury due to high-current electrical energy, be
sure that all power is completely disconnected at the source before beginning any power
connections to the power bus bars or power bus box.
WARNING: Be sure that all circuit breakers are locked in the off position before connecting any
power components.
Procedure
1. Connect the power cables. Connect to the power source in your facility to each of the installed power
supplies, and power up the frame.
For more information, see Power cabling on page 67.
2. Connect the network cables.
For more information, see Network cabling on page 59.
3. Connect to the Synergy console.
For more information, see Connect to the HPE Synergy Console on page 69.
58 Cabling the frame
Page 59
Cabling
HPE Synergy Cabling Guide
For additional cabling scenarios and diagrams, see the HPE Synergy Cabling Guide (
www.hpe.com/info/synergy-cabling-guide).
The HPE Synergy Cabling Guide includes:
•Multiframe cabling
•HPE Image Streamer cabling
•CAT6A patch panel LINK port cabling
•Master to satellite Interconnect cabling
•Power cabling
•HPE Synergy Console cabling
Network cabling
To ensure the frame and installed components are connected to the network, the following connections
are required:
•Single-frame management network cabling example on page 59
•Master and satellite interconnect module cabling on page 60
http://
Single-frame management network cabling example
This example shows cabling a single frame with two HPE Synergy Composers and two frame link
modules installed in the frame.
NOTE: For high availability, Hewlett Packard Enterprise recommends installing two HPE Synergy
Composers.
NOTE: Use a minimum of CAT6A patch cables for LINK port cabling.
NOTE: Do not connect frame link module LINK ports to a data center switch.
Procedure
1. Connect the MGMT ports on both frame link modules to the external management network.
2. Connect the LINK ports together.
Cabling59
Page 60
Figure 6: Single-frame cabling example
Master and satellite interconnect module cabling
HPE Synergy supports a composable fabric that spans multiple frames and includes master interconnect
modules (switches) and satellite modules (links). If your HPE Synergy configuration has a composable
fabric, Hewlett Packard Enterprise recommends cabling the HPE Synergy Ethernet interconnect modules
in a master switch configuration, so that multiple interconnect link modules can support the master
interconnect module.
HPE OneView considers all Synergy frames that share the Virtual Connect connectivity through satellite
interconnect link modules to be a single Logical Enclosure.
To cable switch modules to interconnect link modules, use the examples that follow or see the installation
instructions provided with the interconnect link module.
Master interconnect module with 10G interconnect link module cabling example
1. In a multiframe system, connect either the HPE Synergy 40Gb F8 Switch Module or the HPE Virtual
Connect SE 40Gb F8 Module for HPE Synergy as the master to a satellite HPE Synergy 10Gb
Interconnect Link Module in a different frame.
Using interconnect link cables, connect the L1, L2, L3, or L4 ports on the master to the L1 port on
each satellite.
60 Master and satellite interconnect module cabling
Page 61
Figure 7: Cabling the interconnect modules in a five-frame system
2. In a single-frame or multiframe system, connect both masters with two stacking cables:
a. Connect a stacking cable from port Q7 on the first master to port Q7 on the second module.
b. Connect a stacking cable from port Q8 on the first master to port Q8 on the second module.
The examples shown use the HPE Virtual Connect SE 40Gb F8 Module for HPE Synergy. The cabling
varies depending on the modules being stacked.
Cabling61
Page 62
Figure 8: Multi-frame stacking example
62Cabling
Page 63
Figure 9: Single-frame stacking example
Master interconnect module with 10G interconnect link module configuration
AttributeValueDescription
Maximum compute modules5Each network is a single
physical switch/hop
Maximum half-height compute modules60Each network has 1:1 OSR
between servers
Satellite links (CXP) per interconnect module1Each switch can connect to
four 10G interconnect link
modules
Stacking ports (QSFP+)4Can also be used for non-
Flex uplinks
Uplink ports (QSFP+)12Flexports: 4 x 10G, 1 x 40
G, 4 x 2/4/8G FC
Uplink oversubscription
2.25:1
1.88:1
2.25:1 if using only Flexport
uplinks
1.88:1 if also using non-Flex
stacking ports as uplinks
Table Continued
Cabling63
Page 64
AttributeValueDescription
Maximum stacked switches8# of switches (interconnect
modules do not count
towards limit)
Maximum redundant fabrics per frame3Redundant fabrics 1, 2, and
3 (A and B)
Components:
1
Number of switches2
Number of 10 G interconnect modules8
Number of interconnect link cables8Cable lengths allow frames
to be in different racks
Number of QSFP+ stacking cables2In this use case, QSFP+
ports are used for stacking
Number of 10 G mezzanine cards60Maximum for 60 compute
module (five frame)
deployment
1
Double component counts for two redundant fabrics, and triple component counts for three redundant fabrics.
Master interconnect module with 20G interconnect link module cabling example
1. In a multiframe system, connect either the HPE Synergy 40Gb F8 Switch Module or the HPE Virtual
Connect SE 40Gb F8 Module for HPE Synergy as the master to a satellite HPE Synergy 20Gb
Interconnect Link Module in a different frame:
a. Using interconnect link cables, connect one of the L1 and L4 ports on the master to the L1 and L2
ports on one satellite.
b. For a three-frame system, use interconnect link cables to connect the L2 and L3 ports on the same
master to the L1 and L2 ports on the other satellite.
64 Master interconnect module with 20G interconnect link module cabling example
Page 65
Figure 10: Cabling the interconnect modules in a three-frame system
2. In a single-frame or multiframe system, connect both masters with two stacking cables:
a. Connect a stacking cable from port Q7 on the first master to port Q7 on the second module.
b. Connect a stacking cable from port Q8 on the first master to port Q8 on the second module.
The examples shown in this section use the HPE Virtual Connect SE 40Gb F8 Module for HPE
Synergy. The cabling varies depending on the modules being stacked.
Figure 11: Multiframe stacking example
Cabling65
Page 66
Figure 12: Single-frame stacking example
Master interconnect module with 20G interconnect link module configuration
AttributeValueDescription
Maximum compute modules3Each network is a single
physical switch/hop
Maximum half-height compute modules36Each network has 1:1 OSR
between servers
Satellite links (CXP) per interconnect module 2Each switch can connect to two
20 G interconnect link modules
Stacking ports (QSFP+)4Can also be used for non-Flex
uplinks
Uplink ports (QSFP+)12Flexports: 4 x 10G, 1 x 40 G, 4
x 2/4/8G FC
Uplink oversubscription
66Cabling
3:2
3:2
3:2 if using only Flexport uplinks
3:2 if also using non-Flex
stacking ports as uplinks
Table Continued
Page 67
AttributeValueDescription
Maximum stacked switches8# of switches (interconnect
Maximum redundant fabrics per frame3Redundant fabrics 1, 2, and 3
Components:
Number of switches2
Number of 20 G interconnect modules4
Number of interconnect link cables8Cable lengths allow frames to
Number of QSFP+ stacking cables2In this use case, QSFP+ ports
Number of 20 G mezzanine cards36Maximum for 36 compute
1
Double component counts for two redundant fabrics, and triple component counts for three redundant fabrics
1
Power cabling
modules do not count towards
limit)
(A and B)
be in different racks
are used for stacking
module (two or three frame)
deployment
The frame can be cabled for power feed redundancy or power supply redundancy.
Cabling power supplies for power feed redundancy
Power feed redundancy may be achieved by connecting 1+1, 2+2, or 3+3 power supplies to Phase A+B.
To cable a frame for power feed redundancy, use the following recommendation as a best practice:
1. Connect power supplies 1, 2, and 4 to the A-side power distribution unit.
2. Connect power supplies 3, 5, and 6 to the B-side power distribution unit.
3. Verify that the power supply cords are securely connected using the reusable cable tie wraps.
Power cabling67
Page 68
After power is supplied to the frame, it powers up automatically. The power and health LEDs on the front
panel, Composer appliance, and frame link modules illuminate green to indicate that there are no errors
or alert conditions.
Cabling multiple frames for power feed redundant power
To cable multiple frames for redundancy using best practices, review the following example of a
redundant power feed configuration.
Your configuration can vary depending on the PDUs installed.
68 Cabling multiple frames for power feed redundant power
Page 69
Figure 13: Multiframe redundant power feed configuration
Connect to the HPE Synergy Console
You can connect to the HPE Synergy console using a notebook computer or a keyboard, video monitor,
and mouse.
The HPE Synergy console provides access to HPE OneView running on an HPE Synergy Composer
appliance.
The HPE Synergy console also provides access to the serial console for modules installed within a frame,
including management appliances, interconnects, or compute modules. To access the serial console for a
module, connect to the HPE Synergy console via ports in the same frame as the module.
When installing an HPE Synergy system, to access HPE OneView, connect to the HPE Synergy console
via ports in a frame that has an HPE Synergy Composer appliance. After all frames in an HPE Synergy
system have been claimed during hardware setup, you can connect to any frame to access HPE
OneView through the HPE Synergy console.
Connect to the HPE Synergy Console69
Page 70
Connecting to the HPE Synergy Console using a keyboard, video monitor,
and mouse
NOTE: This procedure describes connecting a keyboard and mouse to a monitor with an integrated USB
hub. Alternatively, you can use a standalone USB hub to connect a keyboard and mouse.
Prerequisites
A frame link module is installed in a frame link module bay.
Procedure
1. Connect a monitor cable to the monitor port and connect a USB cable to the USB port on either:
•The Front panel module on the front of the frame.
•One of the Frame Link Modules on the rear of the frame.
70 Connecting to the HPE Synergy Console using a keyboard, video monitor, and mouse
Page 71
2. Connect a monitor to the frame with the monitor cable.
3. Connect a USB keyboard and mouse to the USB ports on the monitor, and connect the monitor USB
to the frame with the USB cable.
An alternative is to connect the USB keyboard and mouse to a USB hub connected to the frame.
Connecting to the HPE Synergy Console using a laptop computer
NOTE: Do not plug the front panel laptop port into a switch. The front panel laptop port is designed to
provide a single laptop access to HPE Synergy Console.
Prerequisites
At least one frame link module is installed in one of the frame link module bays.
Procedure
1. Ensure that the Ethernet port of the laptop computer is configured for DHCP.
Alternatively, you can configure the laptop Ethernet port to the IP address: 192.168.10.2 with the
subnet mask 255.255.255.0.
2. Use a CAT5 cable to connect the laptop computer Ethernet port to the laptop port on a front panel
module.
Connecting to the HPE Synergy Console using a laptop computer71
Page 72
3. Wait for the laptop computer to be assigned an IP address from the frame link module.
4. Access the HPE Synergy Console using either a VNC client or web browser.
a. Web browser: Open a web browser and enter "http://192.168.10.1:5800".
b. VNC client: Open a VNC client and connect to 192.168.10.1 port 5900.
A VNC client will load to the web browser and open the HPE Synergy Console.
72Cabling
Page 73
Firmware
Reimage the appliance module
Before performing a first-time setup of an HPE Synergy appliance module, you must update the appliance
module firmware. By updating the firmware on the appliance module, you ensure that it is compatible with
the HPE Synergy software release.
When setting up HPE Synergy for the first time, the appliance firmware must be compatible with the HPE
Synergy software release that is selected. When installing an appliance module in an existing HPE
Synergy, then the following must be true:
•The appliance module firmware is compatible with the HPE Synergy software release on HPE
Synergy.
•The appliance module firmware is the same version installed on other appliance modules of the same
type installed in HPE Synergy.
For more information, see Validating HPE Synergy appliance firmware on the Hewlett Packard Enterprise
website (
Updating the firmware for the frame components
http://www.hpe.com/info/synergy-fw-validation).
After all the hardware components are installed and connected to power, update the firmware on all
components as required. Some components, such as appliance modules and compute modules, have
specific requirements to ensure compatibility.
When installing new appliance modules in a frame that will be added to an existing management ring,
always update the appliance module firmware to match the firmware version of the other appliance
modules in the management ring. For more information, see Validating HPE Synergy appliance firmware
on the Hewlett Packard Enterprise website (http://www.hpe.com/info/synergy-fw-validation).
For more information about updating the firmware for HPE Synergy, see the Best Practices for HPE
Synergy Firmware and Driver Updates on the Hewlett Packard Enterprise website (http://www.hpe.com/
info/synergy-docs).
Firmware73
Page 74
Configuring HPE Synergy
Configuring the frame overview
Procedure
1. Verify the component installation is complete.
Review the component health on the Synergy Console Frame Health & Inventory screen.
2. Verify the frame is cabled.
For more information, see "Cabling the frame on page 58."
To test management port connections in the a ring, perform a MGMT Port Test. For more information,
see the HPE Synergy Frame Link Module User Guide at http://www.hpe.com/info/synergy-docs.
3. Verify the frame is powered up.
4. Connect to HPE OneView through the HPE Synergy console.
To access the Synergy console, you must connect locally to a frame with a Composer installed. For
more information, see "Connect to the HPE Synergy Console on page 69."
5. Use HPE OneView to verify the hardware installation.
For more information, see "Verifying installation using HPE OneView on page 76."
6. Complete the hardware setup in HPE OneView.
Synergy Console Frame Health & Inventory screen
The Frame Health & Inventory screen displays the health status of all components in a frame.
74 Configuring HPE Synergy
Page 75
ItemDescription
1Navigation menu - Breadcrumb navigation menu.
2Frame Health - Provides the overall frame health status.
Statuses include:
•OK
•Warning
•Critical
3Information - Provides detailed frame information including real-time
power and temperature readings.
4Network - Provides the network address for a connected frame.
5Frame Link Module Ports - Displays the frame link module MGMT
and LINK port information for the Active and Standby frame link
modules.
6FLM Certificates - Displays the frame link module public certificates
and keys.
Table Continued
Configuring HPE Synergy75
Page 76
ItemDescription
7Frame rear view - Displays the components installed in the rear of
the frame and the health status of each component. Each component
can be clicked to view individual component health and information
screens.
8Frame front view - Displays the components installed in the front of
the frame and the health status of each component. Each component
can be clicked to view individual component health and information
screens.
9Actions menu - provides access to management and diagnostic
actions.
10Help screen - Provides a description of the HPE Synergy Console
icons and access to the frame link module end-user license
agreement.
Verifying installation using HPE OneView
Procedure
1. From the Synergy Console, click Connect to start HPE OneView.
2. To connect with install technician user privileges, click Hardware Setup.
To connect as Administrator, select the Administrator access check box.
3. Review the hardware inventory.
a.
NOTE: A spinning icon at the top of the inventory section indicates when HPE OneView is bringing
the enclosures and the devices within them under management. Devices might not be listed until
the discovery process is complete.
76 Verifying installation using HPE OneView
Page 77
Wait for HPE OneView to complete the add operation.
b. Confirm that the inventory includes all installed components.
c. For any hardware not discovered by HPE OneView, look for problems with frame link module
cabling, hardware not fully inserted, or other hardware issues.
4. Review and correct any issues listed in the Hardware Setup Checklist.
a. To troubleshoot all issues, follow corrective actions in HPE OneView.
b. Return to the Hardware Setup screen and check for additional issues until the Checklist indicates
Setup complete.
For more information about using HPE OneView, see the online help by clicking the question mark on
the top bar of the Synergy console.
5. (Optional) Select Edit networking from the Hardware Setup screen.
Edit the HPE OneView networking settings and click OK. The Maintenance IP address fields are
required unless you have disabled service console access.
6. To add a remote enclosure, select Actions > Add remote enclosures from the Hardware Setup
screen.
Enter the IPv6 address of a frame link module that is connected to a frame in the remote frame link
topology. The remote frame link topology must be in the same subnet as the primary frame link
topology.
7. Unmanaged interconnect modules require console access for initial setup. Click the Actions menu on
the top bar of the Synergy console and select the module from the Serial Consoles > Interconnects
menu. Press the Enter key to begin the serial console session with that interconnect module.
Configure the interconnect module using the instructions provided with the module. To close the
session, click the X in the top right corner.
NOTE: To access the serial console for an interconnect module, connect to the Synergy console
through ports in the same frame as the module. For more information, see the procedures for
connecting to the Synergy console.
8. Log out from the HPE OneView Hardware Setup session.
To close the session, click the X in the top right corner of the Synergy console.
After hardware setup is complete, the system is ready to be configured for a production environment.
An HPE OneView administrator can perform configuration tasks with an account that provides
additional user privileges.
For more information about HPE OneView administration, see the HPE OneView online help or the
HPE OneView User Guide for Synergy.
For operating system deployment options on HPE Synergy, see the HPE Synergy 12000 Frame Setupand Installation Guide.
Configure HPE Synergy Image Streamer
HPE Synergy Image Streamer can be used to deploy OS build artifacts to the Synergy compute modules.
However, it must be installed and configured within HPE OneView.
Configure HPE Synergy Image Streamer77
Page 78
Procedure
1. Create a management network that is consistent with the HPE OneView management network.
2. Add an IPv4 subnet and address range.
Define the range of IPv4 addresses and subnets to set aside for each Image Streamer appliance in
the frame link topology, plus the number of operating system servers expected to be deployed.
3. Add an OS deployment server for use in HPE OneView to deploy operating systems to managed
servers.
4. Create a deployment network to enable operating system deployment to servers using Image
Streamer.
5. Create one or more logical interconnect groups to define the connections between Image Streamer
appliances and the servers they will support.
6. Create an enclosure group that includes the Image Streamer configuration.
7. Create a logical enclosure to define the set of frames to which to apply the Image Streamer enclosure
group.
For more information about configuring HPE Image Streamer, see the HPE OneView online help or the
HPE OneView User Guide on the Hewlett Packard Enterprise website (http://www.hpe.com/info/
synergy-docs).
Configuring HPE OneView to deploy OS build artifacts to compute modules
Once you add an Image Streamer OS deployment server in HPE OneView, you can launch the Image
Streamer graphical user interface from the HPE OneView OS Deployment Servers screen.
Procedure
1. Upload artifacts from a bundle or create new artifacts.
From the Image Streamer interface, the software administrator can upload artifacts from a bundle for
use in HPE OneView or use the Image Streamer interface to create golden images and other OS build
artifacts.
2. Create or configure a server profile.
Create and apply a server profile which includes an OS deployment selection and values for the
server-specific settings for the selected OS deployment.
3. Verify operating system deployment.
Review server profile screen details to view the operating system volume that has been created as a
result of deployment.
4. Power on the compute module.
Power on server to boot from deployed operating system.
For more information about using Image Streamer to create and deploy OS build artifacts, see the Image
Streamer online help or the HPE Image Streamer User Guide on the Hewlett Packard Enterprise website
(http://www.hpe.com/info/synergy-docs).
78 Configuring HPE OneView to deploy OS build artifacts to compute modules
Page 79
Troubleshooting
Error screens when connecting to the Synergy console
The following are some basic errors screens that may be encountered when connecting to the Synergy
console.
Synergy Composer not responding
If the frame Composers are detected but not responding after 20 minutes, the following Attention screen
appears, and prompts a Reset.
Select Reset. HPE OneView resets and attempts again to boot the frame Composers.
Troubleshooting79
Page 80
Frame not claimed by a Synergy Composer
When the frame is not claimed by a Synergy Composer, the following Attention screen appears.
To resolve, connect to the front panel display of a frame that contains a Synergy Composer.
80 Frame not claimed by a Synergy Composer
Page 81
Synergy console cannot connect to HPE OneView
If the Synergy console cannot connect to HPE OneView, the following Attention screen appears.
Synergy console cannot connect to HPE OneView81
Page 82
If you are unable to connect to HPE OneView, perform the following troubleshooting solutions.
Procedure
1. Connect to the Synergy console through a different frame.
2. Reconnect to HPE OneView.
3. Verify there are no more than three live HPE OneView sessions within the management network. Any
initiated sessions after three will not be able to connect to HPE OneView.
Synergy console also has icons available for further navigation. For more information, see "Synergy
console icons."
Synergy console icons
The icons in the top right help to navigate.
•Question Mark icon - Select this icon to access the basic Synergy console help screen.
•i icon - Select this icon to access the Information screen. The local frame information, including
firmware version and discovered hardware components within the frame are displayed.
82 Synergy console icons
Page 83
•Screen icon - Select this icon to access the hardware components discovered by the Synergy
console, including Appliances, Interconnects, and Devices. Empty bays are represented by the grayed
out "--" symbol, and components that are discovered but not managed by a serial port are grayed out
and disabled.
Troubleshooting83
Page 84
•Serial console - To access the serial console:
1. Select one of the hardware components from the Screen icon to access the serial console for that
component.
84Troubleshooting
Page 85
2. Press Enter or another key on the keyboard to activate the console, if needed. Once activated, the
console will begin to display data for the hardware component.
•Keyboard shortcuts - These include:
Keyboard shortcutAction
F10Show or hide the top caption bar
Ctrl +Zoom in
Ctrl -Zoom out
Ctrl =Zoom default settings
Ctrl InsertCopy selected text
Shift InsertPaste selected text
Issues during installation
During the hardware setup, any installation errors are returned on the final checklist. See the following
image as an example:
—Indicates a critical error that must be corrected.
•
•—Indicates a warning that can be corrected, but is not mandatory. For hardware issues, this
warning could mean that redundancy has been lost and additional failures would cause a loss of
service.
Issues during installation85
Page 86
To correct the errors that appear, select the hyperlink to the right of the suggested corrective action, and
then follow any additional steps suggested on the screen.
HPE Synergy console
The HPE Synergy console is available from a direct connection to the frame if the HPE OneView user
interface cannot be accessed. The functions available in the console might require specific user
credentials.
The HPE Synergy console provides users the ability to troubleshoot issues within the frame and complete
regular maintenance on the installed appliances. From the HPE Synergy console, you can:
•View appliance details
•Restart or shutdown an appliance
•Activate an offline appliance.
•Create a support dump file.
•Reset the appliance password.
•Factory reset the appliance.
•Launch service console.
For more information about the HPE Synergy console, see the HPE Synergy 12000 Frame Maintenance
and Service Guide or the HPE OneView User Guide on the Hewlett Packard Enterprise website.
86 HPE Synergy console
Page 87
Accessing the HPE OneView maintenance console from the frame link
module
Procedure
1. Connect locally to the HPE Synergy console.
2. Select the Screen icon at the top right of the page.
3. Select an HPE Synergy Composer appliance from the Appliances menu.
A blank text window appears.
4. Press Enter.
5. At the login prompt, log in using the username: maintenance.
The HPE OneView maintenance console opens.
For additional instructions on using the HPE OneView maintenance console, see the HPE OneView User
Guide for HPE Synergy on the Hewlett Packard Enterprise website.
Connecting to the HPE OneView maintenance console using SSH
NOTE: Hewlett Packard Enterprise recommends the use of these tools for accessing the HPE OneView
maintenance console through an SSH connection:
•PuTTY
•MTPuTTY
•vSphere/vCenter Console (HPE BladeSystem c7000)
•Hyper-V console (HPE BladeSystem c7000)
Access the appliance console using this procedure:
Procedure
1. Open one of the recommended tools on your local computer.
2. Access the appliance by specifying its fully qualified domain name or its IP address.
3. Enter the user name maintenance at the login prompt.
4. Log in to the HPE OneView maintenance console.
5. Provide the local administrator credentials when prompted.
Creating a support dump file
This procedure describes how to use the HPE Synergy maintenance console to create a support dump
file from the local appliance (the appliance on which the HPE Synergy maintenance console runs) and
store it on a USB drive.
If the local appliance is the active appliance in an appliance cluster and if the standby appliance is
reachable, the support dump contains the data for both cluster members. Otherwise, a support dump is
created with data for the local appliance only.
Accessing the HPE OneView maintenance console from the frame link module87
Page 88
The support dump file is encrypted by default.
CAUTION: Creating the support dump file overwrites any existing backup file on the appliance. If
possible, refrain from creating a support dump if you have not copied the backup file to an external
location for safekeeping.
•Use a USB 2.0 or 3.0 device drive, formatted as an NTFS or FAT32 file system and with only one
partition. If necessary, use a computer to format the USB drive.
•The USB drive must have enough free space (typically 1 GB to 4 GB) to store the support dump file.
Creating a support dump file from the HPE Synergy maintenance console
Procedure
1. Ensure that the USB drive is installed in the USB port of the local appliance.
IMPORTANT: Do not remove the USB drive until the operation is complete and the Synergy
maintenance console advises that it is safe to remove the drive.
2. Use the appliance console to access the HPE Synergy maintenance console main menu.
3. Select Support dump.
A new set of commands appears.
4. Do one of the following:
•Select Create support dump to create a support dump and copy it to the USB drive.
•Select Download existing support dump to copy a support dump from the appliance to the USB
drive.
5. Wait until the support dump file is copied. There is a message on the screen stating that the support
dump was successfully completed and that it is safe to remove the USB drive.
Resetting to factory settings
In the event that you need to reset settings to their original factory status, the following options are
available:
•Resetting the appliance to the original factory settings on page 88
•Performing a frame link module factory reset on page 90
Resetting the appliance to the original factory settings
A factory reset restores the appliance to the original factory settings. It does not change the installed
firmware version.
You have the option of preserving or erasing the appliance network settings. A factory reset with
preserved network settings is necessary for recovering an HPE Synergy Composer from an
88 Resetting to factory settings
Page 89
unrecoverable error state. This option clears most faults so that you can restore the appliance from a
backup file.
You might need to reset the appliance either to decommission it (so that you can migrate the hardware) or
to return the appliance to a known state for reuse (for example, to restore the appliance from a backup
file).
CAUTION: This action erases appliance data including logs. REST API calls and GUI operations
are not allowed during the reset action.
In an appliance cluster, both the active appliance and the standby appliance are reset.
•When resetting or reimaging a Composer to a factory-fresh state, you must also reset all the frames
managed by that Composer to their factory-fresh state. However, if you intend to restore the
Composer settings from a backup after it is reset or reimaged, you do not need to reset all the frames.
IMPORTANT: To reset the whole system to a factory-fresh state, you must also perform a factory
reset on all the frames in the domain.
If you intend to restore the system from a backup file, you do not need to perform a factory reset
of all the frames. Restoring the system from the backup file restores the frames to management.
•Ensure that all tasks have been completed or stopped, and that all other users are logged off.
Procedure
1. If you are decommissioning the appliance and its managed environment, remove all hardware from
HPE OneView management, for example:
•Delete or un-assign all server profiles.
•Delete all logical enclosures.
•Delete any storage volumes allocated within HPE OneView.
•Reset managed devices (configured through IP address pools) to default IP addressing
2. From the main menu, select Settings ,and then click Appliance.
3. Select Actions > Factory Reset.
4. Select the appropriate option:
•Reset to factory defaults while preserving appliance network settings—Use this option to erase the
appliance data without losing network connectivity, for example, for rebuilding the appliance.
•Full appliance factory reset to defaults—Use this option to prepare a system when returning or
discarding appliance hardware, or when completely reusing a new appliance with new
communication settings.
IMPORTANT: This option can cause you to lose your network connection to the appliance.
Therefore, you must access the appliance using its IPv6 link local address.
Troubleshooting89
Page 90
This action displays a progress bar while it is running. Logins are disabled automatically. When the
appliance reset is completed after several minutes, you can log in and set up your appliance as you
did for the first time.
Performing a frame link module factory reset
NOTE: This procedure only factory resets the frame link modules installed in the frame. It does not factory
reset any other components installed in the frame.
NOTE: The frame link module can be factory reset by pressing the front panel reset button until the front
panel UID flashes or by using the HPE Synergy Console Actions menu. Hewlett Packard Enterprise
recommends using the HPE Synergy Console to perform a factory reset.
Documentation and troubleshooting resources
for HPE Synergy
HPE Synergy documentation
The Hewlett Packard Enterprise Information Library (
repository. It includes installation instructions, user guides, maintenance and service guides, best
practices, and links to additional resources. Use this website to obtain the latest documentation, including:
•Learning about HPE Synergy technology
•Installing and cabling HPE Synergy
•Updating the HPE Synergy components
•Using and managing HPE Synergy
•Troubleshooting HPE Synergy
www.hpe.com/info/synergy-docs) is a task-based
HPE Synergy Configuration and Compatibility Guide
The HPE Synergy Configuration and Compatibility Guide is in the Hewlett Packard Enterprise Information
Library (www.hpe.com/info/synergy-docs). It provides an overview of HPE Synergy management and
fabric architecture, detailed hardware component identification and configuration, and cabling examples.
HPE Synergy Frame Link Module User Guide
The HPE Synergy Frame Link Module User Guide is in the Hewlett Packard Enterprise Information
Library (www.hpe.com/info/synergy-docs). It outlines frame link module management, configuration,
and security.
HPE OneView User Guide for HPE Synergy
The HPE OneView User Guide for HPE Synergy is in the Hewlett Packard Enterprise Information Library
(www.hpe.com/info/synergy-docs). It describes resource features, planning tasks, configuration quick
start tasks, navigational tools for the graphical user interface, and more support and reference information
for HPE OneView.
HPE OneView Global Dashboard
The HPE OneView Global Dashboard provides a unified view of health, alerting, and key resources
managed by HPE OneView across multiple platforms and data center sites. The HPE OneView Global
Dashboard User Guide is in the Hewlett Packard Enterprise Information Library (www.hpe.com/info/
synergy-docs). It provides instructions for installing, configuring, navigating, and troubleshooting the
HPE OneView Global Dashboard.
HPE Synergy Image Streamer User Guide
The HPE Synergy Image Streamer User Guide is in the Hewlett Packard Enterprise Information Library
(www.hpe.com/info/synergy-docs). It describes the OS deployment process using Image Streamer,
features of Image Streamer, and purpose and life cycle of Image Streamer artifacts. It also includes
authentication, authorization, and troubleshooting information for Image Streamer.
Documentation and troubleshooting resources for HPE Synergy91
Page 92
HPE Synergy Image Streamer GitHub
The HPE Synergy Image Streamer GitHub repository (github.com/HewlettPackard) contains sample
artifacts and documentation on how to use the sample artifacts. It also contains technical white papers
explaining deployment steps that can be performed using Image Streamer.
HPE Synergy Software Overview Guide
The HPE Synergy Software Overview Guide is in the Hewlett Packard Enterprise Information Library
(www.hpe.com/info/synergy-docs). It provides detailed references and overviews of the various
software and configuration utilities to support HPE Synergy. The guide is task-based and covers the
documentation and resources for all supported software and configuration utilities available for:
•HPE Synergy setup and configuration
•OS deployment
•Firmware updates
•Troubleshooting
•Remote support
Best Practices for HPE Synergy Firmware and Driver Updates
The Best Practices for HPE Synergy Firmware and Driver Updates is in the Hewlett Packard Enterprise
Information Library (www.hpe.com/info/synergy-docs). It provides information on how to update the
firmware and recommended best practices to update firmware and drivers through HPE Synergy
Composer, which is powered by HPE OneView.
HPE OneView Support Matrix for HPE Synergy
The HPE OneView Support Matrix for HPE Synergy is in the Hewlett Packard Enterprise Information
Library (www.hpe.com/info/synergy-docs). It maintains the latest software and firmware requirements,
supported hardware, and configuration maximums for HPE OneView.
HPE Synergy Image Streamer Support Matrix
The HPE Synergy Image Streamer Support Matrix is in the Hewlett Packard Enterprise Information
Library (www.hpe.com/info/synergy-docs). It maintains the latest software and firmware requirements,
supported hardware, and configuration maximums for HPE Synergy Image Streamer.
HPE Synergy Glossary
The HPE Synergy Glossary, in the Hewlett Packard Enterprise Information Library (www.hpe.com/info/
synergy-docs), defines common terminology associated with HPE Synergy.
HPE Synergy troubleshooting resources
HPE Synergy troubleshooting resources are available within HPE OneView and in the Hewlett Packard
Enterprise Information Library (www.hpe.com/info/synergy-docs).
Troubleshooting within HPE OneView
HPE OneView graphical user interface includes alert notifications and options for troubleshooting within
HPE OneView. The UI provides multiple views of HPE Synergy components, including colored icons to
indicate resource status and potential problem resolution in messages.
92 HPE Synergy Image Streamer GitHub
Page 93
You can also use the Enclosure view and Map view to quickly see the status of all discovered HPE
Synergy hardware.
HPE Synergy Troubleshooting Guide
The HPE Synergy Troubleshooting Guide is in the Hewlett Packard Enterprise Information Library
(www.hpe.com/info/synergy-docs). It provides information for resolving common problems and courses
of action for fault isolation and identification, issue resolution, and maintenance for both HPE Synergy
hardware and software components.
Error Message Guide for HPE ProLiant Gen10 servers and HPE Synergy
The Error Message Guide for HPE ProLiant Gen10 servers and HPE Synergy is in the Hewlett Packard
Enterprise Information Library (www.hpe.com/info/synergy-docs). It provides information for resolving
common problems associated with specific error messages received for both HPE Synergy hardware and
software components.
HPE OneView Help and HPE OneView API Reference
The HPE OneView Help and the HPE OneView API Reference are readily accessible, embedded online
help available within the HPE OneView user interface. These help files include “Learn more” links to
common issues, as well as procedures and examples to troubleshoot issues within HPE Synergy.
The help files are also available in the Hewlett Packard Enterprise Information Library (www.hpe.com/
info/synergy-docs).
HPE Synergy QuickSpecs
HPE Synergy has system specifications as well as individual product and component specifications. For
complete specification information, see the HPE Synergy and individual HPE Synergy product
QuickSpecs on the Hewlett Packard Enterprise website (www.hpe.com/info/qs).
HPE Synergy has system specifications as well as individual product and component specifications. For
complete specification information, see the HPE Synergy and individual HPE Synergy product
QuickSpecs on the Hewlett Packard Enterprise website (
www.hpe.com/info/qs).
96 Specifications
Page 97
Electrostatic discharge
Be aware of the precautions you must follow when setting up the system or handling components. A
discharge of static electricity from a finger or other conductor may damage system boards or other staticsensitive devices. This type of damage may reduce the life expectancy of the system or component.
To prevent electrostatic damage:
•Avoid hand contact by transporting and storing products in static-safe containers.
•Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
•Place parts on a grounded surface before removing them from their containers.
•Avoid touching pins, leads, or circuitry.
•Always be properly grounded when touching a static-sensitive component or assembly. Use one or
more of the following methods when handling or installing electrostatic-sensitive parts:
◦Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist
straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords.
To provide proper ground, wear the strap snug against the skin.
◦Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet
when standing on conductive floors or dissipating floor mats.
◦Use conductive field service tools.
◦Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an authorized reseller
install the part.
For more information on static electricity or assistance with product installation, contact an authorized
reseller.
Electrostatic discharge97
Page 98
Support and other resources
Accessing Hewlett Packard Enterprise Support
•For live assistance, go to the Contact Hewlett Packard Enterprise Worldwide website:
http://www.hpe.com/assistance
•To access documentation and support services, go to the Hewlett Packard Enterprise Support Center
website:
http://www.hpe.com/support/hpesc
Information to collect
•Technical support registration number (if applicable)
•Product name, model or version, and serial number
•Operating system name and version
•Firmware version
•Error messages
•Product-specific reports and logs
•Add-on products or components
•Third-party products or components
Accessing updates
•Some software products provide a mechanism for accessing software updates through the product
interface. Review your product documentation to identify the recommended software update method.
•To download product updates:
Hewlett Packard Enterprise Support Center
www.hpe.com/support/hpesc
Hewlett Packard Enterprise Support Center: Software downloads
www.hpe.com/support/downloads
Software Depot
www.hpe.com/support/softwaredepot
•To subscribe to eNewsletters and alerts:
www.hpe.com/support/e-updates
•To view and update your entitlements, and to link your contracts and warranties with your profile, go to
the Hewlett Packard Enterprise Support Center More Information on Access to Support Materials
page:
98 Support and other resources
Page 99
www.hpe.com/support/AccessToSupportMaterials
IMPORTANT: Access to some updates might require product entitlement when accessed through
the Hewlett Packard Enterprise Support Center. You must have an HPE Passport set up with
relevant entitlements.
Customer self repair
Hewlett Packard Enterprise customer self repair (CSR) programs allow you to repair your product. If a
CSR part needs to be replaced, it will be shipped directly to you so that you can install it at your
convenience. Some parts do not qualify for CSR. Your Hewlett Packard Enterprise authorized service
provider will determine whether a repair can be accomplished by CSR.
For more information about CSR, contact your local service provider or go to the CSR website:
http://www.hpe.com/support/selfrepair
Remote support
Remote support is available with supported devices as part of your warranty or contractual support
agreement. It provides intelligent event diagnosis, and automatic, secure submission of hardware event
notifications to Hewlett Packard Enterprise, which will initiate a fast and accurate resolution based on your
product's service level. Hewlett Packard Enterprise strongly recommends that you register your device for
remote support.
If your product includes additional remote support details, use search to locate that information.
Remote support and Proactive Care information
HPE Get Connected
www.hpe.com/services/getconnected
HPE Proactive Care services
www.hpe.com/services/proactivecare
HPE Proactive Care service: Supported products list
To view the warranty for your product or to view the Safety and Compliance Information for Server,
Storage, Power, Networking, and Rack Products reference document, go to the Enterprise Safety and
To view the regulatory information for your product, view the Safety and Compliance Information for
Server, Storage, Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise
Hewlett Packard Enterprise is committed to providing our customers with information about the chemical
substances in our products as needed to comply with legal requirements such as REACH (Regulation EC
No 1907/2006 of the European Parliament and the Council). A chemical information report for this product
can be found at:
www.hpe.com/info/reach
For Hewlett Packard Enterprise product environmental and safety information and compliance data,
including RoHS and REACH, see:
www.hpe.com/info/ecodata
For Hewlett Packard Enterprise environmental information, including company programs, product
recycling, and energy efficiency, see:
www.hpe.com/info/environment
Documentation feedback
Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us
improve the documentation, send any errors, suggestions, or comments to Documentation Feedback
(docsfeedback@hpe.com). When submitting your feedback, include the document title, part number,
edition, and publication date located on the front cover of the document. For online help content, include
the product name, product version, help edition, and publication date located on the legal notices page.
100 Regulatory information
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.