HP StorageWorks Modular Smart Array 500 Overview

QuickSpecs

Overview

HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
1. Display
2. Display Buttons
3. Display Indicators
4. Modular Smart Array Controller
1. Power Supply/Blower Indicators
2. Power Supply/Blower Assemblies
3. SCSI Port A
5. Power Switch
6. Status Indicators
7. Redundant Controller Slot Blank
4. SCSI Port B
5. SCSI I/O Indicators
6. SCSI I/O with Integrated Environmental Monitoring Unit (EMU)
DA - 11050 Canada — Version 13 — July 19, 2004
Page 1
QuickSpecs
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
Overview
What's New
What's New
What's NewWhat's New
New name, formerly named Smart Array Cluster Storage MSA500 Starter Kit with 2 host adapters included MSA500 High Availability Kit includes everything needed to make MSA500 system fully redundant at a new low price Microsoft® Windows® Server 2003 Support UnitedLinux 1.0 Support Novell NetWare 6.5 Support Storage sharing with up to 4 direct attached servers
At A Glance
At A Glance
At A GlanceAt A Glance
Two node high availability clustering Shared storage for up to 4 ProLiant servers Redundant capable Smart Array Controllers with LCD screen to show system status messaging. Total storage capacity of 2TB, by using 14 HP Universal U320 Hard Disks of 146.8 GB each Multipath connectivity option with load balancing Redundant Power Supplies and Fans standard Fully convertible to HP StorageWorks Modular Smart Array 1000 RAID 0, 1, 1+0, 5 and ADG standard Supports up to 512 MB of Battery Backed Cache (2x256 MB). Pre-Failure Warranty that covers disk drives
DA - 11050 Canada — Version 13 — July 19, 2004
Page 2
QuickSpecs
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500

Standard Features

Modular Smart Array Family
Modular Smart Array Family
Modular Smart Array FamilyModular Smart Array Family The HP StorageWorks Modular Smart Array family delivers easy, affordable storage technology to meet today's demanding and growing IT needs. These
storage solutions offer the best price/performance features for direct attach environments, small clusters, workgroup sharing and entry-level SAN environments. Each solution is designed to be easy to deploy, secure, reduce management costs, while driving rapid return on investment.
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500Modular Smart Array 500 The HP StorageWorks Modular Smart Array 500 (MSA 500), formerly named Modular Smart Array 500, is an Ultra3 SCSI (supporting Ultra320 hard drives)
storage system, supporting up to 2TB of data capacity, designed specifically for 2-node clustering and multiple node (up to 4 servers) shared storage. Designed to reduce the complexity and expense of clustering and storage sharing, the Modular Smart Array 500 is built upon Smart Array and ProLiant technologies to provide advanced data protection features yet is simple to deploy, configure and manage. Ideal for entry level clustering and shared storage, the Modular Smart Array 500 is familiar SCSI technology, making it a simple and powerful storage platform. As the customer's clustering and storage requirements grow, the Modular Smart Array 500 may be converted to a SAN array by replacing the controller(s) and I/O module and installing a MSA 1000 FC I/O module, or MSA 1000 FC switch, providing the customer with extended hardware investment protection into the future. The Modular Smart Array 500 combines the array controller shelf and the drive shelf, which holds up to fourteen 1 HP Universal Disk drives in a single 4U rack mount cabinet, that's over 2 terabytes of storage.
Key Features
Key Features
Key FeaturesKey Features
High performance Modular Smart Array controller(s) with LCD for system status messages. Standard 128-MB Battery Backed Cache, upgradeable to 512 MB maximum. Optional redundant Modular Smart Array controller. 4U rack mount chassis combining both the controller and disk shelf. Ultra3 SCSI back panel and drive interconnect. SSP (Selective Storage Presentation) for storage sharing with multiple servers. 2TB capacities with support of 14 Ultra320, Ultra3 and Ultra2 Universal 1 Drives. Redundant power supplies and fans are standard. RAID levels 0, 1, 1 0, 5, RAID ADG. Optional 4-Port Shared Storage Module with Smart Array Multipath software with load balancing. Optional ProLiant Essentials Recovery Server Option Convertible to MSA 1000 for capacity expansion and increased host connections Remote configuration and monitoring via ACU & Insight Manager 7. Qualified and certified for Windows, Linux and NetWare 2-node clustering Support for select ProLiant servers (see Server Compatibility on page 14 or
http://www.hp.com/go/msa
for latest compatibility).
DA - 11050 Canada — Version 13 — July 19, 2004
Page 3
QuickSpecs

Product Highlights

Modular Smart Array 500 Highlights
Modular Smart Array 500 Highlights
Modular Smart Array 500 HighlightsModular Smart Array 500 Highlights
High Levels of
High Levels of
High Levels ofHigh Levels of Performance, Data
Performance, Data
Performance, DataPerformance, Data Protection and
Protection and
Protection andProtection and Functionality
Functionality
FunctionalityFunctionality
High Availability
High Availability
High AvailabilityHigh Availability Novell NetWare environments. High Performance
High Performance
High PerformanceHigh Performance Plus embedded controller in the ProLiant servers. Storage Capacity
Storage Capacity
Storage CapacityStorage Capacity maximum of 2TB of shared storage capacity using HP 146.8 Ultra320 SCSI Universal 1" hard drives. Data Protection
Data Protection
Data ProtectionData Protection controllers (optional), redundant fans and power supplies (standard); multiple I/O path capability with Smart Array Multipath software option, support for Hot Pluggable AIT and DAT tape drives in the storage enclosure, transportable battery-backed cache and RAID ADG (standard). Storage Manageability
Storage Manageability
Storage ManageabilityStorage Manageability such as Smart Array Configuration Utility and Insight Manager. Online Management Features: Online Capacity Expansion (single path only), Online RAID Level Migration, Online Stripe Size Migration, Online Spares (Global), User Selectable Read/Write cache, User Selectable Expand and Rebuild Priority. Choice of Computing Platform
Choice of Computing Platform
Choice of Computing PlatformChoice of Computing Platform Advanced Data Guarding (RAID ADG) Fault Tolerance
Advanced Data Guarding (RAID ADG) Fault Tolerance
Advanced Data Guarding (RAID ADG) Fault ToleranceAdvanced Data Guarding (RAID ADG) Fault Tolerance tolerance. It allocates two sets of parity data across drives and allows simultaneous write operations. This level of fault tolerance can withstand two simultaneous drive failures without downtime or data loss.
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
– supports a broad range of clustering options for Microsoft Windows Server, Linux Server and
– Data transmission rate of 14,000 IOPS – 2 Node cluster configuration using Smart Array 5i
– The Modular Smart Array 500 cabinet supports up to fourteen 1" Universal hard drives, for a
– Modular Smart Array 500 is designed for a high level of data protection. It includes redundant
– The Smart Array Controllers feature familiar configuration and management tools
– The Modular Smart Array 500 is designed and qualified for ProLiant servers.
– This is the highest level of RAID fault
DtS (DAS to SAN)
DtS (DAS to SAN)
DtS (DAS to SAN)DtS (DAS to SAN) Technology
Technology
TechnologyTechnology
Low Total Cost of
Low Total Cost of
Low Total Cost ofLow Total Cost of Ownership
Ownership
OwnershipOwnership
The Smart Array architecture provides a quick and easy way to migrate from the Modular Smart Array 500 to the Modular Storage Array 1000 (MSA 1000). In order to convert the Modular Smart Array 500 to a SAN, simply remove the Modular Smart Array Controller(s) and replace them with StorageWorks MSA 1000 Controller(s) and add FC I/O board or FC Switch (please refer to MSA 1000 Quickspecs for additional SAN requirements information). This is referred to as DtS technology (DAS-to-SAN technology). In addition to convertibility to the SAN, the Modular Smart Array 500 allows the seamless migration of stored data in ProLiant servers protected by Smart Array PCI controllers to a Modular Smart Array 500 system. Data that is currently stored on 1" Universal disk drives using HP Smart Array controllers, as well as data on an RA4100 can easily be migrated to the Modular Smart Array 500. Simply remove the drives from the older systems and insert them into the Modular Smart Array
500. Existing data and configuration will remain intact. In addition, the RAID set and data will be preserved allowing migration to be completed in minutes, not hours.
The modular, scalable design of the Modular Smart Array 500 provides an extremely flexible platform. You can buy what you need today and purchase additional capacity and performance as your data storage needs grow, instead of making a large up-front investment. Additional drives, controllers, and cache can be easily added as your needs dictate.
Storage Consolidation
Storage Consolidation
Storage ConsolidationStorage Consolidation internal storage to the Modular Smart Array 500. Universal Hard Drive
Universal Hard Drive
Universal Hard DriveUniversal Hard Drive disk drives is protected and cost is minimized as you add new drives. Sharing of a common universal drive form factor between your server and storage can significantly reduce needs for hardware and spare inventory, and offer overall reduction in storage management and business costs. Pre-Failure Warranty
Pre-Failure Warranty
Pre-Failure WarrantyPre-Failure Warranty are supported by a Pre-Failure (replacement) Warranty. Pre-Failure Warranty allows for the replacement of designated drives in Modular Smart Array 500 before they actually fail when using Insight Manager on ProLiant servers.
NOTE:
NOTE:
Some operating systems may not support all of these features.
NOTE:NOTE:
Integrated Configuration and Management Tools
Integrated Configuration and Management Tools
Integrated Configuration and Management ToolsIntegrated Configuration and Management Tools integrated set of Smart Array management and utility software. These tools consistently lower the cost of ownership by reducing training and technical expertise necessary to install and maintain HP server storage.
– Improve storage utilization and lower storage management cost through moving
– Since the Modular Smart Array 500 supports Universal 1" SCSI drives, your investment in
– Drives installed in a Modular Smart Array 500 and monitored under Insight Manager
– The Modular Smart Array 500 utilizes the standard,
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500Modular Smart Array 500
The 4U array houses up to fourteen 1" Universal hot pluggable Ultra320, Ultra3 and/or Ultra2 drives. Each Modular Smart Array 500 includes the following standard components: Modular Smart Array 500 Controller, 2-port Ultra3 SCSI I/O Module, dual hot pluggable fans/power supplies, two power cables, two VHDCI SCSI cables and a crossover Ethernet cable.
DA - 11050 Canada — Version 13 — July 19, 2004
Page 4
QuickSpecs

Modular Smart Array 500 Components

Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500Modular Smart Array 500 Controller
Controller
ControllerController
4-Port Shared Storage
4-Port Shared Storage
4-Port Shared Storage4-Port Shared Storage Module with Smart Array
Module with Smart Array
Module with Smart ArrayModule with Smart Array Multipath
Multipath
MultipathMultipath
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500Modular Smart Array 500 Controller Management
Controller Management
Controller ManagementController Management Features
Features
FeaturesFeatures
The Modular Smart Array 500 Controller is an integrated RAID controller with an integrated LCD/LED status display and 128-MB read/write battery-backed cache (expandable to 512MB per controller). One Modular Smart Array 500 Controller is included with the Modular Smart Array 500; the redundant Modular Smart Array 500 Controller is an option..
The 4-Port Shared Storage Module is an option which may be used in one of two configurations:
Enhance cluster fault tolerance by adding multiple paths from the host servers to the shared storage. This provides an additional level of fault tolerance by adding redundancy to both the HBA in the host server as well as the SCSI cables connecting the host servers to the shared storage. Attach up to four independent servers to the Modular Smart Array 500. The storage capacity to each server is assigned with SSP (Shared Storage Presentation), a feature of the Array Configuration Utility. Using SSP and sharing storage among multiple host servers maximizes hard drive capacity utilization, and allows for additional hard drive capacity to be deployed (up to 14) with the volume extension and capacity expansion capabilities.
Online RAID Level Migration: allows for online post-configuration change to RAID level without destroying data or volume information. Online Capacity Expansion: allows for adding storage to an operational Modular Smart Array 500-reducing expensive server downtime (single path configuration only). Online Volume Extension: allows for the capacity growth of existing logical volumes (single path configuration only). Logical Drive Capacity Extension: allows the user to increase the size of existing logical drives online under Windows NT® and offline for other operating systems. Online Stripe Size Migration: Allows changing stripe sizing of a logical drive. User Selectable Read/Write Cache size, allocate cache sizes. User Selectable Expand and Rebuild Priority.
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
Controller Firmware
Controller Firmware
Controller FirmwareController Firmware Cloning
Cloning
CloningCloning
Multi Host Storage
Multi Host Storage
Multi Host StorageMulti Host Storage Sharing
Sharing
SharingSharing
RAID
RAID
RAIDRAID
Enhanced Controller Firmware Auto-Cloning allows customer choice of controller firmware version when adding redundant controller with different firmware version.
Selective Storage Presentation (SSP) support standard on both the base 2-port model of Modular Smart Array 500 as well as the optional 4-port Shared Storage Module. SSP allows the administrator to create volumes and assign access rights to a particular host server. This allows sharing the Modular Smart Array 500 with up to 4 host servers maximizing storage capacity utilization. SSP also allows online capacity expansion as well as online volume extension in DAS configurations.
Several fault tolerant configurations keep data available and servers running while drives are being replaced, including:
Advanced Data Guarding (RAID ADG): Allocates the equivalence of 2 parity drives across multiple drives and allows simultaneous write operations. Distributed Data Guarding (RAID 5): Allocates parity data across multiple drives and allows simultaneous write operations. Drive Mirroring (RAID 1 and 1+0 Striped Mirroring): Allocates half of the drive array to data and the other half to mirrored data, providing two copies of every file.
DA - 11050 Canada — Version 13 — July 19, 2004
Page 5
QuickSpecs
Modular Smart Array 500 Components
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500Modular Smart Array 500 Controller
Controller
ControllerController
SCSI I/O Module
SCSI I/O Module
SCSI I/O ModuleSCSI I/O Module
Controller Cache Upgrade
Controller Cache Upgrade
Controller Cache UpgradeController Cache Upgrade
Fault Recovery
Fault Recovery
Fault RecoveryFault Recovery
The I/O module on the Modular Smart Array includes an integrated Environmental Monitoring Unit which performs several functions including monitoring the enclosure functions, providing I/O connectors and signaling enclosure status. Modular Smart Array 500 ships standard with a 2-Port I/O Module. The 4-Port Shared Storage Module with Smart Array Multipath is available as an option. The 4-Port Shared Storage Module may be deployed as follows:
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
Cache on the Modular Smart Array 500 Controller may be upgraded to a maximum of 512 MB.
NOTE:
NOTE:
NOTE: NOTE: configurations: 1 x 128 MB; 2 x 128 MB; 1 x 256 MB; 2 x 256 MB NOTE:
NOTE:
NOTE:NOTE: controllers must be identical.
The Modular Smart Array 500 Controller allows the following cache
When redundant controllers are installed, the cache configurations in both
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure. On-Line Spares: If a failure occurs, recovery begins with an on-line spare and data is reconstructed automatically. One on-line spare can be assigned per array and used across multiple arrays. It is also possible to assign different on-line spares across different arrays. Array Accelerator: Onboard, battery-backed cache memory protects data in the event of a power failure. In the unlikely event of a controller failure, the battery­backed cache will save critical user data for up to three days.
As the shared storage component with up to four servers in a DAS (Direct Attached Storage) configuration. Multiple I/O paths to a two node cluster or two direct attached servers.
DA - 11050 Canada — Version 13 — July 19, 2004
Page 6
QuickSpecs
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500

Software Components

The Modular Smart Array 500 utilizes a single, consistent set of utility software for storage and RAID management, setup, configuration and troubleshooting. This consistency reduces the cost of ownership by reducing the training and technical expertise necessary to install and maintain your HP server storage solution.
Configuration Utilities
Configuration Utilities
Configuration UtilitiesConfiguration Utilities
Management/Health
Management/Health
Management/HealthManagement/Health Utilities
Utilities
UtilitiesUtilities
Array Configuration
Array Configuration
Array ConfigurationArray Configuration Utility
Utility
(ACU)
UtilityUtility
Insight Manager 7
Insight Manager 7
Insight Manager 7Insight Manager 7
Array Configuration Utility (ACU) [On-line for Microsoft and Linux, Remote Web-Based & Off-line] Option ROM Configuration for Arrays (ORCA)
Insight Manager 7
Provides a graphical view of HP drive array configurations. Easy to use Wizards for configuration. Web Based ACU supports On-Line, Remote Web Based and Off-line configuration. Supports on-line configuration for Microsoft and Linux. Configures Selective Storage Presentation (SSP).
Powerful storage, server and server option management tool. Monitor storage from a remote central location. Browser based Insight Manager 7 provides full access from anywhere on the Intranet, eliminating the need for a dedicated Insight Manager console.
Supported Operating
Supported Operating
Supported OperatingSupported Operating Systems
Systems
SystemsSystems
Microsoft Windows Server 2003 Web Edition Microsoft Windows Server 2003 Standard Edition Microsoft Windows Server 2003 Enterprise Edition Microsoft Windows 2000 Server Microsoft Windows 2000 Advanced Server Microsoft Windows NT EE 4.0 Novell NetWare 5.1 Novell NetWare 6.0 Novell NetWare 6.5 Red Hat Linux 7.2, 7.3, 8.0 Red Hat Enterprise Linux 2.1 Red Hat Linux Advanced Server 2.1 UnitedLinux 1.0 (including SuSE Linux Enterprise Server 8) SuSE Linux Enterprise Server 7 (SLES 7) SCO OpenServer 5.0.5 and SCO OpenServer 5.0.6a
UnitedLinux = Conectiva Linux Enterprise Edition, SCO Linux 4.0, SuSE Linux Enterprise 8 and Turbolinux 8 all powered by UnitedLinux 1.0 Not all configurations are supported on all operating systems; please refer to compatibility matrix
http://www.hp.com/products/sharedstorage
for latest compatibility information.
DA - 11050 Canada — Version 13 — July 19, 2004
Page 7
QuickSpecs
Software Components
Supported Clustering
Supported Clustering
Supported ClusteringSupported Clustering Solutions
Solutions
SolutionsSolutions
Smart Array Multipath
Smart Array Multipath
Smart Array MultipathSmart Array Multipath Software
Software
SoftwareSoftware
(Optional)
Microsoft Cluster Service for Microsoft Windows Server 2003 Enterprise Edition Microsoft Cluster Service for Microsoft Windows 2000 Advanced Server Microsoft Cluster Service for Microsoft Windows NT EE 4.0 Novell Cluster Services on Novell NetWare 5.1 Novell Cluster Services on Novell NetWare 6.0 Novell Cluster Services on Novell NetWare 6.5 HP Serviceguard for Linux on Red Hat Linux 7.3, Red Hat Enterprise Linux 2.1, UnitedLinux 1.0 (including SuSE Linux Enterprise Server 8) SteelEye's LifeKeeper for Linux on Red Hat Linux 7.2, 7.3, 8.0, Red Hat Enterprise Linux 2.1, Red Hat Linux Advanced Server 2.1, UnitedLinux 1.0 (including SuSE Linux Enterprise Server 8), and SuSE Linux Enterprise Server 7 (SLES 7)
UnitedLinux = Conectiva Linux Enterprise Edition, SCO Linux 4.0, SuSE Linux Enterprise 8 and Turbolinux 8 all powered by UnitedLinux 1.0 Please refer to the HP High Availability Web site information.
Enhance cluster fault tolerance by adding dual paths from the host servers to the shared storage. This provides an additional level of fault tolerance by adding redundancy and performance to both the HBA in the host server as well as the SCSI cables connecting the host servers to the shared storage. Smart Array Multipath software delivers dual path functionality and supports failover capabilities for redundant host bus adapters (HBAs) in a server with redundant cabling to a Modular Smart Array 500. This fault-tolerance tool enhances availability of clustering and direct attached storage (DAS) solutions with up to two servers managing up to 2 TB of stored data. When an HBA failure occurs, the software moves the logical drives from the path of the failed HBA to the path of the redundant HBA located in the same server.
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
http://www.compaq.com/solutions/enterprise/highavailability
for latest
Warranty
Warranty
WarrantyWarranty
Increase availability by protecting against connectivity (HBA) and cable failures and accidental pull-outs. Ships with 4-Port Shared Storage Module Increase performance with Static LUN Balancing (Microsoft OS) enables the administrator to optimize I/O by assigning specific volumes to specific paths in the storage system. If one path fails the system moves volumes to the path for redundant HBA for I/O management. Increase performance with Static Load (read-only) Balancing (Linux OS) enables the HBAs to optimize I/O with dual paths to the same volumes in the storage system. If one HBA fails the system moves volumes to the path for the redundant HBA for I/O management. Supported Operating Systems: Windows Server 2003 Standard Edition, Windows Server 2003 Enterprise Edition; Windows 2000 Server; Windows 2000 Advanced Server; Red Hat Enterprise Linux 2.1, Red Hat Linux Advanced Server 2.1, UnitedLinux 1.0 (including SuSE Linux Enterprise Server 8), SLES 7.
Three-year labour, parts, on-site (3/3/3) Limited Warranty for Modular Smart Array 500.
DA - 11050 Canada — Version 13 — July 19, 2004
Page 8
QuickSpecs

HP Care Pack Service and Support

Software Product Services
Software Product Services
Software Product ServicesSoftware Product Services
Hardware Product Services
Hardware Product Services
Hardware Product ServicesHardware Product Services
Warranty Upgrade
Warranty Upgrade
Warranty UpgradeWarranty Upgrade Options
Options
OptionsOptions
Stand-alone telephone support Rights to new license version Media and documentation updates
Installation services On-site maintenance (includes warranty support) Response time upgrades during the warranty period Post-warranty coverage RAID setup and performance consulting via statement of work
For additional hardware installation and maintenance information, please refer to the URLs listed below:
English:
English: http://www.compaq.ca/English/service/cusserv/carepaq/carepaq.htm
English:English: French:
French: http://www.compaq.ca/Francais/service/ccs/carepaqf/carepaqf.htm
French:French:
Response – Upgrade on-site response from next business day to same day 4-hours Coverage – Extend hours of coverage from 5 days x 9 hours to 7 days x 24 hours Duration – Three-year, on-site Limited Warranty for Modular Smart Array 500, expandable to five years
HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage.
HP Care Pack is not available for less than the product's warranty duration. HP Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required. HP Care Pack services are prepaid.
For additional HP Care Pack (hardware & software) information, as well as orderable part numbers, please refer to the URL listed below:
English:
English: http://www.compaq.ca/English/productinfo/storage/storageworks.htm
English:English: French:
French: http://www.compaq.ca/Francais/Produits/stockage/Storageworksf.htm
French:French:
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
HP Care Pack Description
HP Care Pack Description
HP Care Pack DescriptionHP Care Pack Description
9x5, 4-Hour Response, On-Site Coverage, 3 years 24x7, 4-Hour Response, On-Site Coverage, 3 years Hardware Installation (on site)
FP-FC4HR-36
FP-FC724-36
FP-FCINS-IN
DA - 11050 Canada — Version 13 — July 19, 2004
Page 9
QuickSpecs

Configuration Information

Step 1: Order Required Items
Step 1: Order Required Items
Step 1: Order Required ItemsStep 1: Order Required Items
Models
Models
ModelsModels
Package Contents
Package Contents
Package ContentsPackage Contents
HP Modular Smart Array 500 Starter Kit (includes MSA 500 and 2 SA-532 Adapters) HP Modular Smart Array 500
4U Modular Smart Array 500 Modular Smart Array 500 Controller with 128 MB cache 2-port SCSI I/O Module Redundant Hot Pluggable Power Supply/blower assemblies Modular Smart Array 500 Rack Mounting Kit Modular Smart Array 500 Support Software or Smart Start Power cables (2) VHDCI SCSI cables 6' each (2) Crossover Ethernet cable for clustering User Manual Smart Array 532 Adapters (2) – Included in "MSA500 Starter Kit Only"
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
351504-B21 201724-B21
Step 2: Choose Modular Smart Array 500 System Options
Step 2: Choose Modular Smart Array 500 System Options
Step 2: Choose Modular Smart Array 500 System OptionsStep 2: Choose Modular Smart Array 500 System Options
Options
Options
OptionsOptions
Modular Smart Array 500 High Availability Kit (includes MSA500 controller, 4-port IO Module, Smart Array Multipath Software and 2 SA-532 Adapters)
Modular Smart Array 500 Controller 4-Port Shared Storage Module with Smart Array Multipath Software 128MB Battery Backed Cache Module 256MB Battery Backed Cache Module M-Series Rack Rail Kit Option
NOTE:
NOTE:
The Modular Smart Array 500 Controller allows the following cache configurations:
NOTE:NOTE: 1 x 128 MB; 2 x 128 MB; 1 x 256 MB; 2 x 256 MB. NOTE:
NOTE:
When redundant controllers are installed, the cache configurations in both controllers must be identical.
NOTE:NOTE:
351281-B21
218252-B21 292944-B21 153506-B21 254786-B21 313877-B21
DA - 11050 Canada — Version 13 — July 19, 2004
Page 10
QuickSpecs
Configuration Information
Step 3: Choose ProLiant Server(s)
Step 3: Choose ProLiant Server(s)
Step 3: Choose ProLiant Server(s)Step 3: Choose ProLiant Server(s)
Server Compatibility
Server Compatibility
Server CompatibilityServer Compatibility
ML330 G2 (Direct Attached and RSO configurations only) ML330 G3 (Direct Attached and RSO configurations only) ML350 G2 (Direct Attached and RSO configurations only) ML350 G3 (Clustering, Direct Attached and RSO configurations) ML370 G2 (Clustering, Direct Attached and RSO configurations) ML370 G3 (Clustering, Direct Attached and RSO configurations) DL360 G2 (Clustering, Direct Attached and RSO configurations) DL360 G3 (Clustering, Direct Attached and RSO configurations) DL380 G2 (Clustering, Direct Attached and RSO configurations) DL380 G3 (Clustering, Direct Attached and RSO configurations) DL560 (Clustering, Direct Attached and RSO configurations) DL580 (Clustering, Direct Attached and RSO configurations) DL580 G2 (Clustering, Direct Attached and RSO configurations) DL740 (Clustering and Direct Attached configurations) DL760 (Clustering and Direct Attached configurations) DL760 G2 (Clustering and Direct Attached configurations)
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
Step 4: Choose Host Connectivity (Skip If Purchased MSA500 Starter Kit)
Step 4: Choose Host Connectivity (Skip If Purchased MSA500 Starter Kit)
Step 4: Choose Host Connectivity (Skip If Purchased MSA500 Starter Kit)Step 4: Choose Host Connectivity (Skip If Purchased MSA500 Starter Kit)
Required for ML330 G2,
Required for ML330 G2,
Required for ML330 G2,Required for ML330 G2, ML350 G2, ML350 G3,
ML350 G2, ML350 G3,
ML350 G2, ML350 G3,ML350 G2, ML350 G3, ML370 G3, DL360 G2,
ML370 G3, DL360 G2,
ML370 G3, DL360 G2,ML370 G3, DL360 G2, DL360 G3, DL580, DL580
DL360 G3, DL580, DL580
DL360 G3, DL580, DL580DL360 G3, DL580, DL580 G2, DL760
G2, DL760
G2, DL760G2, DL760
Required for ML370 G2
Required for ML370 G2
Required for ML370 G2Required for ML370 G2
Optional for DL380 G2
Optional for DL380 G2
Optional for DL380 G2Optional for DL380 G2
Optional for DL380 G3
Optional for DL380 G3
Optional for DL380 G3Optional for DL380 G3
Smart Array 532 Controller Option Kit
Smart Array 532 Controller Smart Array 5i Controller Option Kit
NOTE:
NOTE:
Either one Smart Array 532 Controller or one Smart Array 5i or Smart 5i Plus Controller
NOTE:NOTE: Option Kit is required.
Smart Array 532 Controller Option Kit
NOTE:
NOTE:
The Smart Array 5i controller is included with the ProLiant DL380 G2.
NOTE:NOTE: adapter required unless implementing Smart Array Multipath technology
adapter required unless implementing Smart Array Multipath technology
adapter required unless implementing Smart Array Multipath technologyadapter required unless implementing Smart Array Multipath technology
Smart Array 532 Controller Option Kit
NOTE:
NOTE:
The Smart Array 5i Plus controller is included with the ProLiant DL380 G3. No additional
NOTE:NOTE: adapter required unless implementing Smart Array Multipath technology
No additional
No additional
No additionalNo additional
225338-B21
225338-B21 226593-B21
225338-B21
225338-B21
DA - 11050 Canada — Version 13 — July 19, 2004
Page 11
QuickSpecs
Configuration Information
Step 5: Choose Configuration Options
Step 5: Choose Configuration Options
Step 5: Choose Configuration OptionsStep 5: Choose Configuration Options
High Availability Software
High Availability Software
High Availability SoftwareHigh Availability Software
Step 6: Choose Hard Drives
Step 6: Choose Hard Drives
Step 6: Choose Hard DrivesStep 6: Choose Hard Drives
Pluggable, Universal
Pluggable, Universal
Pluggable, UniversalPluggable, Universal Hard Drives
Hard Drives
Hard DrivesHard Drives
ProLiant Essentials Recovery Server Option (RSO) HP Serviceguard for Linux ProLiant Cluster HP Serviceguard for Linux License ProLiant Cluster HA/L100 – LifeKeeper for Linux
NOTE:
NOTE:
Above options not required for Microsoft clustering, Novell clustering or non-clustered shared
NOTE:NOTE: storage configurations
36.4GB 10,000 rpm, U320 Universal Hard Drive, 1"
72.8GB 10,000 rpm, U320 Universal Hard Drive, 1"
146.8GB 10,000 rpm, U320 Universal Hard Drive, 1"
18.2GB 15,000 rpm, U320 Universal Hard Drive, 1"
36.4GB 15,000 rpm, U320 Universal Hard Drive, 1"
72.8GB 15,000 rpm, U320 Universal Hard Drive, 1"
NOTE:
NOTE:
NOTE: NOTE: require an optional U320 Smart Array Controller or U320 SCSI HBA to support U320 transfer rates.
NOTE:
NOTE:
NOTE:NOTE: located at
All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives
For complete compatibility information, refer to the HP SCSI Hard Drive Compatibility table
http://www.compaq.com/products//hdd/hotplug.html
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
280189-B21 305199-B21 307754-B21 303523-B21
286713-B22 286714-B22 286716-B22 286775-B22 286776-B22 286778-B22
Step 7: Choose Rack Option
Step 7: Choose Rack Option
Step 7: Choose Rack OptionStep 7: Choose Rack Option
HP Rack 10000 Series
HP Rack 10000 Series
HP Rack 10000 SeriesHP Rack 10000 Series (Graphite Metallic)
HP Rack 10842 (42U, 800mm wide) - Pallet HP Rack 10842 (42U, 800mm wide) - Shock Pallet HP Rack 10647 (47U) - Pallet HP Rack 10647 (47U) - Crated HP Rack 10642 (42U) - Pallet HP Rack 10642 (42U) - Shock Pallet HP Rack 10642 (42U) - Crated HP Rack 10636 (36U) - Pallet HP Rack 10636 (36U) - Shock Pallet HP Rack 10636 (36U) - Crated HP Rack 10622 (22U) - Pallet HP Rack 10622 (22U) - Shock Pallet HP Rack 10622 (22U) - Crated
NOTE:
NOTE:
NOTE:NOTE:
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels)
-B23 (crated) used for air shipments of empty racks. NOTE:
NOTE:
NOTE:NOTE:
-B21 (pallet) used to ship empty racks shipped on a truck
It is mandatory to use a shock pallet in order to ship racks with equipment installed.
257415-B21 257415-B22 245160-B21 245160-B23 245161-B21 245161-B22 245161-B23 245162-B21 245162-B22 245162-B23 245163-B21 245163-B22 245163-B23
DA - 11050 Canada — Version 13 — July 19, 2004
Page 12
QuickSpecs
Configuration Information
Step 8: Expansion Options
Step 8: Expansion Options
Step 8: Expansion OptionsStep 8: Expansion Options
SAN Conversion Options
SAN Conversion Options
SAN Conversion OptionsSAN Conversion Options
Modular Smart Array 1000 Controller MSA Fibre Channel I/O Module MSA SAN Switch 2/8 (Integrated) FCA2101 Host Adapter (Microsoft) FCA2210 Host Adapter (NetWare) FAC2214 Host Adapter (Microsoft/Linux) 2Gb/s SFP SW Transceiver Kit Modular Smart Array 30 Single Bus (rack-mountable)
NOTE:
NOTE:
NOTE: NOTE: Switch 2/8) are required for conversion. To obtain conversion procedure document go to
http://www.hp.com/go/msa500
Smart Array 1000 for Additional Scalability document.
The MSA 1000 controller and the MSA 1000 Fibre Channel I/O module (or the MSA SAN
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
and download "Converting Modular Smart Array 500 to a Modular
218231-B22 218960-B21 288247-B21 245299-B21 281540-B21 281541-B21 221470-B21 302969-B21
DA - 11050 Canada — Version 13 — July 19, 2004
Page 13
QuickSpecs

Technical Specifications

Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500Modular Smart Array 500
LED Indicators on Front
LED Indicators on Front
LED Indicators on FrontLED Indicators on Front (3)
LED Indicators for Drive
LED Indicators for Drive
LED Indicators for DriveLED Indicators for Drive Modules
Modules
ModulesModules
LED Indicators on Rear
LED Indicators on Rear
LED Indicators on RearLED Indicators on Rear Panel
Panel
PanelPanel
Interface
Interface
InterfaceInterface
Maximum Number of
Maximum Number of
Maximum Number ofMaximum Number of Drives
Drives
DrivesDrives Temperature Range
Temperature Range
Temperature RangeTemperature Range
Relative Humidity
Relative Humidity
Relative HumidityRelative Humidity
Input Power Requirements
Input Power Requirements
Input Power RequirementsInput Power Requirements
Heat Dissipation
Heat Dissipation
Heat DissipationHeat Dissipation (maximum)
2-Port SCSI I/O Module
2-Port SCSI I/O Module
2-Port SCSI I/O Module2-Port SCSI I/O Module
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500Modular Smart Array 500 Cabinet
Cabinet
CabinetCabinet
Shipping Packaging
Shipping Packaging
Shipping PackagingShipping Packaging
(3)
(4)
Power Fault detected in one or more sub-systems Fault in Enclosure Management Drive Access (centre) Online (left) Drive Failure (right) Power Supply/Blower Assembly Fault (1) EMU (3): Power; A bus; B bus Ultra3 SCSI to Hard Drives Ultra3 SCSI to Host Servers 14, 1-in Ultra320, Ultra3 or Ultra2 Universal Hard Drives (Modular Smart Array 500 cabinet)
Operating
Operating
OperatingOperating Shipping
Shipping
ShippingShipping
Operating
Operating
OperatingOperating Non-operating
Non-operating
Non-operatingNon-operating Rated Input Voltage
Rated Input Voltage
Rated Input VoltageRated Input Voltage Rated Input Frequency
Rated Input Frequency
Rated Input FrequencyRated Input Frequency Rated Input Current
Rated Input Current
Rated Input CurrentRated Input Current Input Power
Input Power
Input PowerInput Power 1876 Btu/hr*
*Input Power and Heat Dissipation specifications are maximum values and apply to worst-case conditions at full rated power supply load. The power/heat dissipation for your installation will vary depending on the equipment configuration.
Ports
Ports
PortsPorts Dimensions
Dimensions
DimensionsDimensions Weight
Weight
WeightWeight 4U Rack Form Factor Dimensions
Dimensions
DimensionsDimensions Weight
Weight
(Net)
WeightWeight Dimensions
Dimensions
DimensionsDimensions Weight
Weight
(Gross)
WeightWeight
(max)
(H x W x D)
(L x W x D)
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
50° to 95° F (10° to 35° C)
-2° to 122° F (-0° to 50° C)
NOTE:
NOTE:
Rated 1°C per 1000 feet of elevation to 10000 ft.
NOTE:NOTE:
10% to 90% Up to 95% 100 to 240 VAC 50 to 60 Hz
2.3 A at12 VAC typical, 6A Maximum 549 W*
2 VHDCI Ultra3 SCSI ports
4.5 x 1.375 x 9.5 in (11.4 x 3.5 x 24.1 cm)
1.3 lb (0.6 Kg)
6.9 x 19 x 20.5 in (17.5 x 48.3 x 52.1 cm) 50 lb (22.5 kg)
33.7 x 14.8 x 33.8 in (85.6 x 37.5 x 85.9 cm) 70 to 105 lb (31.5 kg)
DA - 11050 Canada — Version 13 — July 19, 2004
Page 14
QuickSpecs
Technical Specifications
Modular Smart Array 500 Controller
Modular Smart Array 500 Controller
Modular Smart Array 500 ControllerModular Smart Array 500 Controller
User Interface
User Interface
User InterfaceUser Interface
Electrical Interface
Electrical Interface
Electrical InterfaceElectrical Interface Protocol Support
Protocol Support
Protocol SupportProtocol Support SCSI Ports
SCSI Ports
SCSI PortsSCSI Ports Drives Supported
Drives Supported
Drives SupportedDrives Supported Maximum Capacity
Maximum Capacity
Maximum CapacityMaximum Capacity Logical Drives
Logical Drives
Logical DrivesLogical Drives RAID Support
RAID Support
RAID SupportRAID Support
Cache Memory
Cache Memory
Cache MemoryCache Memory
Cache Batteries
Cache Batteries
Cache BatteriesCache Batteries Upgradeable Firmware
Upgradeable Firmware
Upgradeable FirmwareUpgradeable Firmware Disk Drive and Enclosure
Disk Drive and Enclosure
Disk Drive and EnclosureDisk Drive and Enclosure Protocol Support
Protocol Support
Protocol SupportProtocol Support Packaging
Packaging
PackagingPackaging
Controller Display with Status Indicators (2) and Push Buttons (4) Status Indicators on front of Controller (16)
LVD (Low Voltage Differential) Wide Ultra3 SCSI (160 MB/s per channel) 2 external VHDCI connectors standard. Optional 4-Port Shared Storage Module with 4 VHDCI connectors. Up to 14 drives
2.0 TB (14 drives x 146.8GB) Up to 32 logical drives RAID ADG (Advanced Data Guarding) RAID 5 (Distributed Data Guarding) RAID 1+0 (Striping & Mirroring) RAID 1 (Mirroring) RAID 0 (Striping) Standard 128 MB Read/Write Cache Up to 512 MB Read/Write ECC protection, battery-backed, and removable
NOTE:
NOTE:
The Modular Smart Array Controller allows the following cache configurations:
NOTE:NOTE: 1 x 128 MB; 2 x 128 MB; 1 x 256 MB; 2 x 256 MB.
NOTE:
NOTE:
When redundant controllers are installed, the cache configurations in both controllers must be identical.
NOTE:NOTE:
Up to three days of redundant battery life, removable for easy replacement 2 MB flashable ROM Ulltra320, Ultra3 and Ultra2 SCSI 1-inch Universal drives
Dimensions
Dimensions
DimensionsDimensions Weight
Weight
WeightWeight
(L x W x D)
(Gross)
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
14.5 x 11.5 x 3.1 in (36.8 x 29.2 x 8 cm) 6 lb (2.72 kg)
4-port Shared Storage I/O Module (option)
4-port Shared Storage I/O Module (option)
4-port Shared Storage I/O Module (option)4-port Shared Storage I/O Module (option)
Connector Type
Connector Type
Connector TypeConnector Type Ports
Ports
PortsPorts Bandwidth
Bandwidth
BandwidthBandwidth Protocols/HBA Supported
Protocols/HBA Supported
Protocols/HBA SupportedProtocols/HBA Supported Packaging
Packaging
PackagingPackaging
MSA500 High Availability Kit (option)
MSA500 High Availability Kit (option)
MSA500 High Availability Kit (option)MSA500 High Availability Kit (option)
Contents
Contents
ContentsContents
Packaging
Packaging
PackagingPackaging
VHDCI Ultra3 SCSI 4 Ultra3 SCSI 160 MB/s per port Ultra320, Ultra3 and Ultra2 SCSI/Smart Array 532, Smart Array 5i adapters Dimensions
Dimensions
DimensionsDimensions Weight
Weight
WeightWeight
MSA500 Controller, 4-port Shared Storage I/O Module, 2 6ft. SCSI Cables, 2 SA-532 Adapters, and Smart Array Multipath Software 2.0
Dimensions
Dimensions
DimensionsDimensions Weight
Weight
WeightWeight
(L x W x D)
(Gross)
(L x W x D)
(Gross)
14.5 x 11.5 x 3.1 in (36.8 x 29.2 x 8 cm) 6 lb (2.72 kg)
22.6 x 18.6 x 12.4 in (57.5 x 47.3 x 31.4 cm)
14.2 lb (6.5 kg)
DA - 11050 Canada — Version 13 — July 19, 2004
Page 15
QuickSpecs
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
Technical Specifications
© Copyright 2002-2004 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
DA - 11050 Canada — Version 13 — July 19, 2004
Page 16