HP StorageWorks Modular Smart Array 500 Overview

QuickSpecs

Overview

HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
1. Display
2. Display Buttons
3. Display Indicators
4. Modular Smart Array Controller
1. Power Supply/Blower Indicators
2. Power Supply/Blower Assemblies
3. SCSI Port A
5. Power Switch
6. Status Indicators
7. Redundant Controller Slot Blank
4. SCSI Port B
5. SCSI I/O Indicators
6. SCSI I/O with Integrated Environmental Monitoring Unit (EMU)
DA - 11050 Canada — Version 13 — July 19, 2004
Page 1
QuickSpecs
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
Overview
What's New
What's New
What's NewWhat's New
New name, formerly named Smart Array Cluster Storage MSA500 Starter Kit with 2 host adapters included MSA500 High Availability Kit includes everything needed to make MSA500 system fully redundant at a new low price Microsoft® Windows® Server 2003 Support UnitedLinux 1.0 Support Novell NetWare 6.5 Support Storage sharing with up to 4 direct attached servers
At A Glance
At A Glance
At A GlanceAt A Glance
Two node high availability clustering Shared storage for up to 4 ProLiant servers Redundant capable Smart Array Controllers with LCD screen to show system status messaging. Total storage capacity of 2TB, by using 14 HP Universal U320 Hard Disks of 146.8 GB each Multipath connectivity option with load balancing Redundant Power Supplies and Fans standard Fully convertible to HP StorageWorks Modular Smart Array 1000 RAID 0, 1, 1+0, 5 and ADG standard Supports up to 512 MB of Battery Backed Cache (2x256 MB). Pre-Failure Warranty that covers disk drives
DA - 11050 Canada — Version 13 — July 19, 2004
Page 2
QuickSpecs
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500

Standard Features

Modular Smart Array Family
Modular Smart Array Family
Modular Smart Array FamilyModular Smart Array Family The HP StorageWorks Modular Smart Array family delivers easy, affordable storage technology to meet today's demanding and growing IT needs. These
storage solutions offer the best price/performance features for direct attach environments, small clusters, workgroup sharing and entry-level SAN environments. Each solution is designed to be easy to deploy, secure, reduce management costs, while driving rapid return on investment.
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500Modular Smart Array 500 The HP StorageWorks Modular Smart Array 500 (MSA 500), formerly named Modular Smart Array 500, is an Ultra3 SCSI (supporting Ultra320 hard drives)
storage system, supporting up to 2TB of data capacity, designed specifically for 2-node clustering and multiple node (up to 4 servers) shared storage. Designed to reduce the complexity and expense of clustering and storage sharing, the Modular Smart Array 500 is built upon Smart Array and ProLiant technologies to provide advanced data protection features yet is simple to deploy, configure and manage. Ideal for entry level clustering and shared storage, the Modular Smart Array 500 is familiar SCSI technology, making it a simple and powerful storage platform. As the customer's clustering and storage requirements grow, the Modular Smart Array 500 may be converted to a SAN array by replacing the controller(s) and I/O module and installing a MSA 1000 FC I/O module, or MSA 1000 FC switch, providing the customer with extended hardware investment protection into the future. The Modular Smart Array 500 combines the array controller shelf and the drive shelf, which holds up to fourteen 1 HP Universal Disk drives in a single 4U rack mount cabinet, that's over 2 terabytes of storage.
Key Features
Key Features
Key FeaturesKey Features
High performance Modular Smart Array controller(s) with LCD for system status messages. Standard 128-MB Battery Backed Cache, upgradeable to 512 MB maximum. Optional redundant Modular Smart Array controller. 4U rack mount chassis combining both the controller and disk shelf. Ultra3 SCSI back panel and drive interconnect. SSP (Selective Storage Presentation) for storage sharing with multiple servers. 2TB capacities with support of 14 Ultra320, Ultra3 and Ultra2 Universal 1 Drives. Redundant power supplies and fans are standard. RAID levels 0, 1, 1 0, 5, RAID ADG. Optional 4-Port Shared Storage Module with Smart Array Multipath software with load balancing. Optional ProLiant Essentials Recovery Server Option Convertible to MSA 1000 for capacity expansion and increased host connections Remote configuration and monitoring via ACU & Insight Manager 7. Qualified and certified for Windows, Linux and NetWare 2-node clustering Support for select ProLiant servers (see Server Compatibility on page 14 or
http://www.hp.com/go/msa
for latest compatibility).
DA - 11050 Canada — Version 13 — July 19, 2004
Page 3
QuickSpecs

Product Highlights

Modular Smart Array 500 Highlights
Modular Smart Array 500 Highlights
Modular Smart Array 500 HighlightsModular Smart Array 500 Highlights
High Levels of
High Levels of
High Levels ofHigh Levels of Performance, Data
Performance, Data
Performance, DataPerformance, Data Protection and
Protection and
Protection andProtection and Functionality
Functionality
FunctionalityFunctionality
High Availability
High Availability
High AvailabilityHigh Availability Novell NetWare environments. High Performance
High Performance
High PerformanceHigh Performance Plus embedded controller in the ProLiant servers. Storage Capacity
Storage Capacity
Storage CapacityStorage Capacity maximum of 2TB of shared storage capacity using HP 146.8 Ultra320 SCSI Universal 1" hard drives. Data Protection
Data Protection
Data ProtectionData Protection controllers (optional), redundant fans and power supplies (standard); multiple I/O path capability with Smart Array Multipath software option, support for Hot Pluggable AIT and DAT tape drives in the storage enclosure, transportable battery-backed cache and RAID ADG (standard). Storage Manageability
Storage Manageability
Storage ManageabilityStorage Manageability such as Smart Array Configuration Utility and Insight Manager. Online Management Features: Online Capacity Expansion (single path only), Online RAID Level Migration, Online Stripe Size Migration, Online Spares (Global), User Selectable Read/Write cache, User Selectable Expand and Rebuild Priority. Choice of Computing Platform
Choice of Computing Platform
Choice of Computing PlatformChoice of Computing Platform Advanced Data Guarding (RAID ADG) Fault Tolerance
Advanced Data Guarding (RAID ADG) Fault Tolerance
Advanced Data Guarding (RAID ADG) Fault ToleranceAdvanced Data Guarding (RAID ADG) Fault Tolerance tolerance. It allocates two sets of parity data across drives and allows simultaneous write operations. This level of fault tolerance can withstand two simultaneous drive failures without downtime or data loss.
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
– supports a broad range of clustering options for Microsoft Windows Server, Linux Server and
– Data transmission rate of 14,000 IOPS – 2 Node cluster configuration using Smart Array 5i
– The Modular Smart Array 500 cabinet supports up to fourteen 1" Universal hard drives, for a
– Modular Smart Array 500 is designed for a high level of data protection. It includes redundant
– The Smart Array Controllers feature familiar configuration and management tools
– The Modular Smart Array 500 is designed and qualified for ProLiant servers.
– This is the highest level of RAID fault
DtS (DAS to SAN)
DtS (DAS to SAN)
DtS (DAS to SAN)DtS (DAS to SAN) Technology
Technology
TechnologyTechnology
Low Total Cost of
Low Total Cost of
Low Total Cost ofLow Total Cost of Ownership
Ownership
OwnershipOwnership
The Smart Array architecture provides a quick and easy way to migrate from the Modular Smart Array 500 to the Modular Storage Array 1000 (MSA 1000). In order to convert the Modular Smart Array 500 to a SAN, simply remove the Modular Smart Array Controller(s) and replace them with StorageWorks MSA 1000 Controller(s) and add FC I/O board or FC Switch (please refer to MSA 1000 Quickspecs for additional SAN requirements information). This is referred to as DtS technology (DAS-to-SAN technology). In addition to convertibility to the SAN, the Modular Smart Array 500 allows the seamless migration of stored data in ProLiant servers protected by Smart Array PCI controllers to a Modular Smart Array 500 system. Data that is currently stored on 1" Universal disk drives using HP Smart Array controllers, as well as data on an RA4100 can easily be migrated to the Modular Smart Array 500. Simply remove the drives from the older systems and insert them into the Modular Smart Array
500. Existing data and configuration will remain intact. In addition, the RAID set and data will be preserved allowing migration to be completed in minutes, not hours.
The modular, scalable design of the Modular Smart Array 500 provides an extremely flexible platform. You can buy what you need today and purchase additional capacity and performance as your data storage needs grow, instead of making a large up-front investment. Additional drives, controllers, and cache can be easily added as your needs dictate.
Storage Consolidation
Storage Consolidation
Storage ConsolidationStorage Consolidation internal storage to the Modular Smart Array 500. Universal Hard Drive
Universal Hard Drive
Universal Hard DriveUniversal Hard Drive disk drives is protected and cost is minimized as you add new drives. Sharing of a common universal drive form factor between your server and storage can significantly reduce needs for hardware and spare inventory, and offer overall reduction in storage management and business costs. Pre-Failure Warranty
Pre-Failure Warranty
Pre-Failure WarrantyPre-Failure Warranty are supported by a Pre-Failure (replacement) Warranty. Pre-Failure Warranty allows for the replacement of designated drives in Modular Smart Array 500 before they actually fail when using Insight Manager on ProLiant servers.
NOTE:
NOTE:
Some operating systems may not support all of these features.
NOTE:NOTE:
Integrated Configuration and Management Tools
Integrated Configuration and Management Tools
Integrated Configuration and Management ToolsIntegrated Configuration and Management Tools integrated set of Smart Array management and utility software. These tools consistently lower the cost of ownership by reducing training and technical expertise necessary to install and maintain HP server storage.
– Improve storage utilization and lower storage management cost through moving
– Since the Modular Smart Array 500 supports Universal 1" SCSI drives, your investment in
– Drives installed in a Modular Smart Array 500 and monitored under Insight Manager
– The Modular Smart Array 500 utilizes the standard,
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500Modular Smart Array 500
The 4U array houses up to fourteen 1" Universal hot pluggable Ultra320, Ultra3 and/or Ultra2 drives. Each Modular Smart Array 500 includes the following standard components: Modular Smart Array 500 Controller, 2-port Ultra3 SCSI I/O Module, dual hot pluggable fans/power supplies, two power cables, two VHDCI SCSI cables and a crossover Ethernet cable.
DA - 11050 Canada — Version 13 — July 19, 2004
Page 4
QuickSpecs

Modular Smart Array 500 Components

Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500Modular Smart Array 500 Controller
Controller
ControllerController
4-Port Shared Storage
4-Port Shared Storage
4-Port Shared Storage4-Port Shared Storage Module with Smart Array
Module with Smart Array
Module with Smart ArrayModule with Smart Array Multipath
Multipath
MultipathMultipath
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500Modular Smart Array 500 Controller Management
Controller Management
Controller ManagementController Management Features
Features
FeaturesFeatures
The Modular Smart Array 500 Controller is an integrated RAID controller with an integrated LCD/LED status display and 128-MB read/write battery-backed cache (expandable to 512MB per controller). One Modular Smart Array 500 Controller is included with the Modular Smart Array 500; the redundant Modular Smart Array 500 Controller is an option..
The 4-Port Shared Storage Module is an option which may be used in one of two configurations:
Enhance cluster fault tolerance by adding multiple paths from the host servers to the shared storage. This provides an additional level of fault tolerance by adding redundancy to both the HBA in the host server as well as the SCSI cables connecting the host servers to the shared storage. Attach up to four independent servers to the Modular Smart Array 500. The storage capacity to each server is assigned with SSP (Shared Storage Presentation), a feature of the Array Configuration Utility. Using SSP and sharing storage among multiple host servers maximizes hard drive capacity utilization, and allows for additional hard drive capacity to be deployed (up to 14) with the volume extension and capacity expansion capabilities.
Online RAID Level Migration: allows for online post-configuration change to RAID level without destroying data or volume information. Online Capacity Expansion: allows for adding storage to an operational Modular Smart Array 500-reducing expensive server downtime (single path configuration only). Online Volume Extension: allows for the capacity growth of existing logical volumes (single path configuration only). Logical Drive Capacity Extension: allows the user to increase the size of existing logical drives online under Windows NT® and offline for other operating systems. Online Stripe Size Migration: Allows changing stripe sizing of a logical drive. User Selectable Read/Write Cache size, allocate cache sizes. User Selectable Expand and Rebuild Priority.
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500HP StorageWorks Modular Smart Array 500
Controller Firmware
Controller Firmware
Controller FirmwareController Firmware Cloning
Cloning
CloningCloning
Multi Host Storage
Multi Host Storage
Multi Host StorageMulti Host Storage Sharing
Sharing
SharingSharing
RAID
RAID
RAIDRAID
Enhanced Controller Firmware Auto-Cloning allows customer choice of controller firmware version when adding redundant controller with different firmware version.
Selective Storage Presentation (SSP) support standard on both the base 2-port model of Modular Smart Array 500 as well as the optional 4-port Shared Storage Module. SSP allows the administrator to create volumes and assign access rights to a particular host server. This allows sharing the Modular Smart Array 500 with up to 4 host servers maximizing storage capacity utilization. SSP also allows online capacity expansion as well as online volume extension in DAS configurations.
Several fault tolerant configurations keep data available and servers running while drives are being replaced, including:
Advanced Data Guarding (RAID ADG): Allocates the equivalence of 2 parity drives across multiple drives and allows simultaneous write operations. Distributed Data Guarding (RAID 5): Allocates parity data across multiple drives and allows simultaneous write operations. Drive Mirroring (RAID 1 and 1+0 Striped Mirroring): Allocates half of the drive array to data and the other half to mirrored data, providing two copies of every file.
DA - 11050 Canada — Version 13 — July 19, 2004
Page 5