Copyright 2017 Hewlett Packard Enterprise Development LP
Notices
The information contained herein is subject to change without notice. The only warranties for Hewlett Packard
Enterprise products and services are set forth in the express warranty statements accompanying such
products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett
Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.
Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use,
or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software
Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under
vendor's standard commercial license.
Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard
Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterprise
website.
The HPE ProLiant ML110 Gen10 Server delivers a performance that meets the growing needs of the SMB.
The server is a single processor, 4.5U Tower Server that is designed to provide enterprise class features such
as redundancy, reliability, and manageability. The server delivers the right size Tower with performance and
expandability that covers a wide range of applications and workloads and addresses our customers from SMB
to enterprise class server ROBO environments. Accelerate your business with this right-sized compute.
4 Product overview
Setting up and installing
Optional service
Delivered by experienced, certified engineers, Hewlett Packard Enterprise support services help you keep
your servers up and running with support packages tailored specifically for HPE ProLiant systems. Hewlett
Packard Enterprise support services let you integrate both hardware and software support into a single
package. A number of service level options are available to meet your business and IT needs.
Hewlett Packard Enterprise support services offer upgraded service levels to expand the standard product
warranty with easy-to-buy, easy-to-use support packages that will help you make the most of your server
investments. Some of the Hewlett Packard Enterprise support services for hardware, software or both are:
•Foundation Care – Keep systems running.
◦6-Hour Call-to-Repair
◦4-Hour 24x7
◦Next Business Day
•Proactive Care – Help prevent service incidents and get you to technical experts when there is one.
◦6-Hour Call-to-Repair
◦4-Hour 24x7
◦Next Business Day
•Deployment service for both hardware and software
•Hewlett Packard Enterprise Education Services – Help train your IT staff.
1
The time commitment for this repair service might vary depending on the site's geographical region. For
more service information available in your site, contact your local
center.
For more information on Hewlett Packard Enterprise support services, see the Hewlett Packard Enterprisewebsite.
1
1
Hewlett Packard Enterprise support
Operational requirements
Space and airflow requirements
To allow for servicing and adequate airflow, observe the following space and airflow requirements when
deciding where to install a rack:
•Leave a minimum clearance of 63.5 cm (25 in) in front of the rack.
•Leave a minimum clearance of 76.2 cm (30 in) behind the rack.
•Leave a minimum clearance of 121.9 cm (48 in) from the back of the rack to the back of another rack or
row of racks.
Setting up and installing5
Hewlett Packard Enterprise servers draw in cool air through the front door and expel warm air through the
rear door. Therefore, the front and rear rack doors must be adequately ventilated to allow ambient room air to
enter the cabinet, and the rear door must be adequately ventilated to allow the warm air to escape from the
cabinet.
CAUTION:
To prevent improper cooling and damage to the equipment, do not block the ventilation openings.
When vertical space in the rack is not filled by a server or rack component, the gaps between the components
cause changes in airflow through the rack and across the servers. Cover all gaps with blanking panels to
maintain proper airflow.
CAUTION:
Always use blanking panels to fill empty vertical spaces in the rack. This arrangement ensures proper
airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal
damage.
The 9000 and 10000 Series Racks provide proper server cooling from flow-through perforations in the front
and rear doors that provide 64 percent open area for ventilation.
CAUTION:
If a third-party rack is used, observe the following additional requirements to ensure adequate airflow
and to prevent damage to the equipment:
•Front and rear doors—If the 42U rack includes closing front and rear doors, you must allow 5,350 sq
cm (830 sq in) of holes evenly distributed from top to bottom to permit adequate airflow (equivalent to
the required 64 percent open area for ventilation).
•Side—The clearance between the installed rack component and the side panels of the rack must be
a minimum of 7 cm (2.75 in).
Temperature requirements
To ensure continued safe and reliable equipment operation, install or position the system in a well-ventilated,
climate-controlled environment.
The maximum recommended ambient operating temperature (TMRA) for most server products is 35°C
(95°F). The temperature in the room where the rack is located must not exceed 35°C (95°F).
CAUTION:
To reduce the risk of damage to the equipment when installing third-party options:
•Do not permit optional equipment to impede airflow around the server or to increase the internal rack
temperature beyond the maximum allowable limits.
•Do not exceed the manufacturer’s TMRA.
Power requirements
Installation of this equipment must comply with local and regional electrical regulations governing the
installation of information technology equipment by licensed electricians. This equipment is designed to
operate in installations covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992 (code
for Protection of Electronic Computer/Data Processing Equipment). For electrical power ratings on options,
refer to the product rating label or the user documentation supplied with that option.
6 Temperature requirements
WARNING:
To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply
branch circuit that provides power to the rack. Consult the electrical authority having jurisdiction over
wiring and installation requirements of your facility.
CAUTION:
Protect the server from power fluctuations and temporary interruptions with a regulating uninterruptible
power supply. This device protects the hardware from damage caused by power surges and voltage
spikes and keeps the system in operation during a power failure.
Electrical grounding requirements
The server must be grounded properly for proper operation and safety. In the United States, you must install
the equipment in accordance with NFPA 70, 1999 Edition (National Electric Code), Article 250, as well as any
local and regional building codes. In Canada, you must install the equipment in accordance with Canadian
Standards Association, CSA C22.1, Canadian Electrical Code. In all other countries, you must install the
equipment in accordance with any regional or national electrical wiring codes, such as the International
Electrotechnical Commission (IEC) Code 364, parts 1 through 7. Furthermore, you must be sure that all
power distribution devices used in the installation, such as branch wiring and receptacles, are listed or
certified grounding-type devices.
Because of the high ground-leakage currents associated with multiple servers connected to the same power
source, Hewlett Packard Enterprise recommends the use of a PDU that is either permanently wired to the
building’s branch circuit or includes a nondetachable cord that is wired to an industrial-style plug. NEMA
locking-style plugs or those complying with IEC 60309 are considered suitable for this purpose. Using
common power outlet strips for the server is not recommended.
Server warnings and cautions
WARNING:
This server is heavy. To reduce the risk of personal injury or damage to the equipment:
•Observe local occupational health and safety requirements and guidelines for manual material
handling.
•Get help to lift and stabilize the product during installation or removal, especially when the product is
not fastened to the rails. Hewlett Packard Enterprise recommends that a minimum of two people are
required for all rack server installations. A third person may be required to help align the server if the
server is installed higher than chest level.
•Use caution when installing the server in or removing the server from the rack; it is unstable when
not fastened to the rails.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
WARNING:
To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power
cord to remove power from the server. The front panel Power On/Standby button does not completely
shut off system power. Portions of the power supply and some internal circuitry remain active until AC
power is removed.
Electrical grounding requirements7
CAUTION:
Protect the from power fluctuations and temporary interruptions with a regulating UPS. This device
protects the hardware from damage caused by power surges and voltage spikes and keeps the in
operation during a power failure.
CAUTION:
Do not operate the server for long periods with the access panel open or removed. Operating the server
in this manner results in improper airflow and improper cooling that can lead to thermal damage.
Rack warnings
WARNING:
To reduce the risk of personal injury or damage to the equipment, be sure that:
•The rack is bolted to the floor using the concrete anchor kit.
•The leveling feet extend to the floor.
•The full weight of the rack rests on the leveling feet.
•The racks are coupled together in multiple rack installations.
•Only one component is extended at a time. If more than one component is extended, a rack might
become unstable.
WARNING:
To reduce the risk of personal injury or equipment damage when unloading a rack:
•At least two people are needed to safely unload the rack from the pallet. An empty 42U rack can
weigh as much as 115.0 kg (253.0 lb), can stand more than 2.1 m (7.0 ft) tall, and might become
unstable when being moved on its casters.
•Never stand in front of the rack when it is rolling down the ramp from the pallet. Always handle the
rack from both sides.
WARNING:
To reduce the risk of personal injury or damage to the equipment, adequately stabilize the rack before
extending a component outside the rack. Extend only one component at a time. A rack may become
unstable if more than one component is extended.
WARNING:
When installing a system in a telco rack, be sure that the rack frame is adequately secured at the top
and bottom to the building structure.
WARNING:
Both default fan and redundant fan Kit are rack mode supported. However increased cooling mode
enablement is required at default fan in RBSU options.
8 Rack warnings
Enabling increased cooling in RBSU
Procedure
1. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration
(RBSU) > Advanced Options > Fan and Thermal Options > Thermal Configuration.
2. Select Increased Cooling—Operates fans at a higher speed.
3. Save your setting.
Electrostatic discharge
Be aware of the precautions you must follow when setting up the system or handling components. A
discharge of static electricity from a finger or other conductor may damage system boards or other staticsensitive devices. This type of damage may reduce the life expectancy of the system or component.
To prevent electrostatic damage:
•Avoid hand contact by transporting and storing products in static-safe containers.
•Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
•Place parts on a grounded surface before removing them from their containers.
•Avoid touching pins, leads, or circuitry.
•Always be properly grounded when touching a static-sensitive component or assembly. Use one or more
of the following methods when handling or installing electrostatic-sensitive parts:
◦Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist
straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords. To
provide proper ground, wear the strap snug against the skin.
◦Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when
standing on conductive floors or dissipating floor mats.
◦Use conductive field service tools.
◦Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an authorized reseller
install the part.
For more information on static electricity or assistance with product installation, contact an authorized reseller.
Prerequisites for the initial server setup
Procedure
Verify that the optimum environmental requirements are satisfied.
Confirm that the installation engineer understands how to integrate the server into the user network, in
particular from an IP addressing perspective and from a domain perspective.
Enabling increased cooling in RBSU9
Prepare Ethernet cables of an appropriate length for each of the LAN, WAN, and remote management
(iLO) connections.
Verify that there are sufficient ports available on the devices to which the server will be connected (for
example, router, LAN switch).
Server box contents
Unpack the server shipping carton and locate the materials and documentation necessary for installing the
server.
The server shipping box contains
•Server (Tower or Rack model)
The server model will depend on the configuration ordered by the customer
•Power cord
•Hardware documentation
Setting up the server in tower mode
Procedure
1. Remove the server from the rack.
2. Turn the server to the upright position.
3. Place the server on a flat stable surface.
4. Connect peripheral devices to the server.
WARNING:
To reduce the risk of electric shock or damage to the equipment:
•Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
•Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all
times.
•Unplug the power cord from the power supply to disconnect power to the equipment.
•Do not route the power cord where it can be walked on or pinched by items placed against it. Pay
particular attention to the plug, electrical outlet, and the point where the cord extends from the
server.
5. Connect the power cord to the rear of the server.
6. Connect the power cord to the AC power source.
10 Server box contents
Setting up the server in rack mode
Procedure
1. Install the server into the rack.
For more information, see the installation instructions that ship with the Tower to Rack Conversion Kit.
2. Connect peripheral devices to the server.
WARNING:
To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or
telecommunications connectors into RJ-45 connectors.
3. Connect the power cord to the rear of the server.
4. Connect the power cord to the AC power source.
WARNING:
To reduce the risk of electric shock or damage to the equipment:
•Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
•Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all
times.
•Unplug the power cord from the power supply to disconnect power to the equipment.
•Do not route the power cord where it can be walked on or pinched by items placed against it. Pay
particular attention to the plug, electrical outlet, and the point where the cord extends from the
server.
Configuring the server
When the server is powered on, the POST screen is displayed. Use the following options to configure the
server:
•System utilities (F9)
Use this option to configure UEFI, RBSU, or other boot settings.
•Intelligent Provisioning (F10)
Use this option to configure drives, access Smart Storage Administrator, or begin installing or deploying an
operating system.
•Boot order (F11)
Use this option to select a boot device.
•Network boot (F12)
Use this option to PXE boot the server from the network.
Installing or deploying an operating system
Before installing an operating system, observe the following:
Setting up the server in rack mode11
•Be sure to read the HPE UEFI requirements for ProLiant servers on the Hewlett Packard Enterprisewebsite. If UEFI requirements are not met, you might experience boot failures or other errors when
installing the operating system.
•Update firmware before using the server for the first time, unless software or components require an older
version.
•For the latest information on supported operating systems, see the Hewlett Packard Enterprise website.
•The server does not ship with OS media. All system software and firmware is preloaded on the server.
Registering the server
To experience quicker service and more efficient support, register the server at the My License Portal website:
https://myenterpriselicense.hpe.com/
12 Registering the server
Specifications
Environmental specifications
SpecificationValue
Temperature range
Operating10°C to 35°C (41°F to 1045°F)
Nonoperating-30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)—
Operating8% to 90%
1
—
28°C (82.4°F), maximum wet bulb temperature
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1000 ft) to 3050 m
(10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper
limit and rate of change might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
•5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 1.0°C
per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft)
•A redundant fan is required when the ambient temperature reaches 35°C to 40°C.
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise website
(http://www.hpe.com/servers/ASHRAE).
Server specifications
Dimension (with feet/bezel)Value
Height44.00 cm (17.32 in)
Depth48.05 cm (18.92 in)
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Width19.50 cm (7.68 in)
Weight (approximate)
Minimum (one drive, power supply, and processor
installed)
Maximum (all drives, power supplies, and processors
installed)
13.5 kg (29.82 lb)
25.0 kg (55.00 lb)
Specifications13
Power supply specifications
Depending on the installed options and/or the regional location where the server was purchased, the server is
configured with one of the following power supplies:
•ATX 350W non-hot-plug power supply
•ATX 550W non-hot-plug power supply
•HPE 800W Flex Slot Platinum Hot-plug Low Halogen Power Supply
CAUTION:
Check the system and power supply input ratings before powering up the server.
NOTE: ATX power supply will not support redundant fan option.
ATX 350W non-hot-plug power supply
SpecificationValue
Input requirements
Rated input voltage
Rated input frequency50 Hz to 60 Hz
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Rated steady-state power
Maximum peak power
ATX 550W non-hot-plug power supply
SpecificationValue
100 VAC to 240 VAC
4.5 A at 100 VAC
1.9 A at 240 VAC
437 W at 100 VAC
416 W at 240 VAC
1491 at 100 VAC
1419 at 240 VAC
350 W at 100VAC to 240VAC
385 W at 100VAC to 240VAC
Input requirements
Rated input voltage
Rated input frequency50 Hz to 60 Hz
14 Power supply specifications
100 VAC to 240 VAC
Table Continued
SpecificationValue
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Rated steady-state power
Maximum peak power
6.4 A at 100 VAC
2.62 A at 240 VAC
634 W at 100 VAC
613 W at 240 VAC
1876 at 100 VAC
1876 at 240 VAC
550 W at 100VAC to 240VAC
575 W at 100VAC to 240VAC
HPE 800W Flex Slot Platinum Hot Plug Low Halogen Power Supply
SpecificationValue
Input requirements
Rated input voltage
100 VAC to 127 VAC
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
100 VAC to 240 VAC
240 VDC for China only
50 Hz to 60 Hz
Not applicable to 240 VDC
9.4 A at 100 VAC
4.5 A at 200 VAC
3.8 A at 240 VDC for China only
899 W at 100 VAC
867 W at 200 VAC
864 W at 240 VDC for China only
3,067 at 100 VAC
2,958 at 200 VAC
2,949 at 240 VAC for China only
Table Continued
HPE 800W Flex Slot Platinum Hot Plug Low Halogen Power Supply15
•Service Pack for ProLiant (SPP) update: http://www.hpe.com/servers/spp/download
information for HPE ProLiant ML110 Gen10 Server17
Local representative information
Manufacturer information:
Hewlett Packard Enterprise Company, 3000 Hanover Street, Palo Alto, CA 94304 U.S.
Local representative information Russian
Russia:
Belarus:
Kazakhstan:
Local representative information Kazakh
Russia:
Belarus:
Kazakhstan:
Manufacturing date
The manufacturing date is defined by the serial number.
CCSYWWZZZZ (serial number format for this product)
Valid date formats include:
18 Local representative information
•YWW, where Y indicates the year counting from within each new decade, with 2000 as the starting point;
for example, 238: 2 for 2002 and 38 for the week of September 9. In addition, 2010 is indicated by 0, 2011
by 1, 2012 by 2, 2013 by 3, and so forth.
•YYWW, where YY indicates the year, using a base year of 2000; for example, 0238: 02 for 2002 and 38 for
the week of September 9.
Local representative information19
Support and other resources
Accessing Hewlett Packard Enterprise Support
•For live assistance, go to the Contact Hewlett Packard Enterprise Worldwide website:
http://www.hpe.com/assistance
•To access documentation and support services, go to the Hewlett Packard Enterprise Support Center
website:
http://www.hpe.com/support/hpesc
Information to collect
•Technical support registration number (if applicable)
•Product name, model or version, and serial number
•Operating system name and version
•Firmware version
•Error messages
•Product-specific reports and logs
•Add-on products or components
•Third-party products or components
Accessing updates
•Some software products provide a mechanism for accessing software updates through the product
interface. Review your product documentation to identify the recommended software update method.
•To download product updates:
Hewlett Packard Enterprise Support Center
www.hpe.com/support/hpesc
Hewlett Packard Enterprise Support Center: Software downloads
www.hpe.com/support/downloads
Software Depot
www.hpe.com/support/softwaredepot
•To subscribe to eNewsletters and alerts:
www.hpe.com/support/e-updates
•To view and update your entitlements, and to link your contracts and warranties with your profile, go to the
Hewlett Packard Enterprise Support Center More Information on Access to Support Materials page:
www.hpe.com/support/AccessToSupportMaterials
20 Support and other resources
IMPORTANT:
Access to some updates might require product entitlement when accessed through the Hewlett Packard
Enterprise Support Center. You must have an HPE Passport set up with relevant entitlements.
Customer self repair
Hewlett Packard Enterprise customer self repair (CSR) programs allow you to repair your product. If a CSR
part needs to be replaced, it will be shipped directly to you so that you can install it at your convenience.
Some parts do not qualify for CSR. Your Hewlett Packard Enterprise authorized service provider will
determine whether a repair can be accomplished by CSR.
For more information about CSR, contact your local service provider or go to the CSR website:
http://www.hpe.com/support/selfrepair
Remote support
Remote support is available with supported devices as part of your warranty or contractual support
agreement. It provides intelligent event diagnosis, and automatic, secure submission of hardware event
notifications to Hewlett Packard Enterprise, which will initiate a fast and accurate resolution based on your
product's service level. Hewlett Packard Enterprise strongly recommends that you register your device for
remote support.
If your product includes additional remote support details, use search to locate that information.
Remote support and Proactive Care information
HPE Get Connected
www.hpe.com/services/getconnected
HPE Proactive Care services
www.hpe.com/services/proactivecare
HPE Proactive Care service: Supported products list
To view the warranty for your product or to view the Safety and Compliance Information for Server, Storage,
Power, Networking, and Rack Products reference document, go to the Enterprise Safety and Compliance
To view the regulatory information for your product, view the Safety and Compliance Information for Server,
Storage, Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise Support Center:
Hewlett Packard Enterprise is committed to providing our customers with information about the chemical
substances in our products as needed to comply with legal requirements such as REACH (Regulation EC No
1907/2006 of the European Parliament and the Council). A chemical information report for this product can be
found at:
www.hpe.com/info/reach
For Hewlett Packard Enterprise product environmental and safety information and compliance data, including
RoHS and REACH, see:
www.hpe.com/info/ecodata
For Hewlett Packard Enterprise environmental information, including company programs, product recycling,
and energy efficiency, see:
www.hpe.com/info/environment
Documentation feedback
Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us
improve the documentation, send any errors, suggestions, or comments to Documentation Feedback
(docsfeedback@hpe.com). When submitting your feedback, include the document title, part number, edition,
and publication date located on the front cover of the document. For online help content, include the product
name, product version, help edition, and publication date located on the legal notices page.
22 Regulatory information
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.