T-1 (3 mm) High Intensity
LED Lamps
Technical Data
H
HLMP-132X Series
HLMP-142X Series
HLMP-152X Series
Features
• High Intensity
• Choice of 3 Bright Colors
High Efficiency Red
Yellow
High Performance Green
• Popular T-1 Diameter
Package
• Selected Minimum
Intensities
• Narrow Viewing Angle
Package Dimensions
• General Purpose Leads
• Reliable and Rugged
• Available on Tape and Reel
Description
This family of T-1 lamps is
specially designed for applications requiring higher on-axis
intensity than is achievable with a
standard lamp. The light
generated is focused to a narrow
beam to achieve this effect.
Selection Guide
Minimum
Part Intensity
Number (mcd) at Color
HLMP- Description 10 mA (Material)
1320 Untinted 8.6 High Efficiency Red
Nondiffused (GaAsP on GaP)
1321 Tinted 8.6
Nondiffused
1-128
1420 Untinted 9.2 Yellow
Nondiffused (GaAsP on GaP)
1421 Tinted 9.2
Nondiffused
1520 Untinted 6.7 Green (GaP)
Nondiffused
1521 Tinted 6.7
Nondiffused
5964-9373E
Absolute Maximum Ratings at T
= 25°C
A
Parameter Red Yellow Green Units
Peak Forward Current 90 60 90 mA
Average Forward Current
DC Current
Power Dissipation
[2]
[3]
[1]
25 20 25 mA
30 20 30 mA
135 85 135 mW
Reverse Voltage (IR = 100 µA) 5 5 5 V
Transient Forward Current
[4]
500 500 500 mA
(10 µsec Pulse)
LED Junction Temperature 110 110 110 °C
Operating Temperature Range -55 to +100 -55 to +100 -20 to +100 °C
Storage Temperature Range -55 to +100
Lead Soldering Temperature 260°C for 5 seconds
[1.6 mm (0.063 in.) from body]
Notes:
1. See Figure 5 (Red), 10 (Yellow), or 15 (Green) to establish pulsed operating conditions.
2. For Red and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
3. For Red and Green series derate power linearly from 25°C at 1.8 mW/°C. For Yellow series derate power linearly from 50°C at
1.6 mW/°C.
4. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED
die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the
Absolute Maximum Ratings.
1-129