T-1 (3 mm) High Intensity LED Lamps
Technical Data
H
HLMP-132X Series HLMP-142X Series HLMP-152X Series

Features

• High Intensity
• Choice of 3 Bright Colors
High Efficiency Red Yellow High Performance Green
• Popular T-1 Diameter Package
• Selected Minimum Intensities
• Narrow Viewing Angle

Package Dimensions

• General Purpose Leads
• Reliable and Rugged
• Available on Tape and Reel

Description

This family of T-1 lamps is specially designed for applica­tions requiring higher on-axis intensity than is achievable with a standard lamp. The light generated is focused to a narrow beam to achieve this effect.

Selection Guide

Minimum
Part Intensity
Number (mcd) at Color
HLMP- Description 10 mA (Material)
1320 Untinted 8.6 High Efficiency Red
Nondiffused (GaAsP on GaP)
Nondiffused
1-128
1420 Untinted 9.2 Yellow
Nondiffused (GaAsP on GaP)
Nondiffused
1520 Untinted 6.7 Green (GaP)
Nondiffused
Nondiffused
5964-9373E
Absolute Maximum Ratings at T
= 25°C
A
Parameter Red Yellow Green Units
Peak Forward Current 90 60 90 mA Average Forward Current DC Current Power Dissipation
[2]
[3]
[1]
25 20 25 mA 30 20 30 mA
135 85 135 mW Reverse Voltage (IR = 100 µA) 5 5 5 V Transient Forward Current
[4]
500 500 500 mA (10 µsec Pulse)
LED Junction Temperature 110 110 110 °C Operating Temperature Range -55 to +100 -55 to +100 -20 to +100 °C
Storage Temperature Range -55 to +100 Lead Soldering Temperature 260°C for 5 seconds
[1.6 mm (0.063 in.) from body]
Notes:
1. See Figure 5 (Red), 10 (Yellow), or 15 (Green) to establish pulsed operating conditions.
2. For Red and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
3. For Red and Green series derate power linearly from 25°C at 1.8 mW/°C. For Yellow series derate power linearly from 50°C at
1.6 mW/°C.
4. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the Absolute Maximum Ratings.
1-129