This guide provides an overview of the architecture, general operation, and descriptions of the
major components that comprise the HPE Integrity MC990 X Server system. It also provides
the standard procedures for powering on and powering off the system, basic troubleshooting
and maintenance information, Foundation Software usage information, and important safety
and regulatory specifications.
Part Number: 855704-006
Published: January 2019
Edition: 6
Contents
HPE Integrity MC990 X Server overview............................................... 6
Copyright 2016, 2019 Hewlett Packard Enterprise Development LP
Notices
The information contained herein is subject to change without notice. The only warranties for Hewlett
Packard Enterprise products and services are set forth in the express warranty statements accompanying
such products and services. Nothing herein should be construed as constituting an additional warranty.
Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained
herein.
Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession,
use, or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer
Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government
under vendor's standard commercial license.
Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard
Enterprise has no control over and is not responsible for information outside the Hewlett Packard
Enterprise website.
Acknowledgements
Intel® and Intel Xeon® are trademarks of Intel Corporation in the in the U.S. and other countries.
Google® is a registered trademark of Google Inc.
Linux® is a registered trademark of Linus Torvalds in the U.S. and other countries.
Red Hat® is a registered trademark of Red Hat, Inc. in the United States and other countries.
SUSE LINUX is a registered trademark of Novell Inc.
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
NUMAlink® and NUMAflex® are trademarks or registered trademarks of Silicon Graphics International
Corp. or its subsidiaries in the United States and/or other countries worldwide.
HPE Integrity MC990 X Server overview
This chapter provides an overview of the physical and architectural aspects of the HPE Integrity MC990 X
system. The major components of the Integrity MC990 X system are described and illustrated.
The Integrity MC990 X system is an advanced symmetric multiprocessing (SMP) computer system with
multiple Intel processor sockets as a cache-coherent single system image (SSI). Each processor socket
in the system houses multiple compute cores.
In an SMP system, each MC990 X chassis contains memory that it shares with all other processors in the
system. Because the Integrity MC990 X system is modular, it combines the advantages of lower entrylevel cost with global scalability in processors, memory, and I/O. You can install and operate the Integrity
MC990 X system in your lab or server room. One 42U rack holds one or more MC990 X chassis, the rack
management controller (RMC) unit, power distribution units (PDU), and optional mass storage units.
MC990 X server chassis
The basic enclosure within the Integrity MC990 X system is the MC990 X server chassis. The MC990 X
server chassis contains one four-socket motherboard connected to support up to 28 NUMAlink ports,
each with a maximum bidirectional bandwidth communication rate of up to 7.47 GB/sec.
Each MC990 X server chassis has ports that are brought out to external NUMAlink connectors on the
front of the enclosure. The single rack houses up to eight MC990 X server chassis (making up the MC990
X server), an RMC unit, and optional external storage.
Figure 1: MC990 X server chassis on page 6 shows an example of an MC990 X server chassis prior
to mounting in a rack.
The system requires a minimum of one rack with enough PDUs to support as many as eight MC990 X
server chassis, one RMC, and any optional equipment installed in the rack.
You can also add PCIe expansion cards or RAID and non-RAID disk storage to your server system.
1. System drive assembly
2. NUMAlink connectors (28)
Figure 1: MC990 X server chassis
System components
The Integrity MC990 X system includes the following major components:
6 HPE Integrity MC990 X Server overview
•42U rack—These racks are used for the MC990 X enclosures, RMC, and optional external storage in
the Integrity MC990 X system. Up to eight MC990 X enclosures can be installed in each 42U rack.
•Server chassis—The Integrity MC990 X system includes one base server chassis and can include
one or more expansion server chassis. Each 5U-high server chassis contains four power supplies, one
four-processor compute/memory board, and other optional riser enabled drives and boards for the
Integrity MC990 X system. The base server chassis also has a BaseIO riser not present in the
expansion server chassis. MC990 X base server chassis front components shows the MC990 X
server chassis front panel components.
1.USB ports (4)
2.ETH0
3.DVD drive
4.System drive assembly
5.RMC
6.MGMT
7.Serial port
8.VGA port
9.Optional 1.8-inch SSD drive bays
10. NUMAlink ports (28)
Figure 2: MC990 X base server chassis front components
HPE Integrity MC990 X Server overview7
1. PCIe card slots (16)
2. RMC port
3. MGMT port
4. Serial port
5. VGA port
6. NUMAlink ports (28)
Figure 3: MC990 X expansion server chassis front components
•Motherboard—Holds four processor sockets and eight memory risers. Each memory riser has up to
12 DIMMs, for a maximum of 96 DIMMs per motherboard. Each motherboard can be ordered with
risers that enable the base MC990 X server chassis to support up to four full-height x16 PCIe cards
and up to eight full-height x8 PCIe cards.
•Drives—Each MC990 X base server chassis has a drive tray that supports one optional slim-line
SATA DVD drive and four 2.5-inch hard disk or solid-state drives. An MC990 X expansion server
chassis does not require a drive assembly and can accommodate four additional PCIe cards.
•Internal PCIe enabled slots—The MC990 X enclosure and motherboard support the following types
of PCIe option boards:
NOTE: The x16 PCIe slots support cards with a maximum power consumption of 300 watts.
•NUMAlink Connectors —The external NUMAlink connectors are on the lower-front portion of each
MC990 X enclosure.
•BaseIO board—Optional I/O riser board, connected directly to the motherboard. Supports base
system I/O functions including one Gbit Ethernet connector (top), four USB ports, and bays for two
optional external 1.8-inch solid-state drives (SSDs).
Internally, the BaseIO board supports:
8HPE Integrity MC990 X Server overview
◦Four internal 3GB/s SATA ports (for the four 2.5-inch disk drives in the MC990 X server chassis)
◦Two internal 6GB/s SATA ports (for the two optional mini 1.8-inch SSDs)
◦One internal USB 2.0 port (for the internal DVD)
NOTE: Each Integrity MC990 X system (or SSI within a system) requires one BaseIO board. BaseIO
board front panel components shows the front components of the BaseIO board. The SSD drives
(bottom) are enclosed with a metal cover.
1. Ethernet port
2. USB ports (4)
3. Solid-state Drives (2)
Figure 4: BaseIO board front panel components
•RMC---This 1U-high rack management controller provides external LAN and USB connections into the
Integrity MC990 X system. It acts as a top layer of system control. An internal 24-port Ethernet switch
allows system control for up to multiple MC990 X enclosures in an expanded Integrity MC990 X
system.
HPE Integrity MC990 X Server overview9
1. Network ports (24)
2. WAN port
3. AUX port
4. CNSL port
5. RST button
6. PG (Power Good) LED indicator
7. HB (Heart Beat) LED indicator
Figure 5: RMC front panel connections
Unit numbering
Bays in the racks are numbered using standard units. A standard unit (U) is equal to 1.75 inches (4.445
cm). Because the chassis occupy multiple units, locations within a rack are identified by the bottom unit
(U) in which the chassis resides. For example, in a 42U rack, an MC990 X server chassis positioned in
U01 through U05 is identified as U01.
Rack numbering
Each rack is numbered with a three-digit number sequentially beginning with 001. A rack contains one or
more MC990 X server chassis, one RMC, optional mass storage enclosures, and other optional
components. In a single rack system, the rack number is always 001.
HPE Integrity MC990 X system features
The HPE Integrity MC990 X server is a modular system. The compute, memory, and PCIe components
are housed in the MC990 X chassis. Additional optional mass storage may be added to the system along
with additional MC990 X chassis.
You can add different types of PCIe board options to a server to achieve the desired system
configuration. You can easily configure systems around processing capability, I/O capability, memory size,
or storage capacity. Each air-cooled MC990 X chassis has redundant, hot-swap fans and redundant, hotswap power supplies.
Distributed shared memory (DSM)
In the Integrity MC990 X system, memory is physically distributed both within and among the MC990 X
server chassis (compute/memory/I/O); however, it is accessible to and shared by all NUMAlinked devices
within the SSI. This means all NUMAlinked components sharing a single Linux operating system operate
and share the memory fabric of the system. Memory latency is the amount of time required for a
processor to retrieve data from memory. Memory latency is lowest when a processor accesses local
memory. Note the following subtypes of memory within a system:
10HPE Integrity MC990 X Server overview
•If a processor accesses memory that it is connected to on an MC990 X server chassis motherboard,
the memory is referred to as the processor local memory. Figure 6: MC990 X server chassismemory riser block diagram on page 11 shows a conceptual block diagram of the motherboard
memory riser board pathways.
•If processors access memory located in another NUMAlinked MC990 X server chassis motherboard
within the system, the memory is referred to as remote memory.
•The total memory within the NUMAlinked Integrity MC990 X system is referred to as global memory.
Physical memory riser
Physical memory nodes are memory risers and each is made up of two board assemblies: memory riser
board and power board. Eight memory riser assemblies plug into each MC990 X server chassis
motherboard. The memory riser power board receives power directly from the motherboard. A maximum
of 12 DDR4 memory DIMMs are supported in each memory riser.
Memory controller
Figure 6: MC990 X server chassis memory riser block diagram
Distributed shared I/O
Like DSM, I/O devices are distributed within the MC990 X server chassis. Each BaseIO riser is accessible
by all compute nodes within the SSI through the NUMAlink interconnect fabric.
Rack management controller
Each Integrity MC990 X system has a rack management controller (RMC) located directly above or below
the MC990 X server chassis in a rack. The RMC supports powering up and down of the system
motherboards and environmental monitoring of all Integrity MC990 X system units within the SSI. In
addition, the RMC provides the top layer of system control for Integrity MC990 X system. Through the use
of an internal 24-port Ethernet switch, a single RMC can provide system control for multiple MC990 X
server chassis in an expanded Integrity MC990 X system.
One GigE port from each MC990 X server chassis motherboard connects to the RMC via Cat-5 cable.
HPE Integrity MC990 X Server overview11
Reliability, availability, and serviceability
HPE Integrity MC990 X system components have the following features to increase the reliability,
availability, and serviceability (RAS) of the systems.
•Power and cooling:
◦MC990 X server chassis power supplies are redundant and can be hot-swapped.
◦MC990 X server chassis have overcurrent protection at the motherboard and power supply level.
◦MC990 X server chassis fans are redundant and can be hot-swapped.
◦MC990 X server chassis fans run at multiple speeds. Speed increases automatically when
temperature increases or when a single fan fails.
•System monitoring:
◦System controllers monitor the internal power and temperature of the MC990 X server chassis
components, and can automatically shut down an enclosure to prevent overheating.
◦All main memory has Intel Single Device Data Correction to detect and correct 8 contiguous bits
failing in a memory device. Additionally, the main memory can detect and correct any two-bit errors
coming from two memory devices (8 bits or more apart).
◦All high speed links including Intel Quick Path Interconnect (QPI), Intel Scalable Memory
Interconnect (SMI), and PCIe have cyclic redundancy check (CRC) check and retry.
◦The NUMAlink interconnect network is protected by CRC.
◦Each MC990 X server chassis installed has status LEDs that indicate the server operational
condition; LEDs are viewable at the front of the unit.
•Power-on and boot:
◦Automatic testing occurs after you power on the system. These power-on self-tests or POSTs are
also referred to as power-on diagnostics or PODs.
◦Processors and memory are automatically disabled when a self-test failure occurs.
◦Boot times are minimized.
•Further RAS features:
◦Systems can report status inventory information, provide hardware logs of out-of-range conditions,
or perform recovery procedures through remote commands.
◦All system faults are logged in files.
◦Memory can be scrubbed using error checking code (ECC) when a single-bit error occurs.
12HPE Integrity MC990 X Server overview
Operational procedures
This chapter provides an overview on how to operate your new system in the following sections:
•
Precautions on page 13
•System control network on page 13
•Powering the system up and down on page 16
Precautions
Before operating your system, familiarize yourself with the safety information in the following sections:
ESD precaution on page 13
•
•Safety precautions on page 13
ESD precaution
CAUTION:
Observe all ESD precautions. Failure to do so can result in damage to the equipment.
HPE recommends wearing an approved wrist strap when you handle any ESD-sensitive device to
eliminate possible ESD damage to equipment. Connect the wrist strap cord directly to earth ground.
Safety precautions
WARNING: Before operating or servicing any part of this product, read the Safety information on
page 62.
WARNING: Keep fingers and conductive tools away from high-voltage areas. Failure to follow these
precautions will result in serious injury or death. The high-voltage areas of the system are indicated
with high-voltage warning labels.
CAUTION: Power off the system only after the system software has been shut down in an orderly
manner. If you power off the system before you halt the operating system, data may be corrupted.
System control network
All MC990 X server chassis use an RMC which communicates with the chassis board level BMCs within
each SSI. These components in concert are generically known as the system control network.
The Integrity MC990 X system control network provides control and monitoring functionality for each
motherboard, power supply, and fan assembly in each MC990 X server chassis in the system.
The RMC network provides the following functionality:
•Powering the entire system up and down.
•Powering individual MC990 X server chassis up and down.
•Monitoring the environmental state of the system, including voltage levels.
Operational procedures13
•Monitors and controls status LEDs on the enclosure.
•Supports entry of controller commands to monitor or change particular system functions within a
particular MC990 X server chassis. See the HPE Integrity MC990 X Server RMC Software User Guide
for a complete list of command line interface (CLI) commands.
•Provides access to the system OS console allowing you to run diagnostics and boot the system.
•Provides the ability to flash system BIOS.
Accessing the system control network
Access to the system control network is accomplished by the following methods:
•A LAN connection to the RJ-45 WAN port on the RMC, (see Figure 7: RMC front panel connections
on page 14).
•A USB-to-micro-USB serial connection to the “Console” port (see CNSL in Figure 7: RMC front panel
connections on page 14) on the RMC front panel example.
1. Network ports (24)
2. WAN port
3. AUX port
4. CNSL port
5. RST button
6. PG (Power Good) LED indicator
7. HB (Heart Beat) LED indicator
Figure 7: RMC front panel connections
Connecting to the system control network
The Ethernet connection is the preferred method of accessing the system console.
Administrators can perform one of the following options for connectivity:
14Operational procedures
•A portable system console can be directly connected to the RMC micro-USB connect port, (labeled
CNSL). See Figure 7: RMC front panel connections on page 14. This requires connecting from a
laptop or workstation that is physically located near the system.
•A LAN connection is used to communicate directly with the RMC, using the IPMI 2.x protocols. This
LAN connection must be made to the RJ-45 WAN port on the RMC. This connection can be used with
a local or remote IPMI-enabled console device.
Communicating with the system
The two primary ways to communicate with and administer the MC990 X system are through the RMC
interface command line interface (CLI) or through an IPMI 2.x LAN interface.
The command line interface
The Integrity MC990 X system CLI is accessible by logging directly into a RMC.
Log in to the RMC as root:
asylum$ ssh root@mc990x-rmc
root@mc990x-rmc's password:
MC990 X RMC, Rev. 1.1.xx [Bootloader 1.1.x]
RMC:r001i01c> help
NOTE: HPE recommends changing all default logins and passwords.
Once a connection to the RMC is established, system control commands can be entered. See ExampleCLI commands used on page 15 for some examples.
See Powering up and down from the command line interface on page 17 for additional specific
examples of using the CLI commands.
Example CLI commands used
The following is a list of some available CLI commands:
auth
authenticate SSN/APPWT change
bios
perform bios actions
bmc
access BMC shell
rmc
access RMC shell
config
show system configuration
console
access system consoles
help
list available commands
Operational procedures15
hel
access hardware error logs
hwcfg
access hardware configuration variable
leds
display system LED values
log
display system controller logs
power
access power control/status
Type <cmd> --help for help on individual commands.
Powering the system up and down
This section explains how to power up and power down individual units, or your entire Integrity MC990 X
system, as follows:
Preparing to power up on page 16
•
•Powering up and down from the command line interface on page 17
•Booting directly from an RMC on page 17
Using an RMC connection, you can power up and power down an individual MC990 X server chassis, or
the entire system.
Preparing to power up
To prepare to power up your system, follow these steps:
Procedure
1. Check to ensure that the power connector on the cable between the rack PDUs and the wall power-
plug receptacles are securely plugged in.
2. For each individual MC990 X server chassis that you want to power up, make sure that the power
cables are plugged into all the chassis power supplies correctly, see the example in Figure 8: MC990X server chassis power supply cable location on page 17. Setting the circuit breakers on the
PDUs to the (On) position will apply power to the individual MC990 X server chassis and will start the
RMC if it is plugged into the same PDU. Turn (Off) the PDU breaker switch on the PDU(s) that supply
power to the MC990 X server chassis or RMC power supplies if you want to remove all power from a
particular unit.
16Operational procedures
Figure 8: MC990 X server chassis power supply cable location
1. Enclosure fan assembly (4)2. HARP fan assembly
3. Enclosure power supply with power input
connector (4)
3. If you plan to power up an Integrity MC990 X system that includes optional mass storage enclosures,
make sure that the power switch on the rear of each PSU/cooling module (one or two per enclosure) is
in the (On) position.
4. Make sure that all PDU circuit breaker switches (see the examples in the following subsection) are
turned (On) to provide power to the server when the system is powered up.
Powering up and down from the command line interface
The Integrity MC990 X system CLI is accessible by logging into the RMC as “root”.
Commands issued at the CLI of a local console prompt typically only affect the local SSI or a part of the
system. Depending on the directory level you are logged in at, you may power up an entire SSI, a single
rack, or a single MC990 X server chassis. In CLI command console mode, you can obtain only limited
information about the overall system configuration. An RMC has information about all the MC990 X server
chassis in its rack or SSI. Each MC990 X server chassis has information about its internal motherboard
and options, and also (if other enclosures are attached via NUMAlink to the unit) information about those
MC990 X server chassis units.
Booting directly from an RMC
Use a USB-to-micro USB cable to administer your system locally from the RMC.
Connect the cable from your administrative laptop or other device directly to the port labeled CNSL on the
RMC. Note that the RMC will not (by default) require a password when you login via the CNSL port.
The console type and how these console types are connected to the Integrity MC990 X system is
determined by what console option is chosen. Establish either a serial connection and/or network/
Ethernet LAN connection to the RMC.
Operational procedures17
USB-connected console hardware requirements
The local USB-connected terminal should be set to the following functional modes:
•Baud rate of 115,200
•8 data bits
•One stop bit
•No parity
•No hardware flow control (RTS/CTS)
The physical console is located on the MC990 X server chassis that has the BaseIO board installed.
Figure 9: RMC Ethernet LAN (WAN port) location
1. Network ports (24)2. WAN
3. AUX port4. CNSL
5. RST button6. PG LED indicator
7. HB LED indicator
Remote LAN connection to the RMC
If you have an Integrity MC990 X system and wish to use a remote or local system to administer the
system via LAN, you can connect via Ethernet cable to the RMC node WAN port identified in Figure 9:RMC Ethernet LAN (WAN port) location on page 18.
•The terminal should be set to the operational modes described in the previous subsection.
•If you intend to use a LAN-connected administrative server to communicate with the RMC, the RMC
will either need to be assigned a DHCP IP address, or you will need to configure it with a static IP
address. See the following subsections for more information.
Establishing RMC IP hardware connections
For IP address configuration, there are two options: DHCP or static IP. The following subsections provide
information on the setup and use of both.
NOTE:
Both options require the use of the RMC micro-USB serial port, refer to Figure 7: RMC front panel
connections on page 14.
18Operational procedures
LAN Network (LAN RJ-45) connections to the RMC are always made via the WAN port.
For DHCP, you must determine the IP address that the RMC has been assigned; for a static IP, you must
also configure the RMC to use the desired static IP address.
To use the serial port connection, you must attach and properly configure a micro-USB interface cable to
the RMC CNSL port. Configure the serial port as described in USB-connected console hardwarerequirements on page 18.
When the serial port session is established, the console will show an RMC login, and the user can login to
the RMC as user "root". Note that there is not (by default) a password required to access the RMC via the
CNSL port.
Using DHCP to establish an IP address
To obtain and use a DHCP generated IP address, plug the RMC external RJ-45 network port (WAN) into
a network that provides IP addresses via DHCP; the RMC can then acquire an IP address.
To determine the IP address assigned to the RMC, you must first establish a connection to the RMC serial
LAN port (as indicated in the section
and run the command "ifconfig eth1". This will report the IP address that the RMC is configured to
use.
NOTE:
Running the RMC with DHCP is not recommended as the preferred option for Integrity MC990 X systems.
The nature of DHCP makes it difficult to determine the IP address of the RMC, and it is possible for that
IP address to change over time, depending on the DHCP configuration usage. The exception would be a
configuration where the system administrator is using DHCP to assign a "permanent" IP address to the
RMC.
USB-connected console hardware requirements on page 18),
To switch from a static IP back to DHCP, the configuration file /etc/sysconfig/ifcfg-eth1 on the
RMC must be modified. To edit this file, see additional instructions in the Using a static IP address on
page 19 section. The file must contain the following line to enable use of DHCP:
BOOTPROTO=dhcp
Using a static IP address
To configure the RMC to use a static IP address, the user/administrator must edit the configuration
file /etc/sysconfig/ifcfg-eth1 on the RMC. The user can use the vi command (i.e. "vi/etc/sysconfig/ifcfg-eth1") to modify the file.
The configuration file should be modified to contain these lines:
BOOTPROTO=static
IPADDR=<IP address to use>
NETMASK=<netmask>
GATEWAY=<network gateway IP address>
HOSTNAME=<hostname to use>
NOTE:
The "GATEWAY" and "HOSTNAME" lines are optional.
After modifying the file, save, and write it using the vi command ":w!", and then exit vi using ":q". Then
reboot the RMC using the reboot command. After reboot, it will be configured with the specified IP
address.
Operational procedures19
Power up the system using the RMC network connection
You can use a network connection to power on your Integrity MC990 X system as described in the
following steps:
Procedure
1. You can use the IP address of the RMC to perform an SSH login, as follows:
ssh root@<IP-ADDRESS>
The following example shows the RMC prompt:
MC990 X RMC, Rev. 1.1.xx [Bootloader 1.1.x]
RMC:r001i01c>
This refers to rack 1, RMC 1.
NOTE: HPE recommends changing all default logins and passwords.
2. Power up your Integrity MC990 X system using the power on command, as follows:
RMC:> power on
The system will take time to fully power up (depending on size and options). Larger systems take
longer to fully power up. Information on booting Linux from the shell prompt is included at the end of
Monitoring power up.
The following command options may be used with the RMC CLI:
Power up
Usage: power [-vcow] on|up [TARGET]—turns power on
-v, --verbose verbose output
-c, --clear clear EFI variables (system and partition targets only)
-o, --override override partition check
-w, --watch watch boot progress
Power down
Usage: [-vo] off |down [TARGET]—shuts power down
Reset system
Usage: power [-vchow] reset [TARGET]—resets the system power
Power status check
Usage: power [-vl0ud] status [TARGET]—checks power-on status.
To monitor the power-on sequence during boot, see
must be included.
Monitoring power up
Establish another connection to the RMC and use the uvcon command to open a system console and
monitor the system boot process. Use the following steps:
Monitoring power up, the -uvpower option
RMC:> uvcon
uvcon: attempting connection to localhost...
uvcon: connection to RMC (localhost) established.
uvcon: requesting baseio console access at r001i01b00...
uvcon: tty mode enabled, use ’CTRL-]’ ’q’ to exit
20Operational procedures
uvcon: console access established
uvcon: RMC <--> BASEIO connection active
************************************************
******* START OF CACHED CONSOLE OUTPUT *******
************************************************
** [20100512.143541] BMC r001i01b10: Cold Reset via NL broadcast reset
** [20100512.143541] BMC r001i01b07: Cold Reset via NL broadcast reset
** [20100512.143540] BMC r001i01b08: Cold Reset via NL broadcast reset
** [20100512.143540] BMC r001i01b12: Cold Reset via NL broadcast reset
** [20100512.143541] BMC r001i01b14: Cold Reset via NL broadcast reset
** [20100512.143541] BMC r001i01b04: Cold Reset via NL....
NOTE: Use CTRL+]+q to exit the console when needed.
Depending on the size of your system, it can take 5 to 10 minutes for the Integrity MC990 X system to
boot to the EFI shell. When the shell> prompt appears, enter fs0: as in the following example:
shell> fs0:
At the fs0: prompt, enter the Linux boot loader information, as follows:
fs0:> /efi/suse/elilo.efi
The ELILO Linux Boot loader is called and various configuration scripts are run and the SUSE Linux
Enterprise Server 12 Service Pack x installation program appears.
Power down the system
To power down the MC990 X system, use the power off command, as follows:
RMC:> power off
==== r001i01c (PRI) ====
You can also use the power status command, to check the power status of your system:
RMC:> power status
==== r001i01c (PRI) ====
on: 0, off: 16, unknown: 0, disabled: 0
Operational procedures21
System control
This chapter describes the general interaction and functions of the overall Integrity MC990 X system
control. System control parameters depend on the overall size and complexity of the Integrity MC990 X
system but will generally include the following three areas:
•The RMC (one per Integrity MC990 X system)
•The individual MC990 X server chassis-based board management controllers (BMC)—report to the
RMC
Levels of system control
The system control network configuration of your server will depend on the size of the system and control
options selected. Typically, an Ethernet LAN connection to the system controller network is used. This
Ethernet connection is made from a local or remote PC, server or workstation connected to the RMC.
The RMC is a separate stand-alone controller installed in the Integrity MC990 X system rack. The RMC
acts as a gateway and buffer between the Integrity MC990 X system control network and any other public
or private local area networks or systems used to communicate with the Integrity MC990 X system SSI.
IMPORTANT:
The Integrity MC990 X system control network is a private, closed network. It should not be
reconfigured in any way to change it from the standard Integrity MC990 X system factory
installation. It should not be directly connected to any other network. The Integrity MC990 X system
control network is not designed for, and does not accommodate additional network traffic, routing,
address naming (other than its own schema), or DCHP controls (other than its own configuration).
The Integrity MC990 X system control network also is not security hardened, nor is it tolerant of
heavy network traffic, and is vulnerable to Denial of Service attacks.
System management overview
An Ethernet connection directly from the RMC (Figure 10: RMC front panel on page 23) to a local
private or public LAN allows the system to be administered directly from a local or remote console. Note
that there is no direct inter-connected system controller function in any optional expansion or storage
modules.
The system control network is designed into all MC990 X server chassis motherboards. Controllers within
the system report and share status information via the RMC Ethernet interconnect cables. This maintains
controller configuration and topology information between all controllers in an SSI. Figure 11: RMCfunctionality on page 24 shows an example system control network using an optional and separate
(remote) workstation to monitor a single-rack Integrity MC990 X system. It is also possible to connect an
optional PC or server directly to the RMC via USB, see Figure 11: RMC functionality on page 24 for
an example diagram of RMC system management.
NOTE: External mass storage enclosures are not specifically monitored by the system controller network.
Most optional mass storage enclosures have their own internal microcontrollers for monitoring and
controlling all elements of the disk array. See the user guide for your mass storage option for more
information on this topic.
For information on software commands used for administering network connected Integrity MC990 X
systems using the RMC, see the HPE Integrity MC990 X Server RMC Software User Guide.
22 System control
Figure 10: RMC front panel
1. Network ports (24)2. WAN/LAN connector
3. AUX port4. CNSL micro-USB connector
5. RST button6. PG (Power Good) LED indicator
7. HB (Heart Beat) LED indicator
RMC overview
The RMC system for the Integrity MC990 X system manages power control and sequencing, provides
environmental control and monitoring, initiates system resets, stores identification and configuration
information, and provides console/diagnostic and scan interface.
The RMC provides the top layer of system control for the Integrity MC990 X system. This controller is a
stand-alone 1U high rack mount chassis.
NOTE: Physical placement of the RMC is above or below the MC990 X server chassis in a rack. The
RMC slides out the front of the rack only.
The RMC uses an internal 24-port Ethernet switch, which can provide system control for up to eight
MC990 X server chassis in an expanded system. The RMC accepts direction through IPMI 2.x-enabled
protocol software and supports powering-up and powering-down individual motherboards and
environmental monitoring of all units within the MC990 X server chassis.
The RMC sends operational requests to the BMC on each compute/memory motherboard installed. The
RMC and the BMC are active whenever power is applied to the system and are not dependent on the
Integrity MC990 X system having the operating system booted and operational.
The RMC in a system distributes its inquiries and information to all the MC990 X server chassis
motherboards within the SSI.
System control23
Figure 11: RMC functionality
BMC overview
Each system motherboard has a baseboard management controller. The BMC is a built-in specialized
microcontroller hardware component that monitors and reports on the functional health status of the
motherboard. The BMC provides a key functional element in the overall Intelligent Platform Management
Interface (IPMI) architecture.
The BMC acts as an interface to the higher levels of system control such as the RMC node and the
higher level control system used in the optional system management node. The BMC can report any onboard sensor information that it has regarding temperatures, power status, operating system condition
and other functional parameters that may be reported by the motherboard. When any of the preset limits
fall out of bounds, the information will be reported by the BMC and an administrator can take some
corrective action. This could entail a chassis shutdown, reset (NMI) or power cycling of the MC990 X
server chassis.
The individual motherboard BMCs do not have information on the status of other motherboards within the
SSI. This function is handled by the RMC and reported to an administrative console/server. Note that
motherboards equipped with an optional BaseIO riser board have a dedicated BMC Ethernet port.
System controller interaction
In all MC990 X server chassis, the RMC and BMC system controllers communicate with each other in the
following ways:
•System control commands and communications are passed between the administration node and the
RMC via LAN or a local USB interface cable.
•The RMC communicates directly with the BMC in each installed MC990 X server chassis via a
dedicated internal Gigabit Ethernet network.
•Each MC990 X server chassis has a dedicated RMC interface connector on the front of the system
chassis.
System controllers
Each Integrity MC990 X system must have at least one RMC installed. RMC functions on page 25
describe the basic features and functions of the BMC controllers.
NOTE:
For additional information on controller commands, see the HPE Integrity MC990 X Server RMC Software
User Guide.
24System control
RMC functions
The following list summarizes the control and monitoring functions that the RMC performs:
•Supports a Gigabit Ethernet interface
•Supports a limited (IPMI 2.x) interface for power control
•Controls powering up/down of the MC990 X server chassis in the system
•Supports Time Sync by providing synchronous Ethernet to each node BMC
•Provides a platform from which system data can be captured on failure
•Provides a platform from which various firmware updates can be initiated
•Provides inventory of system components as well various firmware revisions currently flashed
•Monitors and reports issues with the RMC related to power, fans, temperature, free memory and disk
space
•Provides RJ45 ports for connections to the MC990 X server chassis BMC
The following connectors and LEDs are also located on the front panel of the RMC:
•Stack connector—38 circuit ipass connector used to expand the system management network by
connecting to a second RMC
•WAN port—RJ45 port used to connect to the customer’s LAN or an in-rack administration node
•AUX port—RJ45 port currently is non-functional (reserved for future use)
•CNSL port—micro USB B port used for a local console/server connection
•RST switch—recessed push button switch used for reset of the RMC. The switch is accessed by
inserting a small screw driver or similar device through an opening in the front panel
•PG LED—green power good LED is illuminated when the correct power levels are present in the RMC
•HB LED—green heart beat LED flashes when the RMC is functioning normally
System control25
Using the Foundation Software
Foundation Software (FS) includes automatic boot-time optimization utilities, reliability features, and
technical support tools. Designed for high-performance computing, these tools help maximize system
performance and availability.
While many FS utilities and tools work in the background to optimize program performance, other tools
require configuration information from the system administrator. The FS components that this guide
addresses are:
•
Monitoring main memory health on page 26
•Monitoring system performance on page 27
•Enabling CPU frequency scaling on page 31
•Additional Foundation Software utilities on page 36
Monitoring main memory health
About main memory health monitoring
The MEMlog utility monitors the overall system health of each DIMM on your system. The MEMlog utility
is configured for your system when the Foundation Software is installed.
To verify that MEMlog utility is running, enter the following command:
# service memlog status
Retrieving main memory health information
HPE recommends that you check your computer system periodically to determine whether the MEMlog
utility has reported any hardware errors.
The MEMlog utility verifies and diagnoses problems with the DIMMs. The utility’s messages appear
in /var/log/messages.
Accessing MEMlog messages with commands on page 26 explains how to access information from
the MEMlog utility through the monitoring tools or by using commands.
Accessing MEMlog messages with commands
There are two ways to use commands to retrieve information about memory problems or memory health:
•Scan the system log for entries that contain the string MEMLOG. If problems arise with any of the
DIMMs on your system, the MEMlog utility writes a message to /var/log/messages. To retrieve
these messages, enter the following command:
# grep MEMLOG /var/log/messages
r1i0n0:Dec 9 07:29:45 r1i0n0 MEMLOG[4595]: Read ECC P1-DIMM1A Rank 0 DRAM U9 DQ4 Temp = 21C
r1i0n0:Dec 9 07:30:00 r1i0n0 MEMLOG[4595]: P1-DIMM1A has a failed DRAM and must be replaced soon.
Exposure to Uncorrected Error is high
r1i0n0:Dec 9 07:30:00 r1i0n0 MEMLOG[4595]: Read ECC P1-DIMM1A Rank 0 Bank 0 Row 0x0 Col 0x8 Temp = 21C
r1i0n0:Dec 9 07:30:00 r1i0n0 MEMLOG[4595]: Read ECC P1-DIMM1A Rank 0 DRAM U9 DQ4 Temp = 21C
r1i0n0:Dec 9 07:30:12 r1i0n0 MEMLOG[4595]: Read ECC P1-DIMM3A Rank 0 Temp = 22C
r1i0n0:Dec 9 07:30:12 r1i0n0 MEMLOG[4595]: Read ECC P1-DIMM3A Rank 0 DRAM U9 DQ4 Temp = 22C
r1i0n0:Dec 9 07:30:25 r1i0n0 MEMLOG[4595]: P1-DIMM3A has a failed DRAM and must be replaced soon.
26 Using the Foundation Software
Exposure to Uncorrected Error is high
r1i0n0:Dec 9 07:30:25 r1i0n0 MEMLOG[4595]: Read ECC P1-DIMM3A Rank 0 Bank 0 Row 0x0 Col 0x8 Temp = 22C
•Use the memlog command to retrieve a report. The report lists all the DIMMs in the system and
contains an error summary for each DIMM. To obtain this report, enter the following command:
rli0no: # memlogd —c
user config match for X9DRT-Dakota
found 2 sockets, highest socket number 1, deviceID Ivybridge, mem ctlrs/socket 1.
P1-DIMM1A Size 8192MB Width 4 Rank 2 Row 15 Col 11 Bank 8 Serial 405031E4 Part HMT31GR7EFR4C-RD 1867
Tue Dec 9 07:28:48 2014 Rank 0 Dram U9 Bank 0 Row 0x0 Col 0x8 multiaddress C DQ4 Temp = 21C hits 19
Tue Dec 9 07:31:31 2014 Rank 1 Dram U9B Bank 0 Row 0x0 Col 0x0 single DQ4 Temp = 21C hits 1
P1-DIMM2A Size 8192MB Width 4 Rank 2 Row 15 Col 11 Bank 8 Serial 409031CA Part HMT31GR7EFR4C-RD 1867
P1-DIMM3A Size 8192MB Width 4 Rank 2 Row 15 Col 11 Bank 8 Serial 405031DE Part HMT31GR7EFR4C-RD 1867
Tue Dec 9 07:30:12 2014 Rank 0 Dram U9 Bank 0 Row 0x0 Col 0x8 multiaddress C DQ4 Temp = 22C hits 2
P1-DIMM4A Size 8192MB Width 4 Rank 2 Row 15 Col 11 Bank 8 Serial 40C031C7 Part HMT31GR7EFR4C-RD 1867
P2-DIMM1A Size 8192MB Width 4 Rank 2 Row 15 Col 11 Bank 8 Serial 402031AA Part HMT31GR7EFR4C-RD 1867
P2-DIMM2A Size 8192MB Width 4 Rank 2 Row 15 Col 11 Bank 8 Serial 407031A8 Part HMT31GR7EFR4C-RD 1867
P2-DIMM3A Size 8192MB Width 4 Rank 2 Row 15 Col 11 Bank 8 Serial 407031E7 Part HMT31GR7EFR4C-RD 1867
P2-DIMM4A Size 8192MB Width 4 Rank 2 Row 15 Col 11 Bank 8 Serial 40C031E8 Part HMT31GR7EFR4C-RD 1867
The preceding example output includes 8 DIMMs. Note the following in this output:
◦Information about the first DIMM, P1-DIMM1A, is on the first line. The two lines that follow are the
DIMM repair tag, which shows that this DIMM has been encountering corrected errors.
◦The third DIMM, P1-DIMM3A, has also encountered corrected errors.
◦The last number on each line of inventory is 1867. This number is the channel speed that the
memory controller set at boot time for that DIMM.
Monitoring system performance
This section includes the following topics:
•About the system monitoring software on page 27
•hubstats command on page 27
•linkstat command on page 28
•gr_systat command on page 28
•nodeinfo command on page 28
•topology command on page 29
About the system monitoring software
You can use Linux utilities, FS utilities, and open source utilities to monitor system performance.
The Linux utilities include w(1), ps(1), top(1), vmstat(8), iostat(1), and sar(1). You can use
Linux system monitoring utilities on all MC990 X platforms, including Integrity MC990 X systems.
The FS utilities include hubstats, linkstat, nodeinfo, and topology. HPE supports these utilities
on all MC990 X platforms.
hubstats command
The hubstats command monitors NUMAlink traffic, directory cache operations, and global reference
unit (GRU) traffic statistics on MC990 X systems. It is useful as a performance monitoring tool and as a
tool to help you to diagnose and identify faulty hardware. The uvstats library supplies the hubstats
command with statistics from the MC990 X dashboard.
Using the Foundation Software27
linkstat command
The linkstat command monitors NUMAlink traffic on MC990 X systems. The linkstat command
returns information about packets and Mbytes sent/received on each NUMAlink in the system. It is useful
as a performance monitoring tool and as a tool to help you to diagnose and identify faulty hardware. The
uvstats library supplies the linkstat command with statistics from the MC990 X dashboard.
gr_systat command
The gr_systat command monitors CPU and memory activity on x86 systems. It’s graphical output
display includes information about CPU utilization, I/O wait times, IRQs, and memory utilization, both for
the system as a whole and for each node. The gr_systat command is a useful performance monitoring
tool.
nodeinfo command
nodeinfo is a tool for monitoring per-node NUMA memory statistics on MC990 X systems. The
nodeinfo tool reads /sys/devices/system/node/*/meminfo and /sys/devices/system/
node/*/numastat on the local system to gather NUMA memory statistics.
Sample memory statistics from the nodeinfo command are:
From an interactive nodeinfo session, enter h for a help statement. For example:
Display memory statistics by node.
q quit
+ Increase starting node number. Used only if more nodes than
will fit in the current window.
- Decrease starting node number. Used only if more nodes than
will fit in the current window.
b Start output with node 0.
e Show highest node number.
k show sizes in KB.
m show sizes in MB.
p show sizes in pages.
t Change refresh rate.
A Show/Hide memory policy stats.
H Show/Hide hugepage info.
L Show/Hide LRU Queue stats.
Field definitions:
hit - page was allocated on the preferred node
miss - preferred node was full. Allocation occurred on THIS node
by a process running on another node that was full
foreign - Preferred node was full. Had to allocate somewhere
28Using the Foundation Software
else.
interlv - allocation was for interleaved policy
local - page allocated on THIS node by a process running on THIS node
remote - page allocated on THIS node by a process running on ANOTHER node
(press any key to exit from help screen)
topology command
The topology command provides topology information about your system. Application programmers
can use the topology command to help optimize execution layout for their applications.
The topology command includes many options. For more information, enter topology --help on the
command line.
topology command showing the system summary
mc990x-sys:~ # topology
System type: MC990 X
System name: harp34-sys
Serial number: MC-00000034
Partition number: 0
2 Compute chassis
8 CPUs
2 Nodes
30.00 GB Memory Total
15.00 GB Max Memory on any Node
1 BASE I/O Riser
2 Network Controllers
2 Storage Controllers
2 USB Controllers
1 VGA GPU
topology command requests system summary and shows node and CPU information
mc990x-sys:~ # topology --summary --nodes --cpus
System type: MC990 X
System name: harp34-sys
Serial number: MC-00000034
Partition number: 0
2 Compute chassis
8 CPUs
2 Nodes
30.00 GB Memory Total
15.00 GB Max Memory on any Node
1 BASE I/O Riser
2 Network Controllers
2 Storage Controllers
2 USB Controllers
1 VGA GPU
CPU frequency scaling allows the operating system to scale the processor frequency automatically and
dynamically. HPE configures the CPU frequency scaling setting on all MC990 X computer systems before
the computer system leaves the factory. The default setting is assumed to be correct for most
implementations. The CPU frequency scaling setting lets your system take advantage of the Intel Turbo
Boost technology that is built into each processor.
The Intel Turbo Boost Technology allows processor cores to run faster than the base operating frequency
as long as they are operating below the limits set for power, current, and temperature. The CPU
frequency scaling setting also affects power consumption and enables you to manage power
consumption. For example, theoretically, you can cut power consumption if you clock the processors from
2 GHz down to 1 GHz.
CPU frequency scaling for Integrity MC990 X systems
The procedures that explain how to configure CPU frequency scaling on MC990 X systems depend on
whether your system includes the intel_pstate directory. If your MC990 X system includes the
intel_pstate directory, then CPU frequency scaling is enabled with the Intel P State driver. The path
to the intel_pstate directory on your system is: /sys/device/system/cpu/intel_pstate
After checking your MC990 X system for the presence of this directory, the following settings are available
to you:
•The CPU frequency settings for MC990 X systems that include an intel_pstate directory are:
Using the Foundation Software31
◦performance (default)
◦powersave
•The CPU frequency settings for MC990 X systems that do not include an intel_pstate directory
are:
◦conservative
◦ondemand (default)
◦performance. This setting directs the processors to run at or near their maximum speeds.
◦powersave. This setting slows down the processors and might be suitable for your site during
periods of low use.
◦userspace
Configuring the powersave setting on systems with the intel_pstate directory
By default, the CPU frequency setting on MC990 X servers that include the intel_pstate directory is
performance. During non-peak production times, you might want to configure the powersave setting.
To configure the powersave setting:
Procedure
1. Log in as root to the system you want to configure.
2. Use the cpupower command in one of the following formats:
a. To enable the powersave setting, enter the following command:
# cpupower frequency-set -g powersave
b. To re-enable the performance setting, which is the default, enter the following command:
# cpupower frequency-set -g performance
3. Enter the following command to retrieve the setting that is in effect:
#cpupower frequency-info
Verify that the setting you specified appears in the command output in the current policy field.
4. (Optional) Use a text editor to edit the /etc/init.d/after.local file and add the following line:
cpupower frequency-set -g powersave
The preceding line ensures that after each boot, the system sets the powersave setting.
Enabling CPU frequency scaling systems without the intel_pstate directory
The procedure in this topic explains how to enable or disable CPU frequency scaling on MC990 X
systems that do not include the intel_pstate directory.
To enable CPU frequency scaling:
32Using the Foundation Software
Procedure
1. Log in as root to the system you want to configure.
2. Use a text editor to open file /etc/sysconfig/x86config, and verify or change the system setting
from within this file.
This file contains the settings that enable or disable CPU frequency scaling.
To enable CPU frequency scaling, set
UV_DISABLE_CPU_FREQUENCY_SCALING=no.
To disable CPU frequency scaling, set
UV_DISABLE_CPU_FREQUENCY_SCALING=yes.
3. Enter the following command to propagate the new system setting:
#/usr/sbin/x86config
4. Enter one of the following commands to restart services:
a. On RHEL 6 platforms, enter the following:
# service cpuspeed restart
b. On RHEL 7 and SLES 12 platforms, enter the following:
# modprobe acpi_cpufreq
c. On SLES 11 platforms, enter the following:
# service haldaemon restart
5. Change the CPU frequency governor setting and configure turbo mode.
Proceed to
33
Changing the governor setting on systems without the intel_pstate directory on page
Changing the governor setting on systems without the intel_pstate directory
The default CPU frequency governor setting can inhibit system performance. Use the procedure in this
topic to change the governor setting.
Changing the governor setting is a prerequisite to configuring turbo mode. When you enable turbo mode,
you enable the CPU frequency to exceed its nominal level for short periods of time, depending on the
processor, temperature, current, power, and other factors. For general information about turbo mode, see
the following website:
The following procedure explains how to set the CPU frequency governor appropriately and points you to
the procedure that explains how to configure turbo mode
Procedure
1. Make sure that CPU frequency is enabled.
For information, see Enabling CPU frequency scaling systems without the intel_pstate directory
on page 32.
2. Decide which governor setting is suitable for your site.
Using the Foundation Software33
ondemand is the default setting. HPE recommends that you change this to a site-specific setting and
that you configure the governor to performance.
The possible power governor settings are:
Governor setting
Effect
ondemand
Dynamically switches between the available CPUs if at 95% of CPU load. Default.
HPE does not recommend this setting. Consider using the performance setting.
performance
Runs the CPUs at the maximum frequency.
HPE recommends this setting.
conservative
Dynamically switches between the available CPUs if at 75% of CPU load.
powersave
Runs the CPUs at the minimum frequency.
userspace
Runs the CPUs at user-specified frequencies.
3. Use one of the following platform-specific methods to change the setting:
•On RHEL 7 platforms, complete the following steps:
a. Enter the following command:
#cpupower frequency-set -g governor
For governor, specify the setting you chose in the previous step.
b. Enter the following command and verify that the governor setting you specified appears in the
cpupower command output in the current policy field:
# cpupower frequency-info
c. To ensure that the governor setting persists across reboots, enter the following command:
# systemctl enable cpupower
•On RHEL 6 platforms, complete the following steps:
a. Open file /etc/sysconfig/cpuspeed.
b. Search for the GOVERNOR= string.
c. Edit the setting, adding the governor setting you chose in the previous step.
d. Save and close the file.
e. Enter the following command:
34Using the Foundation Software
# service cpuspeed restart
f. To ensure that the governor setting persists across reboots, use a text editor to edit the /etc/
init.d/after.local file, add the following line, and then save and close the file:
cpupower freqency-set -g governor
•On SLES 12 platforms, complete the following steps:
a. Enter the following command:
#cpupower frequency-set -g governor
For governor, specify the setting you chose in the previous step.
b. Enter the following command and verify that the governor setting you specified appears in the
cpupower command output in the current policy field:
# cpupower frequency-info
NOTE: The remainder of the steps in this procedure for SLES 12 platforms ensure that governor
setting persists across reboots.
c. Use a text editor to create file /usr/lib/systemd/system/cpupower.service, populate
the file with the following content, and then save and close the file:
[Unit]
Description=Configure CPU power related settings
After=syslog.target
The preceding output shows the available frequencies, listed in order from the highest, 3301000 KHz,
to the lowest, 1200000 KHz.
On MC990 X systems, the second frequency listed is always the processor nominal frequency. This is
a 3.3 GHz processor, so 3300000 KHz is the nominal frequency.
You can also obtain the nominal frequency by entering the following command and examining the
information in the model name field:
#cat /proc/cpuinfo
3. Use the cpupower command to set the frequency to the nominal frequency of 3.3 GHz plus 1 MHz.
That is, specify a frequency of 3301 MHz. For example:
# cpupower frequency-set -u 3301MHz
Later, if you want to disable turbo mode, enter the following command to set the maximum frequency
back to the nominal frequency:
# cpupower frequency-set -u 3300MHz
Additional Foundation Software utilities
This section includes information about additional Foundation Software commands and utilities that
typically require no user involvement. HPE technical support staff members might guide you in the use of
these commands when troubleshooting or tuning.
36Using the Foundation Software
base-configuration
A collection of configuration scripts for MC990 X systems.
ha-stonith-plugins-uv
Provides STONITH agents to implement fencing on MC990 X systems through the RMC or CMC.
irqbalance
Controls interrupt request (IRQ) affinity on MC990 X systems. The daemon starts when a system
boots. If a device generates IRQs, irqbalance attempts to distribute the interrupts to the CPUs that
are on the same chassis (or node) upon which the interrupt originated.
By default, this utility starts every two minutes. To change that interval, set IRQBALANCE_SLEEPTIME
in /etc/sysconfig/irqbalance to the desired number of seconds and restart irqbalance or
reboot your system.
The base-configuration package automatically configures the irqbalance utility.
Using the Foundation Software37
Component replacement procedures
This chapter provides information about installing and removing PCIe cards, chassis fans and system
disk drives from your Integrity MC990 X system, as follows:
•
Maintenance precautions and procedures on page 38
•Removing the chassis top cover on page 39
•Adding or replacing PCIe or GPU cards on page 40
•Installing or replacing a drive on page 42
Maintenance precautions and procedures
This section describes how to open the system for maintenance and upgrade, protect the components
from static damage, and return the system to operation. The following topics are covered:
Preparing the system for maintenance or upgrade on page 38
•
•Returning the system to operation on page 39
WARNING:
To avoid problems that could void your warranty, your HPE or other approved service provider
should perform all the setup, addition, or replacement of parts, cabling, and service of your Integrity
MC990 X system, with the exception of the following items that you can perform yourself:
•Using your network access workstation to enter commands and perform system functions such
as powering up and powering down, as described in this guide.
•Installing, removing or replacing PCIe or GPU cards in the MC990 X server chassis
•Installing or replacing hard disk or SSD drives in the MC990 X server chassis
•Remove and replace an MC990 X server chassis fan assembly
•Remove and replace an MC990 X server chassis power supply
•Remove and replace an MC990 X server chassis BaseIO card
Be sure to observe all ESD precautions when removing or replacing these components. See ESD
precaution on page 13.
Preparing the system for maintenance or upgrade
To prepare the system for maintenance, follow these steps:
38 Component replacement procedures
Procedure
1. If you are logged on to the system, log out. Follow standard procedures for gracefully halting the
operating system.
2. Go to the section Powering the system up and down on page 16 if you are not familiar with power
down procedures.
3. After the system is powered off, locate the PDUs in the rack and turn off the circuit breaker switches
on each PDU.
Returning the system to operation
When you finish installing or removing components, return the system to operation as follows:
Procedure
1. Turn each of the PDU circuit breaker switches to the (On) position.
2. Power up the system. If you are not familiar with the proper power-up procedure, review the section
Powering the system up and down on page 16.
3. Verify that the LEDs on the system power supplies and system front components turn on and
illuminate green which indicates that the power-up procedure is proceeding properly.
If your system does not boot correctly, see Integrity MC990 X system Troubleshooting on page 48,
for troubleshooting procedures.
Removing the chassis top cover
IMPORTANT: The MC990 X server chassis cover should not be removed while the Integrity MC990
X system is powered up.
As shown in Figure 12: MC990 X server chassis cover removal on page 40, the MC990 X server
chassis top is a two-piece bifurcated front and rear chassis cover. The top cover does not need to be
removed for system disk replacement, power supply maintenance, or system fan remove/replace. Other
service actions require that you remove the front chassis cover.
To remove an MC990 X server chassis cover, use a T10 Torx screwdriver with the following instructions:
Procedure
1. Power down the chassis by turning off the PDUs providing power to the unit or by disconnecting all
power supply cords from the chassis rear (or both).
2. Remove the front panel (bezel) by grasping at either end and pulling it off.
3. In a multichassis system, you may need to remove the NUMAlink connector cables from the front of
the unit. Be sure they are labeled for proper reinstallation.
4. Ensure that all other rack-mounted enclosures are in place and pull the chassis out the front.
5. Using the Torx screwdriver, remove the three front retaining screws from the top cover and carefully
set them aside for reinstallation after completion of the procedure.
6. Grasp the front cover and slide it forward and upward from the chassis.
Component replacement procedures39
CAUTION: Always reinstall the chassis cover after you have accessed any internal components to
ensure proper airflow and cooling for the system. Failure to reinstall the cover may cause thermal
over-temperature conditions and automatic shut-down of the chassis.
Figure 12: MC990 X server chassis cover removal
Adding or replacing PCIe or GPU cards
WARNING:
Before installing, operating, or servicing any part of this product, read the Safety precautions on
page 13.
This section provides instructions for adding or replacing a PCIe or GPU-based PCIe card in your Integrity
MC990 X system. To maximize the operating efficiency of your cards, be sure to read all the introductory
matter before beginning the installation.
CAUTION:
To protect the PCIe cards from ESD damage, HPE recommends that you use a grounding wrist
strap while installing a PCIe card.
Installing cards in the MC990 X server chassis
Always follow the manufacturer’s instructions or restrictions for installing their card.
IMPORTANT: Addition of a new PCIe/GPU card requires a reboot to initiate recognition and
functionality. Removal (without replacement) of an existing PCIe card may cause system error
messages. When installing PCIe cards, ensure that the input current rating specified on the AC
input label is not exceeded.
The PCIe slots available in the MC990 X server chassis consist of the following:
NOTE: The x16 PCIe slots support cards with a maximum power consumption of 300 watts.
The procedure requires a T-10 Torx driver and Phillips-head screwdriver to complete. Before installing
the PCIe expansion cards, be sure to remove each respective slot cover and use its screw to secure
your expansion card in place. Shut down the operating system and remove all power from the chassis
before starting.
Procedure
1. Working from the front of the chassis, grasp the front panel on either side and pull it off the enclosure.
Use the Torx driver to remove the three screws that secure the front top cover. See the section
Removing the chassis top cover on page 39 for additional detail. Remove any NUMAlink cables and
label for replacement.
2. Push the two rail release latches in and slide the chassis forward. Remove the chassis cover as
detailed in Removing the chassis top cover on page 39.
3. Select an available slot based on the size of your PCIe card.
4. If replacing an existing PCIe card, disconnect any cables from the old card and remove its top
retaining screw. If using an empty PCIe slot, remove the metal slot cover from the selected slot and
retain its screw.
5. Fit the new PCIe card into the slot connector with the connector(s) extending out the front of the
chassis, making sure the card’s upper tab is flush with the chassis front, and then secure the board
with the screw that previously held the metal slot cover.
6. Reinstall the front top cover, push the chassis back into the rack until it latches and reconnect all
cables.
NOTE: Each NUMAlink cable should be labeled with source/destination information.
IMPORTANT: After installation of a new card, be sure to re-boot your system.
Component replacement procedures41
Figure 13: PCIe full-height x8 and x16 card slot locations
Installing or replacing a drive
The MC990 X server chassis holds up to four hard disk drives in a tray assembly at the front of the
chassis. The disk riser assembly occupies the riser card 1 position on the MC990 X server chassis
motherboard. It is located between the two side PCIe risers at the front of the chassis. The disk riser
assembly supports both 2.5-inch solid state (SSD) and 2.5-inch spinning disks, see Figure 14: MC990 Xfront drive array location on page 43. Note that the riser also supports one optional DVD that should
be installed or replaced by a trained service person. Instructions for installing/removing/replacing the DVD
drive are not in this document.
The drive-tray riser interface supports five devices. You can operate the DVD and hard drives at the same
time. Note that the tray assembly is not configured to support five 2.5-inch hard drives if the DVD drive
slot is unused. Figure 14: MC990 X front drive array location on page 43 calls out the location of the
2.5-inch system drive assembly on the front of the chassis as well as showing the location of the two 1.8-
inch SSD option drives.
NOTE:
An MC990 X server chassis expansion chassis does not include a standard drive/riser card assembly.
42Component replacement procedures
Figure 14: MC990 X front drive array location
1. USB port (4)2. Ethernet port
3. DVD drive4. System drive assembly
5. RMC port6. MGMT port
7. Serial port8. VGA port
9. 1.8–inch SSD drive bays10. NUMAlink ports (28)
Remove or replace a 2.5-inch hard drive
Each 2.5-inch hard disk drive in the MC990 X server chassis drive tray is secured in a drive sled that
slides in and out of the drive tray assembly and locks in place.
Use the following steps and illustrations to add or replace a hard disk drive in the MC990 X server
chassis:
Procedure
1. Shut down the Integrity MC990 X system operating system.
2. To remove power from the chassis, unplug all the MC990 X server chassis power supply cords.
3. Grasp the perforated front chassis cover at either end and pull it off the front of the unit.
4. Locate the drive you need to remove and push in its top release latch, see Figure 15: Hard drive
remove/replace on page 44 for an example.
5. Pull the drive retention handle outward to completely unlock the drive-sled assembly.
6. Pull the drive-sled assembly straight out and lift it away from the chassis.
7. Select the tray location for the new hard disk drive. If the new drive is not equipped with an MC990 X
server chassis style mounting bracket (sled), remove the old drive’s sled and install the hardware on
Component replacement procedures43
the replacement drive. Check with your support provider if you do not have the appropriate sled
hardware to install additional drives in the tray.
8. If you have disconnected power, reconnect all the chassis power supplies and restart the system. Use
the instructions in Powering the system up and down on page 16 if you are unfamiliar with the
power-up procedure.
Figure 15: Hard drive remove/replace
Remove or replace a 1.8-inch SSD option drive
The BaseIO card supports two optional “mini” 1.8-inch SATA solid-state-drives (SSDs) which are
accessible from the front of the chassis. The two SSD slots are located directly below the BaseIO board’s
USB ports. The two SSDs connect internally via a cable to two 6GB/s SATA ports. The SSDs are
accessible from the front of the chassis. A metal cover used to protect the SSDs is held in place by a
single T10 Torx screw. An SSD may be hot-swapped only if it is part of a RAID drive-pair. In this case you
may leave the operating system running and the MC990 X server chassis in the rack.
Use the following information to remove or replace a 1.8-inch SSD in the BaseIO:
Procedure
1. Access the front of the rack and remove the MC990 X server chassis front panel (bezel) by grasping at
either end and pulling it off.
2. Use a T10 Torx driver to unscrew and remove the outer metal cover that protects the SSDs.
3. Extract a drive by grasping the front of the drive and pulling straight out.
44Component replacement procedures
4. Insert a new drive by sliding the SSD into the empty slot until it fully engages the connector.
5. Replace the BaseIO board SSD cover and secure it with the T10 Torx screw.
Figure 16: Optional 1.8-inch solid state drives
1. Ethernet port
2. USB ports (4)
3. SSD drives (2)
Replacing an MC990 X server chassis power supply
To remove and replace power supplies in an MC990 X server chassis, you do not need any tools. Under
most circumstances, a single power supply can be replaced without shutting down the enclosure or the
complete system. In the case of a fully configured MC990 X server chassis, this may not be possible.
CAUTION: The body of the power supply may be hot; allow time for cooling and handle with care.
Use the following steps to replace a power supply in the MC990 X server chassis:
Component replacement procedures45
Procedure
1. Open the rear door of the rack and locate the power supply that needs replacement. The powersupplies are located along the bottom section of each MC990 X server chassis, see Figure 17:
MC990 X server chassis power supply and fan locations on page 46 for an example.
2. Disengage the power-cord retention clip and disconnect the power cord from the power supply that
needs replacement.
3. Press the retention latch of the power supply toward the power connector to release the supply from
the chassis.
4. Using the power supply handle, pull the power supply straight out until it is partly out of the chassis.
Use one hand to support the bottom of the supply as you fully extract it from the enclosure. Each
supply is 10.4-inches (26.4 cm) long and weighs 2.65 lb (1.2 kg).
5. Align the rear of the replacement power supply with the chassis opening.
6. Slide the power supply into the chassis until the retention latch engages; you should hear an audible
click.
7. Reconnect the power cord to the supply and engage the retention clip.
Figure 17: MC990 X server chassis power supply and fan locations
1. Enclosure fan assembly (4)2. HARP fan assembly
3. Enclosure power supplies (4)
Replacing an MC990 X server chassis fan assembly
Chassis cooling for each MC990 X server chassis is provided by four rear-mounted fan assemblies (as
seen in Figure 17: MC990 X server chassis power supply and fan locations on page 46). Each
chassis cooling fan unit is made up of two stacked 80mm fans.
If one fan assembly fails, the remaining fans will ramp up to full speed and the overheat/fan fail/info LED
on the front control panel will illuminate (the system can continue to run with a single failed fan assembly).
Each power supply in the system is cooled by an individual internal cooling fan.
46Component replacement procedures
You will need to access the rack from the back to remove and replace a fan assembly.
Under most circumstances a fan can be replaced while the system is operating. You will not need any
tools to complete the replacement procedure.
Use the following steps to replace an MC990 X server chassis fan assembly:
Procedure
1. Open the rack rear door and identify the fan assembly that has failed.
2. Grasp the handle of the failed cooling fan assembly and pull the unit straight out. See Figure 18:
MC990 X server chassis rear fan assembly on page 47 for an example of the chassis fan
assembly.
3. Slide a new fan assembly completely into the open slot until the fan-interconnect engages and the new
unit is flush with the rear of the chassis.
4. Confirm that the new fan assembly is operational and close the rack rear door.
Figure 18: MC990 X server chassis rear fan assembly
Component replacement procedures47
Integrity MC990 X system Troubleshooting
This chapter provides the following sections to help you troubleshoot your system:
•
Troubleshooting chart on page 48
•LED status indicators on page 48
Troubleshooting chart
Cause
Table 1: Problems and recommended actions
Problem DescriptionRecommended Action
The system will not power on.Ensure that the power cords of the MC990 X server
chassis are seated properly in all power receptacles.
Ensure that the PDU circuit breakers are on and properly
connected to the wall source.
If the power cords are plugged in and the circuit breaker
is on, contact your support provider.
An individual chassis will not power on.Ensure all the power cables of the chassis are plugged
in.
Confirm the PDU(s) supporting the chassis are on.
The system will not boot the operating
system.
An amber LED illuminates on a motherboard. See MC990 X server chassis power supply LED
The amber (yellow) status LED of a power
supply is lit or the LED is not lit at all. See
MC990 X server chassis power supply
LED states.
The PWR LED of a populated PCIe slot is
not illuminated.
The Fault LED of a populated PCIe slot is
illuminated (on).
The amber or red LED of a disk drive is on.Replace the disk drive.
Contact your authorized support organization.
states for a description of the status message.
Ensure the power cable to the supply is firmly connected
at both ends and that the PDU is turned to on. Check and
confirm the supply is fully plugged into it’s slot. If the
green LED does not light, contact your support engineer.
Reseat the PCIe card.
Reseat the card. If the fault LED remains on, replace the
card.
LED status indicators
There are a number of LEDs on the MC990 X server chassis that can help you detect, identify and
potentially correct functional interruptions in the system. The following subsections describe these LEDs
and ways to use them to understand potential problem areas.
48 Integrity MC990 X system Troubleshooting
Power supply LEDs
Each power supply installed in an MC990 X server chassis has a bicolor status LED. The LED will either
light green or amber (yellow), or flash green or yellow to indicate the status of the individual supply.
Table 2: MC990 X server chassis power supply LED states
Power supply statusGreen LEDAmber LED
No AC power to the supplyOffOff
Power supply has failedOffOn
Power supply problem warningOffFlashing
AC available to supply (standby) but chassis
system power is off
Power supply on (system is on)OnOff
The system RMC unit uses two power supplies and two cables. Each supply in the RMC uses a blue LED
to indicate normal function and a red LED for errors.
Table 3: RMC power supply LED states
Power supply statusBlue LEDRed LED
No AC power to either supplyOffOff
A power supply has failedOffOn
No AC power to one supplyOffFlashing
Power supply on (system is on)OnOff
System motherboard status LEDs
Each MC990 X server chassis motherboard installed in a chassis has a total of 23 LED indicators visible
from the front of the unit. The LEDs are located behind the perforated front-panel sheet metal and may
not be clearly visible except when lit.
FlashingOff
Starting from the left side of the motherboard, there are:
•A single red over-current LED
•A 4-stack of green 12V power good LEDs
•A 4-stack of green CPU (0-3) power good LEDs
•One green 3.3V auxiliary power LED and one 3.3V power good LED
•One green 5V auxiliary power LED and one green 5V power good LED
•12V auxiliary power and 12V main power green LEDs
•Power supply OK and system power OK green LEDs
Integrity MC990 X system Troubleshooting49
•An amber sleep state and platform reset LEDs
•Power good for HARP ASIC 0 and 1 green LEDs
On the far right side of the board are:
•Unit identifier blue/white LED
•A green BMC heartbeat LED
If the system motherboard is powered on and there is no LED activity showing on the unit, it must be
replaced. Figure 19: System motherboard status LED locations and functions on page 50 shows
the locations of the motherboard LEDs.
1. 12V overcurrent
2. Unit ID
3. BMC heartbeat
4. Top to bottom: Sleep A state, Platform Reset, Power Good HARP 0, Power Good HARP 1
5. Top to bottom: Power Good P12V Aux, Power Good P12V E, Power Supply Power OK, System Power
OK
6. Top to bottom: Power Good P3V3 Aux, Power Good P3V3, Power Good P5V Aux, Power Good P5V
7. Top to bottom: Power Good CPU 0, Power Good CPU 1, Power Good CPU 2, Power Good CPU 3
8. Top to bottom: Power Good P12V A, Power Good P12V B, Power Good P12V C, Power Good P12V D
Figure 19: System motherboard status LED locations and functions
50Integrity MC990 X system Troubleshooting
Technical specifications and pinouts
This appendix contains technical specification information about your system, as follows:
•
Integrity MC990 X system specifications on page 51
•Integrity MC990 X system physical specifications on page 51
•Integrity MC990 X system environmental specifications on page 52
•Integrity MC990 X system electrical specifications on page 53
•I/O port specifications on page 54
Integrity MC990 X system specifications
Integrity MC990 X system configuration ranges summarizes the Integrity MC990 X system
configuration ranges. While each MC990 X server chassis motherboard houses four processor sockets,
each processor holds multiple processor cores. The number of cores supported will change based on
customer selection and processor availability.
Table 4: Integrity MC990 X system configuration ranges
CategoryMinimumMaximum
Processors per server chassis4 processors (1 motherboard)
Cores per Processor424
Server chassis1 per system8 per system
Motherboards1 per server1 per server
Memory risers on motherboard8 per motherboard8 per motherboard
Motherboard DIMM capacity32 DIMMs per board96 DIMMs per board
Memory capacity per DIMM8GB64 GB
RMC units1 per system1 per system
Number of BaseIO riser boardsOne per SSIOne per SSI
1
The quad-socket MC990 X server chassis motherboard supports four processors using multiprocessor cores.
1
4 processors
Integrity MC990 X system physical specifications
MC990 X server chassis and 42U rack physical specifications shows the physical specifications of
the rack-mounted Integrity MC990 X system.
Technical specifications and pinouts51
Table 5: MC990 X server chassis and 42U rack physical specifications
FeatureSpecification
Dimensions for single MC990 X server chassisHeight: 5U 8.64 inches (22 cm)
Width: 17.5 inches (44.5 cm)
Depth: 31.8 inches (80.8 cm)
Weight of single MC990 X server chassis (fully
configured)
Dimensions for a single 24-inch wide 42U rack,
including doors and side panels
Shipping dimensions (single rack)Height: 88.8 in. (225.8 cm)
Single rack shipping weight (max)2,070 lb. (939 kg) air cooled (approximate)
Single rack system weight installed (max)1,579 lb. (716 kg) air cooled (approximate)
42U rack access requirements:Front: 48 in. (121.9 cm)
136 lb. (62 kg)
Height: 78.75 in. (200 cm)
Width: 28 in. (70.1 cm)
Depth: 45.5 in. (115.6 cm)
Width: 44 in. (111.8 cm)
Depth: 62.75 in. (159.4 cm)
*Empty rack weight is approximately 391 lb. (177
kg)
Rear: 48 in. (121.9 cm)
Top: 18 in. (45.7 cm)
Integrity MC990 X system environmental specifications
Environmental specifications lists the environmental specifications of the Integrity MC990 X system.
Table 6: Environmental specifications
FeatureSpecification
Temperature tolerance (operating)+5 °C (41 °F) to +35 °C (95 °F) (up to 1500 m / 5000 ft.)
+5 °C (41 °F) to +30 °C (86 °F) (1500 m to 3000 m /5000 ft. to
10,000 ft.)
De-rate max ambient temperature by 1.8 °F (1 °C) per 1000 ft.
(305 m) of altitude above 5000 ft. (1525 m)
Temperature tolerance (nonoperating)
52Technical specifications and pinouts
-40 °C (-40 °F) to +60 °C (140 °F)
Table Continued
FeatureSpecification
Relative humidity20% to 80% operating (no condensation)
8% to 80% non-operating (no condensation)
Heat dissipation to airApproximately 17.74 kBTU/hr (1.48 tons)
Cooling requirementAmbient air cooling
Single chassis air-flow: intake (front),
exhaust (rear)
Maximum altitude10,000 ft. (3,049 m) operating
Acoustic sound pressureApproximately 77 dBA (at rear of rack)
650 CFM Max (1104 m3/hr)
475 CFM typical (407 m3/hr)
40,000 ft. (12,195 m) non-operating
Integrity MC990 X system electrical specifications
MC990 X system electrical specifications shows the power specifications for the MC990 X system.
Table 7: MC990 X system electrical specifications
FeatureSpecification
Server chassis power supply (4 per chassis)12-Volt, 1600 Watt (Platinum) [200-240 VAC]
Server chassis power cordsFour 8-ft (2.4 m) drop cables
Server chassis power requirements
Voltage200-240V (180-264 VAC min/max)
Frequency50-60 Hz (47-63 Hz min/max)
Power (maximum per MC990 X server chassis)5.33 kVA (5.22kW) per chassis
Hold-up time10 ms
Single-phase PDU power requirements
Voltage180-264 VAC
Frequency50-60 Hz
Three-phase PDU power requirements
Voltage180-264 VAC (North America)
312-457 VAC (International)
Table Continued
Technical specifications and pinouts53
FeatureSpecification
Frequency50-60 Hz
Total harmonic distortionLess than 10% at full load
The Integrity MC990 X system RMC power and technical specifications are provided in RMC
specifications.
Table 8: RMC specifications
FeatureSpecification
Height1.72 inches (44 mm)
Width17.2 inches (43.7 cm)
Depth29.84 inches (75.8 cm)
Weight20 lb. (9.1 kg)
RMC power supplyTwo per RMC
RMC power cordsTwo 8-ft (2.4 m) drop cables
RMC power requirements
Voltage200-240V (180-264 VAC min/max)
Frequency50-60 Hz (47-63 Hz min/max)
Power(50W) per supply
Hold-up time20 ms
Air flow (front to back)Maximum = 35 CFM (60 m3) per hour
Acoustical noiseApproximately 68 dBA
Heat dissipation to airApproximately 171 BTU (0.02 tons) per hour
I/O port specifications
This section contains specifications and port pinout information for the base I/O ports of your system, as
follows:
•Motherboard VGA port information on page 55
•Ethernet port on page 56
•Serial port on page 57
•USB port on page 57
54Technical specifications and pinouts
Motherboard VGA port information
The 15-pin VGA port on the motherboard (see VGA port connector) has the following features:
•Server-class 2D hardware acceleration support with integrated 24-bit RAMDAC
•Display resolution up to 1600 x 1200 @ 60Hz
•Up to 128 Mbytes DDRII memory interface support
•A USB keyboard/mouse can be supported by the BaseIO blade connectors
The motherboard VGA interface (see VGA port pin functions) can be used for all basic interaction with
your Integrity MC990 X system. Note that it does not provide a direct interconnect to the system RMC.
Figure 20: VGA port connector
Table 9: VGA port pin functions
PinFunction
1Red
2Green
3Blue
4N/C
5Ground
6Ground
7Ground
8Ground
9Ground
10Ground
11N/C
12DDCDAT
13HSYNC
Table Continued
Technical specifications and pinouts55
PinFunction
14VSYNC
15DDCCLK
Ethernet port
The system auto-selects the Ethernet port speed and type (duplex vs. half-duplex) when the server is
booted, based on what it is connected to. Figure 21: Ethernet port connector on page 56 shows the
Ethernet port.
Figure 21: Ethernet port connector
Ethernet port pinouts shows the cable pinout assignments for the Ethernet port operating in 10/100-
Base-T mode and also operating in 1000Base-T mode.
The system motherboards have 9-pin serial interface connectors. These ports provide serial access to the
individual chassis and are capable of transferring data at rates as high as 230 kbps. Other features of the
ports include the following:
•Programmable data, parity, and stop bits
•Programmable baud rate and modem control
Figure 22: Serial port connector on page 57 shows a serial port.
Figure 22: Serial port connector
Serial port pinout shows pinout assignments for the 9-pin male DB-9 connector.
Table 11: Serial port pinout
PinAssignmentDescription
1DCDData carrier detect
2RXDReceive data
3TXDTransmit data
4DTRData terminal ready
5GNDSignal ground
6DSRData set ready
7RTSRequest to send
8CTSClear to send
9RIRing indicator
USB port
The USB type A connector (Figure 23: USB type A port connector on page 58) shows provided on
the BaseI/O that supports general USB applications and optional keyboard and mouse configurations.
Pin assignments for USB type A connector lists the pin assignments for the USB type A connector.
Technical specifications and pinouts57
Figure 23: USB type A port connector
Table 12: Pin assignments for USB type A connector
PinSignalWire color
1VCCRed
2-DataWhite
3+DataGreen
4GroundBlack
58Technical specifications and pinouts
System technical information
System architecture
The Integrity MC990 X system is based on a cache-coherent non-uniform memory access architecture.
Because it is modular, the Integrity MC990 X system architecture combines the advantages of lower entry
cost with the ability to scale processors, memory, and I/O independently.
The system interconnect architecture for the Integrity MC990 X system is a seventh-generation NUMAlink
SMP architecture known as NUMAlink 7. In the NUMAlink 7 architecture, all processors and memory can
be tied together into a single logical system. This combination of processors, memory, and internal
switches constitute the interconnect fabric called NUMAlink within each Integrity MC990 X system SSI.
The basic expansion building block for the NUMAlink interconnect is the MC990 X server chassis. Each
chassis uses two HARP ASICs and four Intel processors with multiple cores and on-chip secondary
caches. Each HARP ASIC supports two internal communication hubs and each of the chassis Intel
processors are connected to a hub via one 8.0GT/s quick path interconnect channel.
The HARP ASIC is the heart of the MC990 X server chassis technology. This specialized ASIC acts as a
crossbar between the processors and remote DRAM memory. The ASIC enables any processor to
access the memory of all processors in the SSI.
functional block diagram on page 60 shows a functional block diagram of the MC990 X server
chassis.
Figure 24: MC990 X server chassis motherboard
System technical information59
Figure 24: MC990 X server chassis motherboard functional block diagram
ccNUMA architecture
As the name implies, the cache-coherent non-uniform memory access (ccNUMA) architecture has two
parts, cache coherency and nonuniform memory access, which are discussed in the sections that follow.
Cache coherency
The Integrity MC990 X system server uses caches to reduce memory latency. Although data exists in
local or remote memory, copies of the data can exist in various processor caches throughout the system.
Cache coherency keeps the cached copies consistent.
To keep the copies consistent, the ccNUMA architecture uses directory-based coherence protocol. In
directory-based coherence protocol, each block of memory (128 bytes) has an entry in a table that is
referred to as a directory. Like the blocks of memory that they represent, the directories are distributed
among the compute/memory blade nodes. A block of memory is also referred to as a cache line.
Each directory entry indicates the state of the memory block that it represents. For example, when the
block is not cached, it is in an unowned state. When only one processor has a copy of the memory block,
it is in an exclusive state. And when more than one processor has a copy of the block, it is in a shared
state; a bit vector indicates which caches may contain a copy.
When a processor modifies a block of data, the processors that have the same block of data in their
caches must be notified of the modification. The Integrity MC990 X system uses an invalidation method to
60System technical information
maintain cache coherence. The invalidation method purges all unmodified copies of the block of data, and
the processor that wants to modify the block receives exclusive ownership of the block.
Non-uniform memory access (NUMA)
In DSM systems, memory is physically located at various distances from the processors. As a result,
memory access times (latencies) are different or non-uniform. For example, it takes less time for a
processor blade to reference its locally installed memory than to reference remote memory.
System technical information61
Safety and regulatory information
This appendix provides safety information and regulatory specifications for your system.
For additional important safety, environmental, and regulatory information, see Safety and ComplianceInformation for Server, Storage, Power, Networking, and Rack Products, available at
1.Follow all warnings and instructions marked on the product and noted in the documentation included
with this product.
2.Unplug this product before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp
cloth for cleaning. Do not use this product near water.
3.Do not place this product or components of this product on an unstable cart, stand, or table. The
product may fall, causing serious damage to the product.
4.Slots and openings in the system are provided for ventilation. To ensure reliable operation of the
product and to protect it from overheating, these openings must not be blocked or covered. This
product should never be placed near or over a radiator or heat register, or in a built-in installation,
unless proper ventilation is provided.
http://
5.This product should be operated from the type of power indicated on the marking label. If you are not
sure of the type of power available, consult your dealer or local power company.
6.Do not allow anything to rest on the power cord. Do not locate this product where people will walk on
the cord.
7.Never push objects of any kind into this product through cabinet slots as they may touch dangerous
voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any
kind on the product.
8.Do not attempt to service this product yourself except as noted in this guide. Opening or removing
covers of node and switch internal components may expose you to dangerous voltage points or other
risks. Refer all servicing to qualified service personnel.
9.Unplug this product from the wall outlet and refer servicing to qualified service personnel under the
following conditions:
•When the power cord or plug is damaged or frayed.
•If liquid has been spilled into the product.
•If the product has been exposed to rain or water.
•If the product does not operate normally when the operating instructions are followed. Adjust only
those controls that are covered by the operating instructions. Improper adjustment of other
controls may result in damage.
•If the product has been dropped or the cabinet has been damaged.
•If the product exhibits a distinct change in performance, indicating a need for service.
62 Safety and regulatory information
CAUTION:
Slide/rail mounted equipment is not to be used as a shelf or a workspace.
Figure 25: Slide rail equipment warning
10. If a lithium battery is a soldered part, only qualified service personnel should replace this lithium
battery. For other types, replace it only with the same type or an equivalent type recommended by
the battery manufacturer, or the battery could explode. Discard used batteries according to the
manufacturer’s instructions.
11. Use only the proper type of power supply cord set (provided with the system) for this unit.
12. Do not attempt to move the system alone. Moving a rack requires at least two people.
13. Keep all system cables neatly organized in the cable management system. Loose cables are a
tripping hazard that cause injury or damage the system.
Regulatory information
For important safety, environmental, and regulatory information, see Safety and Compliance Information
for Server, Storage, Power, Networking, and Rack Products, available at http://www.hp.com/support/
Safety-Compliance-EnterpriseProducts.
This product contains a laser that is classified as a Class 1 laser device.
Regulatory Model Numbers
The MC990 X server chassis Regulatory Model Number is: RSVLA-RE01
The RMC chassis Regulatory Model Number is: RSVLA-RE02
Each Regulatory Model Number is marked on the regulatory label which is affixed to each chassis during
the production process. The regulatory labels are placed as near as possible to the power supply AC
inputs.
To access restricted support documentation for HPE MC990 X Server:
1. Sign in to Hewlett Packard Enterprise Support Center.
https://support.hpe.com/hpesc/public/home/signin
2. Go to the restricted MC990 X Server page.
www.hpe.com/support/mc990x-docs-restricted
General websites
Hewlett Packard Enterprise Information Library
www.hpe.com/info/EIL
Single Point of Connectivity Knowledge (SPOCK) Storage compatibility matrix
www.hpe.com/storage/spock
Storage white papers and analyst reports
www.hpe.com/storage/whitepapers
For additional websites, see Support and other resources.
64 Websites
Support and other resources
Accessing Hewlett Packard Enterprise Support
•For live assistance, go to the Contact Hewlett Packard Enterprise Worldwide website:
http://www.hpe.com/assistance
•To access documentation and support services, go to the Hewlett Packard Enterprise Support Center
website:
http://www.hpe.com/support/hpesc
Information to collect
•Technical support registration number (if applicable)
•Product name, model or version, and serial number
•Operating system name and version
•Firmware version
•Error messages
•Product-specific reports and logs
•Add-on products or components
•Third-party products or components
Accessing updates
•Some software products provide a mechanism for accessing software updates through the product
interface. Review your product documentation to identify the recommended software update method.
•To download product updates:
Hewlett Packard Enterprise Support Center
www.hpe.com/support/hpesc
Hewlett Packard Enterprise Support Center: Software downloads
www.hpe.com/support/downloads
Software Depot
www.hpe.com/support/softwaredepot
•To subscribe to eNewsletters and alerts:
www.hpe.com/support/e-updates
•To view and update your entitlements, and to link your contracts and warranties with your profile, go to
the Hewlett Packard Enterprise Support Center More Information on Access to Support Materials
page:
www.hpe.com/support/AccessToSupportMaterials
Support and other resources65
IMPORTANT: Access to some updates might require product entitlement when accessed through
the Hewlett Packard Enterprise Support Center. You must have an HPE Passport set up with
relevant entitlements.
Customer self repair
Hewlett Packard Enterprise customer self repair (CSR) programs allow you to repair your product. If a
CSR part needs to be replaced, it will be shipped directly to you so that you can install it at your
convenience. Some parts do not qualify for CSR. Your Hewlett Packard Enterprise authorized service
provider will determine whether a repair can be accomplished by CSR.
For more information about CSR, contact your local service provider or go to the CSR website:
http://www.hpe.com/support/selfrepair
Remote support
Remote support is available with supported devices as part of your warranty or contractual support
agreement. It provides intelligent event diagnosis, and automatic, secure submission of hardware event
notifications to Hewlett Packard Enterprise, which will initiate a fast and accurate resolution based on your
product's service level. Hewlett Packard Enterprise strongly recommends that you register your device for
remote support.
If your product includes additional remote support details, use search to locate that information.
Remote support and Proactive Care information
HPE SGI Remote Support Release Notes
www.hpe.com/support/axeda-release-notes
HPE Proactive Care services
www.hpe.com/services/proactivecare
HPE Proactive Care service: Supported products list
To view the warranty information for your product, see the links provided below:
HPE ProLiant and IA-32 Servers and Options
www.hpe.com/support/ProLiantServers-Warranties
HPE Enterprise and Cloudline Servers
www.hpe.com/support/EnterpriseServers-Warranties
HPE Storage Products
www.hpe.com/support/Storage-Warranties
HPE Networking Products
www.hpe.com/support/Networking-Warranties
66Support and other resources
Regulatory information
To view the regulatory information for your product, view the Safety and Compliance Information for
Server, Storage, Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise
Hewlett Packard Enterprise is committed to providing our customers with information about the chemical
substances in our products as needed to comply with legal requirements such as REACH (Regulation EC
No 1907/2006 of the European Parliament and the Council). A chemical information report for this product
can be found at:
www.hpe.com/info/reach
For Hewlett Packard Enterprise product environmental and safety information and compliance data,
including RoHS and REACH, see:
www.hpe.com/info/ecodata
For Hewlett Packard Enterprise environmental information, including company programs, product
recycling, and energy efficiency, see:
www.hpe.com/info/environment
Documentation feedback
Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us
improve the documentation, send any errors, suggestions, or comments to Documentation Feedback
(docsfeedback@hpe.com). When submitting your feedback, include the document title, part number,
edition, and publication date located on the front cover of the document. For online help content, include
the product name, product version, help edition, and publication date located on the legal notices page.
Support and other resources67