HP E7671A, E7674A, E7675A, E7676A Installation Manual

power distribution unit
kit
fits hp 19-inch racks
E7671A E7674A E7675A E7676A
Contents
Notice
The information contained in this document is subject to change without notice. HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS
MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Hewlett-Packard Company shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard Company.
Copyright: 2002 by HEWLETT-PACKARD COMPANY .
WARNING!
IMPORTANT SAFETY NOTE FOR INSTALLATION
For installations using wide-voltage-range-rated switchless power distribution units (PDU part numbers E7671-63001, E7674-63001, E7675-63001, and E7676-63001) for connection to an uninterruptable power supply (UPS) or other AC source:
n CHECK THE VOLTAGE before connecting any equipment to the PDU! Failure to check the voltage could lead to severe equipment damage!
The voltage of the PDU receptacles equals the voltage of the receptacle to which the PDU is connected. This voltage must be within the input voltage range of the equipment installed in the rack.
n CHECK THE POWER SOURCE RECEPTACLE to be sure it is installed near the rack and is easily accessible, so that the plug on the PDU power supply cord can serve as the disconnect device for the rack.
n CHECK THE TOTAL INPUT CURRENT ratings of the equipment installed in the rack to avoid overloading the PDU or any uninterruptable power supply (UPS) to which it may be connected.
The output current rating of the PDU equals the output current rating of the power source to which the PDU is connected, but not more than the maximum current rating (amperage) marked on the PDU.
n CHECK THE GROUNDING, because when installing rack-mounted products with this PDU, there is a risk of high leakage current. Reliable ground circuit continuity is vital for safe operation of this product. To reduce the risk of electric shock, earth (ground) connection is essential before connecting the PDU. Never operate this PDU with the ground conductor disconnected.
2
DECLARATION OF CONFORMITY
according to ISO/IEC Guide 22 and EN 45014
Manufacturer's Name: Hewlett-Packard Company Manufacturer's Address: 10955 Tantau Avenue
Cupertino, CA 95014 USA
declares, that the product
Product Name: Power Distribution Units Model Number(s): E7670-63001, E7671-63001, E7672-63001
E7674-63001, E7675-63001, E7676-63001
Product Options: ALL
conforms to the following Product Specifications:
Safety: IEC 950:1991+A1+A2+A3+A4
EN 60950:1992+A1+A2+A3+A4
Contents
Supplementary Information: The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and 93/68/EEC and carries the CE-Marking accordingly.
Mt. View, CA 94043 1 November, 2002 Location Date Susan Kipers, Business Manager
For Compliance Information: European Contact: Your Local Hewlett-Packard Sales and Service Office or
Hewlett-Packard Gmbh, Department ZQ / Standards Europe, Herrenberger Strasse 130, D-71034 Boeblingen
(FAX: +49-7031-14-3143
3
Loading...
+ 7 hidden pages