Index ..................................................................................................... 159
Contents 5
Page 6
Contents 6
Page 7
Front Matter
Notice
The information contained in this document is subject to change without
notice.
Agilent Technologies shall not be liable for any errors contained in this
document. Agilent Technologies makes no warranties of any kind with
regard to this document, whether express or implied. Agilent Technologies
specifically disclaims the implied warranties of merchantability and fitness
for a particular purpose. Agilent Technologies shall not be liable for any
direct, indirect, special, incidental, or consequential damages, whether
based on contract, tort, or any other legal theory, in connection with the
furnishing of this document or the use of the information in this document.
Warranty Information
A copy of the specific warranty terms applicable to your Agilent
Technologies product and replacement parts (as applicable) is shipped with
your product. If the warranty terms are not included or if you want a copy
of the warranty terms, contact Agilent Technologies, Inc.
U.S. Government Restricted Rights
The Software and Documentation have been developed entirely at private
expense. They are delivered and licensed as "commercial computer
software" as defined in DFARS 252.227- 7013 (Oct 1988), DFARS 252.2117015 (May 1991) or DFARS 252.227-7014 (Jun 1995), as a "commercial
item" as defined in FAR 2.101(a), or as "Restricted computer software" as
defined in FAR 52.227-19 (Jun 1987) (or any equivalent agency regulation
or contract clause), whichever is applicable. You have only those rights
provided for such Software and Documentation by the applicable FAR or
DFARS clause or the Agilent standard software agreement for the product
involved.
Declaration of Conformity
See the next page for the Declaration of Conformity for the E5810A
LAN/GPIB Gateway for Windows.
7
Page 8
DECLARATION OF CONFORMITY
According to ISO/IEC Guide 22 and CEN/CENELEC EN 45014
Manufacturer’s Name:
Agilent Technologies, Incorporated
Manufacturer’s Address:
815 – 14
th
St. SW
Loveland, CO 80537
USA
Declares under sole responsibility that the product as originally delivered
Product Name:
LAN/GPIB Gateway for Windows
Model Number:
E5810A
Product Options:
This declaration covers all options of the above product(s)
complies with the essential requirements of the following applicable European Directives, and
carries the CE marking accordingly:
EMC Directive (89/336/EEC, amended by 93/68/EEC)
Low Voltage Directive (73/23/EEC, amended by 93/68/EEC)
and conforms with the following product standards:
EMCStandard
IEC 61326-1:1997+A1:1998 / EN 61326-1:1997+A1:1998
CISPR 11:1990 / EN 55011:1991
IEC 61000-4-2:1995+A1:1998 / EN 61000-4-2:1995
IEC 61000-4-3:1995 / EN 61000-4-3:1995
IEC 61000-4-4:1995 / EN 61000-4-4:1995
IEC 61000-4-5:1995 / EN 61000-4-5:1995
IEC 61000-4-6:1996 / EN 61000-4-6:1996
IEC 61000-4-11:1994 / EN 61000-4-11:1994
The product was tested in a typical configuration with Agilent Technologies test systems.
Safety
IEC 61010-1:2001 / EN 61010-1:2001
Canada: CSA C22.2 No. 1010.1:1992
UL 61010B-1: 2003
Supplementary Information:
This DoC applies to above-listed products placed on the EU market after:
20 April 2004
Date
Ray Corson
Product Regulations Program Manager
For further information, please contact your local Agilent Technologies sales office, agent or distributor,
or Agilent Technologies Deutschland GmbH, Herrenberger Straße 130, D 71034 Böblingen, Germany.
8
Page 9
ICES Statement
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à la norme NMB-001 du Canada.
Safety Symbols
Instruction manual symbol affixed to
product. Indicates that the user must
refer to the manual for specific
WARNING or CAUTION information to
avoid personal injury or damage to the
product.
Indicates the field wiring terminal that
must be connected to earth ground
before operating the equipment —
protects against electrical shock in
case of fault.
WARNING
Alternating current (AC).
Direct current (DC).
Warning. Risk of electrical shock.
Calls attention to a procedure,
practice, or condition that could cause
bodily injury or death.
or
Frame or chassis ground terminal—
typically connects to the equipment's
metal frame
CAUTION
Calls attention to a procedure,
practice, or condition that could
possibly cause damage to equipment
or permanent loss of data.
WARNINGS
The following general safety precautions must be observed during all
phases of operation, service, and repair of this product. Failure to comply
with these precautions or with specific warnings elsewhere in this manual
violates safety standards of design, manufacture, and intended use of the
product. Agilent Technologies assumes no liability for the customer's failure
to comply with these requirements.
Ground the equipment: For Safety Class 1 equipment (equipment having a
protective earth terminal), an uninterruptible safety earth ground must be
provided from the mains power source to the product input wiring terminals
or supplied power cable.
DO NOT operate the product in an explosive atmosphere or in the presence of
flammable gases or fumes.
For continued protection against fire, replace the line fuse(s) only with
fuse(s) of the same voltage and current rating and type. DO NOT use
repaired fuses or short-circuited fuse holders.
9
Page 10
Keep away from live circuits: Operating personnel must not remove
equipment covers or shields. Procedures involving the removal of covers or
shields are for use by service-trained personnel only. Under certain
conditions, dangerous voltages may exist even with the equipment switched
off. To avoid dangerous electrical shock, DO NOT perform procedures
involving cover or shield removal unless you are qualified to do so.
DO NOT operate damaged equipment:Whenever it is possible that the safety
protection features built into this product have been impaired, either through
physical damage, excessive moisture, or any other reason, REMOVE
POWER and do not use the product until safe operation can be verified by
service-trained personnel. If necessary, return the product to Agilent for
service and repair to ensure that safety features are maintained.
DO NOT service or adjust alone: Do not attempt internal service or
adjustment unless another person, capable of rendering first aid and
resuscitation, is present.
DO NOT substitute parts or modify equipment: Because of the danger of
introducing additional hazards, do not install substitute parts or perform any
unauthorized modification to the product. Return the product to Agilent for
service and repair to ensure that safety features are maintained.
Documentation History
All Editions and Updates of this manual and their creation date are listed
below. The first Edition of the manual is Edition 1. The Edition number
increments by 1 whenever the manual is revised. Updates, which are issued
between Editions, contain replacement pages to correct or add additional
information to the current Edition of the manual. Whenever a new Edition is
created, it will contain all of the Update information for the previous Edition.
Each new Edition or Update also includes a revised copy of this
documentation history page.
Windows® and Windows NT® are U.S. registered trademarks of Microsoft
Corporation.
Support Information
Support information for the E5810A LAN/GPIB Gateway for Windows
follows. When calling Agilent with support questions, please have the
following information available so we can provide you with a quicker solution
to the problem.
E5810A Serial Number (printed on bottom of the unit and displayed
on the
Description of the Problem
Corrective actions already tried (see Chapter 4 - Troubleshooting
Information for suggested troubleshooting tips)
Welcome page of the E5810A Web access)
Contacting Agilent You can reach Agilent Technologies at this telephone number in the
Americas:
Americas Call Center: 1-800-452-4444
For other countries, contact your country’s Agilent support
organization. A list of contact information for other countries is
available on the Agilent Internet site:
www.agilent.com/find/assist.
A list of other Agilent Web sites follows.
www.agilent.com/find/e5810aThe latest E5810A product information with links to key
Web sites such as FAQs, Data Sheets, etc.
www.agilent.com/find/iolibUpdate the Agilent IO Libraries Suite software
www.agilent.com/find/techsupportThe latest customer support information
www.agilent.com/find/ADNConnectivity resources all in one place
www.agilent.com/find/manualsTechnical support information, including manuals,
application notes, FAQs, and software and firmware
downloads
www.agilent.com/find/connectivityFor connection, communication and control of test
instruments from your computer, you can find out the
latest in the world of connectivity.
User’s Guide Information
This Agilent E5810A LAN/GPIB Gateway for Windows User’s Guide
describes installation, configuration, and use of an E5810A LAN/GPIB
Gateway for Windows that is connected to an Enterprise (corporate)
network, to a Local Network, or directly to a PC.
NOTE
All Agilent IO Libraries information in this guide refers to
Agilent IO Libraries Suite version 14.0. For specific information on other
versions of the Agilent IO Libraries or Agilent IO Libraries Suite, see the
documentation for that version. You can download both updates and
older versions (for backward compatibility) of the IO Libraries software at
http://www.agilent.com/find/iolib.
12
Page 13
What’s in This
A listing of the guide contents follows.
Guide?
NOTE
This guide is NOT a tutorial on Local Area Networks (LANs) or specific
LAN operation. Consult your Information Technology (IT) department for
LAN specifics for your application.
ChapterDescription
Chapter 1 - E5810 DescriptionDescribes the E5810, including hardware description and
network operation.
Chapter 2 - Installing the E5810Shows how to install the E5810 and the
Agilent IO Libraries Suite.
Chapter 3 - Using E5810 Web
Access
Chapter 4 - Troubleshooting
Information
Appendix A - E5810
Specifications
Appendix B - Using the Telnet
Utility
GlossaryDefines some of the technical terms used in this guide.
Accessing an
Electronic Copy of
This Guide
There are three ways you can access an electronic (.pdf) version of this
guide, as follows. You will need Adobe Acrobat Reader Version 3.0 or later
to view the electronic version.
Shows how to use the E5810 Web access to interface with
the E5810 from your PC.
Shows some ways to troubleshoot the E5810, including front
panel, network, PC client, and instrument checks.
Provides specifications for the E5810.
Provides a summary of using the Telnet utility.
Access From the E5810 Web Access. After the E5810 is installed,
you can access an electronic version of the manual by going to the
Welcome page and clicking User’s Guide (under the E5810
Documentation
heading).
Access from the IO Control. If the Agilent IO Libraries Suite is
installed, a blue circled IO icon appears on the right hand side of the
Windows toolbar. To access an electronic version of this guide, click
the IO icon, then click
Users Guide
.
Documentation and then click E5810 LAN/GPIB
13
Page 14
Access from the Web. On your Web browser address line, type:
www.agilent.com/find/manuals and navigate to the E5810
manual.
E5810 Related
Documentation
ProductRelated Documentation
Agilent IO
Libraries Suite
VISATo use the E5810 with VISA, you must configure a remote interface (also
SICLTo develop and use SICL I/O applications for the E5810 in Windows,
T&M ToolkitTo develop programs in Visual Studio .NET, see the Agilent T&M Toolkit
Suggested documentation you can use for E5810 LAN/GPIB Gateway for
Windows operation with the listed I/O application software products follow.
After the Agilent IO Libraries Suite has been installed on your PC, .pdf files
of the Agilent IO Libraries Suite documentation including VISA and SICL
User’s Guides are available. Click the blue IO icon on the Windows taskbar
and then click Documentation.
The Agilent IO Libraries Suite Getting Started Guide and the IO Libraries Suite Online Help describe the use of the IO Libraries Suite.
known as VISA LAN Client operation). To develop and use VISA applications
for the E5810, see the Agilent VISA User’s Guide.
see the Agilent SICL User’s Guide for Windows.
product. Information is available at www.agilent.com/find/toolkit.
14
Page 15
1
E5810 Description
Page 16
E5810 Description
This chapter gives guidelines to install, configure, and troubleshoot the
E5810 LAN/GPIB Gateway for Windows (E5810) for use with supported,
network-equipped computer systems, including:
The E5810 LAN/GPIB Gateway for Windows provides a gateway between
network-equipped computer systems and GPIB and/or RS-232 based
instruments. This section provides an overview of E5810 hardware,
including:
Typical Network Connections
Front Panel Features
Rear Panel Features
Power-On and Default Settings
Rack Mount Kit (Optional)
Typical Network Connections
The E5810 can be connected to an Enterprise (corporate) network, to a
Local network (isolated LAN), or directly to a PC and can be connected to
as many as 14 GPIB instruments and/or to one RS-232 instrument. The
E5810 allows I/O applications to obtain measurement data either locally or
remotely from GPIB and/or RS-232 instrumentation. The following figures
show typical network and direct PC connections to an E5810.
Enterprise Network
Connections
Enterprise Network Connections
To Enterprise
Network
In a typical Enterprise (corporate) network, the E5810 is connected to the
network by a router or switch. For this configuration, the E5810 is visible to
the Enterprise network.
Chapter 117
Typically Router
or Switch
LAN
Patch
Cables
E5810
LAN GPIB RS232
GPIB
To RS-232
Instrument
GPIB Instruments
GPIB Ports
GPIB
GPIB
Page 18
E5810 Description
E5810 Hardware Description
Local Network
Connections
Local Network Connections (Multiple PCs can Communicate with the E5810)
Typically, a hub or switch is used for local network configuration. A cable/
DSL router may be used to provide a DHCP Server. For typical direct
connections from a PC to the E5810, a
crossover cable is connected from
the E5810 LAN port to a LAN card on the PC. For Local Network or direct
PC connections, the E5810 is not visible on the Enterprise network.
LAN Patch
Cable
Typically Hub
or Switch
E5810
LAN GPIB RS232
GPIB
To RS-232
Instrument
GPIB Instruments
GPIB
GPIB
GPIB
Direct PC Connection (Only One PC can Communicate with the E5810)
Crossover
Cable
Connect to
PC LAN Card
E5810
LAN GPIB RS232
GPIB
To RS-232
Instrument
GPIB Instruments
18Chapter 1
GPIB
GPIB
GPIB
Page 19
E5810 Description
E5810 Hardware Description
Front Panel Features
This section describes the E5810 front panel features,
NOTE
The Hostname, if detected, is displayed on the first line of the E5810 front
panel display. The IP Address of the E5810 is displayed on the second
line of the E5810 front panel display.
Front Panel
Display/LEDs
Display
A 16-character, two-line display
that displays the Hostname (if
known) and the IP Address plus
system messages.
Power LED
When ON (Green), shows AC
power is applied to the E5810.
This figure shows E5810 front panel functions.
agiltb6
169.254.58.10
LAN LED
Flashes for activity on the LAN.
Preset Button
Depressing for <10 sec temporarily resets only
the default password (E5810). Depressing for
>10 sec resets all parameters to factory default
values and reboots the E5810.
E5810A
LAN/GPIB Gateway
PowerFault
Activity
LAN GPIB RS232
Fault LED
If ON (RED) for >10 sec,
indicates possible hardware
failure. Briefly turns ON at
power-on while the E5810
is running its self-test.
Preset
GPIB LED
Flashes for GPIB instrument activity.
RS232 LED
Flashes for RS-232 instrument activity.
Chapter 119
Page 20
E5810 Description
E5810 Hardware Description
Typical Power-On
Sequence
This figure shows major steps in a typical power-on sequence for an E5810
that is connected to a network that supports Dynamic Host Configuration
Protocol (DHCP) and Domain Name Service (DNS). If the network does not
support DHCP and/or DNS, the power-on sequence may be different than
that shown.
Power Applied
Display is blank, Power (Green) and Fault (Red) are ON.
E5810A
LAN/GPIB Gateway
PowerFault
Searching for DHCP Server
Display displays message, Power (Green) is ON and Fault (Red) is OFF. This typically takes
20 to 30 seconds and can take up to 150 seconds if a DHCP Server is not present.
Searching for
169.254.58.10
DHCP Server...
PowerFault
Activity
LAN GPIB RS232
Activity
LAN GPIB RS232
E5810A
LAN/GPIB Gateway
Preset
Preset
IP Address and Hostname Displayed
Display displays Hostname, (if known) and IP address, only Power (Green) is ON.
When power is first applied to the E5810 and the hardware self-test has
completed, the E5810 is initialized to the factory-set default configuration.
This table shows the default configuration parameter settings for the E5810.
The E5810 uses these default configuration values until you set any other
configuration values. The E5810 also uses these values when you press the
Preset button and hold it down for >10 seconds. See Chapter 3 - Using
E5810 Web Access for a description of each parameter.
RS-232 Stop Bits:1
<MAC Addr>
I/O Timeout (sec):120 secPasswordE5810
GPIB SICL Interface Name:gpib0
Preset Button
Operation
The Preset button on the front panel of the E5810 is used to reset the E5810
to its default configuration values (preset at the factory). As shown in the
figure on the next page, the
Preset button has two modes of operation:
If you depress the Preset button and release it in <10 seconds, only
the E5810 password is temporarily changed and is reset to its
default value (E5810). If you cycle power or reboot the E5810, the
E5810 will return to the actual password that was previously set. All
existing configuration values remain unchanged.
If you depress and hold the Preset button for 10 seconds or more, all
configuration values are reset to their factory default values and the
E5810 is rebooted. All network connections to the E5810, if any, are
also terminated without any cleanups.
Chapter 121
Page 22
E5810 Description
E5810 Hardware Description
Depress and Quickly (<10 seconds) Release the Preset Button *
- The E5810 password is temporarily reset to its factory default (E5810).
- All other configuration parameters remain unchanged.
- This state is maintained until the next time the E5810 is booted.
- The front panel display sequence is as follows.
Hostname
IP Address
Temporary Pass-
word = "E5810"
* Release the Preset button when Temporary Password = "E5810" is displayed.
Depress and Hold the Preset Button (>10 Seconds)**
- All configuration parameters are set to their default values.
- The E5810 is rebooted.
- The front panel display sequence is as follows.
Hostname
IP Address
Hostname
IP Address
Temporary Pass-
word = "E5810"
Hold to Reboot
& Set Defaults
Setting Factory
Defaults
Rebooting
E5810...
** Release the Preset button when Rebooting E5810... is displayed.
22Chapter 1
Page 23
E5810 Hardware Description
Rear Panel Features
This figure shows the rear panel features of the E5810.
E5810 Description
LAN Port
Connect one end of a LAN patch
cable to this port and connect
the other end of the cable to a
router/hub/switch.
OR
Connect one end of a crossover
cable to this port and the other
end of the cable to a LAN card
on your PC.
LAN Activity Lights
When the green Ln light is ON, the E5810
is successfully connected to the LAN. When
the green Tx light flashes, the E5810 is
transmitting data onto the LAN.
Serial Number and Ethernet Address
The E5810 Serial Number and Ethernet
(MAC) Address are printed on a label on
the underside of the E5810.
GPIB Port
Connect one end of GPIB
cable to this port and connect
other end of cable to a GPIB
instrument.
RS232 Port
Connect one end of RS-232
cable to this port and connect
other end of cable to an
RS-232 instrument.
POWER Port
Connect AC power cord to this
port and plug cord into an AC
outlet. The E5810 does not
have a power switch. The Mains
disconnect is to unplug the AC
power cord from the AC outlet.
The power supply automatically
conforms to the input voltage
and frequency supplied, within
100V - 240V (±10%) @ 47-63 Hz.
Rack Mount Kit (Optional)
As desired, you can mount up to two E5810 in a standard EIA rack using the
E5810 Rack Mount Kit (E5810 Opt 100 or E5810-00100). The E5810 is one
standard half-rack unit wide and one standard rack unit high. See the
E5810-00100 Rack Mount Kit for installation instructions.
Chapter 123
Page 24
E5810 Description
E5810 Software/Firmware
E5810 Software/Firmware
The E5810 LAN/GPIB Gateway for Windows provides an interface
(gateway) that allows networked computers to talk or listen to GPIB and/or
RS-232 devices via Local Area Network (LAN) connections. The E5810
connects a network (Enterprise or Local) from PCs with Windows
98/2000/NT
describes E5810 software/firmware features, including:
E5810 Operating Features
Typical Network Operation
Software/Firmware Architecture
Typical Network IP Addressing
Communicating with the E5810
®/Me/XP to GPIB and/or RS-232 instruments. This section
24Chapter 1
Page 25
E5810 Operating Features
FeatureDescription
E5810 Description
E5810 Software/Firmware
Remote access to
instruments via LAN
I/O Software IncludedThe E5810 includes the Agilent IO Libraries Suite, which includes
Supports DHCP
Protocol
Access and control up to 14 GPIB and/or one RS-232 instrument via a
10BASE-T/100BASE-TX Ethernet. The E5810 detects the network
and configures itself to the appropriate speed. The E5810 has a
standard RJ-45 LAN connector. You can use adapters to connect
other interface types, such as optical or wireless LAN.
Agilent Virtual Instrument Software Architecture (VISA), VISA COM,
Standard Instrument Control Library (SICL), and several I/O utilities.
This standard software provides compatibility with different hardware
and software vendors. It provides the I/O software layer used when
accessing the E5810. You can use a standard programming language,
such as Visual Basic, Visual C++, Agilent VEE, etc.
The E5810 supports all I/O application operations provided by VISA,
VISA COM, SICL, and Agilent VEE. The E5810 is supported on
Microsoft Windows 98/2000/Me/NT/XP; however, if you are using
Windows NT, you will need to download Agilent IO Libraries version
M.01.01 from http://www.agilent.com/find/iolib.
You can also use the Agilent IntuiLink software (included with some
Agilent products) to download data and send waveforms to the source,
with no programming.
The E5810 supports Dynamic Host Configuration Protocol (DHCP) to
get its IP address. Although the E5810 defaults to using DHCP, you
can turn DHCP OFF and statically assign the E5810 IP address.
Ease of UseBuilt-in Web access and front panel display allow you to easily set up,
configure, and use the E5810. You can connect multiple E5810s in a
test system. Each E5810 creates a separate GPIB bus.
Chapter 125
Page 26
E5810 Description
E5810 Software/Firmware
Typical Network Operation
The E5810 provides a network gateway between network-equipped
computer systems and GPIB and/or RS-232 based instruments. The
gateway enables users to obtain measurement data either locally or
remotely from GPIB and/or RS-232 instruments. See “Typical Network
Connections” in this chapter for typical connections to Enterprise or Local
Networks or to a PC.
The E5810 connects a local area network (LAN) from the computer system
to the GPIB and/or RS-232 buses. Network-equipped computer systems
that are supported for use with the E5810 include PCs with Windows
98/2000/NT/Me/XP. Using the client/server model of computing, the
computer system is the
client, and the E5810 is the server.
Client System
LAN
Server
E5810
GPIB Instruments
GPIB
RS-232 Instrument
RS-232
Thus, applications running on the computer system can transparently
interface to GPIB and RS-232 based instruments over the LAN. Since
several computer systems can access the E5810, groups of users can share
access to the same GPIB and/or RS-232 instruments via the E5810. In
addition, existing I/O applications that are supported with the E5810 and are
designed for GPIB or RS-232 can use the E5810 without modification other
than an address change.
The E5810 and its attached instruments can be placed anywhere on the
network (rather than with a particular controller or server computer system).
This includes networks which span different geographic locations, such as
when networked computer systems are located at several different sites.
Thus, GPIB and RS-232 instruments can be located where they are most
convenient. In addition, you can have more than one E5810 on a network,
providing “clusters” of GPIB and/or RS-232 instrumentation at different
locations.
26Chapter 1
Page 27
E5810 Description
E5810 Software/Firmware
Software/Firmware Architecture
To program instruments from your PC via the E5810 using a programming
language such as C or Visual Basic, you must install and configure the
Agilent IO Libraries Suite on the client PC.
Client System
Architecture
Client System
Application
Agilent VISA
LAN Client
SICL
As shown in the following figure, the client (PC) system contains the VISA
LAN client software as well as the TCP/IP LAN software needed to access
the E5810. The E5810 contains LAN server and TCP/IP LAN firmware so it
acts as the LAN server.
The VISA LAN client software is also known as the Remote IO Client
software. It is part of the Agilent IO Libraries Suite. The LAN server software
is also called the Remote IO Server software.
The VISA LAN client software uses the TCP/IP LAN protocol suite to pass
messages between the client system and the server (the E5810). Therefore,
the client sends I/O requests over the network to the server. The server then
executes those I/O requests on the appropriate GPIB and/or RS-232 based
instrument(s) connected to the server.
Server (E5810)Instrument
LAN Server
TCP
IP I/O
Driver
LAN Interface
Instrument
Firmware
TCP
IP
LAN Interface
Chapter 127
GPIB or RS-232 bus
Page 28
E5810 Description
E5810 Software/Firmware
How IO Application
Software Works
With the E5810
Before trying to perform an I/O application operation on the E5810 GPIB
interface and the GPIB bus, the Remote IO Client software in the client
computer system establishes a network connection to the remote I/O server
(the E5810). Once the client establishes a connection, the client can begin
to send I/O requests to the E5810.
The E5810 (remote I/O server) can have multiple clients connected and
being serviced at any given time. The maximum number of concurrent client
connections depends on memory usage in the E5810, including the number
of clients and the number of current sessions running on those clients.
However, up to 16 client connections can be running concurrently. Thus, if
the maximum number of client connections to the E5810 has not been
exceeded, the connection is allowed to occur.
Although several instruments can be connected to the E5810 GPIB bus,
only one I/O application operation can occur on the GPIB bus at any given
time. Therefore, once a client’s request begins to execute on the GPIB, all
other client requests for operations on the GPIB must wait until the current
client request completes. Client requests are serviced in a first come, first
served manner, unless they are prohibited by interface or device locks.
If a client has a sequence of I/O application operations to perform that
should not be preempted, the client should obtain a lock on the E5810 GPIB
interface or device. Once the client’s sequence has completed, it should
release its lock, allowing access for other clients.
When a client closes a connection, the E5810 frees up the resources
allocated to that client, including any locks, pending I/O requests, memory
usage, etc.
28Chapter 1
Page 29
E5810 Description
E5810 Software/Firmware
Typical Network IP Addressing
This section describes typical Enterprise network IP addresses and subnet
addresses on the network. This figure shows a typical Enterprise network,
consisting of a Router (Gateway), a corporate Dynamic Host Configuration
Protocol (DHCP) Server, and a subnet consisting of six hosts (two E5810s
and four host PCs.) The Router sends packets of information to each host,
based on the IP address of the host. The subnet is defined by the
Subnet AddressingA Subnet Mask is used to determine to which subnet an IP address belongs.
An IP address has two components: the network address and the host
address. For example, assuming IP address 156.215.117.109 is part of a
Class B network, the first two numbers (156.215) represent the Class B
network address and the second two numbers (117.109) identify a specific
host on this network. See the
network.
For the subnet in the figure, an example IP address for E5810 #1 is
156.140.104.72, where 156.140 represents the network address and 104.72
represents the E5810 #1 host address. An example IP address for E5810 #2
is 156.140.104.75, where 156.140 represents the network address and
104.75 represents the E5810 #2 host address.
Glossary for a description of a Class B
E5810 IP Address
Assignment
For the E5810 to operate on an Enterprise network, three addresses must
be identified: E5810 IP Address, Subnet Mask, and Default Gateway
Address.
If the Enterprise network supports Dynamic Host Configuration Protocol
(DHCP), the E5810 will automatically receive an IP address, Subnet Mask,
and Default Gateway from the DHCP Server. If the network does not support
DHCP, the E5810 IP address must be configured manually.
In addition, if the network supports Domain Name Service (DNS), an E5810
Hostname can be configured. This can be done in one of two ways:
The DNS Server IP Address is provided by the DHCP Server (this is
transparent to the user).
A DNS Server IP address is supplied by the System Administrator
and entered on the
Configuring your E5810 LAN/GPIB Gateway page.
30Chapter 1
Page 31
E5810 Description
E5810 Software/Firmware
Communicating with the E5810
There are two ways you can communicate with the E5810 via a network: use
the E5810 Web access or use a supported programming language with the
Agilent IO Libraries Suite.
Using the E5810 Web Access
Agilent IO Libraries Are Not Required
Use a supported Web
Browser to access and
configure the E5810.
LANPCE5810Instruments
The E5810 provides a
Web Server that allows
for access via the Web.
Using Supported Programming Languages
Agilent IO Libraries Are Required
LANPCE5810Instruments
GPIB
Instruments are programmed
using standard instrument
commands (such as SCPI)
via the Web browser.
GPIB
To program connected
instruments, you must
install and configure the
Agilent IO Libraries Suite
on your PC.
The interface must be
configured for VISA
LAN Client operation.
Program instruments
using a supported
programming language
(such as C, etc.) and
VISA or SICL.
Chapter 131
Page 32
E5810 Description
E5810 Software/Firmware
Using E5810 Web
Access
Since the E5810 is Web-enabled, you can communicate with the E5810
from a supported Web browser. The E5810 supports Internet Explorer 4.0 or
higher and Netscape Navigator 4.7 and higher. Typing in the E5810 IP
address (or E5810 hostname, if known) on your Web browser address line
and then pressing the
Enter key displays the E5810 Welcome page.
You can use the Web access to configure the E5810 and to communicate
with GPIB and/or RS-232 instruments. For example, using the
your E5810 LAN/GPIB Gateway
page of the E5810 interface, you can view
Configuring
and modify the configuration of the E5810. Or, you can communicate with
installed GPIB and/or RS-232 instruments using the
Instruments Connected to your E5810
Using E5810 Web Access
for information on E5810 Web access.
page of the interface. See Chapter 3 -
Find and Control
32Chapter 1
Page 33
E5810 Description
E5810 Software/Firmware
Using a Supported
Programming
Language
To use applications that require the Agilent IO Libraries, you must install and
configure the Agilent IO Libraries Suite on each PC to be used for
programming. Then, you can program connected instruments using a
supported programming language (such as C or Visual Basic) using the
Agilent Virtual Instrument Software Architecture (VISA), VISA COM, or
Standard Instrument Control Language (SICL). See the
Suite Getting Started Guide
more information on the Agilent IO Libraries.
and Agilent IO Libraries Suite Online Help for
Agilent IO Libraries
Chapter 133
Page 34
Notes:
E5810 Description
E5810 Software/Firmware
34Chapter 1
Page 35
2
Installing the E5810
Page 36
Installing the E5810
This chapter shows suggested steps to install the Agilent E5810 LAN/GPIB
Gateway for Windows on LAN networks for Windows PCs, including:
Installation Flowchart
Before You Install the E5810
Getting Network Information
Configuring the E5810 on a Local Network
Installing the E5810 on an Enterprise Network
Verifying Instrument Communication
Installing and Configuring the Agilent IO Libraries Suite
NOTE
All Agilent IO Libraries information in this guide refers to
Agilent IO Libraries Suite version 14.0. For specific information on other
versions of the Agilent IO Libraries or Agilent IO Libraries Suite, see the
documentation for that version. You can download both updates and
older versions (for backward compatibility) of the IO Libraries software at
http://www.agilent.com/find/iolib.
The Agilent E5810 is supported with PCs running Windows 98,
Windows Me, Windows 2000, Windows NT, or Windows XP operating
systems. Agilent IO Libraries Suite 14.0 is not supported with
Windows NT, so if you are using Windows NT, you must download an
earlier version of the IO Libraries software from the Web site mentioned
above.
36Chapter 2
Page 37
Installing the E5810
Installation Flowchart
Installation Flowchart
This figure shows suggested steps to install and configure an E5810 on an
Enterprise or Local network. See the next page for more details.
Before You
Install
the E5810
Get
Network
Information
DHCP
Enterprise Network
Install E5810
on
Enterprise Network
non-DHCP
Enterprise Network
Configure E5810
on
Local Network
Install E5810
on
Enterprise Network
Verify
Instrument
Communication
Install
Agilent IO Libraries
Suite
Local Network
Configure E5810
on
Local Network
Chapter 237
Page 38
Installing the E5810
Installation Flowchart
You can install the E5810 on an Enterprise (corporate) network that
supports Dynamic Host Configuration Protocol (DHCP), an Enterprise
network that does not support DHCP, or a Local network.
NOTE
If you plan to install the E5810 on an Enterprise network, contact your
Information Technology (IT) Department to see if the network supports
Dynamic Host Configuration Protocol (DHCP).
Installing the E5810
on a DHCP
Enterprise Network
Installing the E5810
on a non-DHCP
Enterprise Network
Installing the E5810
on a Local Network
See these sections to install an E5810 on an Enterprise network that does
support DHCP
:
Before You Install the E5810
Getting Network Information
Installing the E5810 on an Enterprise Network
Verifying Instrument Communication
Installing and Configuring the Agilent IO Libraries Suite
To install the E5810 on an Enterprise network that does not support DHCP,
you may need to first configure the E5810 on a Local network and then
install the E5810 on the Enterprise network. See these sections to install an
E5810 on an Enterprise network that
does not support DHCP:
Before You Install the E5810
Getting Network Information
Configuring the E5810 on a Local Network
Installing the E5810 on an Enterprise Network
Verifying Instrument Communication
Installing and Configuring the Agilent IO Libraries Suite
If you plan to install the E5810 on a Local network, you may not need to
contact your IT department. However, you will need to determine network
parameters. See these sections to install and configure an E5810 on a Local
network:
Before You Install the E5810
Getting Network Information
Configuring the E5810 on a Local Network
Verifying Instrument Communication
Installing and Configuring the Agilent IO Libraries Suite
38Chapter 2
Page 39
Installing the E5810
Before You Install the E5810
Before You Install the E5810
Before you connect the E5810 to a network, you should:
Check Shipment Items
Check System Requirements
Rack Mount the E5810 (Optional)
Check Shipment Items
In addition to this E5810 LAN/GPIB Gateway for Windows User’s Guide,
your E5810 shipment should include the items shown in the following figure.
If any items are missing or damaged, contact Agilent Technologies. See
“Support Information” in the
Front Matter of this guide for addresses.
E5810 LAN/GPIB Gateway for Windows
AC Power Cord
Appropriate AC power cord
for your country.
E5810 Documentation
- E5810 Getting Started Poster
- E5810 User's Guide
- E5810 Warranty Statement
- Software License Agreement
Rack Mount Kit (Optional)
E5810-00100 Rack Mount Kit
Agilent Automation-
Ready CD
Chapter 239
Page 40
Installing the E5810
Before You Install the E5810
Check System Requirements
Before you install the E5810 on a network, you should verify that your
system meets the
install and use the Agilent IO Libraries Suite with the E5810. Adding
additional RAM may improve overall system performance.
Note: If your PC does not meet these minimum requirements, see
http://www.agilent.com/find/iolib/osmatrix for information on
earlier revisions of the IO Libraries software.
ItemMinimum Requirements
Hardware Requirements
minimum hardware and software requirements listed to
Ethernet
Connections
Software Requirements
PC Operation/
Memory
Hard Drive Space215 MB for installation: 160 MB for Microsoft
Operating SystemWindows 98 SE, Windows Me, Windows 2000
Agilent IO LibrariesAgilent IO Libraries Version L.01.01 or greater, or
Web BrowserFor IO Libraries Suite: Internet Explorer 5.01 or
10BASE-T or 100BASE-TX compliant
200 MHz Pentium II (800 MHz recommended)
and 64 MBytes RAM (96 MB recommended).
.NET Framework, 55 MB for Agilent IO Libraries
Suite
125 MB for operation: 70 MB for Microsoft .NET
Framework, 55 MB for Agilent IO Libraries Suite
(Service Pack 4 or later), or Windows XP
(Service Pack 1 or later).
Agilent IO Libraries Suite Version 14.0 or greater.
higher.
For E5810 Web access: Internet Explorer 4.0 or
higher, or Netscape Navigator 4.7 or higher.
Internet Explorer 5.5 or higher, or Netscape
Navigator 6.2 or higher, is recommended.
40Chapter 2
Page 41
Installing the E5810
Before You Install the E5810
Rack-Mount the E5810 (Optional)
As desired, you can mount up to two E5810s in a single standard EIA rack
space using the E5810 Rack Mount Kit (E5810 Option 100 or
E5810-00100). The E5810 is one standard half-rack unit wide and one
standard rack unit high. See the
instructions.
NOTE
You may want to configure the E5810 and ensure proper operation on the
Enterprise or Local network before rack-mounting the unit.
E5810-00100 Rack Mount Kit for installation
Chapter 241
Page 42
Installing the E5810
Getting Network Information
Getting Network Information
This section gives guidelines to get information about Enterprise and Local
networks, as applicable to your requirements.
Getting Enterprise Network Information
Before you connect the E5810 to an Enterprise (corporate) network, you will
need to get some network configuration and network addressing parameters
from the System Administrator in your Information Technology (IT)
department.
Copy the Network
Information Card
Contact Your
System
Administrator
Make a copy of the E5810 Network Information Card shown on the next
page. Then, enter the E5810 Serial Number and Ethernet (MAC) Hardware
Address on the card.The E5810 Serial Number and Ethernet (MAC)
Address are printed on a label on the underside of the E5810. See the
Glossary for descriptions of the items on the Network Information card.
Tell your system administrator you want to add a new device (the E5810) to
the network that will provide remote access for GPIB and RS-232
instruments and ask him/her to provide the applicable network information
on the
Number and Ethernet Address, tell the System Administrator about the
E5810 (default) information listed on the card.
E5810 Network Information Card. In addition to the E5810 Serial
Getting Local Network Information
For installation on a Local network, you will probably not need to contact
your IT department. However, you should have all the required network
information available, such as IP addresses, etc.
Where to Go Next
To Install the E5810 on a DHCP Enterprise Network:Go to “Installing
the E5810 on an Enterprise Network”.
To Install the E5810 on a Non-DHCP Enterprise Network:Go to
“Configuring the E5810 on a Local Network”.
To Install the E5810 on a Local Network:Go to “Configuring the E5810
on a Local Network”.
42Chapter 2
Page 43
Installing the E5810
Getting Network Information
E5810 LAN/GPIB Gateway for Windows Network Information
E5810 General Information (Completed by E5810 User)
(Serial Number and Ethernet (MAC) Hardware Address on label on underside of E5810)
Default Values (for IT Department): DHCP: Enabled at power-on
Hostname: No hostname configured
Universal Plug&Play: Enabled
Enterprise Network Information (Completed by System Administrator)
Does the Network Support DHCP? Yes ___ No ___
If No, provide: IP Address (Static): ______.______.______.______
Subnet Mask: ______.______.______.______
Gateway IP Address: ______.______.______.______
Does the Network Support Dynamic DNS? Yes ___ No ____
If Yes, provide: E5810 Hostname: __________________________
Does the Network Support DNS? Yes ___ No ____
If Yes, provide: DNS Server (IP Address): ______.______.______.______
Will You Allow Universal Plug&Play to be Enabled? Yes ___ No ____
Chapter 243
Page 44
Installing the E5810
Configuring the E5810 on a Local Network
Configuring the E5810 on a Local Network
This step gives guidelines to configure an E5810 on a Local network for
eventual operation in a non-DHCP Enterprise network or in a Local network
operation, including:
What is a Local Network?
Connecting the E5810 to a Local Network
Configuring the E5810 on a Local Network
NOTE
This step gives guidelines to configure your E5810 on a Local network
for eventual installation on an Enterprise network that
Dynamic Host Configuration Protocol (DHCP) OR for installation on a
Local network.
does not support
Local Network
(Hub/Switch)
Connections
Direct PC
(Crossover Cable)
Connections
If you plan to install the E5810 on an Enterprise network that
support
Enterprise Network”.
DHCP, skip this step and go to “Installing the E5810 on an
does
What is a Local Network?
A local (peer-to-peer) network is a network consisting of a computer with an
Ethernet port and an E5810 or a set of networking devices that are
networked together but are not connected to an Enterprise network. The
figure on the next page shows example configurations for Local networks
with hub/switch or crossover cable connections.
In a typical Local network (isolated LAN), a hub or switch may or may not act
as a Dynamic Host Configuration Protocol (DHCP) Server. For Local
Network connections, the E5810 is not visible on the Enterprise network. For
this configuration, multiple PCs can communicate with the E5810 via the hub
or switch.
For direct PC connection to the E5810, a crossover cable is connected from
the E5810 LAN port to a LAN card on the PC. There are no connections to
an Enterprise network. This setup is typically used for local configuration.
For this configuration, only a single PC can communicate with the E5810 via
the crossover cable.
44Chapter 2
Page 45
Installing the E5810
Configuring the E5810 on a Local Network
Local Network Connections (Multiple PCs can Communicate with the E5810)
LAN Patch
Cable
Typically Hub
or Switch
E5810
GPIB Instruments
LAN GPIB RS232
GPIB
To RS-232
Instrument
Direct PC Connection (Only One PC can Communicate with the E5810)
Crossover
Cable
E5810
LAN GPIB RS232
GPIB
GPIB
GPIB
GPIB Instruments
GPIB
Connect to
GPIB
PC LAN Card
To RS-232
GPIB
Instrument
GPIB
Chapter 245
Page 46
Installing the E5810
Configuring the E5810 on a Local Network
Connecting the E5810 to a Local Network
This section shows how to connect the E5810 to a Local network using an
Ethernet hub/switch or a crossover cable.
E5810 Hub/Switch
Connections
This figure shows typical E5810 Ethernet hub or switch connections. Since
the E5810 has no AC Power switch, the Mains disconnect for the E5810 is
to unplug the AC power cord from the AC outlet.
Typical Local Network Connections (Hub/Switch) (Two PCs)
Ethernet Hub/ Switch
1.Connect LAN patch
cables (do NOT use
crossover cables)
This figure shows typical E5810 connections using a crossover cable. Since
the E5810 has no AC Power switch, the Mains disconnect for the E5810 is
to unplug the AC power cord from the AC outlet. For this configuration, only
one PC can communicate with the E5810.
Crossover Cable
User-supplied crossover cable.
Do NOT use LAN "patch" cable.
Crossover cables swap Tx and Rx
lines to enable device communi cation without using a hub/switch.
1.Connect Crossover Cable
4.Connect to AC Power
2.Connect GPIB Cable
to GPIB Instrument(s)
Chapter 247
GPIB
GPIB
GPIB
3.Connect RS-232 Cable
to RS-232 Instrument
Page 48
Installing the E5810
Configuring the E5810 on a Local Network
Apply Power to the
E5810
After connecting the E5810 to a Local network, plug the E5810 AC power
cord into an AC outlet and observe the power-on sequence. When the
power-on sequence is complete, the default IP address of the E5810 is
displayed on the second line of the front panel display. A typical display
follows. See
Chapter 1 - E5810 Description for power-on sequences.
NOTE
Local networks may not have a DHCP Server. Since, by default, the
E5810 tries to find a DHCP server until a timeout value is reached, it may
require up to 75 seconds for the E5810 to display its default static IP
address (169.254.58.10).
NOTE
The E5810 detects duplicate IP addresses and will not start operation if
its IP address is already in use. If you try to simultaneously attach
multiple E5810s without changing each unit’s default static IP address,
some E5810s may not start operation.
To prevent this from happening, add a single E5810 at a time to the
network and configure each E5810 to a unique IP address before adding
additional E5810s.
IP Address and Hostname Displayed
Display shows IP address (and Hostname, if known)
Hostname
169.254.58.10
PowerFault
48Chapter 2
Activity
LAN GPIB RS232
E5810A
LAN/GPIB Gateway
Preset
Page 49
Installing the E5810
Configuring the E5810 on a Local Network
Configuring the E5810 for Local Network
Operation
This section gives guidelines to configure the E5810 on a Local network.
This section applies if you plan to configure the E5810 for eventual
installation on a non-DHCP Enterprise network or plan to configure the
E5810 for eventual use on the Local network.
NOTE
When configuring the E5810, we recommend you change the default IP
address to a unique IP address for each E5810 being added to the
system. Otherwise, since the E5810 detects duplicate IP addresses,
some E5810s added to the system may not operate. See Chapter 3 Using E5810 Web Access for details on setting E5810 parameters.
Establishing
Communication
With Your PC
Whether your Local network includes a hub/switch or a crossover cable, the
first step in configuring the E5810 is to establish communication between
your PC and the E5810. To do this, the PC and the E5810 must be on the
same subnet.
One way to put the PC and the E5810 on the same subnet is to use
route add <E5810 IP Address> <PC IP Address> from the
MS-DOS prompt. For example, if IP address of your PC is 155.139.103.152
and the E5810 IP address is 169.254.58.10 (the default), use one of the
following:
! route is lost when the PC is rebooted
route add 169.254.58.10 155.139.103.152
or
! route persists when the PC is rebooted
route -p add 169.254.58.10 155.139.103.152
After communication has been established, you can set any required
configuration parameters for the E5810 by using the E5810 Web access.
Chapter 249
Page 50
Installing the E5810
Configuring the E5810 on a Local Network
Configuring the
E5810 for Enterprise
Network Operation
You can check or set E5810 configuration parameters using the E5810 Web
access that is accessed from your Web browser (Internet Explorer 4.0 or
higher or Netscape Navigator 4.7 or higher). The steps to set E5810
configuration parameters are:
1Display the Welcome Page.From your Web browser address line, type
‘http://<E5810 IP Address>’, where <E5810 IP Address> is
the IP address displayed on the E5810 front panel display. Then, press
Enter key to display the E5810 Welcome page.
the
For example, if the default IP address of 169.254.58.10 is displayed on
the E5810 front panel, typing
browser address line and pressing
page. The following figure shows a typical display.
http://169.254.58.10 on your Web
Enter displays the E5810 Welcome
50Chapter 2
Page 51
Click this icon
Installing the E5810
Configuring the E5810 on a Local Network
2Display the Current Configuration Page. From the Welcome page, click
View & Modify Configuration icon to display the Current
the
Configuration of E5810 LAN/GPIB Gateway
page
3Display the Modify Configuration Page. From the Current Configuration
of E5810 LAN/GPIB Gateway
to display the
Password dialog box.
page, click the Modify Configuration button
Chapter 251
Page 52
Installing the E5810
Configuring the E5810 on a Local Network
If the default password (E5810) is being used, the password is
displayed as asterisks (*****). If not, type in the current password. Then,
click the
Gateway
Submit button to display the Configuring Your E5810 LAN/GPIB
page.
4Set E5810 for Enterprise Network Operation. To properly set E5810
configuration parameters for eventual use on an Enterprise network,
you may need to enter the following network values, as provided to you
by your System Administrator, on the
Gateway
page.
Configuring your E5810 LAN/GPIB
52Chapter 2
Page 53
IP Address Assignment
Enterprise Network Supports DHCP
Installing the E5810
Configuring the E5810 on a Local Network
Enterprise Network Does Not Support DHCP
No action required. The E5810 automatically
receives an IP address from the network
DHCP Server.
Hostname
Enterprise Network Supports DNS
If the network supports dynamic DNS, enter
the Hostname provided by the System
Administrator. Then, you can access the
E5810 from your Web browser by using the
Hostname.
If the network supports DNS, enter the DNS
Server IP Address provided by the System
Administrator.
Universal Plug and Play (UPnP)
UPnP Enabled is Allowed on Enterprise
Network
No action is required for the E5810. However,
if you want to see the E5810 in My Network
Places, you may need to enable UPnP on
your computer’s Operating System.
Click DHCP OFF and enter the values
provided by the System Administrator for
IP Address, Subnet Mask, and Default
Gateway IP Address.
Enterprise Network Does Not Support DNS
No action required. Hostnames are not
supported. Use only the IP address when
communicating with the E5810.
UPnP Enabled is Not Allowed on Enterprise
Network or You Do Not Want the E5810 to be
Displayed in My Network Places
Set Universal Plug and Play to OFF.
Chapter 253
Page 54
Installing the E5810
Configuring the E5810 on a Local Network
Example:
Configuring the
E5810
2. Click the Save button
to save changes
This example shows one way to set various E5810 parameters on the
Configuring your E5810 LAN/GPIB Gateway page,assuming the Enterprise
network to which the E5810 will be connected does not support DHCP or
DNS. Since the network does not support DNS, a Hostname cannot be used
for this E5810. In addition, it is assumed the network does not allow UPnP,
so Universal Plug and Play is set to OFF.
3. Click Reboot E5810 to reboot
and make changes effective
1. Set DHCP OFF
Enter New IP Address
Enter New Subnet Mask Value
Enter New Default Gateway IP Address
Leave DNS Server Address Blank
Leave Hostname Blank
Set Universal Plug and Play to OFF.
Configuring the
E5810 for Local
Network Operation
If you plan to install your E5810 on a Local network, use the Configuring
your E5810 LAN/GPIB Gateway
page to set the parameters applicable to your
Local network.
Where to go Next
To Install the E5810 on an Enterprise Network. Disconnect the E5810
from the Local network and go to “Installing the E5810 on an
Enterprise Network”.
To Use the E5810 on a Local Network. Leave the E5810 connected to
the Local network and go to “Verifying Instrument Communication”.
54Chapter 2
Page 55
Installing the E5810
Installing the E5810 on an Enterprise Network
Installing the E5810 on an Enterprise
Network
This step gives guidelines to install an E5810 on an Enterprise network.
NOTE
If your Enterprise network does not support Dynamic Host Configuration
Protocol (DHCP), you must first configure your E5810 on a Local network
as shown in “Configuring the E5810 on a Local Network” and then return
to this step to install the E5810 on the Enterprise network.
Connecting the E5810 to the Network
This figure shows typical E5810 connections to an Enterprise network. You
can connect up to 14 GPIB instruments and one RS-232 instrument to each
E5810. Make connections from the E5810 to the network and to GPIB and/
or RS-232 instruments as required
.
To Enterprise
To RS-232
NetworkInstrument
Typically Hub or
Switch
OR
LAN
Tx
Ln
E5810A
GP IB
LAN
Chapter 255
RS232
GPIB
To AC Power
POWER
!
GPIB Instruments
GPIB
GPIB
GPIB
Page 56
Installing the E5810
Installing the E5810 on an Enterprise Network
After connecting the E5810 to the Enterprise network, plug the E5810 AC
power cord into an AC outlet and observe the power-on sequence. When
the power-on sequence is complete, the assigned IP address of the E5810
is displayed on the second line of the front panel display. A typical display
follows. See
Chapter 1 - E5810 Description for power-on sequences.
NOTE
The Mains disconnect for the E5810 is to unplug the AC power cord from
the AC outlet. The E5810 has no AC Power switch.
IP Address and Hostname Displayed
Display shows IP address (and Hostname, if known)
E5810A
LAN/GPIB Gateway
Hostname
169.254.58.10
PowerFault
Activity
LAN GPIB RS232
Preset
Configuring the E5810 for Enterprise Network
Operation
After the E5810 is installed on the Enterprise network, you can check or set
(as required) E5810 configuration parameters using the E5810 Web access
that is accessed from your Web browser (Internet Explorer 4.0 or higher or
Netscape Navigator 4.7 or higher). The steps to set E5810 configuration
parameters are:
1Display the Welcome Page. To display the E5810 Welcome page, from
your Web browser address line, type
‘http://<E5810 IP Address>’, where <E5810 IP Address> is
the IP address displayed on the E5810 front panel display. Then, press
Enter key.
the
56Chapter 2
Page 57
Installing the E5810
Installing the E5810 on an Enterprise Network
For example, if the default IP address of 169.254.58.10 is displayed on
the E5810 front panel, typing http://169.254.58.10 on your Web
browser address line and pressing
Enter displays the E5810 Welcome
page. The following figure shows a typical display.
Chapter 257
Page 58
Click this icon
Installing the E5810
Installing the E5810 on an Enterprise Network
2Display the Current Configuration Page. from the Welcome page, click
View & Modify Configuration icon to display the Current
the
Configuration of E5810 LAN/GPIB Gateway
page
3Display the Modify Configuration Page. From the Current Configuration
of E5810 LAN/GPIB Gateway
to display the
Password dialog box.
page, click the Modify Configuration button
If the default password (E5810) is being used, the password is
displayed as asterisks (*****). If not, type in the current password. Then,
click the
Gateway
Submit button to display the Configuring Your E5810 LAN/GPIB
page.
58Chapter 2
Page 59
Installing the E5810
Installing the E5810 on an Enterprise Network
Chapter 259
Page 60
Hostname
Installing the E5810
Installing the E5810 on an Enterprise Network
4Set E5810 for DHCP Enterprise Network Operation. For an Enterprise
network that supports DHCP, the only values you may need to set are
the Hostname and Universal Plug and Play (UPnP) settings, as
provided to you by your System Administrator, on the
E5810 LAN/GPIB Gateway
page.
Configuring your
Enterprise Network Supports DNS
If the network supports dynamic DNS,
enter the Hostname provided by the System
Administrator. Then, you can access the
E5810 from your Web browser by using the
Hostname.
If the network supports DNS, enter the DNS
Server IP Address provided by the System
Administrator.
Universal Plug and Play (UPnP)
UPnP Enabled is Allowed on Enterprise
Network
No action is required for the E5810. However,
if you want to see the E5810 in My Network
Places, you may need to enable
UPnP on your computer’s Operating System.
Where to Go Next
Go to “Verifying Instrument Communication.”
Enterprise Network Does Not Support DNS
No action required. Hostnames are not
supported. Use only the IP address when
communicating with the E5810.
UPnP Enabled is Not Allowed on Enterprise
Network or You Do Not Want the E5810 to be
Displayed in My Network Places
Set Universal Plug and Play to OFF.
60Chapter 2
Page 61
Installing the E5810
Verifying Instrument Communication
Verifying Instrument Communication
The last step in installing and configuring the E5810 is to verify
communication from your PC to up to 14 connected GPIB instruments and/
or one RS-232 instrument via the E5810 Web access. See
Using E5810 Web Access
NOTE
Over the Web, you can interact with instruments via your Web browser.
To program instruments via the E5810 using an application language
such as C or Visual Basic, you must first install and configure the
Agilent IO Libraries Suite as shown in “Installing and Configuring the
Agilent IO Libraries Suite” on page 64.
for details.
Open the Instrument Page
You can verify instrument communication using the Find and Control
Instruments Connected to your E5810
page of the E5810 Web access.
Chapter 3 -
NOTE
Before opening the
page, be sure all connected instruments are plugged in and turned on.
On the address line of your Web browser type
Address>
shown on the front panel display). Then, press
page.
From the
Password dialog box. If the default password is being used, the
the
Password dialog box shows asterisks (*****). If not, type in the E5810
password. Click the
Instruments Connected to your E5810
Chapter 261
(where <E5810 IP Address> is the IP address of the E5810
Welcome page, click the Find&Query Instruments icon to display
Find and Control Instruments Connected to your E5810
http://<E5810 IP
Enter to display the Welcome
Submit button to display the Find and Control
page.
Page 62
Installing the E5810
Verifying Instrument Communication
Instrument Page Functions
From the Find and Control Instruments Connected to your E5810 page, you
can check instrument communication, send command/queries, and do other
functions.
Checking Instrument
Communication
Sending
Commands/Queries
Example: Querying
a DC Voltage Value
To check instrument communication, first select (highlight) the instrument to
be addressed by clicking the SICL Address in the
column. Then, depending on the instrument selected, you can use button
functions (device clear, *IDN?, etc.) to communicate with the instrument.
You can also send instrument-specific commands to applicable instruments
using the Instrument Command line and then clicking
Query. In addition, you can clear the display on the screen by clicking the
Clear History button, set the timeout value (in seconds) by typing in the
desired value in the
operations on instruments connected to the E5810 by clicking the
Pending Operations
For example, the figure on the next page shows one way to identify and
query the DC voltage value of a DMM instrument at SICL address gpib0,22.
Chapter 3 - Using E5810 Web Access for details
See
Timeout (sec) dialog box, and clear all pending
button.
Instruments Connected
Send, Receive, or
Clear
62Chapter 2
Page 63
2. Select Instrument at
SICL Address gpib0,22
Installing the E5810
Verifying Instrument Communication
3.Click the *IDN? button
to identify the instrument
4. Type command on
Instrument Command
line and then click
Query
1. Click the Find button (as required)
to display all connected instruments
Where to Go Next
If you want to program instruments from your PC. Go to
If you do not want to program instruments. This completes
Chapter 263
“Installing and Configuring the Agilent IO Libraries Suite” on
page 64.
the E5810 installation.
Page 64
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
Installing and Configuring the Agilent
IO Libraries Suite
This step gives guidelines to install Agilent IO Libraries Suite (version 14.0)
on a PC with Windows 98/2000/Me/XP, and to configure for VISA LAN
Client (remote interface) operation.
NOTE
If you only want to use your Web browser to access the E5810, and do
not want to program your instruments or to run application software that
requires the Agilent IO Libraries, skip this step.
NOTE
If you are using Windows NT, go to www.agilent.com/find/iolib
and download version M.01.01 of the Agilent IO Libraries. Follow the
instructions in the
for version M.01.01 to install and configure the software.
Guide
Agilent IO Libraries Installation and Configuration
Steps to Install the IO Libraries Suite
These steps show how to install the Agilent IO Libraries Suite with default
settings, and should be optimal for most applications. To install a custom
version of the libraries or to install the libraries using non-default settings,
see the
64Chapter 2
Agilent IO Libraries Suite Getting Started Guide.
NOTE
Each client PC used for VISA/VISA COM/SICL application development
must have a separate Agilent IO Libraries Suite license. To order a
separate Agilent IO Libraries Suite license, order Option AG6 or product
E2094N.
NOTE
You must have Administrator privileges to install the IO Libraries Suite
and to run the Connection Expert utility.
Page 65
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
Check for Installed
Agilent IO Libraries
Before you begin installation, check for previously installed Agilent
IO Libraries software. If a version of the Agilent IO Libraries or Agilent
IO Libraries Suite is installed on your PC, a blue IO icon may be displayed
on the Windows taskbar (on the lower right-hand side of the screen).
IO Libraries icon
IO Libraries Suite icon
If either IO icon is displayed, click the icon and click About Agilent
IO Control
greater. Note that Agilent IO Libraries Suite 14.0 was the revision
immediately following Agilent IO Libraries M.01.01, so you should
consider revision “14.0” to be a greater version number than “L” or
“M”.
to display the version. The version must be L.01.01 or
If the IO icon is not displayed, a version may still be installed. To
check this, click
Agilent IO Libraries Suite program group.
or
Start | Programs and look for the Agilent IO Libraries
If the Agilent IO Libraries program group is present, click Agilent IO
Libraries | IO Control
About Agilent IO Libraries Control to display the installed version
click
(must be L.01.01 or greater).
to display the IO icon. Then, click the icon and
Agilent IO Libraries Suite program group is present, click Agilent
If the
IO Libraries Suite | Utilities | IO Control
click the icon and click
installed version (must be 14.0 or greater).
About Agilent IO Control to display the
to display the IO icon. Then,
If neither the IO icon nor the Agilent IO Libraries/Agilent IO Libraries
Suite program group is displayed, then no Agilent IO Libraries are
installed and you can use the steps in this chapter or in the
IO Libraries Suite Getting Started Guide
to install the libraries.
Agilent
If the version of the Agilent IO Libraries is less than L.01.01, you
must install the newer version included on your
CD
to support the E5810.
Chapter 265
Automation-Ready
Page 66
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
If your version of the Agilent IO Libraries is at least L.01.01, but less
than the version on your
install the newer version to take advantage of new features and
greater ease of use of the more recent Agilent IO Libraries Suite.
Note that Agilent IO Libraries Suite 14.0 was the revision
immediately following Agilent IO Libraries M.01.01, so you should
consider revision “14.0” to be a greater version number than “L” or
“M”. Configuration instructions in this manual refer to Agilent
IO Libraries Suite 14.0.
Automation-Ready CD, you may want to
Installing Agilent
IO Libraries Suite
To install the Agilent IO Libraries Suite software,
1First, disconnect any USB instruments, USB/GPIB converters, and
FireWire-VXI interfaces that are connected to your PC.
2Insert the Automation-Ready CD into your CD-ROM drive. Wait a few
seconds for the
NOTE
If you do not have the Automation-Ready CD, go to
www.agilent.com/find/iolib to download the Agilent IO Libraries Suite.
3If the window does not appear automatically,
Agilent IO Libraries Suite 14.0 window to appear.
Click Start | Run...
Type <drive>:autorun\auto.exe, where <drive> is your
CD drive letter.
4When the Agilent IO Libraries Suite 14.0 window appears, follow the
directions in this window to install the Agilent IO Libraries Suite. (See
Agilent IO Libraries Getting Started Guide on your Automation-
the
Ready CD
troubleshooting information.)
5Go to “Configuring a Remote GPIB Interface” on page 67 to configure
GPIB instruments connected to your E5810.
Go to “Configuring a Remote Serial Interface” on page 69 if an RS-232
instrument is connected to your E5810.
for a full description of installation options and installation
and/or
66Chapter 2
Page 67
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
Configuring a Remote GPIB Interface
This section shows the steps to configure a remote GPIB interface, which
is a logical interface on the client PC that supports communication with GPIB
instruments on your E5810. If you do not have GPIB instruments connected
to your E5810, but do have an RS-232 instrument connected, skip this
section and go to “Configuring a Remote Serial Interface” on page 69.
1Click the Agilent IO Control icon (blue circled IO icon on the Windows
taskbar) and click
Expert utility’s main window.
2ClickAdd Interface on the Connection Expert toolbar.
3In the Manually Add an Interface dialog box, select Remote GPIB
interface
and click Add. The Remote GPIB Interface dialog will appear.
Agilent Connection Expertto display the Connection
4Specify the TCPIP interface that you wish to use to host this remote
interface, in the
is already configured on your system; by default, a LAN interface
Chapter 267
TCPIP interface ID: field. This must be an interface that
Page 68
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
named TCPIP0 is configured when you start or refresh Connection
Expert. To change timeouts and protocol properties for your remote
interface, you must change the properties of this TCPIP interface.
5If your E5810 is on a different subnet from your client PC, type the
hostname or IP address of the E5810 in the
Remote GPIB interface
dialog box. Change the value in the Interface name on remote host: field,
if necessary, to match the
E5810
Welcome page.
GPIB SICL Interface Name displayed on the
If your E5810 is on the same subnet as your client PC, click Find
Interfaces...
Find Now, select your E5810 from the list, and click OK to return to the
Remote GPIB interface dialog box.
. Then, in the Find Remote GPIB Interfaces dialog, click
6In the Remote GPIB interface dialog box, click Test connection to check
connectivity to your E5810. If the test is successful, you will see the
message
If you leave the check box labeled
to this interface
The interface was successfully opened.
Auto-discover instruments connected
checked, then when you click OK, Connection Expert
will search for GPIB instruments connected to your E5810 and will send
*IDN? (identification) query to each instrument found. You will then
a
see the new remote GPIB interface and any attached GPIB instruments
in the Connection Expert’s explorer view.
68Chapter 2
Page 69
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
Configuring a Remote Serial Interface
This section shows the steps to configure a remote serial interface, which
is a logical interface on the client PC that supports communication with
RS-232 instruments on your E5810. If you do not have an RS-232
instrument connected to your E5810, skip this section and go to the next
step, “Verifying Communication From Your PC” on page 72.
1Click the Agilent IO Control icon (blue circled IO icon on the Windows
taskbar) and click
Expert utility’s main window.
2ClickAdd Interface on the Connection Expert toolbar.
3In the Manually Add an Interface dialog box, select Remote RS-232 serial
interface
appear.
and click Add. The Remote RS-232 Serial Interface dialog will
Agilent Connection Expertto display the Connection
4Specify the TCPIP interface that you wish to use to host this remote
interface, in the
is already configured on your system; by default, a LAN interface
Chapter 269
TCPIP interface ID: field. This must be an interface that
Page 70
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
named TCPIP0 is configured when you start or refresh Connection
Expert. To change timeouts and protocol properties for your remote
interface, you must change the properties of this TCPIP interface.
5If your E5810 is on a different subnet from your client PC, type the
hostname or IP address of the E5810 in the
Interface
host:
displayed on the E5810
dialog box. Change the value in the Interface name on remote
field, if necessary, to match the RS-232 SICL Interface Name
Welcome page.
Remote RS-232 Serial
If your E5810 is on the same subnet as your client PC, click Find
Interfaces...
Find Now, select your E5810 from the list, and click OK to return to the
Remote RS-232 Serial Interface dialog box.
. Then, in the Find Remote ASRL Interfaces dialog, click
6In the Remote RS-232 Serial Interface dialog box, click Test connection to
check connectivity to your E5810. If the test is successful, you will see
the message
The interface was successfully opened. Click OK to close
the dialog box. You will see the new remote serial interface in the
Connection Expert’s explorer view.
7To establish communication with a serial instrument connected to your
E5810, you will need to add this instrument manually in Connection
Expert. (Connection Expert cannot auto-discover serial devices.) In the
70Chapter 2
Page 71
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
main Connection Expert window, click Add Instrument. In the Add
Instrument
added and click
Auto-identify this instrument checked if your instrument responds to the
*IDN? query, and click OK. The instrument will appear in the Connection
Expert’s explorer view, and if it responds to the
dialog box, select the remote serial interface that you just
OK. In the RS-232 Serial Instrument dialog box, leave
*IDN? query, its
identification information will appear in the properties pane.
Chapter 271
Page 72
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
Verifying Communication From Your PC
This section gives guidelines to communicate with and to program
connected GPIB and RS-232 instruments from your PC via the E5810,
including:
Using Interactive IO for Communication
Using Supported Programming Languages
NOTE
You can also communicate with (but not program) installed GPIB and/or
RS-232 instruments using the E5810 Web access, whether or not you
have installed and configured the Agilent IO Libraries Suite. See
Chapter 3 - Using E5810 Web Access for details.
Using Interactive IO
for Communication
Example: Using
Interactive IO
After the E5810 has been configured and you have connected your GPIB
and/or RS-232 instruments to the E5810, you can verify communication
between your PC and the instruments by using the Interactive IO utility or by
using VISA or SICL commands with supported programming languages.
This section shows one way to use Interactive IO to verify instrument
communication.
NOTE
Once your remote interface(s) and instrument(s) have been configured in
Connection Expert, if you can see them in the Connection Expert explorer
and see their IDN string information in the detail pane then
communication has been verified. Interactive IO allows you to manually
verify communication and send specific commands to your instrument.
To use Interactive IO to send a *IDN? (identification) query to an instrument:
1Select the instrument by clicking its icon in the Connection Expert
explorer view.
2Right-click the instrument and click Send Commands To This Instrument
to display the Interactive IO window. For information on Interactive IO,
including a list of common commands and their meanings, click
Help Topics
.
Help |
72Chapter 2
Page 73
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
3*IDN? is the default command. Click Send & Read to send the
identification query to the instrument and display its reply in the
Interactive IO window.
4To send other commands, click Commands> to select from a list of
common commands, or type a command into the
experience timeout errors for some commands, click
the timeout value.
Command: field. If you
Options to change
Applicable
Programming
Documents
Programming Instruments
You can program GPIB and RS-232 instruments via the E5810 using VISA,
VISA COM, or Agilent SICL to send instrument commands such as SCPI.
You can program in various languages/applications, including Visual Studio
.NET languages, Visual Basic, Visual C++, Agilent VEE, and National
Instruments LabVIEW.
For general programming guidelines, see the documentation for your
programming environment. You can also find programming examples using
various I/O libraries and instrument drivers in the instrument
After the E5810 is successfully installed and configured, it should act as a
transparent interface for programming GPIB and RS-232 instruments.
Chapter 273
User’s Guide.
Page 74
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
For information on programming using Agilent VISA, see the Agilent VISA
User’s Guide
IO Libraries Suite Online Help
programming with the Agilent IO Libraries.
. Also see the Agilent Connectivity Guide and Agilent
for further information and guidelines on
Addressing
Instruments using
VISA and Remote
IO Client
Addressing
Instruments using
VISA and TCPIP
Interface
Once you have created a remote GPIB or remote serial interface in
Connection Expert, you can use ordinary GPIB or serial addressing in your
VISA or VISA COM programs to address instruments on these interfaces.
The Remote IO Client software maps TCPIP address requests into
appropriate interface type (GPIB or ASRL) addresses; thus the IP address
and hostname of the E5810 do not appear in the instrument address. This
makes it possible to use existing programs written for GPIB or ASRL without
having to modify code.
See “Configuring a Remote GPIB Interface” on page 67 or “Configuring a
Remote Serial Interface” on page 69 to configure a remote GPIB or remote
serial interface. VISA programs can then use addresses such as
GPIB0::22::INSTR (for GPIB) or ASRL1::INSTR (for RS-232). Use
Although remote GPIB and remote serial interfaces are the most convenient
way to configure and program instruments on your E5810, you may choose
not to use them. For example, if you are using another vendor’s I/O software
rather than the Agilent IO Libraries Suite, your I/O software probably does
not support remote interface addressing. (At the time of this writing, only
Agilent software supports remote interface types.)
If you are not using remote interfaces, you will address your instruments as
TCPIP resources in VISA. These addresses include the IP address or
hostname of the E5810 as well as the SICL address of the device on the
E5810.
Use these addresses in your viOpen() call as follows. These examples
assume that the VISA interface ID of your TCPIP interface is “TCPIP0”. (You
can specify this interface ID with the Connection Expert utility; “TCPIP0” is
the default VISA ID for the default TCPIP interface.)
Installing and Configuring the Agilent IO Libraries Suite
Addressing
Instruments with
SICL
SICL addresses include the IP address or hostname of your E5810 as well
as the SICL address of the device on the E5810, and optionally the protocol
to be used. Some example addresses for SICL programs follow. These
examples assume that the SICL interface ID of your TCPIP interface is “lan”.
(You can specify this interface ID with the Connection Expert utility; “lan” is
the default SICL ID for the default TCPIP0 interface.)
At the time of this writing, National Instruments I/O software does not
support the SICL-LAN protocol, but only the VXI-11 protocol. Because
RS-232 instruments are only supported by SICL-LAN and not VXI-11,
you cannot use National Instruments I/O software to program an RS-232
instrument on your E5810.
Chapter 275
Page 76
Notes:
Installing the E5810
Installing and Configuring the Agilent IO Libraries Suite
76Chapter 2
Page 77
3
Using E5810 Web Access
Page 78
Using E5810 Web Access
This chapter gives guidelines on how to use E5810 Web access, including:
Opening Your Web Browser for E5810 Web Access
Using the Welcome Page
Viewing and Modifying Current Configuration
Finding and Querying Instruments
Other Web Access Functions
78Chapter 3
Page 79
Using E5810 Web Access
Opening Your Web Browser for E5810 Web Access
Opening Your Web Browser for E5810 Web
Access
Since the E5810 is Web-enabled, you can access and communicate with the
E5810 using your Web browser (Internet Explorer 4.0 or higher or Netscape
4.7 or higher).
To display the E5810
http://<E5810 IP Address> or http://<E5810 Hostname>
on the address line, where <E5810 IP Address> is the IP address of the
E5810 and
Then, press the
For example, assume the E5810 IP Address is 169.254.58.10 (the default
static IP address). Typing
displays the E5810
non-default IP address shown) follows. The
page. The banner and the Navigation Bar (Welcome Page, etc.) are a fixed
frame for each page. The text within each page scrolls (as necessary) to
display desired information.
<E5810 hostname> is the Hostname of the E5810 (if known).
Welcome page, open your Web browser and type
Enter key.
http://169.254.58.10 and pressing Enter
Welcome page. A typical Welcome page display (with a
Welcome page is the home
Chapter 379
Page 80
Using E5810 Web Access
Using the Welcome Page
Using the Welcome Page
This section shows the features of the E5810 Welcome page, including the
following items. A typical
Navigation Bar
E5810 Current Settings
E5810 Support Information Banner
E5810 Documentation Links
Welcome page display follows.
E5810 Support
Information
Navigation
Bar
E5810 Current
Settings
E5810 Documentation
80Chapter 3
Page 81
Using E5810 Web Access
Using the Welcome Page
Navigation Bar
Clicking the applicable icon on the Navigation Bar on the left side of the
page allows you to take the actions shown in the following figure.
Welcome Page
Displays the Welcome page.
View & Modify Configuration
Displays the
LAN/GPIB Gateway
can view current E5810 configuration parameters.
Clicking the Modify Configuration button on this
page displays the
LAN/GPIB Gateway page, from which you can
view and modify E5810 configuration.
Find & Query Instruments
First displays the Password
you enter the E5810 password and click Submit,
the
Find and Control Instruments Connected to
your E5810
From this page, you can interact with GPIB and
RS-232 instruments connected to the E5810.
Session Status
Displays the E5810 LAN/GPIB Gateway Status
page. From this page, you can view the current
Firmware Revision, LAN Speed at Reboot, Time
Since Reboot, and Connection Status.
Print Page
Current Configuration of E5810
page. From this page, you
Configuring your E5810
dialog box. After
page is displayed.
Prints the currently displayed page on your
default printer.
Help with this Page
Displays the Web page help for items on the
currently displayed page.
Chapter 381
Page 82
Using E5810 Web Access
Using the Welcome Page
E5810 Current Settings
The Current Settings part of the Welcome page displays some of the current
settings for the E5810. A typical display follows. See “E5810 Configuration
Parameter Descriptions” in this chapter for detailed descriptions.
Hostname
Internet domain name for the E5810 that may
be used to communicate with the E5810. The
Hostname is not a required configuration value.
IP Address
The E5810 IP Address. An IP address is a
32-bit numeric address expressed as four
numbers separated by periods (e.g.,
152.160.10.240).
Ethernet (MAC) Address
A unique address assigned by the manufacturer
for each Internet device. The Ethernet address
is on a label on the underside of the E5810.
GPIB SICL Interface Name
Each GPIB interface used by Agilent VISA
or SICL must have a SICL Interface Name.
For VXI-11 protocol, use "gpib0".
RS-232 SICL Interface Name
"COM1" is the default value. Client SICL
applications will use full SICL name of
"COM1,488".
Firmware Revision
Current firmware revision on this E5810.
See “Updating E5810 Firmware” for
information on upgrading E5810 firmware.
82Chapter 3
Serial Number
Unique serial number for this E5810, located
on a label on the underside of the E5810.
Page 83
E5810 Support Information
E5810 support information includes Support, Products, and Agilent Site as
listed on the banner on the top of the page.
NOTE
These links attempt to access the Agilent Web site. Depending on your
network configuration, these links may not be accessible (networkdependent message).
Support
Connects you to the Contact Us Web page.
From this page, you can find information about
selecting and purchasing products, technical
support, equipment service and repair, and
training on the Agilent Website.
Using E5810 Web Access
Using the Welcome Page
Products
Connects you to the E5810 Web page.
From this page, you can find product and
service information for the Agilent E5810
on the Agilent Website.
Agilent Site
Connects you to the Agilent Technologies
Web page. From this page, you can access
complete information about Agilent
Technologies from the Agilent Website.
Chapter 383
Page 84
Help
Using E5810 Web Access
Using the Welcome Page
E5810 Documentation
You can click Help to access a complete E5810 help system or click User’s
Guide
to display the E5810 LAN/GPIB Gateway for WindowsUser’s Guide.
Clicking
help system and allows you to access E5810 help.
This is different than clicking the Help with this Page
icon in that clicking Help provides you with access to
the entire Help system, while clicking the Help with
this Page icon only displays help for the active page.
User's Guide
Clicking User’s Guide displays an electronic (.pdf)
version of this E5810 User’s Guide. This link attempts
to access the Agilent website. Adobe Acrobat
Reader Version 3.0 or later is needed to view the guide.
Help displays the contents page of the E5810
84Chapter 3
Page 85
Using E5810 Web Access
Viewing and Modifying Configuration
Viewing and Modifying Configuration
This section shows how to view and modify (as required) the current
configuration of the E5810 using the
LAN/GPIB Gateway
and the Configuring your E5810 LAN/GPIB Gateway page.
Viewing E5810 Configuration
To begin modifying the E5810 current configuration, click the View & Modify
Configuration
Gateway
icon to display the Current Configuration of E5810 LAN/GPIB
page. A typical display of the page follows.
Current Configuration of E5810
Chapter 385
Page 86
Using E5810 Web Access
Viewing and Modifying Configuration
Modifying E5810 Configuration
To modify the current E5810 configuration, from the Current Configuration of
E5810 LAN/GPIB Gateway
top or the bottom of the page to display the
page, click the Modify Configuration button at the
Password dialog box.
Displaying the
Configuration Page
If the default password (E5810) is set as the current password, asterisks
(*****) appear in the window. In this case, just click the
display the
Configuring your E5810 LAN/GPIB Gateway page (see the figure
Submit button to
on the next page). If no asterisks appear, enter the current E5810 password
and then click the
Submit button.
NOTE
If you do not know the current E5810 password, you can temporarily
reset the password to the default (E5810) by pressing the
Preset button
on the front panel of the E5810.
When the
Configuring your E5810 LAN/GPIB Gateway page is displayed, you
can configure desired parameters by typing or selecting the new value in the
Edit Configuration column and then clicking the Save button and then the
Reboot E5810 button at the top or the bottom of the page. See the figure on
the next page for a typical display.
Although there are a few exceptions, most changes to configuration
parameters are not effective until the
Reboot E5810 button is clicked.
Save button is clicked and then the
86Chapter 3
Page 87
Using E5810 Web Access
Viewing and Modifying Configuration
Chapter 387
Page 88
Using E5810 Web Access
Viewing and Modifying Configuration
E5810 Configuration
Parameter
Descriptions
Parameter
[Default]
Default Gateway
[0.0.0.0]
Description
[Factory-Set]
An alphabetical listing of E5810 configuration parameter descriptions and
applicable default (factory-set) values follows. The E5810 uses the default
configuration values until you change any value and save/reboot. The
E5810 also uses the default values when you press and hold down the
Preset button for >10 seconds.
Description
This value is the IP address of the default subnet gateway that allows the
E5810 to communicate with systems that are not on the local subnet.
This is the default subnet gateway where packets are sent which are
destined for a device not on the local subnet, as determined by the
subnet mask setting. Only one default subnet gateway can be configured.
A value of
0.0.0.0indicates that no subnetting is to be done.
The default description consists of “E5810 LAN/GPIB Gateway” followed
by the Ethernet (MAC) address. The Ethernet address is printed on a
label on the underside of the E5810.
A typical description is:
00-30-D3-05-00-23 is the Ethernet address. The description is the “UPnP
Agilent E5810 00-30-D3-05-00-23, where
Friendly Name” of the E5810 that will automatically be displayed on
UPnP (Universal Plug and Play) enabled LAN hosts.
Domain Name
Server (DNS)
[0.0.0.0]
When the E5810 is connected to the LAN, it broadcasts its presence to
the network if UPnP is enabled. UPnP clients will then see this E5810 in
My Network Places, listed by this Description. A Friendly Name can be up
to 39 characters, including spaces.
A DNS Server is an Internet service that translates domain names into IP
addresses and vice-versa. Every time you use a domain name, a DNS
Server must translate the name into the corresponding IP address.
For example, the domain name
198.105.232.4. The DNS system has its own network. If one DNS Server
www.example.com might translate to
does not know how to translate a particular domain name, it asks another
DNS Server, etc. until the correct IP address is returned, if available.
88Chapter 3
Page 89
Using E5810 Web Access
Viewing and Modifying Configuration
Parameter
[Default]
Domain Name
Server (DNS)
(cont)
[0.0.0.0]
Description
A DNS Server is an Internet service that translates domain names into IP
addresses. Every time you use a domain name, a DNS server must
translate the name into the corresponding IP address. For example, the
domain name
www.example.com might translate to 198.105.232.4.
The DNS system is distributed. If one DNS server does not know how to
translate a particular domain name, it asks another DNS server, etc. until
the correct IP address is returned. If DHCP is used, a DHCP Server may
provide a DNS Server IP address to the E5810 (this is transparent to the
user). If the user configures a DNS Server, the E5810 will try to use that
Server first.
This parameter shows the IP address of the domain name Server. More
than one address may be listed on the
LAN/GPIB Gateway
page. Up to two of these values may have been
Current Configuration of the E5810
returned by the DHCP Server during startup. Only one static value can be
input on the
Configuring your E5810 LAN/GPIB Gateway page.
The DNS Server provides a Hostname, given an IP Address, for a LAN
device based on entries in its DNS lookup table. If DHCP is OFF and you
do not specify a DNS Server or if Dynamic DNS is not available on your
enterprise LAN and your IP Address is not in the DNS lookup table on the
DNS Server, your Hostname will be unknown and you must address the
E5810 only by its IP Address. The Hostname is not a required entry.
Dynamic Host
Configuration
Protocol (DHCP)
[ON]
DHCP is a protocol for assigning dynamic IP addresses to devices on a
network. DHCP supports a mix of static and dynamic IP addresses. The
two options for DHCP are ON (default) or OFF.
DHCP ON (Default): If DHCP is ON (the factory default setting), the E5810
will try to obtain an IP address from a DHCP Server. If this fails, the
E5810 will use its static IP address. If DHCP is ON and a DHCP Server is
found, the manually configured IP Address, Subnet Mask, and Default
Gateway parameters are not used by the E5810 during startup and thus
are not required settings.
use the static IP address that may be input in the
LAN/GPIB Gateway
Subnet Mask, and Default Gateway shown in the Configured Value column
If DHCP is OFF or unavailable, during startup the E5810 will
Configuring your E5810
page. In this case, the values for the IP Address,
of the page will be used during startup.
The individual Serial Number assigned at the factory for each E5810. The
Serial Number is printed on a label on the underside of the E5810 and
has the form US12345678.
This is the Media Access Control Address, also known as the link-level
address, the Ethernet (station) Address, the LANIC ID and Hardware
Address. This is a unique 48-bit address assigned by the manufacturer
for each Ethernet device. The address is usually 12 hexadecimal
characters, with colon or dash separators between every two characters,
such as “00:30:D3:05:00:23” or “00-30-D3-05-00-23”. The Ethernet
address is printed on a label on the underside of the E5810.
This value configures the GPIB bus address of the E5810. This address
is used when transfers are made on the GPIB bus. A SICL client
application can change this value by using the SICL function
IGPIBBUSADDR. The GPIB address value can be any number 0 through
30.
GPIB Logical Unit
[7]
GPIB SICL Interface
Name
[gpib0]
This value is the interface logical unit (LU) number of the GPIB interface
in the E5810. It may be used in an Agilent SICL client application’s
iopen
statement to uniquely identify the GPIB interface in the E5810. The GPIB
logical unit value can be any number
1 through 255.
This value is the symbolic name of the GPIB interface in the E5810. It is
used in a SICL client application’s
iopen operation to symbolically
reference the GPIB interface in the E5810. The maximum length of the
GPIB interface name is 15 characters. If VXI-11 (TCP/IP Instrument
Protocol) is used, the name must be
hpib7” may be used to more easily support legacy programs, if only
“
gpib<n>. The names “hpib” or
SICL/LAN protocols will be used.
90Chapter 3
Page 91
Using E5810 Web Access
Viewing and Modifying Configuration
Parameter
[Default]
Hostname
[None]
I/O Timeout
[120 sec]
Description
This value configures the internet domain name for the E5810.
Hostnames are useful when IP addresses are being assigned by a DHCP
Server, since the Hostname will not change despite DHCP Server
changes and device IP address changes.
If a Hostname is entered, the E5810 will try to register this name when it
boots. The E5810 can only register the Hostname if the network has
Dynamic DNS. If the network does not have Dynamic DNS, this value is
not used. Since you can always use the IP Address or the name (possibly
supplied by another name Server), the Hostname is not a required
configuration value.
You may enter up to 35 characters for the Hostname. The Hostname
must start with a letter and consists of upper and lower case letters and
digits and dashes. There is no default Hostname. If a Hostname is
displayed on the
Welcome page, it is a valid Hostname, since one was
found on the network through DNS.
This value sets the Server I/O timeout in seconds. It configures the E5810
to use an I/O timeout of the specified amount of seconds if the client
requests a timeout of infinity. If
0 is specified for this value and the client
requests an infinite timeout, the E5810 will use a timeout of infinity as
requested.
Setting the I/O timeout to0is NOT recommended, as this can result in the
E5810 waiting indefinitely for an I/O operation and effectively “hang” the
E5810.
This timeout value may be used to ensure that the E5810 does not wait
indefinitely for an I/O operation. It also allows the E5810 to detect certain
network events (such as when a client connection is dropped) that may
otherwise go undetected. If the E5810 detects such a condition, it will
release any resources, such as locks, associated with the client.
This value also allows the E5810 to detect certain network events, such
as when a client connection is dropped. If the E5810 detects such a
condition, it will release any resources, such as locks, associated with the
client. The factory default setting is 120 sec.
Chapter 391
Page 92
Using E5810 Web Access
Viewing and Modifying Configuration
Parameter
[Default]
IP Address
[169.254.58.10]
LAN Keepalive
[7200 sec]
Description
This value is the Internet Protocol (IP) address of the E5810. The IP
address is a required value and is used for all IP and TCP/IP
communications with the E5810. The IP address is represented in dotted
decimal notation (for example,
154.140.222.201). This number is assigned
by the System Administrator. The E5810 has a default static IP address
169.254.58.10.
of
LAN traffic to the E5810 will be routed by the IP Address or by using a
Hostname that may be provided by a DNS name Server which is mapped
to this IP Address. The current E5810 IP Address may have been
established in one of two ways:
The IP address was provided by a DHCP Server during startup
(dynamic IP address).
The IP address shown on the Current Configuration of the E5810
LAN/GPIB Gateway
169.254.58.10. If DHCP will not be used, the IP address should be
set for your network.
This value sets the LAN connect timeout in seconds. The E5810 may use
the TCP keepalive timer of the TCP/IP protocol stack to determine if a
client is still reachable. By specifying this configuration value, the E5810
turns on the keepalive timer when connecting to the client.
page was used. This was set at the factory to
After the specified time, if there has been no activity on the connection,
the E5810 sends keepalive probes to the client to determine if it is still
alive. After a specified amount of time, the connection will be marked as
down (“dropped”), and the E5810 will release any resources which were
allocated to the associated client.
A value of
0 means no timeout is set. Thus, the E5810 will wait forever
and no keepalive probes are sent. If this value is set, it is recommended
that the largest value be used which still meets the application’s need for
unreachable client detection.
Smaller LAN Keepalive values will generate more keepalive probes
(network traffic), using more of the available network bandwidth.
Allowable values are 0 and greater than or equal to 600 seconds (10
min). The factory default setting is 7200 sec (2 hrs).
92Chapter 3
Page 93
Using E5810 Web Access
Viewing and Modifying Configuration
Parameter
[Default]
Password
[E5810]
RS-232 Baud Rate
[9600]
Description
E5810 configuration and instrument control pages are passwordprotected against changes. To change from the default password (or any
password) to a new one, enter the current (old) password in the
Configured Value column and enter the new password in both boxes in
Edit Configuration column of the Configuring your E5810 LAN/GPIB
the
Gateway
page. The password is limited to 8 characters. The default
password is “E5810”.
You do not need to use a password for SICL or VISA programs with the
E5810 interface. This password will not prevent unauthorized personnel
from using your E5810, but it will prevent them from easily modifying its
setup or controlling instruments attached to it. If additional security is
desired, an isolated subnet is recommended.
Number of bits per second that are transmitted. Available baud rates for
the E5810 are 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and
115200. The RS-232 baud rate is the speed of data transmission and
reception on the RS-232 interface. The baud rate value is dependent on
the peripheral device you connect to the RS-232 port. Check the
documentation for your peripheral device to set this value.
RS-232 Bits
[8]
RS-232 Flow
Control
[NONE]
The number of bits that comprise a byte of data. Available number of bits
options are 5, 6, 7, or 8. This is the number of data bits in a character
frame in RS-232 serial data transmission. The value is dependent on the
peripheral device you connect to the RS-232 port. Check the
documentation for your peripheral device to set this value. Available
number of bits options for the E5810 are 5, 6, 7, or 8.
Flow control is the protocol used to pace data transmission over the
RS-232 serial connection. The flow control value is dependent on the
peripheral device you connect to the RS-232 port. Check the
documentation for your peripheral device to set this value. Available flow
control mechanisms for the E5810 are NONE, XON/XOFF, RTS/CTS,
and DTR/DSR.
Chapter 393
Page 94
Using E5810 Web Access
Viewing and Modifying Configuration
Parameter
[Default]
RS-232 Parity
[NONE]
RS-232 SICL
Interface Name
[COM1]
RS-232 SRQ
[RI]
Description
Parity is used by the RS-232 hardware to verify data transmission. The
Parity value is dependent on the peripheral device you connect to the
RS-232 port. Check the documentation for your peripheral device to set
this value. Available parity check options for the E5810 are NONE, ODD,
EVEN, SPACE and MARK.
This parameter is the symbolic name of the RS-232 Interface in the
E5810. It is used in an Agilent SICL
iopen operation to symbolically
reference the RS-232 interface in the E5810. It is also used in the
Remote RS-232 Serial Interface dialog (as
Interface name on remote Host)
when specifying an RS-232 device for Agilent VISA.
The RS-232 interface used by Agilent VISA or SICL must have a SICL
Interface Name. The maximum length of the RS-232 SICL Interface
Name is 15 characters.
Method used to request service from the RS-232 device. The SRQ Line is
the modem status line on the RS-232 interface that is monitored for
Service ReQuests (SRQs). Available SRQ options for the E5810 are RI,
DCD, DSR, and CTS.
RS-232 Stop Bits
[1]
Subnet Mask
[255.255.0.0]
A bit that indicates that a byte has just been transmitted. Every byte of
data is preceded by a start bit and followed by a stop bit. Available stop
bit options are 1 or 2. Stop Bits is the number of bits used to indicate the
end of a character frame in RS-232 serial data transmission.
The Stop Bits value is dependent on the peripheral device you connect to
the RS-232 port. Check the documentation for your peripheral device to
set this value. Available stop bit options for the E5810 are 1 or 2.
This value is used to enable the E5810 to determine if a client IP address
is on the same local subnet as the E5810. When a client IP address is on
a different subnet, all packets must be sent to a subnet gateway.
See the
Glossary for an example of a subnet.
94Chapter 3
Page 95
Using E5810 Web Access
Viewing and Modifying Configuration
Parameter
[Default]
Universal Plug &
Play (UPnP)
[ON]
Description
If Universal Plug & Play (UPnP) is enabled, a multicast message is
generated and sent about once an hour to the subnet. Enterprise
(corporate) networks will want to decide whether this additional traffic is
acceptable. By default, UPnP is NOT enabled on Windows XP or on
Windows Me. Check your Operating System instructions to enable UPnP.
Universal Plug and Play (UPnP) has two options: ON or OFF.
Option ON: The E5810 is configured as a UPnP device and
provides information to the network about itself via an XML
description when mounted to the network.
Option OFF: The E5810 is not UPnP capable and will not announce
its presence as a UPnP device when mounted to the network.
Chapter 395
Page 96
Using E5810 Web Access
Finding and Querying Instruments
Finding and Querying Instruments
This section shows how to find and query GPIB and/or RS-232 instruments
connected to your E5810 by using the
Connected to your E5810
page. This page is password-protected since you
can inadvertently interfere with running VISA/SICL applications if you query
an instrument at an inappropriate time.
This page allows you to quickly communicate with your GPIB and RS-232
instruments and can help you determine if the instrument side of the E5810
is working properly. You can also use this page to set up and take
measurements remotely by sending instrument commands.
Find and Control Instruments
Highlight to select
an instrument
Click the Find button to display
connected instruments. The first
time this page is opened, no
instruments are displayed.
Set instrument timeout
value in secon ds
Clear all pending operations
and expire all existing timeouts
on instruments connected to
the E5810.
Clear the
history display
Click Device Clear, *IDN?,
Read STB, or SYST:ERR?
History
Display
Enter command on
Instrument Comm and line
and then click Send,Receive, or Query
(sends and receives)
96Chapter 3
Page 97
Using E5810 Web Access
Finding and Querying Instruments
Finding Instruments
The Instruments Connected column of the page shows the GPIB and/or
RS-232 instruments connected to your E5810. This column shows the SICL
address for each instrument connected. The SICL address is required for
programmatically interacting with instruments via the E5810.
Using the Find
Button
Checking for
Connected
Instruments
To refresh the display or if instruments have been added/deleted, click the
Find button to display the current configuration. The Find command is
automatically run when the
E5810
page is opened and the correct password is provided. However, when
this page first opens, no instruments are displayed. Click the
display a current list of instruments that are powered up and connected to
the E5810.
After clicking the
below the button. In addition, the top item ("
whether or not you have a RS-232 instrument connected. All other devices
shown in the
GPIB instruments. If no GPIB instruments are found, a message to this
effect is displayed in the output text (History) area.
After using the Find button, if you do not see one or more of your connected
GPIB instruments in the list, try these steps:
1Check Cables. Make sure all GPIB instruments are connected via GPIB
cables to the E5810 GPIB port and the RS-232 instrument is connected
via an RS-232 cable to the E5810 RS-232 port.
2Turn Instrument Power ON. Make sure power is turned on for all
instruments. Then, click the
Connected
Find button, all GPIB equipment should appear in the box
Instruments Connected list box are the SICL addresses of your
column.
Find and Control Instruments Connected to your
Find button to
COM1,488") will always be listed
Find button at the bottom of the Instruments
3Check Hardware. A broken GPIB instrument may short out the GPIB
cable and cause all instruments to show a failure. If you are
experiencing problems, try connecting only one GPIB instrument to the
E5810 at a time. Possible causes of the problem may be broken cable,
loose connectors, two or more instruments at the same GPIB address,
an instrument may be broken, or the E5810 may be broken.
4Reboot the E5810. After checking hardware connections, reboot the
E5810 to do a self-test of E5810 hardware.
Chapter 397
Page 98
Using E5810 Web Access
Finding and Querying Instruments
Querying Instruments
After you have successfully found all connected instruments, you can use
Control Panel for Selected Instrument column of the page to interact with
the
the instruments. There are two ways to interact with connected instruments:
use the buttons at the top of the column or use the
at the bottom of the column.
NOTE
To program instruments using VISA, VISA COM, SICL, or Agilent VEE,
you must install and configure the Agilent IO Libraries Suite on your PC
(see Chapter 2 - Installing the E5810).
For VISA programming information, see the Agilent VISA User’s Guide. If
the Agilent IO Libraries Suite is installed, you can access an electronic
version of the manual by clicking the blue IO icon on the taskbar and then
clicking
menu also includes VISA COM and SICL information.
Documentation | VISA Users Guide. The same Documentation
Instrument Command line
Querying
Instruments Using
the Buttons
After highlighting the instrument to be addressed in the Instruments
Connected
actions for the device.
column, you can click the applicable button to perform these
Return the ID String for IEEE-488.2 compliant devices (*IDN?)
Clear the device (Device Clear)
Read the Status Byte for IEEE-488.2 compliant devices (Read STB)
Return a System Error for SCPI compliant devices (SYST:ERR?)
NOTE
These buttons will work only if the selected instrument supports
IEEE 488.2 and/or SCPI command sets.
In addition, you can clear the display on the screen by clicking the
History
value in the
instruments connected to the E5810 by clicking the
Operations
buttons and the
98Chapter 3
button, set the timeout value (in seconds) by typing in the desired
Timeout (sec) dialog box, or clear all pending operations on
Clear ALL Pending
button. The following table describes the actions of the six
Timeout (sec) dialog box.
Clear
Page 99
ButtonDescription
Using E5810 Web Access
Finding and Querying Instruments
*IDN?
Device Clear
Read STB
SYST:ERR?
Clear History
Clear ALL
Pending
Operations
Timeout
ID String.
Returns the ID string for the selected IEEE-488.2 compliant
instrument.
Device Clear.
impeded. This can occur for a wide variety of reasons. Sending a
Clear
to the instrument usually solves this problem and restores proper
Sometimes communication with an instrument may be
Device
communication with the instrument. If you encounter an error while doing a
Formatted I/O operation, you can send a
Device Clear to ensure proper
instrument communication is restored.
Read Status Byte.
Returns the decimal and hexadecimal value of the
IEEE-488.2 compliant instrument's Status Byte. Many instruments that
support Formatted I/O also have the ability to read the Status Byte. This
returns information on the status of the instrument, such as error status
and/or busy status. See your instrument manuals for status byte codes.
System Error.
Returns a SCPI system error for a SCPI compliant
instrument. A “0 No errors” return is sent to show no system errors.
Clear the Display
Clear All Pending Operations.
. Clears the (History) display of all previous queries.
Clears all pending operations on instruments
connected to the E5810. This operation expires all existing timeouts on all
devices connected to the E5810. Taking this action may affect other users
currently using the E5810. A password dialog box will appear that asks you
if you really want to do this action.
Change instrument Timeout.
A timeout value is used to limit the amount of
time for an I/O operation to complete. The I/O Timeout value, as set on the
Configuring your E5810 LAN/GPIB Gateway page, may not be long enough
for some instrument activities to complete. Setting a longer timeout here
tells the E5810 to wait a longer time for the instrument to finish.
As an alternative, doing a separate
Send and Receive may also work. Also,
if the configuration value is too long, you may force a shorter timeout here
for faster troubleshooting of instrument tests, etc. To set a different timeout,
enter a Timeout value in the
Timeout text box. This value is used for all
commands issued to an instrument from this page. The valid timeout range
is 1 to 60 seconds.
Chapter 399
Page 100
Using E5810 Web Access
Finding and Querying Instruments
Querying
Instruments Using
the Instrument
Command Line
Example: Using the
Instruments Page
For supported instruments, you can also query an instrument by first
highlighting the instrument in the Instruments Connected column, typing in a
SCPI command (such as
line, and then clicking
To send a command to the instrument without waiting for a response, click
Send button. Sending a string to the instrument does not return a result.
the
To receive a string from the instrument, click the
send the string and receive a response from the instrument, click the
button.
NOTE
The History display buffers up to 200 lines of information. At 200 lines,
the last lines are overwritten with new information. At this point, you may
want to press the
This figure shows an example history display after taking these steps:
1Selecting the instrument at SICL address gpib0,22
2Clicking the *IDN? and Read STB buttons
3Typing meas:volt:dc? on the Instrument Command Line
4Clicking the Query button
meas:volt:dc?) on the Instrument Command
Send and Receive, or Query.
Receive button. To both
Query
Clear History button.
100Chapter 3
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.