Optional 3rd and 4th 3.5" Non-Hot plug SATA or hot plug
SAS/SATA hard drive bays
6.
Optional DVD-RW or DVD-ROM drive
7.
Standard 1st and 2nd 3.5" Non-Hot plug SATA or hot plug
SAS/SATA hard drive bays (Small Form Factor drive cage
not shown here. See the Storage Section for orientation of
eight small form factor drive option)
Hot Plug Models - One available half-length/full height x16
PCI-Express Gen2 slot and one internal only PCI-Express
Gen2 slot (for internal storage controller - HP Smart Array
P410 Controller ONLY)
10.
Quad-Core Intel® Xeon® 5500 series processors (supports
up to two)
11.
Power supply (500 Watts - standard, other PS options
available)
Rear View:
1.
Power Supply Cable Socket
2.
Video Port
3.
Serial Port
4.
Rear USB ports (2)
5.
One GbE LAN ports for NIC 2 (RJ-45)
6.
Optional LO100i 10/100 Mbps LAN port for IPMI
management (RJ-45)
7.
Low-Profile slot cover (not used in this model)
8.
Full-height PCI-Express x16
9.
UID - Rear Unit Identification LED
10.
One GbE LAN ports for NIC 1 (RJ-45)
What's New
Support for SAS and SATA Hot Plug Midline and Enterprise Hard Drives
Support for 400W Hot Plug Redundant Power Supply Option Kit (some configuration restrictions apply)
At A Glance
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 1
QuickSpecs
HP ProLiant DL160 Generation 6
Overview
The HP ProLiant DL160 G6 server is a high performance, low cost, ultra-dense, dual processor capable, 1U rack server for memory
intense High Performance Computing (HPC) environments, Web 2.0, hosting, and general large memory footprint server
deployments.
Processors
Memory
Internal Drive Support
Network Controller
Storage Controllers
Expansion Slots
Infrastructure Management
:
Supports up to two Intel® Quad-Core 5500 sequence processors
:
Up to 192GB, using 16GB Quad-Rank PC3-8500R-7 DDR3 Registered (RDIMM) memory, operating at 800MHz when
populated at 2 DIMMs per Channel in 12 slots.
Up to 144GB, using PC3-10600R or PC3-8500R DDR3 Registered (RDIMM) memory, operating at 800MHz when
populated at 3 DIMMs per Channel in 18 slots.
Up to 24GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when populated at 2
DIMMs per Channel in 12 slots.
:
Support for up to four 3.5" Non-Hot plug serial ATA (SATA) hard drives or
NOTE:
Support for up to four 3.5" Hot plug Serial Attached SCSI (SAS) or SATA hard drives.
NOTE:
for Hot Plug models only.
Support for 2.5" Hot Plug Serial Attached SCSI (SAS) or SATA hard drives.
NOTE:
Hot Plug hard drives.
Internal storage capacity of up to 4.0TB (4 x 1TB Hot Plug 3.5" SATA/SAS), 3.0TB (4 x 750GB Non-Hot Plug SATA)
or 4.0TB (8 x 500GB Hot Plug 2.5" SATA/SAS)
HP NC362i Integrated Dual Port Gigabit Server Adapter
Non-Hot Plug SATA Models: HP Embedded SATA RAID Controller (RAID 0, 1, 10)
NOTE:
NOTE:
enable use of the B110i, enter the ROM Based Setup Utility (RBSU). The option for enabling RAID can be functionality
found in the Advanced section of the RBSU.
Hot Plug SAS/SATA Models: HP P410 Smart Array Controller RAID 0,1,10, 5
NOTE:
Non-Hot Plug Models: Up to two available PCI Express 2.0 slots:
Hot Plug Models: One available PCI-Express slot:
HP Insight Control suite for Linux (IC-Linux), a product option, delivers essential infrastructure management that can help
save time and money by making it easy to deploy, monitor, control and optimize your IT infrastructure through a single,
simple management console. The IC-Linux suite supports Linux-based servers and management consoles
HP ProLiant Onboard Administrator Powered Lights-Out 100i with optional LO100i Advanced Licenses for Virtual KVM
and Virtual Media.
The HP ProLiant Easy Set-up CDs and ISO image downloads offer Assisted and Manual single server installation, setup,
Embedded SATA controller support transfer rate up to 3Gb/s SATA.
Installation of the Hot Plug Backplane 1U 2S Kit (512181-B21) is required if ordering third or fourth Hard Drives
Installation of the HP 8SFF Hard Drive Cage & Backplane G6, FIO (515938-B21) is required if ordering 2.5"
:
:
Transfer rate: up to 3 Gb/s SATA.
To enable RAID functionality on Embedded SATA, use the HP Smart Array B110i SATA Raid controller. To
Slot 1: half-length/full-height PCI-Express 2.0 x16
Slot 2: low-profile internal only PCI-Express 2.0 x4 (x8 mechanically) - slot populated by the SAS/SATA storage
controller – HP Smart Array P410 Controller
:
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 2
QuickSpecs
Overview
and deployment capability. Capabilities provided are:
AutoRun
Assisted Installation Microsoft Windows 2003 Server and Microsoft Windows 2008 Server
OS and SW available for Manual Installation are listed on each servers' QuickSpecs
Ports
:
Five USB ports (two front, one internal, two rear)
NOTE:
USB header.
Optical Drive
Support for one (optional): DVD-ROM, DVD RW
Power Supply
500W Power Supply (Non-Hot Plug, Autoswitching)
Optional FIO high-efficiency pluggable power supplies: 460W Power Supply or 750W Power Supply
Optional FIO Hot Plug 400W G6 Redundant Power Supply. It includes the two power supplies as a part of the kit.
Additional Features
Support for NVIDIA Quadro FX3700 512MB PCIe x 16 graphics card
NOTE:
http://www.hp.com/go/accelerators
Form Factor
Rack (1U)
Operating Systems and Virtualization Software:
Supports Windows, RHEL, SLES, Solaris, VMware, and Citrix Essentials for XenServer (Retail)
Deployment/Serviceability
HP ProLiant DL160 G6 models have fixed rails which provide support for racks with round mounting holes and tool-free
support for racks with square mounting holes (including Compaq/HP 7000, 9000, 10000 and HP series), with an
adjustment range of 26" - 36"
Tool-less access to all system components for easy in rack serviceability
Customer Self Repair (CSR): HP products are designed with many CSR parts to minimize repair time and allow for
greater flexibility in performing defective parts replacement
Warranty
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP
Authorized Channel Partners. Hardware diagnostic support and parts replacement is available for three years from date
of purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to
warranty services are available through HP Care Pack services or customized service agreements. Hard drives have
either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.
NOTE:
information regarding worldwide limited warranty and technical support is available at:
NOTE:
NOTE:
Technology, with 4, 3, 2, and 1 cores active.
NOTE:
on the quantity and type of DIMMs installed.
NOTE:
performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise
Performance/Wattage (Mainstream); and "L" denotes Lower Wattage.
Available through Configure To Order only. See Factory Integration Models section for more
Available through Configure To Order only. See Factory Integration Models section for more
Available through Configure To Order only. See Factory Integration Models section for more
Available through Configure To Order only. See Factory Integration Models section for more
HT indicates that the processor model supports Intel® Hyper-Threading Technology.
Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost
DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend
For the Intel 5500 Series, the letter preceding the model number indicates the
(2 x 2 GB) UDIMMs
(3 x 2 GB) UDIMMs
(6 x 2 GB) RDIMMs
(12 x 16 GB)
(12 x 2 GB)
Network Controller
Expansion Slots #
1
2
***
HP NC362i Integrated Dual Port Gigabit Server Adapter
Technology
PCI-Express
2.0
PCI-Express
2.0
NOTE:
* Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.
** Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest Device ID
by bus (starting with the lowest bus).
***In order to access expansion slot #2, the low profile internal only slot, expansion slot #1 may only be
populated with a half length, full height form factor card.
All slots can accept universal keyed PCI cards
Bus Width
x16x16
x4x8
Connector
Width
*
Bus Number
10
63
*
Device
No.
**
Form Factor
Full length, full
height
Low Profile,
Internal Only
Notes
3.3 volts
3.3 volts
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 5
QuickSpecs
Standard Features
HP ProLiant DL160 Generation 6
Storage Controller
Storage
Non-Hot Plug SATA
Models
Hot Plug SATA/SAS
Models
NOTE:
drivers during a Windows operating system installation from a CD.
NOTE:
logical drive extension, RAID migration, and stripe size migration.
NOTE:
NOTE:
is only supported for external storage.
Diskette Drives
Optical Drives
Drive Bays
A diskette drive or virtual FDD using LO100 Advanced Pack is needed to install storage controller
Addition of the battery backed cache upgrade enables BBWC, RAID 5, 5+0, array expansion,
RAID 6 functionality requires the addition of Smart Array Advanced Pack (P/N: 516471-B21).
The addition of a Smart Array hardware based storage controller to a Non-Hot Plug SATA Model
HP Embedded SATA RAID Controller (integrated into the south-bridge)
supporting SW RAID 0,1,10
NOTE:
HP Smart Array B110i SATA RAID
NOTE:
download driver, hpahcisr.sys, is part of the 8.20 PSP, Smart Start, EZSetup
CD. For more information on SW Smart Array, go to:
www.hp.com/go/sataraid
HP Smart Array P410 Controller (RAID 0/1/1+0)
HP Smart Array P410 Controller 256 BBWC (RAID/0/1/1+0/5/5+0)
NOTE:
Via USB only
Optional SATA 9.5mm DVD-ROM Optical Drive
Optional SATA 9.5mm DVD RW Optical Drive
Up to 4 Non-hot plug SATA 3.5" drives
Up to 4 Hot plug SAS/SATA 3.5" drives
Transfer rate: up to 3 Gb/s SATA
To enable RAID for embedded SATA controller, use EZ set-up CD to
Transfer rate: up to 3 Gb/s SATA, up to 3 Gb/s SAS.
Maximum Internal Storage
Interfaces
Non-Hot Plug SATA
Hot Plug SATA
Hot Plug SAS
Parallel
Network RJ-45(Ethernet)
Serial
Pointing Device (Mouse)
Graphics
Keyboard
USB
3.0TB
4.0TB
4.0TB
None
2 10/100/1000 NIC ports (plus 1 optional dedicated port for the HP
ProLiant Lights Out 100i Remote Management)
1
0 (via USB only)
1
0 (via USB only)
5 (two front, one internal, two rear)
NOTE:
G6 Kit must be used (536769-B21)
NOTE:
support:
In order to connect a USB device internally, the internal USB Cable
Please see the following URL for additional information regarding USB
.
4 x 750GB
4 x 1TB
4 x 1TB
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 6
QuickSpecs
Standard Features
HP ProLiant DL160 Generation 6
Graphics
Form Factor
Embedded Systems
Management
32MB shared supporting all display resolutions up to 1600x1200 16bpp@75Hz
NOTE:
Rack (1U), (1.75 in/4.45 cm)
HP ProLiant Onboard
Administrator and LO100i
Advanced
8MB is dedicated to video memory.
HP ProLiant Onboard Administrator Powered by LO100i with Optional
LO100i Advanced Licenses for Virtual KVM and Virtual Media.
Features:
Embedded IPMI standard reporting
System event log access
Remote Serial console (serial redirection)
Browser, Telnet access
SMASH-CLP compliant
IPMI 2.0 compliant
Secure Socket Layer Encryption
Secure Shell Encryption
Virtual media (Floppy, CD, USB 2.0) with Advanced License
Virtual KVM with Advanced License
Core Infrastructure
Management
HP Insight Control for Linux
Insight Control server
deployment
NOTE:
HP Insight Control for Linux (IC-Linux), as a product option, delivers essential
lifecycle management that can help save time and money by integrating
discovery, server deployment, firmware updates & provisioning, health &
performance management, remote management, and virtualization. This
makes it easy to optimize your IT infrastructure through a single, simple
management console. The IC-Linux suite installs and licenses software modules
that are integrated into HP System Insight Manager (HP SIM).
HP Insight Control for Linux serves environments requiring a Linux-based
management console. See
HP Insight Control for Linux includes one year of 24 x 7 HP Software
Technical Support and Update Service ensuring rapid access to HP support
staff and proactive delivery of software updates. For more information about
this service, please visit:
HP Insight Control server deployment is a deployment solution for HP ProLiant
and Integrity servers hosted on a Windows CMS. It automates the process of
deploying and provisioning server software, enabling companies to quickly
and easily adapt to changing business demands. Insight Control server
deployment includes software optimizations for HP servers, including the HP
scripting toolkits, configuration jobs for leading industry-standard operating
systems, sample unattended files, and HP server support packs that include
software drivers, management agents, and important documentation.
Deploying servers can be accomplished either through imaging or through
scripting.
For more information, see:
www.hp.com/go/ic-linux
http://www.hp.com/services/insight
http://www.hp.com/go/lo100
.
Insight Control server deployment is hosted on a Windows server and is
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 7
QuickSpecs
Standard Features
HP ProLiant DL160 Generation 6
intended for heterogeneous environments deploying Windows, Linux,
VMware ESX and Microsoft Hyper-V systems.
Insight Control server deployment includes one year of 24 x 7 HP Software
Technical Support and Update Service ensuring rapid access to HP support
staff and proactive delivery of software updates. For more information about
this service, please visit:
http://www.hp.com/services/insight
.
Industry Standard
Compliance
Security
Security - Trusted Platform
Module
ACPI V2.0 Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Microsoft® Logo certifications
IPMI 2.0, SMASH CLP compliant
The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to
authenticate the server platform. These artifacts can include passwords, certificates and encryption keys.
Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature available in Windows
Server® 2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform Module (TPM)
version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running
Windows Server 2008 has not been tampered with while the system was offline.
NOTE:
NOTE:
NOTE:
the key could result in data loss.
For more information about TPM, including a white paper, go to:
ProLiant OS pre-installed units will come with the partition required for TPM deployment.
The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing
http://www.hp.com/go/TPM
Server Power Cords
UPS and PDU Power
Cord Matrix
One 6' Highline (IEC-IEC) power cord ships standard
NOTE:
allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected
to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a
user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the NEMA power cord
(227099-001) must be ordered separately.
If customers require a local power cord, they can check the power cord matrix for the appropriate cord.
Please see the following power cord matrix:
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under
Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements,
and specifications for UPS and PDU units. Please see the following link:
www.hp.com/products/powercords
HP ProLiant DL servers no longer ship standard with NEMA power cords (163719-002) that
http://www.hp.com/go/powercordmatrix
.
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
.
Page 8
QuickSpecs
Standard Features
HP ProLiant DL160 Generation 6
Power Supply
System Fans
Operating Systems and
Virtualization Software
Support for ProLiant
Servers
Rack Airflow Requirements
500 Watts, auto-switching, high efficiency, PFC (Power Factor Correcting)
NOTE:
6 system fans ship standard; Non-hot plug, N+1 Redundant Standard
Microsoft Windows Server
Microsoft Windows Server Hyper V
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Solaris 10 for x86/x64 based Systems
VMware
Citrix Essentials for XenServer (Retail)
NOTE:
Software and latest listing of software drivers available for your server, please visit our Support Matrix at:
Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for maximum
cooling, allowing these racks to be fully loaded with servers using the latest processors.
Factory upgradeable to high-efficiency (HE) pluggable or Hot Plug Redundant power supply.
For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization
and our driver download page
.
Rack Support
Telco Rack Support
CAUTION:
airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow
5,350 sq cm (830 square inches) of hole evenly distributed from top to bottom to permit adequate
airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be a
minimum of 7 cm (2.75 inches)
CAUTION:
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that
can lead to thermal damage.
NOTE:
provided with the server, or to the server documentation located in the Support section at the following
URL:
www.hp.com/servers/dl160
The DL Fixed Rail System supports installation in racks with square or round mounting holes (including
Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment range of 24" - 36".
Support for all 2 and threaded hole racks requires an additional option kit from Rack Solutions. The Rack
Solutions brackets can be purchased at:
If a third-party rack is used, observe the following additional requirements to ensure adequate
Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
For additional information, refer to the Setup and Installation Guide or the Documentation CD
.
www.racksolutions.com/hp
.
NOTE:
The 4 post Telco racks also supported.
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 9
QuickSpecs
Standard Features
HP ProLiant DL160 Generation 6
Factory Express Portfolio
for Servers and Storage
HP Enterprise Configurator
Service and Support
HP Factory Express offers configuration, customization, integration and deployment services for HP servers
and storage products. Customers can choose how their factory solutions are built, tested, integrated,
shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex
configuration and design services as well as individual factory services, such as image loading, asset
tagging, and custom packaging. HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000
servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network
switches.
For more information on Factory Express services for your specific server model please contact your sales
representative or go to:
The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware
portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our
valued customers. If you require "custom" rack configuration, please contact HP's Customer Business
Center or an Authorized Partner for assistance.
HP Care Pack Services provide total care and support expertise with committed response designed to
meet your IT and business needs.
http://www.hp.com/go/factory-express
.
HP Care Pack Services provide total care and support expertise with committed response designed to
meet your IT and business needs.
HP Care Pack services include coverage for the HP branded hardware options qualified for the server
that are purchased at the same time or afterward and internal to the enclosure. It also includes the 22"
and smaller external monitors and tower UPS options up to 3kVA. These items will be covered at the
same service level and for the same coverage period as the server. Coverage of UPS Battery is not
included and standard warranty terms & conditions apply. For servers or storage systems installed within a
rack, service also covers all HP qualified rack options installed within the same rack.
To fully capitalize on your HP ProLiant servers' capabilities requires a service partner who thoroughly
understands your server technology and systems environment. HP Services, an industry leader in provision
of multi vender support solutions provides a range of support services designed to meet the varying needs
of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help
you speedily deploy and maximize system uptime.
Recommended Service
Support Service
Deployment Service
Enhanced Service
- Simplify ProLiant solution implementation, maintenance and management.
- 3-Year 24x7 4 hr Response service support coverage
- Hardware Installation only
- Optimize service level to increase IT performance and availability
Support
Support
Support Plus
Installation of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data
Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays.
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
-3-Year 24x7 24 hr Call to repair service support coverage
- 3-Year 24x7 6 hr Call to repair service support coverage
-24x7 4 hr Response service support including OS coverage
Page 10
QuickSpecs
Standard Features
For a complete listing of service offerings and information visit:
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 11
QuickSpecs
HPC Interconnects
HP ProLiant DL160 Generation 6
NOTE:
product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters.
Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC
Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects:
HPC Interconnects
High Performance Computing (HPC) interconnect technologies are available for the DL160 G6 under the Cluster Platform
4MB shared L3 cache (E5504)
8MB shared L3 cache (L5520)
4GB (2 x 2GB) PC3-10600E (UDIMM)
HP NC362i Integrated Dual Port Gigabit Server Adapter
Embedded SATA RAID 0, 1, 10
HP 160GB 7.2k Non Hot Plug SATA
Up to 4 large form factor Non-Hot Plug drives
None ships standard
500W high efficiency multi-output supply (ships standard)
1U
Hot Plug Serial ATA (SATA)/ Serial Attached SCSI (SAS) Models
NOTE:
NOTE:
HP DL160G6 E5504 Hot
Plug
490442-xx1
HP DL160G6 E5520 Hot
Plug, 6GB
490454-xx1
HP DL160G6 X5550 Hot
Plug, 4LFF, 12GB, 2P
490455-xx1
Up to 4 large form factor hard drives supported in server model (P/N 490455-xx1).
Up to 2 large form factor hard drives supported in server models (P/N 490454-B21 and 490442-xx1).
4GB (2 x 2GB) PC3-10600E (UDIMM)
6GB (3 x 2GB) PC3-10600E (UDIMM)
12GB (6 x 2GB) PC3-10600R (RDIMM)
HP NC362i Integrated Dual Port Gigabit Server Adapter
HP Smart Array P410 SAS/SATA RAID 0,1,10
HP Smart Array P410/ 256MB BBWC RAID 0,1,10,5,50 (P/N 490455xx1)
None ship standard
Up to 4 large form factor Hot Plug drives
Up to 2 large form factor Hot Plug drives
None ship standard
500W high efficiency multi-output supply (ships standard)
1U
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 13
QuickSpecs
Models
HP ProLiant DL160 Generation 6
Country Code Key
xx = 00
xx = 20
xx = 29
xx = 37
xx = 42
xx = AA
U.S.
Brazil (ONLY P/N 490442-xx1)
Japan
APD
Euro
PRC
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 14
QuickSpecs
Configuration Information - Factory Integrated Models
HP ProLiant DL160 Generation 6
NOTE:
ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for additional information.
NOTE:
CTO Chassis.
NOTE:
This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are
HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a
FIO indicates that this option is a Factory Installable Option.
Step 1: Base Configuration (choose one of the following configurable models)
Non-Hot Plug SATA Model
NOTE:
NOTE:
only.
HP ProLiant DL160 G6 Non-Hot Plug SATA Rack CTO Chassis
Factory Integrated Model ships with:
HP NC362i Integrated Dual Port Gigabit Server Adapter
One available full-length/full-height PCI-Express x16 Generation 2 slot
One Highline IEC Power Cord
6 Non-Hot Plug Fans
Rack (1U), (1.75 in / 4.45 cm)
Tool-less Fixed Rails
Hot Plug Model
HP ProLiant DL160 G6 Hot Plug SAS/SATA Rack CTO Chassis
Factory Integrated Model ships with:
HP NC362i Integrated Dual Port Gigabit Server Adapter
One available PCI-Express Generation 2 slot:
Non-Hot Plug models are not upgradeable to Hot Plug.
The addition of a Smart Array controller is supported for external storage use
491531-B21
491532-B21
Slot 1: half-length/full-height
Slot 2: low-profile/half-height - occupied by HP Smart Array P410 Controller
One Highline IEC Power Cord
6 Non-Hot Plug Fans
Rack (1U), (1.75 in / 4.45 cm)
Tool-less Fixed Rails
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 15
Loading...
+ 35 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.