Automatic door opening system that will swing open the MCS front and rear doors in case of an unexpected change in temperature beyond the established parameters. 35kW of cooling capacity, up from 30kW. CTO capability of up to 2000 Lbs dynamic load. The MCS now ships standard with heavy duty Shock Pallet to support shipping the MCS integrated with IT equipment. Customers may now use the services of Factory Express or other integration services.
QuickSpecs
HP Modular Cooling System
HP Modular Cooling SystemHP Modular Cooling System
HP Modular Cooling System
Overview
DA - 12404 Worldwide — Version 8 — September 17, 2008
Page 1
At a Glance
At a GlanceAt a Glance
At a Glance
CTO capable with 2000 Lbs dynamic load capacity Automatic door opening system ships standard with every MCS. Theautomatic door opening mechanism is not CTO capable and therefore ships in the accessories box and is to be installed onsite. 35KW of cooling capacity for high density deployment of servers and blades. 42U rack height and 1.5 racks wide to maintain datacenter tiling configuration Ships pre-attached to HP 10642 G2 Series Rack, Environmental Monitor and control with SNMP integration to Systems Insight Manager (SIM) Hot swappable heat exchangers and fans. Power Input Redundancy for dual power source. Condensate Evacuation system to prevent condensation from entering air stream. 2750 CFM of chilled air placed in front of the servers and/or blades Site Preparation Guide available at
http://www.hp.com/go/MCS
QuickSpecs
HP Modular Cooling System
HP Modular Cooling SystemHP Modular Cooling System
HP Modular Cooling System
Overview
DA - 12404 Worldwide — Version 8 — September 17, 2008
Page 2
Site Preparation
Site PreparationSite Preparation
Site Preparation HP Modular Cooling System Water Hook-up Kit
AF079A
HP MCS Site Preparation Service
NOTE:
NOTE: NOTE:
NOTE:
Use Per Event Support and Consulting Service
http://h20219.www2.hp.com/services/cache/11077-0-0-225-121.aspx.
NOTE:
NOTE:NOTE:
NOTE:
The Modular Cooling System Water Hook-up kit can be ordered ahead of the MCS for site preparation purposes. The kit contains set of 1.25 inches (31.8mm) Quick-disconnect couplings, non-rust, Parallel and Parallel-to-Tapered adapter included to address regional differences.
Modular Cooling System (MCS)
Modular Cooling System (MCS)Modular Cooling System (MCS)
Modular Cooling System (MCS) HP Modular Cooling System (WW) CTO ready
AF098A
HP 10642 G2 Rack Rear Extension Kit
NOTE:
NOTE: NOTE:
NOTE:
Extension kit is required when racking p-Class Blade enclosure combined with Monitored PDU's.
AF058A
MCS Onsite Installation
NOTE:
NOTE: NOTE:
NOTE:
Install MCS per the product user installation manual. All MCS units ship with shock pallet for CTO.
UE005E
NOTE:
NOTE: NOTE:
NOTE:
The Rack Rear Extension kit is required when racking the HP c7000 Enclosure in conjunction with an HP
Monitored PDU. NOTE:
NOTE: NOTE:
NOTE:
The purchase of HP Modular Cooling System (P/N AF098A) includes 10642 G2 rack and MCS unit
attached. NOTE:
NOTE: NOTE:
NOTE:
A loaded MCS unit should only be moved by professional movers.