Hp 9000 Troubleshooting Guide for SCR+DMI

Troubleshooting Guide for SCR+DMI

HP 9000 Computers
Manufacturing Part Number: Not Assigned
August 2000
© Copyright 2000 Hewlett-Packard Company.

Legal Notices

The information contained in this document is subject to change without notice.
indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Warranty
A copy of the specific warranty terms applicable to your Hewlett-Packard product and replacement parts can be obtained from your local Sales and Service Office.
Restricted Rights Legend
Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in sub-paragraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause in DFARS 252.227-7013.
Hewlett-Packard Company 3000 Hanover Street Palo Alto, CA 94304 U.S.A. Rights for non-DOD U.S. Government Departments and Agencies are as set forth in FAR
52.227-19(c)(1,2). All rights reserved.
2

Troubleshooting SCR+DMI for HP-UX

1 Troubleshooting SCR+DMI
for HP-UX
This document describes steps you can take if SCR+DMI for HP-UX is not running properly.
Step 1. Ensure that DCE/RPC is running correctly on all the systems involved
Check for the necessary daemons, and restart them if necessary.
Run the command, ps –ef
The output should include the following daemons:
— For DCE on both the server and the client node(s):
root46 910 Sep 27 ? 1:5 1/opt/dce/sbin/rpcd
— For DMI on both the server and the client node:
root27 17310 Oc t 4 ? 4:2 1/usr/dmi/bin/dmisp root27 2410 Oct 4 ? 0 :35/usr/dmi/bin/hpuxci root27 19510 Oc t 4 ? 2:1 8/usr/dmi/bin/swci
— For SCR on the server:
root73 7310 16: 23:52 ?0:00/opt/scr/l bin/scrd aemon
Check that you have the required software and patches. Refer to the README for the release of HP-UX you are working with. The patches assume a base level of the HP-UX Applications Release distributed 7 June, 1999.
IMPORTANT The DCE patches must be loaded in numerical order.
Step 2. Verify entries in the file /var/dmi/dmiMach ines. This must be done on each client and
on the server.
A hostname or an IP address can be used for each machine (each network card in a machine needs to be listed) in the file.
On each client, the file must include an entry for each network card on the client and each network card on the server.
On the server, the file must contain an entry for each network card on the server and each network card on each client.
Chapter 1
Step 3. Verify that DMI is working on both the server and all clients. If any of the following four
steps fail, DMI is not working correctly. SCR cannot work correctly if DMI is not working correctly.
1. Launch the DMI browser by executing /usr/dmi/bin/ browser
5
Troubleshooting SCR+DMI for HP-UX
A task dialog labeled “MIF Browser” will be launched. An icon with the system name should be in the dialog.
2. Double-click on the icon with the system name.
The contents of the dialog should be replaced with three icons labeled:
HP-UX Standard Groups Definition
HP-UX Installed Software Definition
3. Double-click on the HP-UX Standard Groups Definition icon. Multiple icons should be
displayed with labels including:
Operating System
Host System
4. Check SCR on the server.
DMI 2.0 Service Provider
General Information
Run /opt/scr/bin/scrstatus
The output will list a time, a node name, the status on that node and details. Possible results include the following:
Table 1-1 Status Values
Status Detail What this means
Completed - SCR worked correctly on this node at this time
Executing - SCR is currently collecting data on this node.
Scheduled - SCR is set to collect data from this node at the
Warning or Error
time listed under the “Time” column.
Tmout Timeout. Possible problems include:
- DCE/RPC problem
- Network problem You can increase the timeout value with the /opt/scr/bin/scrconfig command. HP recommends a value of 10 minutes, and even more time may be required if your network slows down.
AcErr Access Error. This means SCR could not collect
data from the client. Potential problems are:
- The DMI daemons are not running (either on the server or the client),
- The server IP address is not in the /var/dmi/dmiMachines file on the client,
- The network is not working.
6
Chapter 1
Table 1-1 Status Values (Continued)
Status Detail What this means
RtErr Runtime Error. Potential problems include:
- file system full,
- no memory,
- no more processes.
Troubleshooting SCR+DMI for HP-UX
Chapter 1
7
Troubleshooting SCR+DMI for HP-UX
8
Chapter 1