Single input power distribution units with a unique modular design architecture
•
Up to 32 outlet receptacles
•
Zero-U/1U dense rack form factor
•
Easily accessible outlet receptacles and improved cable management
•
Models range from 16A-40A
hp Modular Power Distribution Units
(Zero-U/1U Modular PDUs)
DA-11041World Wide — Version 3 — December 11, 20021
hp Modular Power Distribution Units
A
QuickSpecs
OVER VIEW
Modular PDUs have a unique modular architecture designed specifically for the dense data center customers who want to maximize their power
distribution and space efficiencies in the rack. This new modular design consists of two main building blocks, the Control Unit and the Extension Bar(s).
Available in 16A-40A current ratings, each unit comes with one Control Unit and up to four Extension Bars, offering up to 32 outlet receptacles (the 16A
model has two Extension Bars, and offers 16 outlets).Providing easy accessibility and reduced cable clutter, the Modular PDUs offer you the flexibility to
easily mount your units in several different locations within the rack, without having to sacrifice valuable rack U-space.
KEY FEATURES
•
Unique modular design architecture
•
Small form factor with flexible mounting options
•
Up to 32 outlet receptacles
•
Easy installation
•
Consolidate and maximize cord management
•
Easily accessible outlets
•
Current ratings from 16A to 40A
PR ODUCT HIGHLIGHTS
Unique Modular Design Architecture
Modular PDUs have a unique modular design architecture. This “Building block” concept consists of two main parts, the Control Unit, and the Extension
Bar(s). The 24-40A mPDUs ship with one Control Unit and 4 Extension Bars. Each Control Unit is a single-phase unit that branches out into 4 singlephase branch circuits. The Extension Bars can be plugged into the Control Unit, and can be mounted directly to the rack frame, spanning the entire length
of the rack.
Note: The new 16A Modular PDU model ships with one Control Unit (with 2 branch circuits) and two Extension Bars. This is the only model in the Modular
PDU family that has a detachable input power cord, allowing for increased flexibility, ease of use, and adaptability for country specific requirements.
The 24A and 32AmPDU models come with an attached input power cord, due to regulatory requirements for higher amperage devices. And the 40
model has to be field wired. Higher amperage mPDUs offer more outlets, allow more equipment to be connected, and are especially suited to the
high-density server deployments.
(Zero-U/1U Modular PDUs)
Small Form Factor and Flexible Mounting Options
The Control Unit is zero-U or 1U rack mountable. And the Extension Bars mount directly to the rack-frame or the rack extension unit. With each Modular
PDU, you can get up to 32 outlet receptacles (except for the 16A and 40A models) in zero-U of rack space. And if you plan to mount two Modular PDUs in
one rack (typical configuration), you could get up to 64 output receptacles, without having to use any rack U-space.
Up to 32 Outlet Receptacles
Modular PDUs offer up to 32 outlet receptacles. Meaning, customers can plug-in as many as 32 power cords into one Modular PDU set. And if they were
to mount two such PDU sets, they have a total of 64 outlets! That means the Modular PDUs can support anywhere from a couple of servers in a rack to
up to 42 1U servers (IMPORTANT: Provided the total current load does not exceed the maximum allowable current draw of the PDU. To calculate server
current draw, please refer the Proliant Power calculator on ActiveAnswers System Configurator tool).
Note: The 16A model has 16 outlets and the 40A model has 28 outlets, while the other models have 32 outlets.
Easy Installation
The installation process is quick and easy. Whether you choose to mount the Modular PDU in zero-U or 1U, all required mounting brackets, accessories,
and installation instructions are shipped with the product. The Extension Bars come with easy to use, snap-in brackets, which fit directly into the rack
frame of a HP 9000 and 10000 Series racks.
Note: Modular PDUs may be installed in most third-party racks in a 1U configuration (no zero-U mounting). To mount the Extension Bars in a rack other
than the HP 9000 and 10000 series racks, an optional kit PN 310777-B21 is offered. This kit allows mounting the Extension Bars in most third party
racks that use a standard EIA19″ vertical rail.
DA-11041World Wide — Version 3 — December 11, 20022
QuickSpecs
hp Modular Power Distribution Units
(Zero-U/1U Modular PDUs)
PR ODUCT HIGHLIGHTS
Consolidate and Maximize Cord Management
When you have the power to choose where to mount the Extension Bars, you have the option of mounting the bars closer to where your specific servers
are located; so you don’t have to use long power cords running down the entire length of your rack – you can now get smaller cords plugging-in to a
nearby Extension Bar.
Shorter jumper cords (4.5ft) are offered as optional kits (PN 142257-006, quantity 1; PN 142257-007, quantity 15).
high voltage model of the mPDU. Additional shorter cords, if needed, have to be ordered (typically most devices ship with a 12ft – 8ft long jumper cord).
For more information on IEC320 -C14 to IEC 320 -C13 jumper cords, please refer the PDU cable section at the end of this document.
For low voltage applications (100 – 127V), typically most devices ship with a NEMA 5-15 cable (which plugs-into the NEMA 5-15R outlets on the low volt
Extension Bar). However, some devices with IEC320-C13 inlet may not ship with a NEMA cable. In such cases, a cable IEC320-C14 to NEMA 5-15P (PN
e7743a) will have to be ordered.
Easily Accessible Outlet Receptacles
Because you have the flexibility to decide how you want to configure your Modular PDU, you can now choose to mount the Extension Bars such that the
outlet receptacles are easily accessible, allowing you to easily plug-in and plug-out devices.
Current Ratings from 16A to 40A
Modular PDUs are available in a wide range, including four high volt models ranging from 16A to 40A current ratings; and one low voltage 24A model.
Compatibility
Ideal for use with the HP 9000 and 10000 Series Racks, the Modular PDUs are largely designed for the dense rack environment. These Modul a r PDUs
connect directly to the facility input power.
In addition, the low voltage model also connects to the low voltage UPS R3000 XR. The 40A model may be hardwired to a UPS as well. And the recently
announced 16A high voltage model will also connect to the high voltage UPS models of the R3000 XR and R6000.
Note: Control unit of the Modular PDUs may be mounted in a 1U configuration in most standard racks. To mount the Extension Bars in a rack other than
the HP 9000 and 10000 series racks, an optional kit PN 310777-B21 is offered. This kit allows mounting the Extension Bars in most third party racks
which use a standard EIA19″ vertical rail.
(continued)
Two short jumper cords ship with every
SER VICE & SUPPORT, CAREPAQ AND WA RRANTY INFORMAT ION
Warranty Upgrade Options
HP Modular PDUs are backed by a limited 3-year warranty.
When used in the HP 9000 and 10000 Series Racks, HP PDUs assume the warranty of theHP Rack in which they’re installed. HP CarePaq services
bought for the HP Rack also extend towards the HP Modular PDU if it is being used inside the HP rack.
FM-CBXHW-36 – 9x5 Next-Business-Day On-Site Coverage, 3 Years
FM-CB4HR-36 – 9x5 4-Hour Response On-Site Coverage, 3 Years
FM-CB724-36 – 24x7, 4-Hour Response On-Site Coverage, 3 Years
CarePaq Information
For CarePaq (hardware & software) information, as well as orderable part numbers, please refer to the URL listed below:
http://www.compaq.com/services/carepaq/index.html
DA-11041World Wide — Version 3 — December 11, 20023
QuickSpecs
HP MODULAR PDU SPECIFICATIONS
Mechanical Dimensions (WxHxD)17.5 x 1.62 x 5.6 in/44.45 x 4.11 x 14.22 cm
Unit Weight18 lb/8.16 kg
Shipping Dimensions (WxHxD)21.5 x 12.25 x 13.0 in/54.61 x 31.12 x 33.02 cm
Shipping Weight20.2 lb/9.16 kg
Operating Temperature
Operating Relative Humidity (%)10% to 90%
Operating Elevation0 to 10,000 ft/0 to 3048 m
Storage Temperature–4° to 140°F/–20° to 60°C
Storage Relative Humidity (% )5% to 95%
Storage Elevation0 to 30,000 ft/0 to 9144 m
Conformance StandardsUL, CUL, CE, NOM, D - 16A and 40A models
Kit Contents
50° to 122°F/10° to 50°C
UL, CUL, NOM – 24A High and Low voltage models
CE, D - 32A model
24-40A Modular PDUs ship with x1 Control Unit and x4 Extension Bars
16A Modular PDU ship with x1 Control Unit and x2 Extension Bars
All models ship with:
0U/1U Mounting brackets/hardware for Control Unit
Mounting brackets for Extension Bars
Cord Retention bracket for the Control Unit
Tie wraps
Install Card
High voltage models ship with two 10A, IEC320 -C14 to IEC 320 -C13 jumper cables, each 4.5ft/1.37m long. In
addition, the 16A model ships with one 16A, IEC 320-C19 to IEC 320-C20 jumper cord, 8.2ft/2.5m long.
hp Modular Power Distribution Units
(Zero-U/1U Modular PDUs)
DA-11041World Wide — Version 3 — December 11, 20024
hp Modular Power Distribution Units
QuickSpecs
ADD ITIONAL SPECIFICATIONS
Low Voltage 24A
(NA/JPN/LA)
Part Number252663-D71252663-B24252663-D72252663-B31252663-B21
Current (max)24A16A24A32A40A
AC Voltage Range100-127V200-240V200-240V200-240V200-240V
Frequency (Hertz)50/60Hz50/60Hz50/60Hz50/60Hz50/60Hz
Load Capacity (VA)2880 (@120V)3680 (@230V)4992 (@208V)7360 (@230V9200 (@230V)
Output Circuit
Breakers
Overload ProtectionYesYesYesYesYes
Indicator LightsIndicator light on each of the Extension Bars; and a main AC pilot light on the Control Unit
Plugs and Cables
Control Unit (x1)
Note: Manual ON/Off control provided for each load group; switch guards provided to prevent inadvertent power Off. The Control unit for the 16A model
has 2 outputs while the Control Unit for all other Modular PDUs has 4 outputs. The Extension Bars plug directly into the output-ends of the Control
Unit.
Extension Bars (x4)*
*Except for the 16A
model, which has 2
Extension Bars
4x15A2X10A4x15A4x15A4x15A
Input: 3.6m attached
cable with L5-30P
Output: Four IEC320C19 (12A ea)
Input: 2m attached
cord with IEC320-C20
Output: Each Bar has
8 NEMA 5-15 outlets
(12A max per outlet,
12A max per Bar)
High Voltage 16A
(WW)
Input: Detachable
input power cord
(country specific) with
a IEC 320-C20 inlet
Output: Two IEC320C19 (8A ea)
Input: 2m attached
cord with IEC320- C20
Output: Each Bar has
8 C13 outlets
(10A max per outlet,
12A max per Bar)
High Voltage 24A
(NA/JPN/LA)
Input: 3.6m attached
cable with L6-30P
Output: Four IEC320C19 (12A ea)
Input: 2m attached
cord with IEC320- C20
Output: Each Bar has
8 C13 outlets
(10A max per outlet,
12A max per Bar)
(Zero-U/1U Modular PDUs)
High Voltage 32A
(INTL)
Input: 3.6m attached
cable with IEC309-32A
Output: Four IEC320C19 (12A ea)
Input: 2m attached
cord with IEC320- C20
Output: Each Bar has
8 C13 outlets
(10A max per outlet,
12A max per Bar)
High Voltage 40A
(WW)
Input: Hardwire
Output: Four IEC320-
C19 (12A ea)
Input: 2m attached
cord with IEC320- C20
Output: 3 Bars each
with 8 C13 (10A max
per outlet, 12A max
per Bar); 1 Bar with 4
C19 (12A max per
outlet, 12A max per
Bar)
DA-11041World Wide — Version 3 — December 11, 20025
hp Modular Power Distribution Units
QuickSpecs
MODULAR PDU FAMILY INFORMAT ION
MODEL SELECTION MATRIX
Low Voltage 24AHigh Voltage 16AHigh Voltage 24AHigh Voltage 32AHigh Voltage 40A
Part Number252663-D71252663-B24252663-D72252663-B31252663-B21
Input Connection
(Single Input)
Output Connections (32) NEMA 5-15R
Applications
NEMA L5-30PDetachable input power
cord with a IEC 320-C20
inlet
The 16A model with
Note:
the detachable cord can be
used only in applicat i ons
where the total leakage
current is less than 3.5 mA.
Note: The low volt Extension
Bars w/5-15 outlets shoul d
be used ONLY with the low
volt Control Unit that is
shipped with the low volt
Modular PDU uni t.
Connects to low voltage
models of the UPS R3000
XR (and may also be
connected directly into
the facility input)
(16) IEC 320 C-13
The 16A model ships
Note:
with 2 Extension Bars, while
all other 24-40A models shi p
with 4 Extension Bars.
Connects to the high
voltage models of the
UPS R3000 XR and
R6000
Except for the UP S
Note:
R3000 XR, Nor th America
high volt model, where an
additional c able option kit,
PN 340653-00 1 (IEC320C19 to L6-20P), is needed to
connect a 16A mPDU to the
NA high voltage model of the
UPS R3000 XR
Hardwiring needs to be done
by a certified on-site
electrician in accordance with
the local electrical installation
into the facility
codes.)
input or to a high voltage
UPS (R12000 XR)
Also connects directly into
the facility input
You need to purchase
Note:
a cable PN 340653-001
(IEC320-C19 to L6-20P) for
North Americ a. Other countr y
specific cables are managed
at the country level.
DA-11041World Wide — Version 3 — December 11, 20026
hp Modular Power Distribution Units
2
2
2
2
QuickSpecs
ADD ITIONAL PDU CABLES AVAILABLE
Product Part NumberDescription
142257-0028 ft/2.5 m, x1
142257-00310 ft/3.0 m, x1
142257-0064.5 ft/1.37 m, x1
142257-0074.5 ft/1.37 m, x15
01493-001High Volt, Y-cable for NA/LA, x1
01493-002High Volt, Y-cables for NA/LA, x20
01493-B21High Volt, Y-cable for INTL, x1
01493-B22High Volt, Y-cables for INTL, x20
Please refer to the Power Cord Matrix for more information on power cords/cable part numbers, input/output descriptions.
Hewlett-Packard shall not be liable for technical or editorial errors or omissions contained herein. The information is provided "as is" without warranty of any
kind and is subject to change without notice. The warranties for Hewlett-Packard products are set forth in the express limited warranty statements
accompanying such products. Nothing herein should be construed as constituting an additional warranty.
10A, IEC320 -C14 to IEC 320 -C13 cables for connecting devices to the
power distribution unit.
Remote Insight Lights-Out Edition (RILOE) power Y-cable has been
designed for plugging into HP PDUs. One single Y-cable supports two
RILOE cards, which reduces the number of plugs required on the PDU for
connecting the RILOE cards.
(Zero-U/1U Modular PDUs)
DA-11041World Wide — Version 3 — December 11, 20027