Hovertech HM-MINI34DC, HM28DC, HM34SPU-LNK-B, HM50DC, HM39SPU-HLF User Manual

...
Air Transfer System
User Manual
TABLE OF CONTENTS
Symbol Reference ..........................................................2
Intended Use and Precautions ........................................2
Part Identification - HoverMatt® Air Transfer Mattress .....3
Part Identification - HT-Air® 1200 Air Supply ...................3
HT-Air® 1200 Air Supply Keypad Functions.....................3
Air200G/Air400G Air Supplies ........................................3
Instructions for Use .....................................................4-5
Product Specifications/Required Accessories ...............6-7
Cleaning and Preventive Maintenance ...........................7
Using the HoverMatt® Air Transfer System
in the Operating Room ..................................................7
Warranty Statement........................................................8
Returns and Repairs ........................................................8
User Manual
Symbol Reference
DECLARATION OF CONFORMITY TO MEDICAL DEVICE DIRECTIVE
Intended Use and Precautions
INTENDED USE
The HoverMatt® Air Transfer System is used to assist caregivers with patient transfers, positioning, turning and proning. The HoverTech Air Supply inflates the HoverMatt to cushion and cradle the patient, while air simultaneously escapes from the holes on the underside, reducing the force needed to move the patient by 80-90%.
INDICATIONS
• Patients unable to assist in their own lateral transfer
• Patients whose weight or girth poses a potential health risk for the caregivers responsible for repositioning or laterally transferring said patients
CONTRAINDICATIONS
• Patients who are experiencing thoracic, cervical or lumbar fractures that are deemed unstable, unless using in conjunction with a spinal board on top of the HoverMatt (follow your state’s protocol regarding use of spinal boards)
INTENDED CARE SETTINGS
• Hospitals, long term or extended care facilities
PRECAUTIONS  HOVERMATT
• Caregivers must verify that all caster brakes have been engaged prior to transfer.
• For safety, always use two people during patient transfer.
• Additional caregivers are recommended when moving a patient over 750 lbs/340kg.
• Never leave patient unattended on an inflated device.
• Use this product only for its intended purpose as described in this manual.
• Only use attachments and/or accessories that are authorized by Hov­erTech International.
• When transferring to a low air loss bed, set the bed mattress air flow to the highest level for a firm transfer surface.
• Never attempt to move a patient on an uninflated HoverMatt.
• WARNING: In the OR – To prevent the patient from slipping, always deflate the HoverMatt and secure the patient and HoverMatt to the OR table prior to moving the table into an angled position.
PRECAUTIONS  AIR SUPPLY
• Not for use in the presence of flammable anesthetics or in a hyperbaric chamber or oxygen tent.
• Route the power cord in a manner to ensure freedom from hazard.
• Avoid blocking the air intakes of the air supply.
• When using the HoverMatt in the MRI environment, a 25 ft. specialty MRI hose is required (available for purchase).
• CAUTION: Avoid electric shock. Do not open air supply.
• WARNING: Reference product specific user manuals for operating instructions.
User Manual
Part Identification – HoverMatt® Air Transfer Mattress
Patient Safety Straps (2) DO NOT USE TO TRANSFER
Hose Entries (2)
Transfer Handles (6)
Single-Patient Use: Transfer Handles (8)
Part Identification – HT-Air® 1200 Air Supply
Power Cord Strap
Hose Release Button
Control Panel Label
Power Cord (US/UK/Euro)
WARNING: The HT-Air is not compatible with DC power supplies.
The HT-Air is not for use with the HoverJack Battery Cart.
Carrying Handle/ Attachment Hook
Hose Nozzle
Hose
Air Filter Cover
HT-Air® 1200 Air Supply Keypad Function
(Green Flashing LED)
Indication
Adjustable/
Pressure
Setting
Standby (Amber LED)
Power IndicationAdjustable Speed
Green LEDs
Transfer Speed High
Transfer Speed Low
ADJUSTABLE: For use with HoverTech air-assisted positioning devices. There are four dierent settings. Each press of the button increases the air pressure and rate of inflation. The Green Flashing LED will indicate the inflation speed by the number of flashes (i.e. two flashes equals the second inflation speed).
All of the settings in the ADJUSTABLE range are substantially lower than the HoverMatt and HoverJack settings. The ADJUSTABLE function is not to be used for transferring.
The ADJUSTABLE setting is a safety feature that can be used to ensure the patient is centered on HoverTech air-assisted devices and to gradually accustom a patient who is timid or in pain to both the sound and functionality of the inflated devices.
STANDBY: Used to stop inflation/air flow (Amber LED indicates STANDBY mode).
HOVERMATT 28/34: For use with 28" & 34" HoverMatts and HoverSlings.
HOVERMATT 39/50 & HOVERJACK: For use with 39" & 50" HoverMatts and HoverSlings and 32" & 39" HoverJacks.
Air200G/Air400G Air Supplies
If using HoverTech’s Air200G or Air400G Air Supplies, press the grey button on the top of the canister to initiate air flow. Press the button again to stop air flow.
HMManual, Rev. D www.HoverMatt.com | 3