Hoshizaki KM-1300NRF User Manual

ISSUED: REVISED:
JUNE 1, 2000 JUNE 7, 2000
HOSHIZAKI
MODULAR CRESCENT CUBER
MODEL
KM-1300NRF
INSTRUCTION MANUAL
1
IMPORT ANT
Only qualified service technicians should attempt to install, service or maintain this icemaker. No installation, service or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual. Likewise, the owner/manager should not proceed to operate the icemaker until the installer has instructed them on its proper operation.
HOSHIZAKI provides this manual primarily to assist qualified service technicians in the installation, maintenance and service of the icemaker .
Should the reader have any questions or concerns which have not been satisfactorily addressed, please call or write to HOSHIZAKI Technical Support for assistance.
HOSHIZAKI AMERICA, INC. 618 Highway 74 South Peachtree City, GA 30269
Attn: HOSHIZAKI T echnical Support Department
Phone: 1-800-233-1940 T echnical Service
(770) 487-2331
Fax: (770) 487-3360
NOTE: T o expedite assistance, all correspondence/communication MUST include the following
information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem
2
 Please review this manual. It should be read carefully before the icemaker is installed and
operated. Only qualified service technicians should install, service and maintain the icemaker. This manual should be made available to the technician prior to installation, maintenance or service.
 Keep this manual with the icemaker for later reference.
CONTENTS PAGE
I. SPECIFICATIONS ..................................................................................................4
1. NAMEPLATE RATING ......................................................................................... 4
2. DIMENSIONS/CONNECTIONS ........................................................................... 5
II. INSTALLATION AND OPERATING INSTRUCTIONS...........................................6
1. CHECKS BEFORE INSTALLATION.................................................................... 6
2. HOW TO REMOVE PANELS ...............................................................................6
3. LOCATION ...........................................................................................................7
4. SET UP ................................................................................................................7
5. ELECTRICAL CONNECTION.............................................................................. 9
6. INSTALLATION OF REMOTE CONDENSER UNIT ..........................................10
[a] CHECKS BEFORE INSTALLATION .............................................................10
[b] LOCATION ....................................................................................................10
[c] SET UP..........................................................................................................11
[d] ELECTRICAL CONNECTION....................................................................... 1 2
[e] STACKING CONDENSER UNIT .................................................................. 13
7. WATER SUPPLY AND DRAIN CONNECTIONS .............................................. 14
8. FINAL CHECK LIST ...........................................................................................16
9. START UP..........................................................................................................17
10. PREPARING THE ICEMAKER FOR LONG STORAGE....................................18
III. MAINTENANCE AND CLEANING INSTRUCTIONS..........................................19
1. CLEANING INSTRUCTIONS ............................................................................. 19
[a] CLEANING PROCEDURE ............................................................................ 19
[b] SANITIZING PROCEDURE........................................................................... 2 1
2. MAINTENANCE .................................................................................................. 22
3
I. SPECIFICATIONS
1. NAMEPLATE RATING
MODEL NUMBER SERIAL NUMBER AC SUPPLY VOLTAGE
COMPRESSOR PUMP FAN OTHER MAXIMUM FUSE SIZE MAX. HACR BREAKER (USA ONLY) MAX. CIRC. BREAKER (CANADA ONLY) MINIMUM CIRCUIT AMPACITY DESIGN PRESSURE REFRIGERANT MOTOR-COMPRESSOR THERMALLY PROTECTED NOT INTENDED FOR OUTDOOR USE
HOSHIZAKI ICE MAKER
KM-1300NRF
208-230/60/1 (3 wire with Neutral for 115V)
208-230V 10.0RLA 61LRA
120V 1.2FLA 60W
REMOTE 120V 3A MAX
115-120V 0.3A
20AMPS 20AMPS
20AMPS 20AMPS
HI-467PSI LO-230PSI
404A
HOSHIZAKI AMERICA, INC.
Peachtree City, GA
See the Nameplate for electrical and refrigeration specifications. This Nameplate is located on the upper right hand side of rear panel.
Since this Nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specifications and design without prior notice.
4
2. DIMENSIONS/CONNECTIONS
Note: When used with a storage bin not recommended by Hoshizaki, the icemaker needs
the space at the bottom opening as in the illustration.
5
II. INSTALLATION AND OPERATING INSTRUCTIONS
1. CHECKS BEFORE INSTALLATION
IMPORTANT
Remove shipping carton, tape(s) and packing. If packing material is left in the icemaker, it will not work properly.
1) Remove the panels to prevent damage when installing the icemaker. (See “2. HOW TO REMOVE PANELS.”)
2) Remove the package containing the accessories from the compressor compartment.
3) Remove the protective plastic film from the panels. If the icemaker is exposed to the sun or to heat, remove the film after the icemaker cools.
4) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the fan blade turns freely.
5) Check that the Compressor is snug on all mounting pads.
6) See the Nameplate on the Rear Panel, and check that your voltage supplied corresponds with the voltage specified on the Nameplate.
7) A remote condenser unit is needed with this model. The recommended remote condenser unit is HOSHIZAKI CONDENSER UNIT, Model URC-12F.
2. HOW TO REMOVE PANELS - See Fig. 1
a) Front Panel.......... Remove the two screws.
Lift up and pull toward you.
b) Top Panel............ Remove the two screws, and
then lift off.
c) Side Panel (R)..... Remove the screw.
Pull slightly toward you, and take off.
d) Insulation Panel .. Remove the Thumbscrew.
Lift up slightly, and pull toward you.
6
Fig. 1
3. LOCATION
W ARNING
This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within +45°F to +100°F; Normal operating water temperature should be within +45°F to +90°F. Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect production capacity.
For best operating results:
• Icemaker should not be located next to ovens, grills or other high heat producing equipment.
• Location should provide a firm and level foundation for the equipment.
• Allow 6" clearance at rear, sides and top for proper air circulation and ease of maintenance and/or service should they be required.
4. SET UP
CAUTION
Before operating the icemaker, the Bin Control Assembly must be installed correctly.
1) Install the Bin Control Assembly as follows. See Figures 2 and 3. (a) Remove the shipping tape securing the Bin Control Assembly. Remove the
Assembly from the shipping hook by lifting it up and shifting to the right.
(b) Lower the Bin Control Assembly through the hole located at the bottom of the
icemaker. (c) Insert the Plug into the Receptacle on the Bin Control Assembly until it locks in place (d) Secure the Assembly in place with the thumbscrew.
2) Level the icemaker/Storage Bin in both the left-to-right and front-to-rear directions.
7