NO: |
73076 |
|
ISSUED: |
OCT. 8, 1998 |
|
REVISED: |
DEC. 14, 2003 |
HOSHIZAKI
STACKABLE CRESCENT CUBER
MODELS KM-1300SAF KM-1300SWF KM-1300SRF KM-1300SAF3 KM-1300SWF3 KM-1300SRF3
SERVICE MANUAL
IMPORTANT
Only qualified service technicians should attempt to service or maintain this icemaker.
No such service or maintenance should be undertaken until the technician has thoroughly read this Service Manual.
HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily addressed, please call or write to the HOSHIZAKI Technical Support Department for assistance.
HOSHIZAKI AMERICA, INC.
618 Highway 74 South
Peachtree City, GA 30269
Attn: HOSHIZAKI Technical Support Department
Phone: 1-800-233-1940 Technical Service
|
(770) 487-2331 |
Fax: |
(770) 487-3360 |
NOTE: To expedite assistance, all correspondence/communication MUST include the following information:
•Model Number
•Serial Number
•Complete and detailed explanation of the problem
2
Please review this manual. It should be read carefully before the icemaker is serviced or maintenance operations are performed. Only qualified service technicians should service and maintain the icemaker. This manual should be made available to the technician prior to service or maintenance.
|
CONTENTS |
|
|
|
PAGE |
I. SPECIFICATIONS .................................................................................................... |
5 |
|
1. |
KM-1300SAF (Air-cooled) ................................................................................... |
5 |
2. |
KM-1300SWF (Water-cooled) ............................................................................. |
6 |
3. |
KM-1300SRF (Remote air-cooled) ...................................................................... |
7 |
4. |
KM-1300SAF3 (Air-cooled, 3 phase) .................................................................. |
8 |
5. |
KM-1300SWF3 (Water-cooled, 3 phase) ............................................................ |
9 |
6. |
KM-1300SRF3 (Remote air-cooled, 3 phase) ................................................... |
10 |
7. |
CONDENSING UNIT, URC-12F ....................................................................... |
11 |
II. GENERAL INFORMATION .................................................................................... |
13 |
|
1. |
CONSTRUCTION ............................................................................................. |
13 |
|
[a] KM-1300SAF/3............................................................................................ |
13 |
|
[b] KM-1300SWF/3........................................................................................... |
14 |
|
[c] KM-1300SRF/3............................................................................................ |
15 |
2. |
CONTROLLER BOARD .................................................................................... |
16 |
|
[a] SOLID-STATE CONTROL .......................................................................... |
16 |
|
[b] CONTROLLER BOARD .............................................................................. |
16 |
|
[c] SEQUENCE ................................................................................................ |
23 |
|
[d] CONTROLS AND ADJUSTMENTS ............................................................ |
26 |
|
[e] CHECKING THE CONTROLLER BOARD ................................................... |
29 |
III. TECHNICAL INFORMATION ............................................................................... |
32 |
|
1. |
WATER CIRCUIT AND REFRIGERANT CIRCUIT ........................................... |
32 |
|
[a] KM-1300SAF/3............................................................................................ |
32 |
|
[b] KM-1300SWF/3........................................................................................... |
33 |
|
[c] KM-1300SRF/3............................................................................................ |
34 |
2. |
WIRING DIAGRAMS......................................................................................... |
35 |
|
[a] KM-1300SAF............................................................................................... |
35 |
|
[b] KM-1300SWF.............................................................................................. |
36 |
|
[c] KM-1300SRF............................................................................................... |
37 |
|
[d] KM-1300SAF3............................................................................................. |
38 |
|
[e] KM-1300SWF3............................................................................................ |
39 |
|
[f] KM-1300SRF3 ............................................................................................. |
40 |
3. |
TIMING CHART ................................................................................................ |
41 |
4. |
PERFORMANCE DATA.................................................................................... |
43 |
|
[a] KM-1300SAF............................................................................................... |
43 |
|
[b] KM-1300SWF.............................................................................................. |
44 |
|
[c] KM-1300SRF............................................................................................... |
45 |
|
[d] KM-1300SAF3............................................................................................. |
46 |
|
[e] KM-1300SWF3............................................................................................ |
47 |
|
[f] KM-1300SRF3 ............................................................................................. |
48 |
3
IV. SERVICE DIAGNOSIS ........................................................................................... |
49 |
|
1. |
NO ICE PRODUCTION........................................................................................ |
49 |
2. |
EVAPORATOR IS FROZEN UP .......................................................................... |
52 |
3. |
LOW ICE PRODUCTION ..................................................................................... |
53 |
4. |
ABNORMAL ICE .................................................................................................. |
53 |
5. |
OTHERS .............................................................................................................. |
53 |
V. REMOVAL AND REPLACEMENT OF COMPONENTS .......................................... |
54 |
|
1. |
SERVICE FOR REFRIGERANT LINES............................................................... |
54 |
|
[a] REFRIGERANT RECOVERY ........................................................................ |
54 |
|
[b] EVACUATION AND RECHARGE .................................................................. |
54 |
2. |
BRAZING ............................................................................................................. |
55 |
3. |
REMOVAL AND REPLACEMENT OF COMPRESSOR ...................................... |
56 |
4. |
REMOVAL AND REPLACEMENT OF DRIER ..................................................... |
57 |
5. |
REMOVAL AND REPLACEMENT OF EXPANSION VALVE .............................. |
58 |
6. |
REMOVAL AND REPLACEMENT OF HOT GAS VALVE, ...................................... |
|
|
LINE VALVE AND GAS VALVE.......................................................................... |
59 |
7. |
REMOVAL AND REPLACEMENT OF EVAPORATOR ....................................... |
60 |
8. |
REMOVAL AND REPLACEMENT OF WATER-REGULATING VALVE .................. |
|
|
- WATER COOLED MODEL ONLY .................................................................... |
61 |
9. |
ADJUSTMENT OF WATER-REGULATING VALVE ................................................ |
|
|
- WATER COOLED MODEL ONLY .................................................................... |
62 |
10. REMOVAL AND REPLACEMENT OF CONDENSING PRESSURE ....................... |
|
|
|
REGULATOR (C.P.R.) - REMOTE AIR-COOLED MODEL ONLY .................. |
63 |
11. REMOVAL AND REPLACEMENT OF THERMISTOR ......................................... |
64 |
|
12. REMOVAL AND REPLACEMENT OF FAN MOTOR ........................................... |
65 |
|
13. REMOVAL AND REPLACEMENT OF WATER VALVE ....................................... |
66 |
|
14. REMOVAL AND REPLACEMENT OF PUMP MOTOR ........................................ |
66 |
|
15. REMOVAL AND REPLACEMENT OF SPRAY TUBES ....................................... |
67 |
|
VI. MAINTENANCE AND CLEANING INSTRUCTIONS .............................................. |
68 |
|
1. |
PREPARING THE ICEMAKER FOR LONG STORAGE ...................................... |
68 |
2. |
CLEANING PROCEDURE ................................................................................... |
70 |
|
[a] CLEANING PROCEDURE ............................................................................. |
71 |
|
[b] SANITIZING PROCEDURE ........................................................................... |
73 |
3. |
MAINTENANCE ................................................................................................... |
74 |
4
I.SPECIFICATIONS
1.KM-1300SAF (Air-cooled)
AC SUPPLY VOLTAGE |
208-230/60/1 ( 3 wire with neutral for 115 V ) |
||||||||||||||||
AMPERAGE |
12.6 A ( 5 min. freeze AT 104° F / WT 80° F ) |
||||||||||||||||
MINIMUM CIRCUIT AMPACITY |
20A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
MAXIMUM FUSE SIZE |
20A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|||||||
APPROX. ICE PRODUCTION |
|
|
|
|
|
||||||||||||
|
|
Ambient |
|
|
|
Water Temp. (°F) |
|||||||||||
PER 24 HR. |
|
|
Temp. (°F) |
|
|
|
50 |
70 |
|
90 |
|||||||
|
lbs./day ( kg./day ) |
|
|
70 |
|
|
|
|
|
*1283 (582) |
1238 (562) |
|
1135 (515) |
||||
|
Reference without *marks |
|
|
80 |
|
|
|
|
|
1249 (566) |
1178 (535) |
|
1053 (478) |
||||
|
|
|
|
90 |
|
|
|
|
|
1238 (562) |
*1129 (512) |
|
1011 (458) |
||||
|
|
|
|
100 |
|
|
|
|
|
1203 (546) |
1101 (500) |
|
*902 (409) |
||||
|
|
|
|
|
|
|
|
|
|
||||||||
SHAPE OF ICE |
Crescent Cube |
|
|
|
|
|
|||||||||||
ICE PRODUCTION PER CYCLE |
30.1 lbs. ( 13.7 kg. ) 1440 pcs. |
|
|||||||||||||||
APPROXIMATE STORAGE CAPACITY |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
ELECTRIC & WATER CONSUMPTION |
90° F / 70° F |
|
|
70° F / 50° F |
|
||||||||||||
|
ELECTRIC W ( KWH/100 lbs. ) |
2235 ( 4.75 ) |
|
|
2180 ( 4.08 ) |
|
|
||||||||||
|
WATER gal./24 HR. ( gal./100 lbs. ) |
247 ( 21.9 ) |
|
|
|
479 ( 37.3 ) |
|
|
|||||||||
EXTERIOR DIMENSIONS ( WxDxH ) |
48" x 27 |
¦ " x 27 |
|
¦ " ( 1219 x 695 x 695 mm. ) |
|||||||||||||
|
|
|
|
|
|
|
|
|
3 |
8 |
|
|
3 |
8 |
|
|
|
EXTERIOR FINISH |
Stainless steel, Galvanized Steel ( Rear ) |
|
|||||||||||||||
WEIGHT |
Net 275 lbs. ( 125 kg. ) Shipping 315 lbs. ( 143 kg. ) |
||||||||||||||||
CONNECTIONS - ELECTRIC |
Permanent Connection |
|
|
|
|||||||||||||
|
- WATER SUPPLY |
Inlet |
1 |
¦ " FPT |
|
|
|
|
|
|
|||||||
|
- DRAIN |
|
|
|
2 |
¦ " FPT |
|
|
|
|
|
||||||
|
Outlet |
3 |
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
|
||
|
|
3 |
¦ " ID Pipe |
|
|
|
|
|
|
||||||||
|
|
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
CUBE CONTROL SYSTEM |
Float Switch |
|
|
|
|
|
|
||||||||||
HARVESTING CONTROL SYSTEM |
Hot Gas and Water, Thermistor and Timer |
||||||||||||||||
ICE MAKING WATER CONTROL |
Timer Controlled, Overflow Pipe |
|
|||||||||||||||
COOLING WATER CONTROL |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
BIN CONTROL SYSTEM |
Thermostat |
|
|
|
|
|
|
||||||||||
COMPRESSOR |
Hermetic, Model CS14K6E-PFV |
|
|||||||||||||||
CONDENSER |
Air-cooled, Fin and Tube type |
|
|||||||||||||||
EVAPORATOR |
Vertical type, Stainless Steel and Copper |
|
|||||||||||||||
REFRIGERANT CONTROL |
Thermostatic Expansion Valve |
|
|||||||||||||||
REFRIGERANT CHARGE |
R404A, 3 lbs. 14 oz. ( 1750 g. ) |
|
|||||||||||||||
DESIGN PRESSURE |
High 467 PSIG, Low 230 PSIG |
|
|||||||||||||||
P.C. BOARD CIRCUIT PROTECTION |
High Voltage Cut-out ( Internal ) |
|
|||||||||||||||
COMPRESSOR PROTECTION |
Auto-reset Overload Protector ( Internal ) |
|
|||||||||||||||
REFRIGERANT CIRCUIT PROTECTION |
Auto-reset High Pressure Control Switch |
|
|||||||||||||||
LOW WATER PROTECTION |
Float Switch |
|
|
|
|
|
|
||||||||||
ACCESSORIES - SUPPLIED |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
- REQUIRED |
Ice Storage Bin |
|
|
|
|
|
||||||||||
OPERATION CONDITIONS |
VOLTAGE RANGE |
187 - 264 V |
|||||||||||||||
|
|
AMBIENT TEMP. |
45 - 100° F |
||||||||||||||
|
|
WATER SUPPLY TEMP. |
45 - 90° F |
||||||||||||||
|
|
WATER SUPPLY PRESS. |
10 - 113 PSIG |
We reserve the right to make changes in specifications and design without prior notice.
5
2. KM-1300SWF (Water-cooled)
|
AC SUPPLY VOLTAGE |
208-230/60/1 ( 3 wire with neutral for 115 V ) |
|
|
|
|
|||||||||||||||
|
|
|
AMPERAGE |
9.7 A ( 5 MIN. Freeze AT 104° F / WT 80° F ) |
|
|
|
||||||||||||||
|
|
|
MINIMUM CIRCUIT AMPACITY |
20A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MAXIMUM FUSE SIZE |
|
20A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
APPROX. ICE PRODUCTION |
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
Ambient |
|
|
|
|
|
|
Water Temp. (°F) |
|
|
|
|
|||||||||
|
PER 24 HR. |
Temp. (°F) |
|
|
|
|
50 |
|
70 |
|
90 |
|
|
||||||||
|
|
|
lbs./day ( kg./day ) |
70 |
|
|
*1252 ( 568 ) |
|
1233 ( 559 ) |
1176 ( 533 ) |
|
||||||||||
|
|
|
Reference without *marks |
80 |
|
|
|
1238 ( 561 ) |
|
1209 ( 548 ) |
1134 ( 514 ) |
|
|||||||||
|
|
|
|
|
90 |
|
|
|
1233 ( 559 ) |
|
*1188 ( 539 ) |
1119 ( 508 ) |
|
||||||||
|
|
|
|
|
100 |
|
|
|
1211 ( 549 ) |
|
1172 ( 532 ) |
1056 ( 479 ) |
|
||||||||
|
SHAPE OF ICE |
Crescent Cube |
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
ICE PRODUCTION PER CYCLE |
30.1 lbs. ( 13.7 kg. ) 1440 pcs. |
|
|
|
|
|
|
|||||||||||||
|
APPROXIMATE STORAGE CAPACITY |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
ELECTRIC & WATER CONSUMPTION |
90° F / 70° F |
|
|
|
|
70° F / 50° F |
|
|
|
|
|
|
||||||||
|
|
|
ELECTRIC W ( KWH/100 lbs. ) |
2050 ( 4.0 ) |
|
|
|
|
|
1975 ( 3.8 ) |
|
|
|
|
|
|
|||||
|
|
|
WATER gal./24 HR. ( gal./100 lbs. ) |
325 ( 27.4 ) |
|
|
|
|
|
623 ( 49.8 ) |
|
|
|
|
|
|
|||||
|
|
|
WATER COOLED CONDENSER |
1521 ( 128 ) |
|
|
|
|
|
964 ( 77 ) |
|
|
|
|
|
|
|||||
|
|
|
gal./24 hr. ( gal./100 lbs. ) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
EXTERIOR DIMENSIONS ( WxDxH ) |
48" x 27 |
3 |
¦ " x 27 |
3 |
¦ |
" ( 1219 x 695 x 695 mm. ) |
|
|
|
|
||||||||||
|
|
|
|
|
|
8 |
|
|
|
8 |
|
|
|
|
|
|
|
|
|
||
|
EXTERIOR FINISH |
Stainless steel, Galvanized Steel ( Rear ) |
|
|
|
|
|||||||||||||||
|
WEIGHT |
Net 265 lbs. ( 120 kg. ) Shipping 315 lbs. ( 143 kg. ) |
|||||||||||||||||||
|
CONNECTIONS - ELECTRIC |
Permanent Connection |
Condenser Inlet |
|
¦ " FPT |
||||||||||||||||
|
|
|
- WATER SUPPLY |
Inlet |
|
|
|
1 |
¦ " FPT |
1 |
|||||||||||
|
|
|
- DRAIN |
Outlet |
|
|
|
2 |
|
|
|
Condenser Outlet |
2 |
|
|
||||||
|
|
|
|
|
|
3 |
¦ " FPT |
3 |
¦ " FPT |
||||||||||||
|
|
|
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
8 |
|
|
||
|
|
|
|
|
|
|
|
|
3 |
¦ " ID Pipe |
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CUBE CONTROL SYSTEM |
Float Switch |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
HARVESTING CONTROL SYSTEM |
Hot Gas and Water, Thermistor and Timer |
|
|
|
|
|||||||||||||||
|
ICE MAKING WATER CONTROL |
Timer Controlled, Overflow Pipe |
|
|
|
|
|
|
|||||||||||||
|
COOLING WATER CONTROL |
Water Regulator |
|
|
|
|
|
|
|
|
|
|
|||||||||
|
BIN CONTROL SYSTEM |
Thermostat |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
COMPRESSOR |
Hermetic, Model CS14K6E-PFV |
|
|
|
|
|
|
||||||||||||
|
CONDENSER |
Water-cooled, Tube in Tube type |
|
|
|
|
|
|
|||||||||||||
|
EVAPORATOR |
Vertical type, Stainless Steel and Copper |
|
|
|
|
|||||||||||||||
|
REFRIGERANT CONTROL |
Thermostatic ExpansionValve |
|
|
|
|
|
|
|||||||||||||
|
REFRIGERANT CHARGE |
R404A, 2 lb. 2 oz. ( 950 g. ) |
|
|
|
|
|
|
|||||||||||||
|
DESIGN PRESSURE |
High 427 PSIG, Low 230 PSIG |
|
|
|
|
|
|
|||||||||||||
|
P.C. BOARD CIRCUIT PROTECTION |
High Voltage Cut-out ( Internal ) |
|
|
|
|
|
|
|||||||||||||
|
COMPRESSOR PROTECTION |
Auto-reset Overload Protector ( Internal ) |
|
|
|
|
|||||||||||||||
|
REFRIGERANT CIRCUIT PROTECTION |
Auto-reset High Pressure Control Switch |
|
|
|
|
|||||||||||||||
|
LOW WATER PROTECTION |
Float Switch |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
ACCESSORIES - SUPPLIED |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
- REQUIRED |
Ice Storage Bin |
|
|
|
|
|
|
|
|
|
|
|
||||||
|
OPERATION CONDITIONS |
VOLTAGE RANGE |
|
|
187 - 253 V |
||||||||||||||||
|
|
|
|
|
AMBIENT TEMP. |
|
|
|
45 - 100° F |
|
|
|
|
||||||||
|
|
|
|
|
WATER SUPPLY TEMP. |
|
|
45 - 90° F |
|
|
|
|
|||||||||
We reserve the right to make changes in |
WATER SUPPLY PRESS. |
10 - 113 PSIG |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
specifications and design without prior notice.
6
3. KM-1300SRF (Remote air-cooled)
|
AC SUPPLY VOLTAGE |
208-230/60/1 ( 3 wire with neutral for 115 V ) |
|||||||||||||||
|
AMPERAGE |
14.5 A ( 5 min. freeze AT 104° F / WT 80° F ) |
|||||||||||||||
|
MINIMUM CIRCUIT AMPACITY |
20A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MAXIMUM FUSE SIZE |
|
20A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
APPROX. ICE PRODUCTION REFERENCE |
Ambient |
|
|
|
Water Temp. (°F) |
|
|
|||||||||
|
PER 24 HR. |
Temp. (°F) |
|
|
|
50 |
|
70 |
|
90 |
|
|
|||||
|
lbs./day ( kg./day ) |
70 |
|
|
|
|
*1296 (588) |
|
1248 (566) |
|
1173 (532) |
|
|
||||
|
Reference without *marks |
80 |
|
|
|
|
1260 (571) |
|
1185 (538) |
|
1105 (501) |
|
|
||||
|
|
|
90 |
|
|
|
|
1248 (566) |
|
*1133 (514) |
|
1053 (478) |
|
|
|||
|
|
|
100 |
|
|
|
|
1230 (558) |
|
1114 (505) |
|
*980 (445) |
|
|
|||
|
SHAPE OF ICE |
Crescent Cube |
|
|
|
|
|
|
|
|
|
||||||
|
ICE PRODUCTION PER CYCLE |
30.1 lbs. ( 13.7 kg. ) 1440 pcs. |
|
|
|
|
|
||||||||||
|
APPROXIMATE STORAGE CAPACITY |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ELECTRIC & WATER CONSUMPTION |
90°F/70°F |
|
|
70°F/50°F |
|
|
|
|
|
|||||||
|
ELECTRIC W ( KWH/100 lbs. ) |
2350 ( 4.98 ) |
|
|
2300 ( 4.26 ) |
|
|
|
|
|
|||||||
|
WATER gal./24 HR. ( gal./100 lbs. ) |
273 ( 24.1 ) |
|
|
456 ( 35.2 ) |
|
|
|
|
|
|||||||
|
EXTERIOR DIMENSIONS ( WxDxH ) |
48" x 27 |
¦ " x 27 |
|
¦ " ( 1219 x 695 x 695 mm. ) |
|
|||||||||||
|
|
|
|
|
3 |
8 |
|
|
3 |
8 |
|
|
|
|
|
|
|
|
EXTERIOR FINISH |
Stainless steel, Galvanized Steel (Rear) |
|||||||||||||||
|
WEIGHT |
Net 255 lbs. ( 116 kg. ) |
Shipping 315 lbs. ( 143 kg. ) |
||||||||||||||
|
CONNECTIONS - ELECTRIC |
Permanent Connection |
|
|
|
|
|
|
|
||||||||
|
- WATER SUPPLY |
Inlet |
1 |
¦ " FPT |
|
|
|
|
|
|
|
|
|
||||
|
- DRAIN |
Outlet |
|
2 |
|
|
|
|
|
|
|
|
|
|
|
||
|
3 |
¦ " FPT |
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
¦ " ID Pipe |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
CUBE CONTROL SYSTEM |
Float Switch |
|
|
|
|
|
|
|
|
|
|
|||||
|
HARVESTING CONTROL SYSTEM |
Hot Gas and Water, Thermistor and Timer |
|||||||||||||||
|
ICE MAKING WATER CONTROL |
Timer Controlled, Overflow Pipe |
|
|
|
|
|
||||||||||
|
COOLING WATER CONTROL |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BIN CONTROL SYSTEM |
Thermostat |
|
|
|
|
|
|
|
|
|
|
|||||
|
COMPRESSOR |
Hermetic, Model CS14K6E-PFV |
|
|
|
|
|
||||||||||
|
CONDENSER |
Air-cooled remote, Condenser Unit URC-12F |
|||||||||||||||
|
|
|
recommended |
|
|
|
|
|
|
|
|
|
|||||
|
EVAPORATOR |
Vertical type, Stainless Steel and Copper |
|||||||||||||||
|
REFRIGERANT CONTROL |
Thermostatic Expansion Valve, |
|
|
|
|
|
||||||||||
|
|
|
Condensing Pressure Regulator on URC-12F |
||||||||||||||
|
REFRIGERANT CHARGE |
R404A, 11 lbs. 7 oz. ( 5200 g. ) |
|
|
|
|
|
||||||||||
|
|
|
( Ice maker 7 lbs.; Cond. unit 4 lbs. 7 oz. ) |
||||||||||||||
|
DESIGN PRESSURE |
HIGH 467 PSIG, LOW 230 PSIG |
|
|
|
|
|||||||||||
|
P.C. BOARD CIRCUIT PROTECTION |
High Voltage Cut-out ( Internal ) |
|
|
|
|
|
||||||||||
|
COMPRESSOR PROTECTION |
Auto-reset Overload Protector ( Internal ) |
|||||||||||||||
|
REFRIGERANT CIRCUIT PROTECTION |
Auto-reset High Pressure Control Switch |
|||||||||||||||
|
LOW WATER PROTECTION |
Float Switch |
|
|
|
|
|
|
|
|
|
|
|||||
|
ACCESSORIES - SUPPLIED |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- REQUIRED |
Ice Storage Bin, Remote Condenser Unit |
|||||||||||||||
|
OPERATION CONDITIONS |
VOLTAGE RANGE |
|
187 - 264 V |
|||||||||||||
|
|
|
AMBIENT TEMP. |
|
|
45 - 100° F |
|||||||||||
|
|
|
WATER SUPPLY TEMP. |
|
|
45 - |
90° F |
||||||||||
We reserve the right to make changes in |
WATER SUPPLY PRESS. |
10 - 113 PSIG |
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
specifications and design without prior notice.
7
4. KM-1300SAF3 (Air-cooled)
AC SUPPLY VOLTAGE |
208-230/60/3 |
|
|
|
|
|
|
|
|
||||||||||
AMPERAGE |
7.8 A ( 5 min. freeze AT 104° F / WT 80° F ) |
||||||||||||||||||
MINIMUM CIRCUIT AMPACITY |
20A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
MAXIMUM FUSE SIZE |
20A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
APPROX. ICE PRODUCTION |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
Ambient |
|
|
Water Temp. (°F) |
|
|
|
|
||||||||||
PER 24 HR. |
|
|
Temp. (°F) |
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
50 |
70 |
|
90 |
|
|
|
|||||||||
lbs./day ( kg./day ) |
|
|
70 |
|
|
|
|
|
*1320 ( 599 ) |
1257 ( 570 ) |
1153 ( 523 ) |
|
|||||||
Reference without *marks |
|
|
80 |
|
|
|
|
|
1272 ( 577 ) |
1174 ( 533 ) |
1060 ( 481 ) |
||||||||
|
|
|
90 |
|
|
|
|
|
1257 ( 570 ) |
*1105 ( 501 ) |
993 ( 450 ) |
||||||||
|
|
|
100 |
|
|
|
|
|
1230 ( 558 ) |
1079 ( 489 ) |
|
*890 ( 404 ) |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
SHAPE OF ICE |
Crescent Cube |
|
|
|
|
|
|
|
|
||||||||||
ICE PRODUCTION PER CYCLE |
30.1 lbs. ( 13.7 kg. ) 1440 pcs. |
|
|
|
|
||||||||||||||
APPROXIMATE STORAGE CAPACITY |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
ELECTRIC & WATER CONSUMPTION |
90° F / 70° F |
|
|
70° F / 50° F |
|
|
|
|
|||||||||||
ELECTRIC W ( KWH/100 lbs. ) |
2275 ( 5.0 ) |
|
|
2150 ( 3.9 ) |
|
|
|
|
|
||||||||||
WATER gal./24 HR. ( gal./100 lbs. ) |
292 ( 21.9 ) |
|
|
488 ( 37.3 ) |
|
|
|
|
|
||||||||||
EXTERIOR DIMENSIONS ( WxDxH ) |
48" x 27 |
3 |
¦ |
" x 27 |
3 |
¦ " ( 1219 x 695 x 695 mm. ) |
|
||||||||||||
|
|
|
|
|
|
|
|
8 |
|
|
8 |
|
|
|
|
|
|
||
EXTERIOR FINISH |
Stainless steel, Galvanized Steel ( Rear ) |
|
|
|
|
||||||||||||||
WEIGHT |
Net 275 lbs. ( 125 kg. ) Shipping 315 lbs. ( 143 kg. ) |
||||||||||||||||||
CONNECTIONS - ELECTRIC |
Permanent Connection |
|
|
|
|
|
|
||||||||||||
- WATER SUPPLY |
Inlet |
1 |
¦ " FPT |
|
|
|
|
|
|
|
|
|
|||||||
- DRAIN |
|
|
|
2 |
¦ " FPT |
|
|
|
|
|
|
|
|
||||||
Outlet |
3 |
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
|
|
|
|
||
|
3 |
¦ " ID Pipe |
|
|
|
|
|
|
|
|
|
||||||||
|
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
CUBE CONTROL SYSTEM |
Float Switch |
|
|
|
|
|
|
|
|
|
|||||||||
HARVESTING CONTROL SYSTEM |
Hot Gas and Water, Thermistor and Timer |
|
|
|
|
||||||||||||||
ICE MAKING WATER CONTROL |
Timer Controlled, Overflow Pipe |
|
|
|
|
||||||||||||||
COOLING WATER CONTROL |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
BIN CONTROL SYSTEM |
Thermostat |
|
|
|
|
|
|
|
|
|
|||||||||
COMPRESSOR |
Hermetic, Model CS14K6E-TF5 |
|
|
|
|
||||||||||||||
CONDENSER |
Air-cooled, Fin and Tube type |
|
|
|
|
||||||||||||||
EVAPORATOR |
Vertical type, Stainless Steel and Copper |
|
|
|
|
||||||||||||||
REFRIGERANT CONTROL |
Thermostatic ExpansionValve |
|
|
|
|
||||||||||||||
REFRIGERANT CHARGE |
R404A, 3 lbs. 14 oz. ( 1750 g. ) |
|
|
|
|
||||||||||||||
DESIGN PRESSURE |
High 467 PSIG, Low 230 PSIG |
|
|
|
|
||||||||||||||
P.C. BOARD CIRCUIT PROTECTION |
High Voltage Cut-out; Low Voltage Cut-out (Internal) |
|
|
||||||||||||||||
COMPRESSOR PROTECTION |
Auto-reset Overload Protector ( Internal ) |
|
|
|
|
||||||||||||||
REFRIGERANT CIRCUIT PROTECTION |
Auto-reset High Pressure Control Switch |
|
|
|
|
||||||||||||||
LOW WATER PROTECTION |
Float Switch |
|
|
|
|
|
|
|
|
|
|||||||||
ACCESSORIES - SUPPLIED |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
- REQUIRED |
Ice Storage Bin |
|
|
|
|
|
|
|
|
||||||||||
OPERATION CONDITIONS |
VOLTAGE RANGE |
187 - 253 V |
|
||||||||||||||||
|
AMBIENT TEMP. |
45 - 100° F |
|||||||||||||||||
|
WATER SUPPLY TEMP. |
45 - 90° F |
|||||||||||||||||
|
WATER SUPPLY PRESS. |
10 - 113 PSIG |
We reserve the right to make changes in specifications and design without prior notice.
8
5. KM-1300SWF3 (Water-cooled)
AC SUPPLY VOLTAGE |
208-230/60/3 |
|
|
|
|
|
|
|
|
|||||
|
AMPERAGE |
6.9 A ( 5 MIN. Freeze AT 104° F / WT 80° F ) |
||||||||||||
|
MINIMUM CIRCUIT AMPACITY |
20A |
|
|
|
|
|
|
|
|
|
|
||
MAXIMUM FUSE SIZE |
20A |
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
||||
APPROX. ICE PRODUCTION |
|
|
|
|
|
|
||||||||
Ambient |
|
|
Water Temp. (°F) |
|
|
|
|
|||||||
PER 24 HR. |
Temp. (°F) |
|
|
50 |
|
70 |
|
90 |
|
|
|
|||
|
lbs./day ( kg./day ) |
70 |
|
*1301 ( 590 ) |
1273 ( 577 ) |
1205 ( 547 |
|
) |
||||||
|
Reference without *marks |
80 |
|
|
1279 ( 580 ) |
1235 ( 560 ) |
1152 ( 523 |
|
) |
|||||
|
|
|
90 |
|
|
1273 ( 577 ) |
*1204 ( 546 ) |
1126 ( 511 |
|
) |
||||
|
|
|
100 |
|
|
1250 ( 567 ) |
|
1186 ( 538 ) |
*1055 ( 479) |
|
|
|||
SHAPE OF ICE |
Crescent Cube |
|
|
|
|
|
|
|
|
|||||
ICE PRODUCTION PER CYCLE |
30.1 lbs. ( 13.7 kg. ) 1440 pcs. |
|
|
|
|
|
|
|||||||
APPROXIMATE STORAGE CAPACITY |
N/A |
|
|
|
|
|
|
|
|
|
|
|||
ELECTRIC & WATER CONSUMPTION |
90° F / 70° F |
70° F / 50° F |
|
|
|
|
|
|
||||||
|
ELECTRIC W ( KWH/100 lbs. ) |
2125 ( 4.0 ) |
|
|
2075 ( 3.8 ) |
|
|
|
|
|
|
|||
|
WATER gal./24 HR. ( gal./100 lbs. ) |
342 ( 27.7 ) |
|
|
648 ( 49.8 ) |
|
|
|
|
|
|
|||
|
WATER COOLED CONDENSER |
1372 ( 112 ) |
|
|
885 ( 68 ) |
|
|
|
|
|
|
|||
|
gal./24 hr. ( gal./100 lbs. ) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
EXTERIOR DIMENSIONS ( WxDxH ) |
48" x 273¦8" x 273¦8" ( 1219 x 695 x 695 mm. ) |
|
|
|
|
||||||||
EXTERIOR FINISH |
Stainless steel, Galvanized Steel ( Rear ) |
|
|
|
|
|||||||||
WEIGHT |
Net 265 lbs. ( 120 kg. ) Shipping 315 lbs. ( 143 kg. ) |
|||||||||||||
CONNECTIONS - ELECTRIC |
Permanent Connection |
|
|
|
|
|
|
|
|
|||||
|
- WATER SUPPLY |
Inlet |
|
1¦2" FPT |
Condenser Inlet |
1¦2" FPT |
||||||||
|
- DRAIN |
Outlet |
|
3¦4" FPT |
Condenser Outlet |
3¦8" FPT |
||||||||
|
|
|
|
|
|
3¦8" ID Pipe |
|
|
|
|
|
|
|
|
|
CUBE CONTROL SYSTEM |
Float Switch |
|
|
|
|
|
|
|
|
|
|
||
HARVESTING CONTROL SYSTEM |
Hot Gas and Water, Thermistor and Timer |
|
|
|
|
|||||||||
ICE MAKING WATER CONTROL |
Timer Controlled, Overflow Pipe |
|
|
|
|
|
|
|||||||
COOLING WATER CONTROL |
Water Regulator |
|
|
|
|
|
|
|
|
|||||
BIN CONTROL SYSTEM |
Thermostat |
|
|
|
|
|
|
|
|
|
|
|||
|
COMPRESSOR |
Hermetic, Model CS14K6E-TF5 |
|
|
|
|
|
|
||||||
CONDENSER |
Water-cooled, Tube in Tube type |
|
|
|
|
|||||||||
EVAPORATOR |
Vertical type, Stainless Steel and Copper |
|
|
|
|
|||||||||
REFRIGERANT CONTROL |
Thermostatic ExpansionValve |
|
|
|
|
|
|
|||||||
REFRIGERANT CHARGE |
R404A, 2 lb. 2 oz. ( 950 g. ) |
|
|
|
|
|
|
|||||||
DESIGN PRESSURE |
High 427 PSIG, Low 230 PSIG |
|
|
|
|
|
|
|||||||
P.C. BOARD CIRCUIT PROTECTION |
High Voltage Cut-out, Low Voltage Cut-out ( Internal ) |
|||||||||||||
COMPRESSOR PROTECTION |
Auto-reset Overload Protector ( Internal ) |
|
|
|
|
|||||||||
REFRIGERANT CIRCUIT PROTECTION |
Auto-reset High Pressure Control Switch |
|
|
|
|
|||||||||
LOW WATER PROTECTION |
Float Switch |
|
|
|
|
|
|
|
|
|
|
|||
|
ACCESSORIES - SUPPLIED |
N/A |
|
|
|
|
|
|
|
|
|
|
||
|
- REQUIRED |
Ice Storage Bin |
|
|
|
|
|
|
|
|
||||
OPERATION CONDITIONS |
VOLTAGE RANGE |
|
|
187 - 253 V |
|
|
|
|
||||||
|
|
|
AMBIENT TEMP. |
|
|
45 - 100° F |
|
|
|
|
||||
|
|
|
WATER SUPPLY TEMP. |
|
|
45 - 90° F |
|
|
|
|
||||
|
|
|
WATER SUPPLY PRESS. |
10 - 113 PSIG |
We reserve the right to make changes in specifications and design without prior notice.
9
6. KM-1300SRF3 (Remote air-cooled)
AC SUPPLY VOLTAGE |
208-230/60/3 |
|
|
|
|
|
|
|
|
|
|||||||
AMPERAGE |
10.8 A ( 5 min. freeze AT 104° F / WT 80° F ) |
||||||||||||||||
MINIMUM CIRCUIT AMPACITY |
20A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
MAXIMUM FUSE SIZE |
|
20A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
APPROX. ICE PRODUCTION REFERENCE |
Ambient |
|
|
|
Water Temp. (°F) |
|
|
||||||||||
PER 24 HR. |
Temp. (°F) |
|
|
|
50 |
|
70 |
|
90 |
|
|
||||||
|
lbs./day ( kg./day ) |
70 |
|
|
|
|
*1308 (593) |
|
1282 (581) |
|
1203 (546) |
|
|
||||
|
Reference without *marks |
80 |
|
|
|
|
1288 (584) |
|
1247 (566) |
|
1145 (520) |
|
|
||||
|
|
|
90 |
|
|
|
|
1282 (581) |
|
*1218 (552) |
|
1125 (510) |
|
|
|||
|
|
|
100 |
|
|
|
|
1252 (568) |
|
1196 (543) |
|
*1039 (471) |
|
|
|||
SHAPE OF ICE |
Crescent Cube |
|
|
|
|
|
|
|
|
|
|||||||
ICE PRODUCTION PER CYCLE |
30.1 lbs. ( 13.7 kg. ) 1440 pcs. |
|
|
|
|
|
|||||||||||
APPROXIMATE STORAGE CAPACITY |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
ELECTRIC & WATER CONSUMPTION |
90°F/70°F |
|
|
70°F/50°F |
|
|
|
|
|
||||||||
|
ELECTRIC W ( KWH/100 lbs. ) |
2300 ( 4.53 )2270 ( 4.17 ) |
|
|
|
|
|
|
|||||||||
|
WATER gal./24 HR. ( gal./100 lbs. ) |
252 ( 20.7 ) |
|
|
463 ( 35.4 ) |
|
|
|
|
|
|||||||
EXTERIOR DIMENSIONS ( WxDxH ) |
48" x 27 |
3 |
¦ " x 27 |
3 |
¦ " ( 1219 x 695 x 695 mm. ) |
|
|||||||||||
|
|
|
|
|
8 |
|
|
8 |
|
|
|
|
|
|
|
||
EXTERIOR FINISH |
Stainless steel, Galvanized Steel (Rear) |
||||||||||||||||
WEIGHT |
Net 255 lbs. ( 116 kg. ) |
Shipping 315 lbs. ( 143 kg. ) |
|||||||||||||||
CONNECTIONS - ELECTRIC |
Permanent Connection |
|
|
|
|
|
|
|
|||||||||
|
- WATER SUPPLY |
Inlet |
1¦2" FPT |
|
|
|
|
|
|
|
|
|
|||||
|
- DRAIN |
Outlet |
3¦4" FPT |
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
3 |
¦ " ID Pipe |
|
|
|
|
|
|
|
|||||
|
|
|
|
|
8 |
|
|
|
|
|
|
|
|
|
|
|
|
CUBE CONTROL SYSTEM |
Float Switch |
|
|
|
|
|
|
|
|
|
|
||||||
HARVESTING CONTROL SYSTEM |
Hot Gas and Water, Thermistor and Timer |
||||||||||||||||
ICE MAKING WATER CONTROL |
Timer Controlled, Overflow Pipe |
|
|
|
|
|
|||||||||||
COOLING WATER CONTROL |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
BIN CONTROL SYSTEM |
Thermostat |
|
|
|
|
|
|
|
|
|
|
||||||
COMPRESSOR |
Hermetic, Model CS14K6E-TF5 |
|
|
|
|
|
|||||||||||
CONDENSER |
Air-cooled remote, Condenser Unit URC-12F |
||||||||||||||||
|
|
|
recommended |
|
|
|
|
|
|
|
|
|
|||||
EVAPORATOR |
Vertical type, Stainless Steel and Copper |
||||||||||||||||
REFRIGERANT CONTROL |
Thermostatic Expansion Valve, |
|
|
|
|
|
|||||||||||
|
|
|
Condensing Pressure Regulator on URC-12F |
||||||||||||||
REFRIGERANT CHARGE |
R404A, 11 lbs. 7 oz. ( 5200 g. ) |
|
|
|
|
||||||||||||
|
|
|
( Ice maker 7 lbs.; Cond. unit 4 lbs. 7 oz. ) |
||||||||||||||
DESIGN PRESSURE |
HIGH 467 PSIG, LOW 230 PSIG |
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
||||||||||
P.C. BOARD CIRCUIT PROTECTION |
High Voltage Cut-out ( Internal ) |
|
|
|
|
|
|||||||||||
COMPRESSOR PROTECTION |
Auto-reset Overload Protector ( Internal ) |
||||||||||||||||
REFRIGERANT CIRCUIT PROTECTION |
Auto-reset High Pressure Control Switch |
||||||||||||||||
LOW WATER PROTECTION |
Float Switch |
|
|
|
|
|
|
|
|
|
|
||||||
ACCESSORIES - SUPPLIED |
N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
- REQUIRED |
Ice Storage Bin, Remote Condenser Unit |
|||||||||||||||
OPERATION CONDITIONS |
VOLTAGE RANGE |
|
|
187 - 264 V |
|
||||||||||||
|
|
|
AMBIENT TEMP. |
|
|
45 - 100° F |
|||||||||||
|
|
|
WATER SUPPLY TEMP. |
|
|
45 - |
90° F |
||||||||||
|
|
|
WATER SUPPLY PRESS. |
10 - 113 PSIG |
We reserve the right to make changes in specifications and design without prior notice.
10
7. CONDENSING UNIT
URC-12F
11
SPECIFICATIONS
MODEL: URC-12F
EXTERIOR
DIMENSIONS (W x D x H)
REFRIGERANT CHARGE
URC-12F
WEIGHT
CONNECTIONS
REFRIGERANT
ELECTRICAL
CONDENSER
HEAD PRESSURE CONTROL
AMBIENT CONDITION
Galvanized Steel
35 - 11/16” x 15-11/16” x 21-15/16” (907.2 x 398 x 557.8 mm)
R404A 4 lbs. 7 oz. (2000 g)
Net 80 lbs. (36 kg)
Shipping 87 lbs. (39 kg)
One Shot Couplings (Aeroquip)
Permanent Connection
Air-cooled
Condensing Pressure Regulator
Min. -20°F - Max. +122°F (-29°C to +50°C) Outdoor use
12
II. GENERAL INFORMATION
1.CONSTRUCTION
[a]KM-1300SAF/3
13
[b] KM-1300SWF/3
14
[c] KM-1300SRF/3
15
2. CONTROLLER BOARD
[a] SOLID-STATE CONTROL
1)A HOSHIZAKI exclusive solid-state control is employed in KM-1300SAF,
KM-1300SWF, KM-1300SRF, KM-1300SAF3, KM-1300SWF3 and KM-1300SRF3 Stackable Crescent Cubers.
2)A Printed Circuit Board (hereafter called “Controller Board”) includes a stable and high quality control system.
3)All models are pretested and factory-adjusted.
[b] CONTROLLER BOARD
CAUTION
1.Fragile, handle very carefully.
2.A controller board contains integrated circuits, which are susceptible to failure due to static discharge. It is especially important to touch the metal part of the unit when handling or replacing the board.
3.Do not touch the electronic devices on the board or the back of the board to prevent damage to the board.
4.Do not change wiring and connections. Especially, never misconnect
K3, K4 and K5, because the same connector is used for the Thermistor and Float Switch. K4 is not connected.
5.Do not fix the electronic devices or parts on the board in the field. Always replace the whole board assembly when it goes bad.
6.Do not short out power supply to test for voltage.
16
KM-1300S_F/3 models use either the Alpine Controller Board (orange):
PART NUMBER |
TYPE |
2U0127-01 |
MY9KM910 (Alpine) |
|
MY9KM91B (Alpine) |
OR the Control Products Board (green): |
|
PART NUMBER |
TYPE |
2A0836-01 |
HOSHIZAKI 001 (Control Products - 8 Pin) |
OR the Control Products |
Improved “E” Board (green): |
PART NUMBER |
TYPE |
2A1410-01 |
HOS-001A (Control Products - 10 Pin) |
Features of All Three Controller Boards
(1)Maximum Water Supply Period - 6 minutes
Water Solenoid Valve opening, in the Defrost (Harvest) Cycle, is limited by maximum period of the defrost timer. The Water Valve cannot remain open longer than the maximum period. The Water Valve can close in less than the maximum period if the defrost cycle is completed.
(2)Defrost Timer
The defrost cycle starts when the Float Switch opens and completes the freeze cycle. But the Defrost Timer does not start counting until the Thermistor senses 48°F at the Evaporator outlet. The period from the end of the freeze cycle up to the point of the Thermistor's sensing varies depending on the ambient and water temperatures.
(3)High Temperature Safety - 127 ± 7°F
The temperature of the suction line in the refrigerant circuit is limited by the
High Temperature Safety.
During the defrost cycle the Evaporator temperature rises. The Thermistor senses 48°F and starts the Defrost Timer. After the Defrost Timer counts down to zero, the normal freeze cycle begins. If the Evaporator temperature continues to rise, the Thermistor will sense the rise in temperature and at 127
± 7°F the Thermistor operates the High Temperature Safety.
17
This High Temperature Safety shuts down the circuit and the icemaker automatically stops. To reset the safety, turn the power off and back on again.
This High Temperature Safety protects the unit from excessive temperature.
(4)Low Water Safety
If the Pump Motor is operated without water, the mechanical seal can fail. To prevent this type of failure, the Controller Board checks the position of the Float Switch at the end of the initial one minute water fill cycle and at the end of each defrost cycle.
If the Float Switch is in the up position (electrical circuit closed), the Controller Board changes to the ice making cycle. If the Float Switch is in the down position
(electrical circuit open), the Controller Board changes to a one minute water fill cycle before starting the ice making cycle. This method allows for a Low Water
Safety shut down to protect the Water Pump from mechanical seal failure.
For water-cooled model, if the water is shut off, the unit is protected by the High
Pressure Switch.
(5)High Voltage Cut-out
The maximum allowable supply voltage of this icemaker is limited by the High Voltage Cut-out.
If miswiring causes excessive voltage on the Controller Board, the High Voltage
Cut-out shuts down the circuit in 3 seconds and the icemaker automatically stops.
When the proper supply voltage is resumed, the icemaker automatically starts running again.
18
Connector K1
Pins #1 through #10
#1, 9 Magnetic Contactor
#2 Hot Gas Valve
#3 Line Valve
#4 Pump Motor (icemaking)
#5 Pump Motor (drain)
#6 Water Valve
#7, 10 Power (line, Bin Control)
#8 Open
Dip Switch
Defrost Timer, Drain Timer
& Drain Counter
Connector K5
Float Switch
Connector K4 Open
(not connected)
Connector K3 Defrost Control
(Thermistor)
(Alpine “C”/Alpine Board)
19
Features of Control Products “E” Controller Board
The “E” board includes LED lights and audible alarm safeties. The red LED indicates proper control voltage and will remain on unless a control voltage problem occurs. At startup a 5 second delay occurs while the board conducts an internal timer check. A short beep occurs when the power switch is turned ON or OFF.
The green LED’s 1-4 represent the corresponding relays and energize and sequence 5 seconds from initial startup as follows:
Sequence Step |
LED’s on |
Length: Min. |
Max. |
Avg. |
1 Minute Fill Cycle |
LED4 |
|
|
60 sec. |
Harvest Cycle |
LED1, 4, & 2 |
2 min. |
20 min. |
3-5 min. |
Freeze Cycle |
LED1 |
5 min. |
60 min. |
30-35 min. |
Reverse Pump Out |
LED1, 3, & 2 |
10 sec. |
20 sec. |
Factory set. |
{LED 1 – Comp; LED 2 - HGV/CFM; |
LED 3 – PM; LED 4 - WV} |
|
The built in safeties shut down the unit and have alarms as follows:
1 beep every 3 sec. = High Evaporator Temperature >127 ° F.
Check for defrost problem (stuck HGV or relay), hot water entering unit, stuck headmaster, or shorted thermistor.
2 beeps every 3 sec. = Defrost Back Up Timer. Defrost >20 minutes. Orange LED marked 20 MIN energizes.
Check for open thermistor, HGV not opening, TXV leaking by, low charge, or inefficient compressor.
3 beeps every 3 sec. = Freeze Back Up Timer. Freeze > 60 minutes. Yellow LED marked 60 MIN energizes.
Check for F/S stuck closed (up), WV leaking by, HGV leaking by, TXV not feeding properly, low charge, or inefficient compressor.
To manually reset the above safeties, depress white alarm reset button with the power supply ON.
6 beeps every 3 sec. = Low Voltage. Voltage is 92 Vac or less.
7 beeps every 3 sec. = High Voltage. Control voltage > 147Vac ±5%. The red LED will de-energize if voltage protection operates.
The voltage safety automatically resets when voltage is corrected.
The Output Test switch “S3” provides a relay sequence test. With power OFF, place S3 on and switch power to ICE. The correct lighting sequence should be none, 2, 3, 4, 1, & 4, normal sequence every 5 seconds. S3 should remain in the “OFF” position for normal operation.
The application switch located between relay X3 & X4 must be set to match the original board application. Place this switch in the ALP position if there is no white wire supplied to the K1 connector. If there is a white wire, place the switch in the C position. If this switch is placed in the wrong position either the compressor contactor will remain energized with the control switch OFF or the unit will not start.
The dip switches should be adjusted per the adjustment chart published in the Tech Specs book. 7 & 8 must remain in the OFF position.
20
(Control Products HOSHIZAKI001 Board)
21
(Control Products HOS-001A Board)
22
[c] SEQUENCE
1st Cycle [KM-1300SAF/3, KM-1300SWF/3 and KM-1300SRF/3]
1. Unit energized and Control Switch to “ICE” |
|
3. Thermistor reads 48°F. |
|
position. Water supply cycle starts. |
|
Defrost Timer starts counting. |
|
|
|
|
|
|
|
|
|
|
|
|
|
limited
5.After the first 5 minutes in freeze cycle. Ready to complete freeze cycle when Float Switch circuit opens.
IMPORTANT
Board never accepts freeze completion signal within the first 5 minutes in freeze cycle.
4.Defrost Timer stops counting.
Defrost cycle is completed and freeze cycle starts.
IMPORTANT
1.Board never accepts defrost completion signal within the first 2 minutes in defrost cycle.
2.Defrost cycle time is limited to 20 minutes even if Defrost Timer does not stop counting.
23