Honeywell vk41, vk81 Handbook

PRODUCT HANDBOOK
1 EN2R-9004 0606R20-NE
Subject to change without notice. All rights reserved.
VK41../VK81..SERIES
GAS CONTROLS FOR COMBINED VALVE AND IGNITION SYSTEM
APPLICATION
The Combined Valve and Ignition (CVI) system has been developed for application in gas fired domestic central heating boilers, combi boilers and warm air furnaces or water heater appliances with an automatic ignition system.
For this system, the VK41../VK81.. series gas controls have been designed to have the S4565/S4575/S4585 series ignition control attached directly on to the valve.
The combined system then provides programmed safe light up, flame supervision and regulation of gas flow to the main burner and/or pilot burner of the appliance.
The VK41.5/VK81.5 series gas controls (without pilot outlet) can also be used alone in direct burner ignition applications. A plug (order number 45.900.441- ) with integrated rectifier circuit then has to be used on the gas control.
Contents
General page
Description ...................................................................... 2
Features .......................................................................... 3
Dimesional ..................................................................... 4
Application ...................................................................... 6
Technical
Specifications .................................................................. 7
Electrical data .............................................................. 10
Capacity curves ....................................................... 13-18
Performance characteristics .......................................... 19
Installation ..................................................................... 21
Electrical connections and wiring .................................. 24
Adjustments and checkout ............................................ 25
Construction and working principles ............................. 26
Various
Quality assurance statement ......................................... 29
Standards and approvals .............................................. 30
Ordering information ..................................................... 31
Replacement parts and accessories ............................. 32
EN2R-9004 0606R20-NE 2
DESCRIPTION
Valves
The Combined Valve and Ignition (CVI) system controls and performs all the functions required for safe ignition, flame supervision and for safely regulating the gas flow to the pilot and/or main burner.
The CVI consists of a gas valve of the VK41../VK81.. series and a dedicated ignition control of the series S4565/S4575/ S4585 which is connected directly on to it.
The gas control comprises a standard body to which a range of features can be factory included to give various functional options. These functional options include: servo pressure regulation, throttle valve regulation, fully adjustable
SOFTLITE,
gas/air control 1:1 or amplified, electrical high-low or modulating control to fulfil the complete range of control applications.
The gas control has a first direct on/off operator for opening the safety valve of class B according to EN 161 and a second electric on/off servo operator for control of the main valve of class B,C or J according to EN 161 (for explanation class J, see chapter Standards and approvals page 30).
The pressure regulator is in accordance with class B requirements of EN 88
The gas control can handle the three gas families, manufactured gas, natural gas and LP gas.
General
All measurements are carried out under standard conditions listed below unless otherwise is indicated.
Standard conditions
P
inlet
25 mbar nominal pressure, dry air of 20°C
P
ambient
1013 mbar
T
ambient
20°C
Outlet orifice 2.8 mm
Flow indication in m
3
/
h
Recording of outlet pressure with a transducer connected to a
1
/2” pipe with a length of 10 times the diameter of the pipe with a short hose at a length of 5 times the diameter of the pipe.
Nominal voltage
Upright position, i.e. the position when the operators are on
top.
3 EN2R-9004 0606R20-NE
FEATURES
General
All burner control safety functions concentrated in one reli­able and optimized system.
Specially designed to provide the optimum system solution in gas appliances with a DBI or IP system to light the main burner.
Both gas control and ignition control incorporate time proven design concepts assuring reliability.
ON/OFF control of main burner by electric operator and electric servo operator directly energized from ignition con­trol.
Easy assembly of ignition control on gas control by plug­ging it on from the top.
Mounting orientation may be within 90
°
in any direction
from the electric on/off operator upright position.
Gas control
Inlet 18.6 mm and outlet 18.6 mm connections are straight through and can receive flanges.
The following closing force models are available: B + J; B + C; B + B.
Servo pressure regulator provides stable outlet pressure.
Pressure feedback ensures constant burner pressure in
relation to combustion chamber pressure.
All adjustments are accessible from the top.
9 mm diameter pressure taps on top face for checking inlet
and outlet pressure
An internal fine mesh screen is incorporated at the inlet of the gas control. This screen is not removable for cleaning.
An outlet screen is optional.
Two mounting holes for self tapping screws are at the bot-
tom of the gas control for rigid attachment to the appliance.
Functional options
Fast open and SOFTLITE versions
Fully adjustable
SOFTLITE option to facilitate the smooth
light-up of burner and for changing over from one gas to another.
NOTE:
SOFTLITE opening is not always available when the
second valve is classified as a class B valve.
100 mbar inlet pressure versions available on request
Throttle valve versions
Electrical modulation (Modureg) or CVI-m.
Electrical High-Low control.
Pilot outlet for IP system
Gas/Air ratio version available.
Gas connection options
Internal thread (ISO 7-1), external thread (ISO-R228) or flanged connections. See table 4, 5, 6 and 7, page 9.
Side outlet option for both main and pilot gas.
The side outlet for pilot and main gas can only be con-
nected to a flanged burner manifold.
Pilot gas connection for tubing with 4 mm outer diameter is located at the outlet end of the gas control.
Pressure feedback fittings for 4 or 6 mm silicon tube can be mounted.
End outlet or side outlet Quick connection for Mini Venturi
Electrical connection options
The appropriate ignition control can be connected to the valve by plugging it on.
Wired plug (IP 40) for connection with a remote ignition control.
Rectifier plug (IP 40) for use with any standard DBI ignition system.
24 Volt versions available for use in conjunction with other ignition controls than S4565/S4585 series.
EN2R-9004 0606R20-NE 4
DIMESIONAL DRAWING STANDARD CONNECTION
13.4
Pilot outlet M8 x 1-6H
for 4 mm tubing
24
Outlet
29.3
36.7
6.3 terminal (3)
148
VK.1..P/Q
(High/Low)
VK.1..A/C
(Standard regulator)
80
VK.1..E/T
(Throttle)
70
6.3 terminal (2)
148
VK.1..M/N
(Modureg)
24
Side outlet
Pressure tap (2)
Adjustable softlite
94.8
68.3
1
6
24.9
84.5
73
84.5
115
STEP
STEP
Hole Ø 2.6 to connect
ignition control
Throttle
Molex 1.1 square pin header
(mating connectors 3001 series)
113
17
12.5
25
Flange thread 1/2"
or 3/8" ISO7-1
16 mm full thread
VK.1..B/D
(Blank plate)
115
105
8
18
30
29.4
64.9
Mounting hole (2) for
tapping screws 3.9
DIN 7970
36.7
24.1
24
68.3
34.3
9.1
"0"-ring size
Ø 15.55 x Ø 15.55
M5 x 0.8(3)
6 mm full thread
Side outlet
(Optional)
Inlet
24
91
36.7
M4x0.7-6H(8)
6 min full thread
12
24
32
Ø 18.6
The cross hatched area
is sealing face without
imperfections
32
24
12
OUT
Earth terminal
21.9
IN
62
V1 V2
Tolerances according
to ISO 2768 mK
24
VK.1..M/N
(ModuPlus)
140
5 EN2R-9004 0606R20-NE
DIMESIONAL DRAWING EXTERNAL THREAD CONNECTION
Dimensional drawing VK41.5VE/VK81.5VE (Throttle)
8
15 ref
135
105
29.4
64.9
15
15
30
11.9
36.7
91
Inlet
20.7
30
G1/2" or G
3/4
"
13.4
1
OUT
MIN
V1 V2
IN
84.5
115
62
24.9
84.5
Hole Ø 2.6 to connect ignition control
Earth terminal
94.8
24
12
32
24
Pressure feedback connection
29.3
36.7
32
12
End outlet
The cross hatched area is sealing face without imperfections
80
113
Molex 1.1 square pin header (mating connecters 3001 series
Mounting hole (2) for tapping screws 3.9 according DIN 7970
Tolerances according to ISO 2768 mK
100
120
105
85
91
36,7
65
35,7
24,1
Throttle
Throttle screw
Throttle screw
29,3
EN2R-9004 0606R20-NE 6
APPLICATION
The VK41.. /VK81..series gas control have been specially developed for application in domestic appliances.
The VK41.. series gas control can be used in a system in conjunction with a S4565, S4575 or S4585 series ignition control to provide an optimised safety sub-system for programmed safe light-up and flame supervision of the main burner.
When connected with a Honeywell specified rectifier plug and lead the VK4105 series valve can be used with any standard 220/240 Vac DBI ignition system.
VK81.. series gas controls for 24 Vrac have been developed for application with other ignition controls with appropriate power supply.
7 EN2R-9004 0606R20-NE
SPECIFICATIONS
NOTE: Specifications for electrical modulation, electrical
high low, gas/air and other features are available on request.
Models
See model number chart on page 31
Main gas connection
Standard see table 4, page 9.
Optional see table 5, page 9.
Side outlet can be fitted direct to a flanged burner manifold.
Inlet and outlet with
3
/8” or 1/2” ISO 7-1 internal pipe thread
and straight or elbow flanges with
3
/8” or 1/2” ISO 7-1 internal pipe thread are according to the torsion and bending stress of EN126 group 2
Connections with G
1
/2” or G 3/4” external thread fitted with nuts according to ISO 228-1 in combination with applicable sealing(s) withstand the torsion and bending stress of EN 126 group 1
Ambient temperature
-15 ... 60°C
Humidity
95% RH max. at 40°C
Storage
- 30 ... 70°C
Pilot gas connection
Standard at end outlet: M8 x 1 for 4 mm outer diameter tubing.
Pressure feedback connection
The servo pressure regulator has an M5 thread connection for pressure feedback. Pressure feedback fittings for 4 or 6 mm silicon tube can be mounted as option.
Dime nsions
See page 4 and 5
Outlet pressure range for ON/OFF regulators
1.5 ... 20 mbar 2 ... 37 mbar 5 ... 50 mbar
Minimum regulation capacity
0.31 m3/h air
Minimum differential pressure
Maximum operating pressure
The P
max
indication on the housing of the gas control is the maximum pressure at which it functions safely. However, the maximum inlet pressure is limited by the pressure range of the pressure regulator concerned. (See table 2.)
* This type can also be used for non regulation mode in LP
applications when pressure regulator adjustment screw is clockwise turned down until it stops.
Versions up to 100 mbar maximum inlet pressure are available on request
Mounting holes
Two mounting holes for thread forming M4 screws are located on the bottom of the gas control.
For versions with external thread there are two additional mounting holes for thread forming screws at the inlet side of the gas control.
The four holes at inlet and outlet for mounting a flange on the gas control are provided with M4 thread with min. 6 mm full thread.
In case of side outlet the three holes for mounting the flange are provided with M5 thread with a minimum of 6 mm full thread.
Table 1: Minimum differential pressure
Model P min (mbar)
VK4105 2.5
VK4115 4
VK4125 4
Table 2: Operating pressure
Model Pressure range
(mbar)
Maximum inlet pressure (mbar)
with regulation 1.5 ... 20
2 ... 37* 5 ... 50*
30 45 60
without regulation - 60
EN2R-9004 0606R20-NE 8
Capacity
In m3/h air at pressure drop as shown below. See also the capacity curves concerned.
NOTE 1.: Versions with side outlet connection have a 0.2 m
3
/h air lower capacity. NOTE 2.: Increased capacity versions are optional for types with suffix letter E, T and V. NOTE 3.:
3
/4“ external thread versions have a 0.3 m3/h air lower capacity.
Model Extention P (mbar) Capacity (m3/h air) Capacit y curve
Number Page
VK410X/VK810X A, B, C, D, M, N, P, Q 3 3.4 H 10 13
E, T 3 2.8 H 160 17
VK411x/VK811x A, B, C, D, M, N, P, Q 5 4.4 H 20 14
E, T 5 3 H 170 18
V, VE 5 3.4 H 140 15
10 5.1
VB 5 4.4 H 20 14
VK412X A, B, C, D, M, N, P, Q 5 2.2 H 150 16
VK412X /VK812X V 5 2.2 H 150 16
10 5.1
Table 3: Valve classification
Model
1
st
valve 2nd valve
Classification Backpressure (mbar) Classification Backpressure (mbar)
VK4100/VK4105 VK8100/VK8105
B50J 0
VK4110/VK4115 VK8110/VK8115
B50C10
VK4120/VK4125 VK8120/VK8125
B50B50
9 EN2R-9004 0606R20-NE
Table 6: Mini-Venturi valve connection
Table 7: Throttle valve (VK....VE only) connection
Table 4: Standard valve connection
Inlet End outlet Side outlet Body length
(mm)
Flanged Flanged -- 105
Flanged -- Flanged 105
Internal
3
/8”
ISO 7-1
-- Flanged 115
Internal
1
/2”
ISO 7-1
-- Flanged 115
Internal
1
/2”
ISO 7-1
Internal 1/2” ISO 7-1
-- 115
Table 5: External valve connection (optional)
Inlet End outlet Side outlet Body length
(mm)
G
1
/2”G
1
/2”-- 135
G
1
/2” Flanged -- 120
G
3
/4”G
3
/4”-- 135
G
3
/4” Flanged -- 120
G
3
/4” -- Flanged 120
G
3
/4” Internal 11/2”
ISO 7-1
-- 120
G
1
/2” -- Flanged 120
Flanged G
1
/2”-- 120
Flanged G
3
/4”-- 120
Inlet End outlet Side outlet Body
length (mm)
Flanged Quick connect
mini-venturi
-120
Flanged - Quick connect
mini-venturi
105
G
3
/4” Quick connect
mini-venturi
-135
G
3
/4” - Quick connect
mini-venturi
120
Inlet End outlet Side outlet Body length
(mm)
Flanged Flanged -- 105
G
1
/2” Flanged -- 120
G
3
/4” Flanged -- 120
EN2R-9004 0606R20-NE 10
ELECTRICAL DATA
Table 8: Electrical connection for Direct Burner Ignition systems
Supply voltage Coil indication Rectifier circuit
position
Coil connection ( fig. 1 ) Valve indication
24 Vac, 50/60 Hz 24 Vrac External Series connection pin1 and pin 5 or
plug 45.900.441-029
VK 81.5
24 Vac, 50/60 Hz 24 Vrac In plug Select plug 45.900.441- with rectifier
(See table 11)
VK 81.5
100 Vac, 50/60 Hz 100 Vrac External Series connection pin1 and pin 5 VK 41.5
110 Vac, 50/60 Hz 110 Vrac In S4575 Select plug 45.900.441-033
without rectifier (See table 11)
VK 41.5
In plug Select plug 45.900.441-039
(See table 11)
VK 41.5
External Series connection pin1 and pin 5 VK 41.5
220 ... 240 Vac, 50/60 Hz 220 ... 240 Vrac In S4565 Select plug 45.900.441-033
without rectifier (See table 11)
VK 41.5
In plug Select plug 45.900.441- with rectifier
(See table 11)
VK 41.5
External Series connection pin1 and pin 5 VK 41.5
Table 9: Electrical connection for Intermittent Pilot ignition systems
Supply voltage Coil indication Rectifier circuit
position
Coil connection ( fig. 1 ) Valve indication
24 Vac, 50/60 Hz 24 Vrac External Parallel connection pin1/2 and pin 4/5 VK 81.0
220 ... 240 Vac, 50/60 Hz 220 ... 240 Vrac In S4565 and
S4585 types
S4565 and S4585 types VK 41.0
220 ... 240 Vac, 50/60 Hz 220 ... 240 Vrac External Parallel connection pin1/2 and pin 4/5 VK 41.0
Table 10: Power consumption (W) and current (mA)
Supply voltage Power consumption Current
Nominal voltage 110% nominal voltage Nominal voltage 110% nominal voltage
1
st
operator
1
st
+ 2
nd
operator
1
st
operator
1
st
+ 2
nd
operator
1
st
operator
1
st
+ 2
nd
operator
1
st
operator
1
st
+ 2
nd
operator
DBI system
24 Vac, 50/60Hz -- 9.2 -- 11 -- 424 -- 466
100 Vac, 50/60Hz -- 9.75 -- 11.9 -- 105 -- 115
110 Vac, 50/60Hz -- 8.8 -- 10.8 -- 89 -- 98
220 Vac, 50/60Hz -- 9.4 -- 11.4 -- 48 -- 52
240 Vac, 50/60Hz -- 11.2 -- 13.6 -- 52 -- 57
IP system
24 Vac, 50/60Hz 6.7 6.7 + 3.1 8.0 8.0 + 3.7 309 309 + 143 340 157
220 Vac, 50/60Hz 9.1 4.8 11 5.8 46 24 51 27
240 Vac, 50/60Hz 10.9 5.7 13.1 6.9 50 26 55 29
220Vac, 50/60Hz 7 7 + 2.2 8.3 8.3 + 2.7 31 31 + 11 35 35 + 12.2
240 Vac, 50/60Hz 8.0 8.0 + 2.6 9.6 9.6 + 3.2 35 35 + 12.1 38.4 38.4 + 13.3
11 EN2R-9004 0606R20-NE
Fig. 1. Coil connection
Rectifier plug
The 220/240 V,110V and 24 V versions of the VK4105/ VK8105 series gas controls can be connected to any standard DBI control with a 220/240 Vac, 110V or 24 Vac output by using a rectifier plug 45.900.441- See table 11.
Electical protection of gas control with rectifier plug
IP 40
Mounting of rectifier plug
fig. 2 .
Mounting screw
Torque: 40 Ncm max.
Fig. 2. Mounting of rectifier plug
IMPORTANTIMPORTANT
Warranty claims are not accepted if not the specified plug/rectifier circuit is used.
V1
1Pin number 2 3 4 5
V2
Loading...