Honeywell VISTA-250BPT Specsheet

Control Panels
VISTA-250BPT
VISTA® Partitioned Commercial Burglary Alarm
Control Panels
The VISTA-250BPT is a powerful member of the Honeywell
Home family of commercial alarm panels, integrating burglary,
CCTV and access control functions. Many features are available
that extend the applications of the VISTA-250BPT while simplifying
end-user operation.
and commercial burglary applications (see agency listings in
this document for more details). It is compatible with a wide range
of AlarmNet® communications products for alarm reporting,
uploading/downloading and remote services.
FEATURES
• Provides nine onboard st yle-B
hardwired zones
• Supports up to 241 additional zones
using a built-in polling (multiplex)
loop interface
• Supports up to 249 wireless zones
using up to two 580 0 Series wireless
receivers (fewer if using hardwired
and/or polling loop zones)
• Provides 1 power-limited bell circuit
delivering 1.7Amp (max) at 12VDC
• Provides the ability to control eight
separate partitions independently,
each functioning as if it had its own
separate control
• Accommodates 250 user codes with
seven authority levels per partition
• Accommodates 32 keypad macro
commands per system
• Keeps a log of up to 1,000 events
• Optiflex CCTV support
• Supports up to 16 two-wire smoke
detectors on zone 1
• Zone 7 may be used for keyswitch
arming/disarming
®
• Integrates with WIN-PAK
control systems to provide increased
users, event log and scheduling
®
• Supports V-Plex
VISTAKEY access control (up to
15 doors and 500 cards)
• Supports up to 96
programmable outputs
• Supports up to six touchscreen
Advanced User Interface (AUI)
devices (6272 or later)
• Smoke detector reset at keypad
• Quick exit
• Group bypass
• Arm faulted
• Event arming
addressable
access
• Carbon monoxide (CO)
zone type support
• Expanded high-speed RS-232
capability for third party interface
and automation
• Internet upload/download over
AlarmNet GSM and/or IP
communicators over the panel’s
keypad (ECP) bus
• Ringback support for AlarmNet
communicators (confirmation
of closing report)
• 24 -hour dialer test support
for AlarmNet devices
• Supports V-Plex Smart Contact
feature for improved responsiveness
on systems with many V-Plex zones
• Telco line cut detection
VISTA-250BPT
VISTA® Partitioned Commercial Burglary Alarm Control Panels
ADDITIONAL FEATURES
Basic Hardwired Zones
• EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations)
• Individually assignable to one of eight partitions
• Up to 16 two-wire smoke detectors on zone 1
• Four-wire smoke or heat detectors on zones 1-8 (power to four-wire smoke detectors must be super vised with an EOL device). Listed for residential fire only.
Polling Loop Expansion
Supports up to 241 additional zones
using a built-in polling (multiplex) loop interface. Polling loop zones have the following characteristics:
• Must use V-Plex devices
• Supervised by control panel
• Individually assignable to one of eight partitions
• Supports VSI module
• Supports 4297 Expander Module
• Maximum wiring distance - 12,00 0 feet
Wireless Expansion
• Supports up to 249 wireless zones using up to two 5800 Series wireless
receivers (fewer if using hardwire and/or polling loop zones).
Wireless zones have the following characteristics:
• Supervised by control panel for check-in signals (except certain nonsupervised transmitters)
• Tamper protection for supervised transmitters
• Individually assignable to one of eight partitions
Scheduling
Provides the following scheduling capabilities:
• Open/Close Schedules (for control of arming/disarming and reporting)
• Holiday Schedules (allows different time windows for open/close schedules)
• Timed Events (for activation of relays, auto-bypassing and unbypassing, auto-arming and disarming, etc.)
• Access Schedules (for limiting system access to users by time)
Eight Partitions
• Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control
Partitioning features include:
• A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed, and to disarm when the first partition that shares the common lobby is disarmed
• A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads)
• All zones assignable to one of eight partitions
• Keypads assignable to one of eight partitions or to Master partition 9 to view system status
• Abilit y to assign relays to one or all eight partitions
• Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions’ keypads (selectable option)
• Individually programmable account number, entry delay and exit delay by partition
V-Plex Loop
4101SN
Relay Module
NOTE: Please refer to the website (www. security.honeywellhome.com/hsc) for the latest product information.
DT7500SN
V-Plex DUAL TEC
Motion Sensor
FG1625SN Glassbreak
PC ConnectionSerial Printer
4208EX Eight-zone
V-Plex Expander and
4208SN Serialized Eight-
zone Remote Point Module
710
Strobe
Light
748
RS-232
Horn
4293SN Adapters
Notification
Appliances
VISTA-250BPT
ECP Bus
7847i
Series Smoke Detectors
6160
Console
Keyswitch
Option
4146
or
GSMV
5193
4204 Relay
Module
Phone Line to Central Station
or
iGSMV
5881 Wireless Receiver