Motorized Zone Valves

V8044 Low Voltage Diverting Valves

Flare

Connection

On-off and diverting low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water.

Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored.

All models may be installed without disassembling the valve.

Compact construction for easy installation.

Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system.

Actuator motor may be replaced without removing the valve body or draining the system.

Sweat

Connection

NPT Connection

Application: Hydronic Control Type: Two position

Body Pattern: Three-way, Diverting

Valve Action: Spring Return Voltage: 24 Vac Frequency: 50 Hz; 60 Hz

Power Consumption: 7.7 VA

De-energized Position: Port A Normally Closed Electrical Connections: 18 in. leads (457 mm leads) Fluid Temperature Range: 40 F to 200 F (5 C to 93 C) Maximum Ambient Temperature: 125 F (52 C)

Comments: Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water.

Valve designed for cycling (not constantly powered on) applications.

Materials (Body): Brass

(Stem): Stainless Steel

(Seat): Brass

(Packing O-Ring): EPDM rubber

(Ball Plug): Buna-N (NBR) Rubber Ball

Approvals

Underwriters Laboratories, Inc: UL Listed: File MH11826

Replacement Parts:

802360JA-24V, 50/60 Hz Replacement motor for V8043, V8044 Zone Valves

802360UA-24V, 50/60 Hz Replacement motor for steam and heating Replacement Parts:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Close-

 

 

 

 

Capacity

 

Pipe Size

Connection

Auxiliary

off Pressure

Current

 

Manual

 

 

 

 

 

 

 

 

 

Product Number

(Cv)

 

(Kv)

inch

DN

Type

End Switch

(psi)

(kPa)

Draw (A)

Includes

Opener

 

 

 

 

 

 

 

 

 

 

 

 

 

V8044A1002/U

4 Cv

 

3.4 Kv

1/2 in.

DN15

Flare

20 psi

138 kPa

0.32A

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

V8044A1010/U

4 Cv

 

3.4 Kv

1/2 in.

DN15

Sweat

20 psi

138 kPa

0.32A

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

V8044A1044/U

7.0 Cv

 

6 Kv

3/4 in.

DN20

Sweat

10 psi

69 kPa

0.32A

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

V8044A1051/U

4 Cv

 

3.4 Kv

1/2 in.

DN15

Sweat

20 psi

138 kPa

0.32A

Restricted 2.5 Cv

Yes

 

 

 

 

 

 

 

 

 

 

 

bypass port.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V8044A1135/U

4 Cv

 

3.4 Kv

1/2 in.

DN15

NPT

20 psi

138 kPa

0.32A

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

V8044A1143/U

4 Cv

 

3.4 Kv

3/4 in.

DN20

NPT

20 psi

138 kPa

0.32A

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

V8044B1018/U

4 Cv

 

3.4 Kv

1/2 in.

DN15

Sweat

20 psi

138 kPa

0.32A

Integral SPDT

Yes

 

 

 

 

 

 

 

 

 

 

 

changeover

 

 

 

 

 

 

 

 

 

 

 

 

Aquastat controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V8044E1003/U

4 Cv

 

3.4 Kv

1/2 in.

DN15

Sweat

N.O. SPST

20 psi

138 kPa

0.32A

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

V8044E1011/U

7.0 Cv

 

6 Kv

3/4 in.

DN20

Sweat

N.O. SPST

10 psi

69 kPa

0.32A

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

210