(Remove the thermostat from its wallplate to find the model number.)
TH2110D and TH2210D
programmable thermostats
System Types
TH1110D and TH2110D:
• Central heating - gas, oil, electric or
high-efficiency furnac e (1H)
• Central heating (see above) with air
conditioning (1H/1C)
• Hot water system (steam or gravity) with or
without pump
• Central air conditioners
• 750 mV heating systems
• Heat pumps without auxiliary heating (1H/1C)
TH1210D and TH2210D:
• Heat pumps with auxiliary heating (2H/1C)
TH1100D:
• Central heating - gas, oil, el ectric or
high-efficiency furnace (1H)
• Hot water system (steam or gravity) with or
without pump
• 750 mV heating systems
ENGLISH
Must be installed by a trained, experienced technician
Read these instructions carefully. Failure to follow these instructions
can damage the product or cause a hazardous condition.
Need Help?
For assistance with this product please visit http://yourhome.honeywell.com
or call Honeywell Customer Care toll-free at 1-800-468-1502.
1
Installation Guide
Wallplate installation
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power
before beginning installation.
n Loosen the locking screw at the bottom of the thermostat. Note that the screw is
captive and cannot be removed from the wallplate.
o Separate the thermostat from the wallplate as per Figure 1.
p Position the wallplate against the wall and mark hole positions with a pencil.
NOTE: Levelling is for esthetics only and will not affect the performance of the
ENGLISH
thermostat.
q Drill holes at the marked positions and insert supplied wall anchors.
r Pass the wires through the large opening located at the bottom center of the wallplate
as per Figure 2.
s Secure the wallplate to the wall with supplied mounting screws as per Figure 3.
t Connect the wires to the terminals.
Figure 2
Figure 1
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube,
do not place the old control in the trash. Contact your local waste
management authority for instructions regarding recycling and proper
disposal.
2
Figure 3
PRO 1000 / 2000 Series
Wiring
Power supply. Provide disconnect means and overload protection as required.
Set the O/B jumper according to the type of reversing valve (see page 4).
Use a piece of wire (not supplied) to connect W and Y terminals to each other.
Optional 24 VAC common connection. If this connection is not made, use batteries
to power the thermostat.
This connection is not required for systems that provide heating only.
This connection is not required for systems that provide cooling only.
This connection is not required for systems that do not have an air recirculating fan.
Gas, oil or electric heating (1H)
ENGLISH
Heat
Gas, oil or electric heating and/or air conditioning (1H / 1C / 1H1C)
Compressor
Fan
Heat
Heat pump without auxiliary heating (1H1C)
Compressor
Fan
Reversing valve
Heat pump with auxiliary heating (2H1C)
Use
TH1100D
Use
TH1110D
or
TH2110D
Use
TH1110D
or
TH2110D
Compressor
Fan
Reversing valve
Auxiliary Heat
Use
TH1210D
or
TH2210D
3
Installation Guide
Reversing valve setting
NOTE: This setting is necessary only if the thermostat is connected to a heat pump.
The jumper is located on the back of the thermostat faceplate. Set it according to the type
of reversing (changeover) valve used by the heat pump.
• O (factory setting): The reversin g valve is energized when the System switch is set to
Cool (cooling mode).
• B: The reversing valve is energized when the System switch is set to Heat (heating
mode).
Incorrect jumper setting: The heat pump operation will be reversed; i.e., it will cool in
Heat mode and will heat in Cool mode.
Fan operation setting
ENGLISH
NOTE: This setting is not applicable if a fan is not connected to the G terminal.
A jumper, located on the back of the thermostat faceplate, determines how the fan operates
in Automatic mode. This jumper is not available on TH1100, TH1210D and TH2210D. On
these models, when the fan is placed in Automatic mode, it starts right away when there is
a call for heat or cool.
• HG (factory setting): Leave the jumper in this position for gas or oil heating systems. In this
position, the heating system controls the fan operation. When there is a call for heat, the fan
starts only when the air coming out of the vents is sufficiently warm. When there is a call for
cool, the fan starts right away.
• HE: Place the jumper to this position for heat pump or electric heating systems. In this
position, the thermostat activates the fan as soon as there is a call for heat or cool.
Incorrect jumper setting: An incorrect setting is noticeable in a gas or oil heating system.
When heating starts, you will initially feel cold air coming out of the vents as the fan is
running before the furnace has enough time to heat up the air.
Battery installation
If a 24-VAC common wire is connected to the C terminal, batteries are
optional and serve to provide backup power.
If a 24-VAC common wire is not connected to the C terminal, batteries
are necessary to power the thermostat.
Install 2 AAA batteries on the back of the thermostat faceplate as
shown.
Thermostat mounting
n Align the two brackets on the top of the thermostat with the
corresponding slots on the top of the wallplate.
o Push the faceplate against the wallplate.
p Tighten the screw at the bottom of the thermostat.
4
PRO 1000 / 2000 Series
Installer setup
Follow the procedure below to personalize and
configure the thermostat according to the heating/
cooling system.
n Press and simultaneously (for three
seconds) until the display appears as shown
on the right.
o Press or to change the option.
p Press and for one second to advance t o
the next function.
Function
number
Option
number
q When the last function is displayed, press
and for three seconds to save any changes
and exit the menu.
NOTE
: If you do not press any button for 60 seconds while you are in the setup menu, the thermostat
automatically saves any changes made and exits the menu . For programmabl e models only, at any
time you can save the changes and exit by pressing the
3
Default
setting
1
1
0
Function
1Temperature display form at0
2Time display format0
3Heating cycles per hour5
4Cooling cycles per hour32 to 6 cycles per hour
5
Compressor protection
6
Adaptive Intelligent Recovery
7
Application
1
Depending on your thermostat model or your system type, some functions are non-available or
non-applicable.
2
Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the
compressor to wait 5 minutes be fore restarting. During the wait time, the mess age Cool On or Heat On
flashes on the screen. When th e safe wait time has elapsed, the mess ag e stops flashing and the compressor
turns on.
3
Adaptive Intelligent R ecovery™ allows the thermostat to “learn” how long your furna ce or air conditioner
takes to reach the set temperature. Simply pro gram the desired times and desired temperatures into the
schedule. The thermostat will determine when to activate heating or cooling so that the desired temperature
is attained at the desired time.
4
In Indoor mode, the minimum setpoint is 40°F (5°C) for frost protection. In Garage mode, the minimum
setpoint is 35°F (1.5°C) for ene rgy savings.
1
2
4
Run
button.
Options
0: Fahrenheit
1: Celsius
0: 12-hour display
1: 24-hour display
2 to 6 cycles per hour
• 2: 30 min (steam, gravity)
• 3: 20 min (hot water, 90%+ high-efficiency furnace)
• 4: 15 min (gas or oil)
• 5: 12 min (gas or oil)
• 6: 10 min (electric)
0: Off
1: On
0: Off
1: On
0: Indoor mode: 40°F to 90°F (4.5°C to 32°C)
1: Garage mode: 35°F to 90°F (1.5°C to 32°C)
ENGLISH
5