Honeywell TG512, TG511, TG510, TG509 User Manual

TG509, TG510, TG511, TG512 Versaguard™
68-0104-4
Universal Thermostat Guards
PRODUCT DATA
FEATURES
Available in four sizes: mini, small, medium and large,
to fit virtually all thermostats.
Used in both new and existing applications.
Constructed of smoke-colored transparent
polycarbonate, off-white opaque polycarbonate, opaque plastic, clear plastic or off-white painted steel.
TG509
TG511D
TG510A
TG512B
GENERAL
The Versaguard™ Universal Thermostat Guards cover wall thermostats and protect against tampering, damage and unauthorized adjustment of thermostat settings.
Opaque plastic guards match commercial interior
decorating schemes.
Can be mounted on the wall or an exposed junction box.
Smoke-colored transparent or off-white opaque
polycarbonate ring base without wallplate, or opaque plastic wallplate and plastic ring base. All models include a guard cover, tumbler lock, two keys and a Honeywell logo insert.
TG509F,G models permit thermostat calibration
without ring base removal.
Provision for Honeywell logo (included with all models)
or OEM logo on guard cover.
Ideal for office areas, lobbies, supermarkets,
restaurants, clinics, hospitals, convenience stores, and similar applications.
Tamper-resistant lock; key can be removed only when
in the locked position.
Vertical or horizontal mount.
Guard base vents allow airflow for optimum
thermostat performance.
® U.S. Registered Trademark Copyright © 1996 Honeywell Inc. • All Rights Reserved
CONTENTS
General ............................................................................... 1
Features .............................................................................. 1
Specifications ...................................................................... 2
Ordering Information ........................................................... 2
Installation ........................................................................... 6
Checkout ............................................................................. 11
TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
SPECIFICATIONS
IMPORTANT
The specifications listed in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. For exact engineering specifications, contact your Honeywell representative.
TRADELINE® Models:
TRADELINE® models are selected and packaged for ease of stocking, ease of handling, and maximum replacement value.
TRADELINE® Models Available:
TG509F Versaguard™ Universal Thermostat Guard:
transparent polycarbonate cover (smoke tint) ring base and allen wrench.
TG509G Versaguard™ Universal Thermostat Guard:
opaque polycarbonate cover (off-white) ring base and allen wrench.
TG510A, TG511A, TG512A Versaguard™ Universal
Thermostat Guards: clear plastic cover, opaque plastic wallplate and clear plastic ring mounting base.
TG510B, TG511B, TG512B Versaguard™ Universal
Thermostat Guards: opaque plastic cover, opaque plastic wallplate and opaque plastic ring mounting base.
Standard Models:
TG510D, TG511D, TG512D Versaguard™ Universal Thermostat Guards: painted steel cover (off-white), opaque plastic wallplate and opaque plastic ring mounting base.
Additional Features:
TRADELINE® and Standard Versaguard™ Universal Thermostat Guards include Honeywell logo insert (field­installed), mounting template, screws, anchors and tumbler lock with two keys.
See Tables 1 and 2 for thermostat guard applications.
Accessory:
191990A Replacement Keys (2); can also be used with TG500 and TG502 Thermostat Guards.
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or your distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number, or specify:
1. Order number.
2. Transparent (smoke tint) or opaque (off-white) polycarbonate (TG509 models only), clear or opaque plastic, or painted steel cover (off-white).
3. Accessory.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Honeywell Home and Building Control Sales Office (check white pages of phone directory).
2. Home and Building Control Customer Relations Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitee, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0104—4
2
TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
Table 1. TG509 Thermostat Guard Applications. Table 2. TG510, TG511, TG512
Thermostat TG509 (Fig. 1)
HONEYWELL
TP970 TP971 TP972 TP973 TP974 T7660 TP9600 Series
JOHNSON
T4002 T4100 T4506 T4756 T5002
POWERS
TH192 TH193 TH194 TT184
ROBERTSHAW
Original
T12 T13 T18 T19 T23 T27 T32 T33 T34 T35
Uniline
2211 2212 2214 2216 2218
Thermostat HONEYWELL
T87/Q539 T451
T498 T631 T641 T651 T694 T810 T822 T834 T841 T874/Q674 T4039 T6051A T6052 T7047 T8034 T42 T92 T921 T7200 T7300/Q7300 T7400 T8082/Q682 T8085/Q682 T8090/Q682 T8195/Q682 T8600 T8601 T8602 T8603 T8611 T8621 T8624 T8631 TP970 W884 Y594
Thermostat Guard Applications.
TG510 (Fig. 2)
a
TG511 (Fig. 3)
b
b
a
TG512 (Fig. 4)
c
3
68-0104—4
TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
Table 2. TG510, TG511, TG512
Thermostat Guard Applications
Thermostat
TG510 (Fig. 2)
(Continued)
TG511 (Fig. 3)
.
TG512 (Fig. 4)
ITT GENERAL
T199 T80 T90 T91 T330 SERIES T340 SERIES
ENERSTAT
DSP100—DSP700 ET52 HC-7 HP-1 K3-WN K4-W MS-1N HP-2
ROBERTSHAW
TX400 500 SERIES 300-610 300-620 300-630 300-642
WHITE RODGERS
1C-30 1C-31 1C-70 1D-30 1D-35 1D-36 1E-30 1E-31 1E-35 1E-36 1E-56 1F-30 1F-56 1F-57 1F-58 1F-60 1F-62 1F-70
Table 2. TG510, TG511, TG512
Thermostat Guard Applications
Thermostat
TG510 (Fig. 2)
(Continued)
TG511 (Fig. 3)
.
TG512 (Fig. 4)
WHITE RODGERS
1F-72 1F-75 1F-76 1F-90 1F-91 1F-92 1F-93 1F-94 1F-95 1F-97
AMERICAN STABILIS
R-90 R-100 R-105 R-106 HP-1 HP-10 HP15/20/22 HP100 HP150/200/220 HP1000 HP1500/2000/3000 HP2001 SIMPLESTAT
COLUMBUS ELECTRIC
RSH-420A RSV-420 HPC SERIES
SECO
TA-2000 TM-1000 TM-1400
a
Use TG512 for thermostat wallplate with dealer logo.
b
Tu rn TG511 90 degrees to fit thermostat wallplate with dealer logo.
c
Fits T87F The Round® Thermostat with decorator wallplate.
68-0104—4
4
TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
RING BASE ONLY
C
B
A
MODEL NUMBER
TG510A 2-1/2 64 4-5/8 117 3-5/8 92 5-1/2 140 2-1/8
AFG
IN. IN. IN. IN. IN.MM
IN. MM
2-7/8 73
FRONT VIEW
D
E
SIDE VIEW
F
G
CBDE
IN. MM
102
4
MM
MM
Fig. 1. TG509 overall dimensions.
RING BASE ONLY
C
B
D
FRONT VIEW
F
MM MM
54
M15015
SIDE VIEW
A
MODEL NUMBER TG510A TG510B TG510D
AFG
IN. IN. IN.. IN. IN.MM 4-7/16 4-7/16 4-7/16
113 113 113
IN. MM 3-1/2 3-1/2 3-1/2
CBDE
IN. MM 89 89 89
3-1/2 3-1/2 3-1/2
89 89 89
Fig. 2. TG510 overall dimensions.
RING BASE ONLY
154 154 154
D
B
IN. MM 5-1/8 5-1/8 5-1/8
130 130 130
C
IN. MM 4-1/8 4-1/8 4-1/8
105 105 105
C
B
A
MODEL NUMBER IN. IN. IN. IN. IN.MM MM TG511A TG511B TG511D
6-1/16 6-1/16 6-1/16
E
MM
4-7/16
113
4-7/16
113
4-7/16
113
FRONT VIEW
E
5-1/16
129 129 129
7-1/2 7-1/2 7-3/8
5-1/16 5-1/16
G
5-7/8 5-7/8 5-11/16
MM 149 149 144
5-7/8 5-7/8 5-11/16
MM MM 149
2-1/2 2-1/2 2-7/16
64 64 62
149 144
M642C
SIDE VIEW
F
G
EADFG
MM 191 191 187
6-1/2 6-1/2 6-3/8
MM 165 165 162
2-15/16 2-15/16 2-7/8
MM
75 75 73
M643C
Fig. 3. TG511 overall dimensions.
5
68-0104—4
TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
RING BASE ONLY
C
D
B
A
MODEL NUMBER TG512A TG512B TG512D
ADFG
IN. IN. IN. IN. IN.MM MM MM MM MM 8-3/8 8-3/8 8-3/8
IN. IN.MMMM
213
7-3/8
213
7-3/8
213
7-3/8
187 187 187
4-7/8 4-7/8 4-7/8
CB
124 124 124
Fig. 4. TG512 overall dimensions.
INSTALLATION
When Installing this Product…
1. Read these instructions carefully. Failure to follow them could damage the product.
2. Check the dimensions given in the instructions and on the product to make sure the product is suitable for your application.
The Versaguard™ Universal Thermostat Guards can be used in new or existing thermostat applications. In existing thermostat applications, the guard can be installed without removing the thermostat from the wall. In these applications, the thermostat guard is used without the solid wallplate (only ring base and cover are used). In new thermostat applications, the guard can be used with or without the solid wallplate. The wallplate is typically used to cover mounting marks from the old thermostat.
Refer to the following sections for specific mounting procedures for thermostat guard applications.
Mount Thermostat Guard Without Wallplate (Fig. 5 and 6)
Place the ring base over the thermostat (and wallplate,
subbase or adaptor plate) on the wall.
Align the ring base with the thermostat and level
approximately.
Mark the four mounting holes.
FRONT VIEW
SIDE VIEW
F
5-7/8 5-7/8 5-7/8
149 149 149
9-3/4 9-3/4 9-5/8
E
E
248
7-1/4
184
3-3/8 248 244
7-1/4 7-1/8
184 180
3-3/8
3-1/4
86 86 83
G
M644C
Mount the guard cover by placing the hinged edge of
the guard cover on the ring base and swinging it down (horizontal mounting) or to the side (vertical mounting) until the guard cover is in place against the ring base. See Fig. 7.
Lock the thermostat guard by turning the key (provided)
counterclockwise. See Fig. 8. The key can be removed only in the locked position.
Remove the paper backing and clear protective cover
from the included monogram and place the monogram in the recessed area on the guard cover. See Fig. 9.
NOTE: The TG509F,G Thermostat Versaguards™ are
shipped with an allen wrench secured in the top notch of the ring base. When thermostat calibration is needed, remove the Versaguard cover and use the wrench to remove the top two allen screws in the thermostat cover. This allows servicing of the thermostat while the ring base is in place.
MOUNTING RING BASE
MOUNTING HOLES (4)
0
9
0
8
0
7
0
0
6
6
0
9
0
8
0
7
0
6
WALL
THERMOSTAT
COVER
FRONT OF DEVICE
NOTE: Do not use the four brass screws for mounting
the TG509. The brass screws are intended for models with wallplates only.
Mount the ring base on the wall using the four no. 6
sheet metal screws and four anchors provided as shown in Fig. 5 for the TG509 and Fig. 6 for the FG510, TG511 and TG512.
68-0104—4
RING BASE
MOUNTING SCREWS (4)
RING BASE
KEY RECESSED AREA
FOR MONOGRAM
Fig. 5. Mount TG509 ring base only in existing thermostat
applications. TG509 guard cover, lock, monogram area.
6
M15014
0 8
7
0
6
0
5
T
A
E
H
RING BASE
TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
COVER
WALL
THERMOSTAT
L
O
O
C
0
8
0
0 7
6
50
0
0
8
0
7
0
6
0
5
MOUNTING HOLES (4)
RING BASE
MOUNTING SCREWS (4)
M653B
Fig. 6. Mount TG510, TG511 and TG512 ring bases only in
existing thermostat applications.
RING BASE
COVER
M654A
KEY
Fig. 8. Lock thermostat guard
(TG510, TG511, TG512 shown).
REMOVE PAPER BACKING
MONOGRAM
REMOVE CLEAR PROTECTIVE COVER
M655
Fig. 7. Mount guard cover (TG510, TG511, TG512 shown).
1
PLACE MONOGRAM IN RECESSED AREA ON GUARD COVER
1 TURN MONOGRAM 90 DEGREES ON VERTICALLY MOUNTED GUARDS.
M656A
Fig. 9. Apply monogram to thermostat guard
(TG510, TG511, TG512 shown).
7
68-0104—4
TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
Mount Thermostat Guard With Wallplate
CAUTION
Disconnect power supply to prevent electrical shock or equipment damage.
Wall Mounting Front-wired Subbase (Fig. 10)
Place the thermostat subbase (or wallplate) on the
wallplate template and mark the mounting holes.
Locate the mounting holes on the guard wallplate using
the template as a guide.
Drill the required 5/32 in. mounting holes in the guard
wallplate.
NOTE: If the mounting hole pattern on the guard
wallplate does not match the pattern on the thermostat subbase or wallplate, drill additional mounting holes in the guard wallplate.
WALL
Mount the thermostat subbase (or wallplate) and the
guard wallplate to the wall using the 1-1/4 in. sheet metal screws provided with the thermostat. The guard wallplate must be placed between the thermostat subbase (or wallplate) and the wall. See Fig. 10.
Wire the thermostat subbase (or wallplate). Refer to the
installation instructions provided with the thermostat.
Mount the thermostat on the subbase (or wallplate) and
place the thermostat cover on the thermostat.
Mount the guard ring base over the thermostat,
subbase (wallplate) and guard wallplate.
Attach the ring base using four no. 6 sheet metal
screws or four anchors and screws (provided).
Mount the guard cover by placing the hinged edge of
the guard cover on the ring base and swinging it down (horizontal mounting) or to the side (vertical mounting) until the thermostat guard is in place against the ring base. See Fig. 7.
Lock the thermostat guard by turning the key (provided)
counterclockwise. See Fig. 8. The key can be removed only in the locked position.
Remove the paper backing and clear protective cover
from the included monogram and place the monogram in the recessed area on the guard cover. See Fig. 9.
GUARD WALLPLATE
A
E
H
0
5
T
SUBBASE
0
8
0
7
0
6
0
5
RING BASE
L
O
O
C
0
8
0
7
0
6
0
5
0
8
0
7
0
6
THERMOSTAT
MOUNTING HOLES (4)
68-0104—4
MOUNTING SCREWS (4)
Fig. 10. Mount guard wallplate and ring base on thermostat with front-wired subbase or wallplate.
8
M657B
TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
Back-wired Thermostat (Fig. 11)
Place the thermostat on the wallplate template and
mark the mounting holes.
Locate the mounting holes on the guard wallplate using
the template as a guide.
Drill the required 5/32 in. mounting holes in the guard
wallplate.
NOTE: If the mounting hole pattern on the guard
wallplate does not match the pattern on the thermostat, drill additional mounting holes in the guard wallplate.
Mount the smooth side of the guard wallplate facing the
thermostat and run the system wires through the wiring hole in the guard wallplate. The guard wallplate must be placed between the thermostat and the wall. See Fig. 11.
Back-wire the thermostat. Refer to the instructions
provided with the thermostat.
WALL
GUARD WALLPLATE
Mount the thermostat and the guard wallplate to the
wall using the 1-1/4 in. sheet metal screws provided with the thermostat. Make sure the guard wallplate is placed between the thermostat and the wall.
Place the thermostat cover on the thermostat.Mount the guard ring base over the thermostat and the
guard wallplate.
Attach the ring base using four 1-1/4 in. sheet metal
screws or four anchors and screws (provided).
Mount the guard cover by placing the hinged edge of
the guard cover on the ring base and swinging it down (horizontal mounting) or to the side (vertical mounting) until the guard cover snaps into place against the ring base. See Fig. 7.
Lock the thermostat guard by turning the key (provided)
counterclockwise. See Fig. 8. The key can be removed only in the locked position.
Remove the paper backing and clear protective cover
from the included monogram and place the monogram in the recessed area on the guard cover. See Fig. 9.
THERMOSTAT BASE
80 70 60 50
RING BASE
MOUNTING SCREWS (4)
CONNECT WIRES TO TERMINALS ON BACK OF THERMOSTAT BASE
THERMOSTAT COVER
M
R
A
W
L
O
O
C
MOUNTING HOLES (4)
M658A
Fig. 11. Mount guard wallplate and ring base on back-wired thermostat.
9
68-0104—4
TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
Junction Box Mounting (Fig. 12)
Place the thermostat subbase (or wallplate) on the
wallplate template and mark the mounting holes.
Locate the mounting holes on the guard wallplate using
the template as a guide.
Drill the required 5/32 in. mounting holes in the guard
wallplate.
Secure the guard wallplate to the ring base using the
screws provided.
Place the guard wallplate (with smooth side facing the
ring base) on the back of the ring base.
Insert the securing screws through the holes on the
front of the ring base and into the posts on the wallplate. See Fig. 12.
Tighten the screws securely.
NOTES: When using a front-wired subbase
(wallplate), run the system wires from the junction box through the wiring hole in the guard wallplate and subbase (wallplate) cable opening.
When using a back-wired subbase (wallplate), run the system wires from the junction box through the wiring hole in the guard wallplate only.
Wire the back-wired subbase. Refer to the instructions
provided with the thermostat.
Mount the thermostat subbase (wallplate) and the ring
base with the guard wallplate to the junction box using the 1-1/4 in. sheet metal screws provided.
Wire the front-wired subbase (wallplate). Refer to the
instructions provided with the thermostat.
Mount the thermostat on the subbase (wallplate).Place the thermostat cover on the thermostat.Mount the guard cover by placing the hinged edge of
the guard cover on the ring base and swinging it down (horizontal mounting) or to the side (vertical mounting) until the guard cover is in place against the ring base. See Fig. 7.
Lock the thermostat guard by turning the key (provided)
counterclockwise. See Fig. 8. The key can only be removed in the locked position.
Remove the paper backing and clear protective cover
from the included monogram and place the monogram in the recessed area on the guard cover. See Fig. 9.
HORIZONTAL OUTLET BOX
GUARD WALLPLATE
WALLPLATE POSTS
RING BASE
SECURING SCREWS (4)
THERMOSTAT
HEAT
50 60 70 80
SUBBASE
50 60 70 80
50 60 70 80
MOUNTING SCREWS (2)
COOL
M1638A
Fig. 12. Mount guard wallplate with ring base and thermostat on junction box (front-wired thermostat subbase shown).
68-0104—4
10
TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
COVER
RING BASE
M659
KEY
Remove Thermostat Guard
Remove the thermostat guard cover by inserting the
key and turning the key clockwise until the locking mechanism is disengaged.
Remove the guard cover by swinging it out away from
the ring base and lifting it off. See Fig. 13.
CHECKOUT
Before leaving the installation, refer to the applicable instructions to check the operation of the thermostat or subbase.
Fig. 13. Remove thermostat guard cover
(TG510, TG511, TG512 shown).
11
68-0104—4
TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
Home and Building Control
Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis MN 55408-0524
Honeywell Latin American Division
Miami Lakes Headquarters 14505 Commerce Way Suite 500 Miami Lakes FL 33016
68-0104—4
68-0104—4 J.S. Rev. 11-96 Printed in U.S.A.
Home and Building Control
Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 2C9
Honeywell Europe S.A.
3 Avenue du Bourget B-1140 Brussels Belgium
Printed on recycled paper containing at least 10% post-consumer paper fibers.
12
Honeywell Asia Pacific Inc.
Room 3213-3225 Sun Hung Kai Centre No. 30 Harbour Road Wanchai Hong Kong
Helping You Control Your World
www.honeywell.com/yourhome
®
Loading...