Honeywell TE923W User Manual 2

HONEYWELL
PROFESSIONAL WEATHER STATION
WITH REMOTE CONTROL
TE923W
Table of Contents
Introduction 3 Standard Package Contents 4 Installation 5 Before you begin 6 UV (Ultraviolet) Sensor 6
Thermo-Hygrometer Sensor 9 Rain Gauge 11 Anemometer (wind sensor) 13 Main Unit 15 Battery installation 16 Buttons and Controls 17 Navigating through the modes 19 Customizing your Weather Sta ti on 22 LED Backlight Options 23 Connecting the Weather Station to a PC 23 Using Different Weather Modes 23 Pressure and Weather Forecast Mode 23 UV Mode 26 Clock and Alarm Mode 27 Manual Settings 27 Sunrise/Sunset Mode 30 Temperature and Humidity Mode 32 Rain Mode 34 Wind Mode 35 Maintenance 37 Troubleshooting 38 PRECAUTIONS 39 Appendix - City Codes 40 US and Canadian Cities 40 Specifications 42 FCC STATEMENT 45 DECLARATION OF CONFORMITY 45 ST ANDARD WARRANTY INFORMATION 46
2
Introduction
Thank you for selecting the Honeywell Professional Weather Station with remote control.
This compact and easy-to-use product features a wide variety of time and weather data,
such as precise atomic time, perpetual calendar, air temperature, relative humidity,
barometric pressure, wind speed and direction, rainfall, UV levels and etc.
In this package you will find:
One Main Unit (receiver) (TE923WD)
One IR Remote Control (TS607)
One Rain Gauge (remote rain sensor/transmitter) (TS906)
One Anemometer (remote wind sensor/transmitter) (TS805)
One UV (ultraviolet) sensor (remote ultraviolet sensor/transmitter) (TS704)
One Five-Channel Temperature & Humidity Sensor (transmitter) (TS34C)
One CD disk with generic PC connection software with USB cable
One 7.5V AC/DC Adapter
Mounting Hardware with wrench tool
One User Manual
3
Standard Package Contents
Picture Components
Main Unit
AC/DC 7.5V power adaptor
UV Sensor consists of:
U-Shaped Sensor holder
Thermo Hygrometer Sensor
Rain Gauge consists of:
Funnel shaped top with battery
Bucket see-saw mechanism
Anemometer consists of:
Remote Control
Sensor Unit
Circular Ground Stand
Stake Base
Wall-Mounting Base
compartment
Rain Gauge bucket
Protective screen
Wind Cups Wind Vane
Anemometer arm
Anemometer base
4
PC Software
4 screws for securing rain gauge to the flat
surface;
4 screws for securing anemometer to vertical
surface
2m (6ft) USB cable
Mounting hardware
PC connection cable
Installation
The Honeywell Professional Weather Station TE923W operates at 433MHz radio frequency, so no wire installation is required between the main unit (receiver) and the remote weather sensors (transmitters). The remote weather sensors include a thermo-hygrometer (temperature and humidity) sensor, UV (ultraviolet) sensor, anemometer (wind sensor) and a rain gauge (rain sensor). All data measured by these remote sensors is transmitted to the main unit wirelessly, with the operating range up to 328 feet (100 meters) in the open area. Remote UV sensor, anemometer and a rain gauge must be placed outdoors to measure weather elements. Remote thermo-hygrometers can be placed indoors or outdoors, depending on the area where the temperature and humidity are intended to be measured. If you intend
measuring outdoor temperature and humidity, place the remote sensor outdoors.
Note: It is critical to assemble and power up all of the remote weather sensors BEFORE
setting up the main unit.
Note: It is critical to power up and test communication between all of the weather sensors and the main unit BEFORE permanently mounting them outside.
5
Before you begin
We recommend using alkaline batteries for the remote weather sensors and the
main unit when temperatures are above 32°F (0°C). We recommend using lithium batteries for the remote weather sensors when temperatures are below 32°F (0°C).
Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain
correct power requirements).
ALWAYS install batteries in the remote weather sensors before the main unit.
Insert batteries before first use, matching the polarity in the battery compartment
Remove protective plastic screen from LCD display (if any).
During an initial setup, place the main unit close to the remote weather sensors.
After reception is established (all of the remote readings will appear on the main
unit’s display), position the remote sensors and the main unit within the effective transmission range of up to 328 feet (100 meters). Ideally they should be placed within the line of sight of the main unit. See placement tips in the user manual for each remote weather sensor separately.
Transmission range may be affected by trees, metal structures and electronic
appliances.
The main unit must be placed indoors.
The effective operating range may be influenced by the surrounding building
materials and how the receiver (main unit) and transmitters (weather sensors) are positioned.
Place the remote weather sensors so that they face the main unit (receiver),
minimizing obstructions such as doors, walls, and furniture.
Note: When the temperature falls below freezing, the batteries in the outdoor remote weather sensors may have reduced voltage supply and a shorter effective range. We recommend using lithium batteries at temperatures of 32°F (0°C) and below.
IMPORTANT
cleaning and maintenance. We recommend cleaning the remote weather sensors periodically, as the dirt and debris may affect sensors accuracy.
: Make sure that the remote weather sensors are easily accessible for
6
UV (Ultraviolet) Sensor
FEATURES
Ultraviolet light levels measurement
Remote UV levels data transmission to the main unit via 433MHz signal
328 feet (100 meters) transmission range
Low battery indicator
Three different placement options – ground, stake and wall
A
G B
F
C
E
D
A. LED INDICATOR
Flashes once when the remote sensor transmits a reading to the main unit
Flashes twice when battery power is low
B. BATTERY COMPARTMENT SCREW
Holds battery compartment door in place
C. U-SHAPED SENSOR HOLDER
Holds UV sensor in upright position
D. CURCULAR GROUND STAND Secures sensors in the sensor holder on the flat surface E. UV SENSOR LID
Covers UV sensor and battery compartment
F. BA TTERY COMPARTMENT
Holds two AA-size batteries
G. BATTERY COMPARTMENT DOOR
Covers two AA-size batteries
7
Assembly
Snap the U-shaped sensor holder onto the UV sensor unit side grooves
Insert the round end of the U-shaped holder into one of the mounting hardware
pieces provided
Battery installation
Unscrew the lid on top of the UV sensor unit.
Remove the screw from the battery compartment door with a small Phillips
screwdriver
Insert two 2 “AA” size 1.5V batteries (not included) matching the polarities
shown in the battery compartment.
Replace the battery compartment door and secure the screw
Screw the UV sensor unit lid back
Mounting
There are three different options available for mounting the UV sensor: ground stand, stake and wall mount.
Ground:
Insert the U-shaped sensor holder round end into the circular ground stand
opening, matching 2 round holes in the opening
Secure the sensor in a location with a maximum sun exposure throughout the
day.
Stake:
Snap the sharp stake end onto the metal bar and secure with the screws
provided.
Insert the other end of the metal bar into the U-shaped sensor holder and secure
with the screws provided.
Secure the sensor in a location with a maximum sun exposure throughout the
day.
Wall:
Insert the wall mounting end into the metal bar and secure with the screws
provided.
Snap the other end of the metal bar on to the U-shaped sensor holder and secure
with the screws provided.
Secure the sensor in a location with a maximum sun exposure throughout the
day.
Placement tips:
The UV sensor should be mounted in the area free of sunlight shadows or reflections from the nearby objects.
8
Thermo-Hygrometer Sensor
FEATURES
Remote data transmission to the main unit via 433 MHz signal
328 feet (100 meters) transmission range without interference
LCD display of measured temperature and humidity
Five (5) transmission channels selection
Case can be wall mounted using built-in hanger
A. LED INDICATOR
Flashes once when the remote sensor transmits a reading to the main unit.
Flashes twice when battery power is low.
B. BATTERY COMPARTMENT
Holds two AA-size batteries
C. RESET
Resets all readings
D. CHANNEL SWITCH
Selects the desired channel from 1 to 5
E. WALL-MOUNT RECESSED OPENING Keeps the remote sensor on the wall
Note: Install the batteries and select the channel before mounting the sensor.
Battery installation
Remove the screws from the battery compartment with a small Phillips
screwdriver.
Set the channel 1 through 5. The switch is located in the battery
compartment. Channel 1 is typically selected if only one remote sensor is being used.
Install 2 “AA” size alkaline batteries (not included) matching the polarities
shown in the battery compartment.
Replace the battery compartment door and secure the screws.
Secure the thermo-hygrometer remote sensor in the desired location.
Mounting
9
The remote thermo-hygrometer sensor can be placed on the flat surface or
mounted on the wall in vertical position
Use the wall mount hardware and screws provided when mounting the
thermo-hygrometer sensor on the wall
Placement tips:
The remote thermo-hygrometer sensor should be placed in the area with a free
air circulation and sheltered from the direct sunlight and an extreme weather conditions.
Ideally, place the thermo-hygrometer sensor above the natural surfaces (such as
a grassy lawn).
Avoid placing the thermo-hygrometer sensor near sources of heat such as
chimneys and heating elements.
Avoid any areas collecting and radiating a heat from the sun, such as metal,
brick or concrete structures, paving, patios and decks.
The international standard for the valid air temperature measurements is 4 feet
(1.25meters) above the ground.
10
Rain Gauge
FEATURES
Precipitation measurement
Remote rainfall data transmission to the main unit via 433 MHz signal
100 feet (30 meters) transmission range without interference
Built-in installation level
Non-corrosive protective screen
B
A. Rain gauge bucket
Holds all rain gauge components
B. Knob
Secures the top on the rain gauge bucket
C. Rain gauge bucket feet
Allows securing the rain gauge on its place
G
D
E
F
D. Funnel-shaped top with battery compartment Contains battery compartment and rainfall counting electronics E. Battery compartment
Holds two AA-size batteries
F. Screws
Secure battery compartment cover
A
C
H
I
11
G. Built-in leveler
Allows leveling rain gauge on the surface
H. Bucket see-saw mechanism
Collects the rainfall in one of its containers and self-empties once full
I. Protective screen
Protects the rain gauge funnel from debris
Battery installation
Unlock the funnel-shaped top on the rain gauge by turning both knobs on the
sides in an anti-clockwise direction.
Remove the funnel-shaped top lifting it off the rain gauge bucket.
Remove 7 small screws from the battery compartment cover using a small
Phillips screwdriver
Insert 2 “AA” size alkaline batteries (not included), matching the polarities as
shown in the battery compartment.
Replace the battery compartment door and secure the screws.
Insert the funnel-shaped top into the rain gauge bucket and secure it into place
by turning the knobs clockwise.
Mounting
Make sure that the rain gauge bucket is level – check if the ball bearing inside
the bucket is at the midpoint of the leveler.
Place the protective screen over the top to protect the rain gauge from the debris.
Mount the rain gauge in place using mounting hardware provided.
Make sure that the rain gauge is in open area where precipitation falls directly
into the gauge’s bucket, ideally 2-3 feet above the ground.
Placement tips
The rain gauge should be placed in an open area away from the walls, fences,
trees and other coverings which may reduce the amount of rain falling into the bucket. Additionally, trees and rooftops may be sources of pollen and debris.
To avoid the rain shadow effects, place the rain gauge horizontally, on the
distance corresponding to two to four times the height of any nearby obstruction.
It is important that excess rain can flow freely away from the rain gauge.
12
Anemometer (wind sensor)
FEATURES
Wind speed and wind direction measurement
Remote wind speed and wind direction data transmission to the main unit via
433 MHz signal
Operating range 100 feet (30 meters)
Wall or pole mount
A
D B
C
A. WIND VANE
Measures wind direction
B. WIND CUPS
Measures wind speed
C. ANEMOMETER BASE
Holds battery compartment
Allows mounting the anemometer vertically
D. ANEMOMETER ARM
Keeps anemometer assembly together
G
F
H
E
13
E. WIND CUPS SHAFT
Holds wind cups on the anemometer arm
F. BATTERY COMPARTMENT
Holds 2 AA-size batteries
G. WALL MOUNT SCREW OPENINGS
Allows securing the anemometer in place
H. BATTERY COVER
Allows securing 2 AA size batteries on the anemometer base
Assembly
Place the wind cups over the wind cups shaft of the anemometer arm
Insert the wrench tool provided into the wind cups opening and tighten the small
screw inside.
Test if the wind cups sit secure on the wind cups shaft
Battery installation
Remove four (4) screws from the battery compartment with a small Phillips
screwdriver.
Open the battery compartment and install 2 “AA” size alkaline batteries (not
included) matching the polarities shown.
Replace the battery compartment door and secure the screws.
Aligning
Point the wind direction vane to the north (use a compass or map if necessary).
Press “SET” opening located inside battery compartment with a paper clip or
similar tool. The “SET” opening controls toggling the wind direction between
the factory preset or user set.
Select the factory set mode. It will be also a default setting in the future.
Set current wind direction as NORTH.
Note: Repeat this procedure every time when changing the batteries. Mounting
Mount the anemometer onto a vertical surface, using the fittings provided.
Placement tips:
The anemometer should be mounted in an open area with a free air flow; away
from the nearby trees, buildings or other structures.
Aim for a maximum exposure of the anemometer to the most common wind
directions in the area.
It is suggested mounting anemometer at 33 feet (10meters) above the ground in
unobstructed area.
14