Introduction 3
Standard Package Contents 3
Installation 3
Before you begin 3
Thermo-Hygrometer Sensor TS33C 4
Rain Gauge TS9 06 6
Anemometer (wind sensor) TS805 7
Main Unit 9
Power 10
Buttons and Controls 11
Initial Set up 13
Operation and Window Selec tion 13
Custom Weather Station Settings 15
LED Backlight Options 24
Time Alarm Settings 24
Memory Reset Procedure 26
Maintenance 26
Troubleshooting 27
PRECAUTIONS 28
Appendix - City Codes 28
Specifications 30
FCC STATEMENT 32
DECLARATION OF CONFORMITY 33
STANDARD WARRANTY INFORMATION 33
2
Introduction
Thank you for selecting the Honeywell Semi-Professional Weather Station. This compact and easy-to-use product uniquely
measures and monitors weather data right at your immediate location. It includes a wide range of weather features plus
precise atomic time and perpetual calendar. Weather measurements include: air temperature, relative humidity, barometric
pressure, wind speed and direction, rainfall levels and more.
Standard Package Contents
In this package you will find:
One Main Unit (receiver) (TE821WD)
One Rain Gauge (remote rain sensor/transmitter) (TS906)
One Anemometer (remote wind sensor/transmitter) (TS805)
One Three-Channel Temperature & Humidity Sensor (transmitter) (TS33C)
One 7.5V AC/DC Adapter
Anemometer Mounting Hardware with wrench tool
One User Manual
Required for installation (not included)
- Small Phillips screwdriver
- Anemometer mounting pole
- Small paper clip to reset sensors
NOTE: If any items are missing or damaged, please contact Hideki Electronics Customer Service before proceeding with
installation.
Installation
The Honeywell Semi-Professional Weather Station operates at 433MHz radio frequency, so no wire installation is required
between the main unit (receiver) and the remote weather sensors (transmitters). The remote weather sensors include (1)
thermo-hygrometer (temperature and humidity) sensor, anemometer (wind sensor) and a rain gauge (rain sensor). All data
measured by these remote sensors is transmitted to the main unit wirelessly, with the operating range up to 328 feet (100
meters) in the open area. The Anemometer and the Rain Gauge must be placed outdoors to measure weather elements .
Remote Thermo-Hygrometer can be placed indoors or outdoors. If you intend measuring outdoor temperature and humidity,
place the remote sensor outdoors, preferably not in the direct sunlight.
Before you begin
The components of this Honeywell Semi-Professional Wireless Weather Station operate at 433MHz radio frequency. No
3
interconnecting wires are required between the main unit (receiver) and the remote sensors (transmitters).
Power up and test communications between all of the sensors and the main unit BEFORE mounting them outside.
· For most applications alkaline batteries are acceptable where temperatures remain above 32°F (0°C).
· At temperatures below 32ºF(0ºC) use lithium batteries otherwise transmission performance will be reduced or
interrupted
· Avoid using rechargeable batteries. (Rechargeable batteries do not provide correct power levels).
· ALWAYS install batteries in the remote sensors before the main unit. (Please read batteries installation instructions in
the manual for each remote sensor before installation)
· Insert batteries matching the polarity in the battery compartment
· Remove plastic sleeve from LCD display (if any).
· During an initial setup, place the main unit close to the remote sensors.
· After reception is established (all of the remote readings will appear on the main unit’s display), position the remote
sensors and the main unit within the effective transmission range. Ideally they should be placed within the line of sight
of the main unit. See placement tips in the user manual for each remote sensor.
· Transmission range may be affected by trees, metal structures and electronic appliances.
· The main unit must be placed indoors.
· The effective operating range may be influenced by the surrounding building materials and how the receiver (main unit)
and transmitters (sensors) are positioned.
· Place the remote sensors so that they face the main unit (receiver), minimizing obstructions such as doors, walls, and
furniture.
· Make sure that the remote sensors are easily accessible for cleaning and maintenance.
Note: When the temperature falls below freezing, the outdoor sensor batteries may have reduced voltage and a reduced
effective range. We recommend using lithium batteries at temperatures below 32°F (0°C).
IMPORTANT: We recommend cleaning the remote sensors periodically, as dirt and debris affects sensor accuracy.
Thermo-Hygrometer Sensor TS33C
FEATURES
· LCD display of measured temperature and humidity
· Remote data transmission to the main unit via 433 MHz signal
· 328 feet (100 meters) transmission range without interference
· Three (3) transmission channels selection
· Case can be wall mounted using built-in hanger
4
A. LED INDICATOR
· Flashes once when the remote sensor transmits a reading to the main unit.
· Flashes twice when battery power is low.
B. BATTERY COMPARTMENT
Holds two AA-size batteries
C. RESET
Resets all readings (requires small paper clip.)
D. CHANNEL SWITCH
Selects the desired sensor channel from 1 to 3
E. WALL-MOUNT RECESSED OPENING
Keeps the remote sensor on the wall
Note: Install the batteries and select the channel before mount ing the sensor
Battery installation
· Remove the screws from the battery compartment with a small Phillips screwdriver.
· Set the channel 1 through 3. The switch is located in the battery compartment.
If you have more than one sensor, set one sensor to Channel 1 and the second sensor to Channel 2, etc. The sensors must
operate on separate channels. Install 2 “AA” size batteries matching the polarities shown in the battery compartment.
IMPORTANT: When channel number is selected, it will be displayed on the sensor’s LCD display
· Replace the battery compartment door and secure the screws.
·
Secure the thermo-hygrometer remote sensor in the desired location.
Mounting
· The remote thermo-hygrometer sensor can be placed on the flat surface or mounted on the wall in vertical position
· Use the screws when mounting the thermo-hygrometer sensor on the wall
Placement tips:
· The remote thermo-hygrometer sensor should be placed in the area with a free air circulation and sheltered from the
5
direct sunlight and an extreme weather conditions.
· Ideally, place the thermo-hygrometer sensor above the natural surfaces (such as a grassy lawn).
· Avoid placing the thermo-hygrometer sensor near sources of heat such as chimneys and heating elements.
· Avoid areas that collect or radiate heat from the sun, such as metal, brick/concrete structures, paving, or patio decks.
· The best location for temperature measurements is 4 feet (1.25meters) above the ground.
Rain Gauge TS906
FEATURES
· Precipitation measurement
· Remote rainfall data transmission to the main unit via 433 MHz signal
· 100 feet (30 meters) transmission range without interference
· Built-in installation level
A. Rain gauge bucket
Contains electronic components
B. Knob
Secures the top on the rain gauge bucket
C. Rain gauge feet
Secures the rain gauge in place
D
E
F
G
B
A
H
C
D. Funnel-shaped top with battery compartment
Contains battery compartment and rainfall counting electronics
6
I
E. Battery compartment
Holds two AA-size batteries
F. Screws
Secures battery compartment cover
G. Built-in level with bubble
Ensures level rain gauge mounting for proper operation
H. Bucket see-saw mechanism
Collects the rainfall in one of its containers and self-empties once full
I. Protective screen
Protects the rain gauge funnel from debris
Battery installation
· Unlock the funnel-shaped top on the rain gauge by turning both knobs on the sides in an anti-clockwise direction.
· Remove the funnel-shaped top lifting it off the rain gauge bucket.
· Remove 7 small screws from the battery compartment cover using a small Phillips screwdriver
· Insert 2 “AA” size alkaline batteries (not included), matching the polarities as shown in the battery compartment.
· Replace the battery compartment door and secure the screws.
· Insert the funnel-shaped top into the rain gauge bucket and secure it in place by turning the knobs clockwise.
Mounting
· Make sure that the rain gauge bucket is level – check inside built-in level for bubble center.
· Place the protective screen over the top to protect the rain gauge from the debris.
· Where practical, mount the rain gauge in place with wood screws (not included).
· Make sure that the rain gauge is in open area where precipitation falls directly into the gauge’s bucket, ideally 2-3 feet
above the ground.
Placement tips
· The rain gauge should be placed in an open area away from the walls, fences, trees and other coverings which may
reduce the amount of rain falling into the bucket. Additionally, trees and rooftops may be sources of pollen and debris.
· To avoid the rain shadow effects, place the rain gauge horizontally, on the distance corresponding to two to four times
the height of any nearby obstruction.
· It is important to locate the unit where rain can flow away freely.
Anemometer (wind sensor) TS805
FEATURES
· Wind speed and wind direction measurement
· Remote wind speed and wind direction data transmission to the main unit via 433 MHz signal
· Operating range 100 feet (30 meters)
7
· Wall or pole mount
A. WIND VANE
Indicates wind direction
B. WIND CUPS
Measures wind speed
C. ANEMOMETER BASE
· Holds battery compartment
· Allows mounting the anemometer vertically
D. ANEMOMETER ARM
Connects battery to the anemometer head assembly.
A
G
C
F
E. WIND CUPS SHAFT
Holds wind cups on the anemometer arm
F. BATTERY COMPARTMENT
D
E
B
H
Holds 2 AA-size batteries
G. WALL MOUNT SCREW OPENINGS
Allows securing the anemometer in place
H. BATTERY COVER
8
Secures battery compartment on the anemometer base
Assembly
· Slide the wind cups on to the anemometer rotating shaft. Do not use force.
· Insert the longer arm of the Allen Wrench (provided) into the wind cup set screw opening. Feel the head of the set
screw inside the wind cups and tighten carefully the set screw securing the wind cups to the rotating shaft.
· Test to ensure cups are securely fastened to the shaft and cannot be removed
Battery installation
· Remove four (4) screws from the battery compartment with a small Phillips screwdriver.
· Open the battery compartment and install 2 “AA” size alkaline batteries (not included) matching the polarities shown.
· Replace the battery compartment door and secure the screws.
Aligning
· Manually point the wind direction vane to the north (use a compass or map if necessary).
· Press the “SET” button located inside battery compartment (on the shorter side) with a paper clip. “SET” button selects
a new direction for NORTH and, when pressed repeatedly, alternates between the factory default NORTH and user
selected NORTH.
Note: Repeat this procedure every time after changing the batteries.
Mounting
Mount the anemometer onto a vertical surface, using the fittings provided.
Placement tips:
· The anemometer should be mounted in an open area with a free air flow; away from the nearby trees, buildings or
other structures.
· For optimal performance, mount the anemometer at 33 feet (10meters) above the ground in unobstructed area.
Main Unit
The main unit measures pressure, indoor temperature, humidity, and receives atomic time data from the US Atomic Clock and
outdoor measurements from remote sensors. It should be placed indoors.
FEATURES
Time
· Precise time and date set via RF signals from US Atomic clock
· 12 or 24 hour time format
· Manual adjustment of time and date
· Calendar displaying date with month and day in 6 languages English, German, French, Italian, Spanish and Dutch
· Time Zones for over 100 pre-programmed world cities
9
Weather
· Moon Phase calendar and historical data for the past and future 39 days
· Dual crescendo alarms with programmable snooze
· Weather forecast for the next 12 to 24 hour in seven large icons: Sunny, Partly Cloudy, Cloudy, Light Rain, Heavy
Rain, Unstable Weather and Snowy
· Barometric pressure in imperial or metric units
· Altitude adjustment for pressure compensation
· 24 hour barometric pressure history chart
· Multiple weather alerts including: Hi/Low temperature, Daily Rainfall, Hi wind gust and Hi wind speed alerts
· Indoor/Outdoor Temperature & Humidity in up to 4 remote locations (additional sensors required)
· Dew point and comfort level indicators
· Wind direction, speed and wind gust averages and memory
· Rainfall amount with minimum and maximum memory
· Operating range from 100 feet (30 meters) up to 328 feet (100 meters)
Display
· Light sensor detects low light conditions and LCD lights up automatically when adapter is connected
Power
· Open the battery compartment door on the back of the main unit.
· Insert four (4) AA size batteries according to the polarities shown and replace the battery compartment door.
· Connect 7.5V AC/DC adapter provided to the main display unit and plug into the wall power outlet.
Note: The AC/DC adaptor connection is required for automatic backlight control. When the main unit operates
solely on the battery power, the auto backlight control functions are disabled.
· When placing the main unit on the table or other horizontal surface, connect the table stand to the back of the unit.
· When mounting the main unit on the wall or vertical surface, detach the table stand and use the mounting hardware
Placement tips
· Make sure that the main unit is locating within the operating range of all remote sensors.
· Ideally the remote sensors should be mounted within the line of sight of the main unit.
· Transmission range may be affected by trees, metal structures and electronic appliances.
· Test reception before permanently mounting all the remote sensors.
Avoid placing the main unit in the following areas:
· Direct sunlight and surfaces emitting and radiating heat, such as heating ducts or air conditioners.
· Areas with interference from the wireless devices (such as cordless phones, radio headsets, baby listening devices)
and electronic appliances.