Honeywell T675F Catalog Page

Honeywell T675F Catalog Page

Temperature Controllers

T675F Crop-Trol Controller

Dimensions in inches (millimeters)

7/8 (22) DIA KNOCKOUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-1/8

 

 

 

 

 

 

 

 

 

 

 

 

 

(BOTH ENDS)

 

 

 

 

 

 

 

 

 

(54)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-19/32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15/16 (24)

(66)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 (51)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-5/8

(143)

MOUTING HOLES LOCATED IN BACK OF CASE

4-3/16

(106)

11/16

(18)

1-1/4

(32)

M23927

Used to control an oil burning, portable crop dryer.

Suitable for line-voltage, low-voltage or millivolt (Powerpile) switching

Mounts directly on dryer with sensing bulb in discharge air duct

Knob extends through case for manual control point adjustment

Differential setting wheel, located under cover, adjusts difference between cut-in and cut-out temperatures

Type: Remote bulb

Application: Crop-trol, provides control of portable crop drying equipment Bulb Size: 3/8 in. x 3 in. (10 mm x 76 mm)

Sensor Element: Copper bulb

Contact Ratings (120 Vac): 8.0 AFL, 48.0 ALR

Contact Ratings (240 Vac): 5.1 AFL, 30.6 ALR

Contact Ratings (277 Vac): 4.2 AFL, 25.2 ALR

Voltage: 120 Vac or 240/277 Vac

Frequency: 50 Hz; 60 Hz

Maximum Operating Temperature: 245 F (118 C)

Setpoint Temperature Range: 80 F to 220 F (27 C to 104 C) Differential Temperature: 5 F to 30 F (2.8 C to 17 C)

Approvals

Underwriters Laboratories, Inc: Component Listed

 

 

 

 

 

 

 

 

 

Capillary Length

 

 

 

 

 

 

 

 

 

 

Product Number

Description

(m)

(ft)

Output

Output Type

Number of Sensor Inputs

 

 

 

 

 

 

 

T675F1032/U

Remote bulb Commercial Temperature Controller, 80 F

3 m

10 ft

1 SPDT

relay

1

 

to 220 F, 10 ft. capillary, Copper bulb sensing element

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>Commercial

<![if ! IE]>

<![endif]>Components

70-6910

 

 

 

351

 

 

Loading...