FEATURES
One or two ON/OFF periods per day.
Built-in battery back-up.
Clear digital display.
Ease of operation.
Temporar y or permanent over-ride
facilities.
12 hour time display with am/pm
indication.
Simple change to 24 hour
clock display.
Programme indicator lights.
Double insulated.
Extra hour facility for one hour
boost or programme extension.
Earth wire parking
terminal.
APPLICATION
The ST6300A is an electronic central heating time control programmer that can be used on fully pumped systems having separate heating and hot water temperature control where common switching times for heating and hot water are required.
A hinged cover conceals the programming buttons when not in use, leaving only the override and extra hour buttons exposed. The front cover also carries abbreviated user instructions on the inside for permanent ready reference.
2.13
Mon Tue Wed Thu Fri Sat Sun
OFF
ON
OFF
ON
OFF
ON
HOT WATER
HEATING
EXTRA HOUR
OVERRIDE
Mon Tue Wed Thu Fri Sat Sun
ON
OFF
ON
OFF
ON
HOT WATER
HEATING
OVERRIDE
EXTRA HOUR
RESET
COPY
DAY
NEXT ON/OFF
–+
OFF
ONCE CONT.
AUTO
SET TIME –
SET PROGRAMME –
RUN PROGRAMME –
ELECTRONIC PROGRAMMER ST6300
Installation
ST6300 can be either sur face or flush switch box mounted, for both of which fixing screws are supplied. The wiring sub-base has holes to suit single switch boxes and breakouts for surface wiring and mini-trunking.
When wiring is completed the plug-in module is fitted onto the sub-base and secured by tightening the retaining screws.
Ordering Specification
ST6300A1007 Electronic programmer having two ON/OFF periods with separate outputs for heating and hot water circuits.
Wiring
Specification
Switch Type : Single Pole Double Throw (SPDT)
Switch Rating : 3(3)A
Timing Accuracy : ±1 min/month
Timing Resolution : Time of Day 1 minute
: Programme Times 10 minutes
Ambient Operating Temperature : 0-50˚C
Power Reserve : Minimum 4 days
Weight : 330g approx (including wall plate)
Earthing : Double Insulated
Battery Back-Up : Integral battery with built-in charging circuit
Standards : Complies with BS EN60730-2-7
EC Directive : Conforms to 89/336/EEC & 73/23/EEC
Dimensions (mm)
ABCD
145 95 45 120
ST 6300
Clock
OFF
OFF
ON
ON
CH ON
CH OFF
HW ON
TIMED OUTPUTS
HW OFF
NL 1 23 4
3 AMPS MAX
N
L 230V~
50...60Hz
A
B
C
D